SECTIONAL BODY STANDARD FEATURES. Enhanced Metering Section Available in Reversible Handle. Flow Control Inlet

Similar documents
STANDARD FEATURES. Flow Control Inlet

STANDARD FEATURES. Flow Control Inlet

SECTIONAL BODY. Model SV. Directional Control Valves VALVES STANDARD FEATURES SPECIFICATIONS. Parallel or Series Circuit Construction ...

LOAD SENSE SECTIONS. Series 20. Directional Control Valves NEED NEW PIC VALVES STANDARD FEATURES SPECIFICATIONS

SV SOLENOID OPERATED

SECTIONAL BODY. Series 20. Directional Control Valves STANDARD FEATURES SPECIFICATIONS VALVES. Pressure Rating

Service and Parts Manual. Minimum Filtration Required:

Series 34. Sectional Directional Control Valve Specifications: P34A Engineering & Manufacturing Solutions

CLS100 Proportional Load Sensing Mobile Valve

Monoblock Directional Control Valve PMB22TSTSAB PMB23TSTSTSLB PMB21TDLB

Directional Control Valve CV550

Full Range Pressure Compensating Variable Flow Control

Proportional Valves. Proportional solenoid valves for pressure and flow control

Contents. Quality Hydraulic Components from the Webtec Range. Introduction. Hydraulic Flow Control Valves

Large Electronically Adjustable Proportional Pressure Compensated Flow Control Engineering & Manufacturing Solutions

EFC. Electronically Adjustable Proportional Pressure Compensated Flow Control

CLS180 Proportional Load Sensing Mobile Valve

Auxiliary valves. Lever. Spool positioner Check valve Spool

V050 SERIES DIRECTIONAL CONTROL VALVE

V250 SERIES DIRECTIONAL CONTROL VALVES

and RD5000 or by the Utility section in the Series 20 valves. 7. The internal pilot pressure is used to initiate the spool shift when a solenoid is en

Commercial Shearing (Pty) Ltd THE WORLDWIDE PROGRAM OF VALVES ISO 9001

MP18 Stacking Valve System Technical Information Manual

-Technical data... 2/14 -Circuit mode... 2/14 -Dimensions RP /14

4-Way Directional Control Valve With Hydraulic Kick Out

4 WAY DIRECTIONAL CONTROL VALVE AO

Post-Compensated Proportional Valve CV2000LS

Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI

4-Way Directional Control With Pressure Compensated Flow Control PSDCF120M64LF Specifications:

Super Charged Piston Pumps Variable Displacement For Open Circuits. PAVC Medium Pressure

Monobloc and Sectional Directional Control Valves

Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI

Solutions. ydraulics. We Manufacture. H y d r a u l i c s. Eaton Directional Control Valves. h y d r a u l i c s. Models and 31930

Mobile Valves Proportional - Load Sensing

MONOBLOCK DIRECTIONAL CONTROL VALVES

60VSERIES PFD-30 MSV-16 RV-30, RV-60. Muncie Power Products MP95-08 (Rev. 5-05) Printed in the U.S.A. Muncie Power Products, Inc VALVE WARRANTY

3PC Directional Control Valves

Vickers. Proportional Valves. EPV10 Series. Proportional Flow Controls. Released 6/95

Sectional Directional Control Valve RSQ 240

90VSERIES DIRECTIONAL CONTROL VALVE MSV-16 RV-30, RV-60 PFD-30

Series PVP Variable Volume Piston Pumps

17 SERIES DIRECTIONAL CONTROL VALVE

CH.4 Basic Components of Hydraulic and Pneumatic System/16 M HAP/17522/AE5G

LOGIC POPPET VALVES AND CARTRIDGE MANIFOLD SYSTEMS

Vickers. Proportional Valves. EPV16 Series Valvistor Proportional Flow Controls

Section 6.1. Implement Circuit - General System. General: TF Configuration TB Configurations Implement Control Valve:

OPERATION AND PARTS MANUAL

Proportional Valves. Proportional solenoid valves for pressure and flow control B-1.A. An Eaton Brand

Catalog HY /NA. Catalog HY /NA. Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA

MP18/SIC & SIO Stacking Valve System Technical Information Manual

CONTINENTAL HYDRAULICS LPV SERIES AXIAL PISTON PUMPS

DC Series. 4-Way Directional Control Valve With Or Without Flow Control PDC16T4PBS PDCF16TM454LF

Vickers. Overhaul Manual. Directional Controls. CMX Sectional Directional Valve -25 Design. CMX100 & CMX160 Hydraulic & Electrohydraulic Actuation

LOGIC POPPET VALVES AND CARTRIDGE MANIFOLD SYSTEMS

General Valve Assembly Information

2.3 MEDIUM HEAVY DUTY SERIES

Logic elements. Differential pressure sensing elements for applications up to 350 bar (5000 psi) and 400 L/min (100 USgpm)

HYDRAULIC CONTROL VALVES

DMH085** Series will be available January 1, Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO.

Super Charged Piston Pumps Variable Displacement For Open Circuits. PAVC Medium Pressure

Heavy Duty Hydrostatic Transmissions

36EFC. Series & EFC Valve Package

Contents. Directional Control Valve 2 Series CV 300

CONTROL SOLUTIONS FORKLIFT TRUCKS FORKLIFT TRUCKS

PRODUCT OVERVIEW. Our Mission:

Available manual, pneumatic, and hydraulic spool control kits.

Check valves Direct and pilot operated check valve functions for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm)

Module 5: Valves. CDX Diesel Hydraulics. Terms and Definitions. Categories of Valves. Types of Pressure Control Valves

Pressure Control Valves

V5 60 LPM SECTIONAL SPOOL VALVE

Solutions. Hydraulics. We Manufacture. H y d r a u l i c s. Eaton. h y d r a u l i c s. Models and with Pilot Operated Checks

Hand-operated Hydraulic Control Valve 4- way 2-position 4 Ports

Directional Control Valve Series 4D01 (DENISON)

Manual Proportional Directional Control Valve (with Pressure Compensation, Multiple Valve Series)

Solenoid Valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm) A-1.

Vickers. Vane Pumps. Double Thru-drive Vane Pumps. High speed, high pressure VQT Series for mobile equipment. Released 7/93

Chapter 10: Valves for Pipe Mounting

FULL RANGE PRESSURE COMPENSATING VARIABLE FLOW CONTROL

Hydraulic Screw-in Cartridge Valves (SiCV) Proportional valves Proportional solenoid valves for pressure and flow control

Sectional Directional Control Valve RS 220

SERIES 20 SECTIONAL DIRECTIONAL CONTROL VALVES INSTALLATION & USER GUIDE

Monobloc and Sectional Directional Control Valves

Solenoid valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm)

Series PAVC Variable Volume, Piston Pumps

VT modular. Modular System for LSC Manifold Valve Plates

VALVES HYDRAULIC SOLUTION SPECIALISTS DISCLAIMER

Pilot Operated Pressure Relief Valve Series R5V (Denison)

Contents. Directional Control Valve 2 Series CV Unibody. Page 3-4. General Information. Page 5. Technical data. Page 6. Performance Curves

LogSplitterPlans.Com

MCV106A. Hydraulic Displacment Control-PV DESCRIPTION FEATURES ORDERING INFORMATION. BLN Issued: March 1991

VIS (Valve-In-Star) Hydraulic Motor

Solutions. We Manufacture. H y d r a u l i c s. Eaton Medium Duty Piston Pump. h y d r a u l i c s

SERIES Waterman* DESCRIPTION FLOW PRESSURE PAGE NO.

Chapter 13: Application of Proportional Flow Control

PACKED SPOOL 4-WAY DIRECTIONAL CONTROL VALVE.

CONTROL FOCUSED TECHNOLOGY DRIVEN MODEL 5000 SECTIONAL VALVE 5000 VALVE SERIES

Proportional Valves MODEL DESCRIPTION FLOW CAVITY 4/3 PROPORTIONAL DIRECTIONAL VALVE 8 GPM C1040 PDFC-4M PDFC-4L

Lesson 5: Directional Control Valves

Test Which component has the highest Energy Density? A. Accumulator. B. Battery. C. Capacitor. D. Spring.

Pressure Control Valves. General Description. Specifications. Ordering Information

Transcription:

Directional Control Valves SECTIONAL BODY Model SV STANDARD FEATURES - Sections Per Valve Bank Differential Poppet Style Relief, Adjustable Load Checks On Each Section from 5 to 3 psi (Also available in Low Pressure Hard Chrome Plated Spools Version Adjustable from 5 to 5 psi) Compact Construction Power Beyond Capability Enhanced Metering Section Available in Reversible Handle both the High and Low Sections Mid-Inlet and Lock Valve Section available Flow Control Inlet SPECIFICATIONS Parallel or Series Circuit Construction Foot Mounting Pressure Rating Maximum Operating Temp...8 F Maximum Operating Pressure... 3 psi Weight Per Section Maximum Tank Pressure... 5 psi Inlet Section... Approx 3.75 Ibs Nominal Flow Rating...2 GPM Outlet Section... Approx 3.75 Ibs. Refer to Pressure Drop Curves. Work Section (Standard)... Approx 5.5 Ibs. Filtration: For general purpose valves, fluid Work Section (High)... Approx 8. Ibs. cleanliness should meet the ISO 44 9/7/4 level. For extended life or for pilot operated valves, the 8//3 fluid cleanliness level is recommended. V8 ATV 8-7-2-

ordering information: The following is a listing of valve sections available from stock on a standard basis. standard sections available: INLET SECTIONS ALL HAVE BOTH TOP AND SIDE INLET PORTS PART NO. RELIEF TYPE AND SETTING PORT SIZE SVI2 No Relief # SAE ORB (7/8-4 THD) SVI24 Adjustable Low Pressure Relief Set at PSI # SAE ORB (7/8-4 THD) SVI5 Adjustable High Pressure Relief Set At 2 PSI #8 SAE ORB (3/4- THD) SVI25 Adjustable High Pressure Relief Set at 2 PSI # SAE ORB (7/8-4 THD) WORK SECTIONS ALL HAVE #8 SAE ORB (3/4- THD) PORTS, LOAD CHECK AND STANDARD LEVER HANDLE PART NO. SPOOL TYPE AND ACTION SVWAA SVWBA SVWBB SVWCA SVWCB SVWDD SVLCA SVMES 3-Way Single Acting w/ Spring Center 4-Way Double Acting w/ Spring Center (Work Ports Blocked in Neutral) 4-Way Double Acting w/ 3 Position Detent (Work Ports Blocked in Neutral) 4-Way Motor Spool w/ Spring Center (Work Ports Open to Tank in Neutral 4-Way Motor Spool w/ 3 Position Detent (Work Ports Open to Tank in Neutral) 4-Way 4 Position Float w/ Spring Center and Float Detent 4-Way Spool w/ Spring Center (with Pilot Operated Checks on Both Work Ports) 4-Way Meter Spool w/ Spring Center (Work Ports Blocked in Neutral) PORT RELIEF WORK SECTIONS ALL HAVE #8 SAE ORB (3/4- THD) PORTS, LOAD CHECK AND STANDARD LEVER HANDLE. MODELS WITH RELIEF FACTORY SET AT 2 PSI AT 3 GPM. PART NO. SPOOL TYPE AND ACTION PORT RELIEFS SVHBAAA 4-Way Double Acting w/ Spring Center Port Relief Plugged SVHBAGG 4-Way Double Acting w/ Spring Center Adjustable 5-3 PSI SVHDDAA 4-Way 4 Position Float w/ Spring Center and Float Detent Port Relief Plugged SVHDDBB 4-Way 4 Position Float w/ Spring Center and Float Detent Shim Adjustable 5-3 PSI SVRESAA 4-Way Meter Spool w/ Spring Center Port Relief Plugged SVRESGG 4-Way Meter Spool w/ Spring Center Adjustable 5-3 PSI SVSGAGG 4-Way Double Acting Series w/ Spring Center Adjustable 5-3 PSI SVSGAAA 4-Way Double Acting Series w/ Spring Center Port Relief Plugged OUTLET SECTIONS ALL HAVE BOTH TOP AND SIDE OUTLET PORTS PART NO. EXHAUST OPTIONS PORT SIZE SVE Open Center Outlet w/ Conversion Plug #8 SAE ORB (3/4- THD) SVE2 Open Center Outlet w/ Conversion Plug # SAE ORB (7/8-4 THD) SVE22 Power Beyond Outlet w/ #8 SAE Beyond Port # SAE ORB (7/8-4 THD) SVE23 Closed Center Outlet # SAE ORB (7/8-4 THD) SVE2 Open Center Outlet Pressure Build-up Valve # SAE ORB (7/8-4 THD) SVE27 Power Beyond Pressure Build-up Valve # SAE ORB (7/8-4 THD) TIE ROD KITS TIE ROD TORQUE 5in-lbs ± in-lbs (2 /2 ft-lbs ±/2) PART NO. 4 Section* 42 2 Sections* 43 3 Sections* 44 4 Sections* 45 5 Sections* *Number of Work Sections special INLET AND OUTLET sections available: PART NO. 4 Sections* 47 7 Sections* 48 8 Sections* 49 9 Sections* 4 Sections* Sections other than standard models listed can be made to order. Use order code Matrix below to generate a model number that meets your requirements. If you prefer, contact your Sales Representative with your specific requirements and a model number will be assigned for you. This model number can be used for future orders. A minimum order quantity will apply to special valves. Please consult Sales Representative. INLET SECTIONS S V X X - X X X X PORT SIZE. #8 SAE ORB (3/4- THD) 2. # SAE ORB (7/8-4 THD) All inlet sections have top and side inlets. RELIEF SETTING (in PSI) RELIEF OPTION. No Relief Plug 4. Adj. Low Pressure 5-5 PSI 5. Adj. High Pressure 5-3 PSI. Plastic Plug in relief cavity. Use only when cartridge is to be installed at a later date. OUTLET SECTION S V E X X PORT SIZE. #8 SAE ORB (3/4- THD) 2. # SAE ORB (7/8-4 THD) Often used with no relief. Review application All outlet sections have top and side outlets. EXHAUST OPTION. Std. Open Center Outlet w/conversion Plug 2. Power Beyond Outlet w/#8 SAE Beyond Port 3. Closed Center Outlet Open Center Outlet Pressure Build-up 7. Power Beyond Pressure Build-up #8 SAE Beyond Port CATV 9-7-2- valve assemblies The Model SV sectional body directional control valve can be ordered as separate sections or as a complete factory tested assembly. This will need to be specified with each order. An assembly number will be assigned at the time of the order. This assembly number can then be used for future orders. ASSEMBLY MODEL NUMBER SVA-XXXX XXXX = Sequence of Numbers. This number will be assigned to final valve to be assembled and tested at the factory. Each new order or quote will be assigned a new assembly model number. Please use quotation sheet at the end of SV section. PRINCE MANUFACTURING CORPORATION P.O. BOX 7 NORTH SIOUX CITY, SOUTH DAKOTA 5749-7 URL: www.princehyd.com E-MAIL: prince@princehyd.com PHONE (5) 235-22 FAX (5) 235-82 O.E.M. CUSTOMER SERVICE: (5) 235-22 FAX (5) 235-82 DISTRIBUTOR CUSTOMER SERVICE: PHONE (5) 235-22 FAX (5) 27-3 SEE PAGE 4 OF THE STANDARD PRODUCT PRICE LIST FOR PRICING V9

special work sections available: Work Sections other than standard models listed can be made to order. Use order code Matrix below to generate a model number that meets your requirements. If you prefer, contact your Sales Representative with your specific requirements and a model number will be assigned for you. This model number can be used for future orders. A minimum order quantity will apply to special valves. Please consult Sales Representative. WORK SECTIONS SECTION TYPE W-Std. Work Section M-Metering Work Section 2 L-Work Section with Double P.O. Checks F-Fine Metering 3 PORT SIZE. #8 SAE ORB (3/4- THD). # SAE ORB (9/-8 THD) S V X X X X X SPOOL TYPE A-3-Way 3-Position B-4-Way 3-Position C-4-Way 3 Position Motor D-4-Way 4 Position Float E-4-Way 3 Position Metering (SVM only) F-3-Way 3 Position Metering (SVM only) J-4-Way 3 Position Fine Metering (SVF only). Lock Valve Section available only with Spool Option C.. Metering Section available only with Spool Options E or F. 3. Fine Metering available only with Spool Options J. PORT RELIEF WORK SECTIONS S V X X X X X X X SECTION TYPE H-Port Relief Section R-Port Relief Metering Section 2 S-Series Circuit Port Relief Section G-Port Relief Fine Metering Section 3 HANDLE OPTION. Standard Lever Handle 2. Less Handle Only 3. Less Complete Handle Assembly 4. Adjustable Handle 5. Tang Spool End Only. Clevis Spool End Only 7. Vertical Handle 8. Straight Handle 9. Blank for Optional Joystick Handle. Enclosed Handle 2. Extended Enclosed Handle SPOOL ACTION A-Spring Center (SVW & SVL only) B-3 Position Detent C-Friction Detent D-Spring Center w/float Detent (SVW only) E-Light Spring Center F-2 Position Detent Neutral and Out (No IN Position) G-2 Position (Center and Spool Out) - Spring Loaded to Spool Out (Pressure to B Port) Position H-2 Position (Center and Spool ln)-spring Loaded to Spool In (Pressure to A Port) Position J-S/C with MicroSwitch Bracket 2-Position (MicroSwitch not provided) K-S/C with MicroSwitch Bracket -Position (MicroSwitch not provided) (activates on spool out only) M-Spring Center Detent In N-Spring Center Detent Out R-Spring Center Pneumatic Actuator S-Spring Center (SVM & SVF) PORT RELIEF B OPTION A-Relief Cavity Plugged B-Non-Adjustable Direct Acting Relief 5-3 PSI C-Non-Adjustable Direct Acting Relief 5-5 PSI D-Anti-Cavitation Check E-Adjustable Combination Port Relief/Anti-Cavitation Check -25 PSI*** F-Non-Adjustable Combination Port Relief/Anti-Cavitation Check -25 PSI*** G-Adjustable Direct Acting Relief 5-3 PSI H-Adjustable Direct Acting Relief 5-5 PSI PORT RELIEF A OPTION A-Relief Cavity Plugged B-Non-Adjustable Direct Acting Relief 5-3 PSI C-Non-Adjustable Direct Acting Relief 5-5 PSI D-Anti-Cavitation Check **E-Adjustable Combination Port Relief/Anti-Cavitation Check -25 PSI*** F-Non-Adjustable Combination Port Relief/Anti-Cavitation Check -25 PSI*** **G-Adjustable Direct Acting Relief 5-3 PSI **H-Adjustable Direct Acting Relief 5-5 PSI ** Cannot be used on work sections with float option due to interference with handle. *** Do not use in applications that require low work port leakage. Max allowable leakage 5 in 3 /min @ psi. For Work Port Relief Settings Other Than Standard SVHBAGG-8-25 B PORT RELIEF PRESSURE IN HUNDREDS EXAMPLE: 25=25 PSI at 3 GPM All Port Reliefs set at 3 GPM PORT SIZE.#8 SAE ORB (3/4- THD) 2.# SAE ORB (9/-8 THD) SPOOL TYPE A-3-Way 3-Position B-4-Way 3-Position C-4-Way 3 Position Motor D-4-Way 4 Position Float E-4-Way 3 Position Metering (SVR only) F-3-Way 3 Position Metering (SVR only) G-4-Way 3 Position Series (SVS only) H-4-Way 3 Position Motor Series (SVS only) J- 4-Way 3 Position Fine Metering (SVG only) SPOOL ACTION A-Spring Center (SVH & SVS only) B- 3 Position Detent C-Friction Detent D- Spring Center w/ Float Detent (SVH only) E-Light Spring Center F-2 Position Detent Neutral and Out (No IN Position) J-S/C with Micro Switch Bracket 2-Position* K-S/C with MicroSwitch Bracket -Position* M-Spring Center Detent In N-Spring Center Detent Out R-Spring Center Pneumatic Actuator S-Spring Center (SVR & SVG) *MicroSwitch not provided HANDLE OPTION. Standard Lever Handle 2. Less Handle Only 3. Less Complete Handle Assembly 4. Adjustable Handle 5. Tang Spool End Only. Clevis Spool End Only 7. Vertical Handle A PORT RELIEF PRESSURE IN HUNDREDS 9. Blank for Optional Joystick Handle EXAMPLE: 8=8 PSI at 3 GPM 2. Extended Enclosed Handle All Port Reliefs set at 3 GPM CUSTOM SECTION: For OEM application custom sections can often be designed to meet your specifications. Special handles, spool, and spool actions are often easily made because of the SV valve s flexible design. Consult your sales representative with your specifications. V2 PRINCE MANUFACTURING CORPORATION P.O. BOX 7 NORTH SIOUX CITY, SOUTH DAKOTA 5749-7 URL: www.princehyd.com E-MAIL: prince@princehyd.com PHONE (5) 235-22 FAX (5) 235-82 O.E.M. CUSTOMER SERVICE: (5) 235-22 FAX (5) 235-82 DISTRIBUTOR CUSTOMER SERVICE: PHONE (5) 235-22 FAX (5) 27-3 SEE PAGE 5 OF THE STANDARD PRODUCT PRICE LIST FOR PRICING CATV 2-7-2-

field conversion kits, repair kits and relief cartridges SPOOL ATTACHMENT KITS 8 Spring Center Kit (except SVM) 82 3 Position Detent Kit 83 Friction Detent Kit 85 Float Detent Kit 83 Spring Center Detent In 837 Spring Center Detent Out 85 S/C w/micro-switch, 2 Position* 8 S/C w/micro-switch, Position* HANDLE KITS 8 Std. Handle Kit 832 Clevis Sub-Assy 85 Complete Handle Kit 83 Pin Kit 82 Vertical Handle Kit 828 Straight Handle Kit 87 Complete Adjustable Handle Kit *Bracket only, Micro-Switch is not provided. 8 Adjustable Handle Kit 855 Joystick Handle Kit Less Handle 833 Bent Joystick Handle Kit 87 Straight Joystick Handle Kit 88 Offset Joystick Handle Kit SEAL KITS 58 SVW/SVM Replacement Seal Kit 582 Inlet Seal Kit 583 Outlet Seal Kit 584 Between Section Seal Kit 58 SVH/SVR Replacement Seal Kit 589 SVL Replacement Seal Kit 58 SVS Replacement Seal Kit PORT RELIEFS 284 Port Relief Plug 283 Shim Adj. Port Relief 5-3 PSI 28 Shim Adj. Port Relief 5-5 PSI 282 Adj. Combination Port Relief/Anti-Cav Check -25 PSI performance curves 288 Shim Adj. Combination Port Relief/Anti-Cav Check -25 PSI 285 Anti-Cavitation Check 289 Adj. Port Relief 5-3 PSI 28 Adj. Port Relief 5-5 PSI 72.5 SHIM 722.33 SHIM 723. SHIM INLET RELIEFS 25 Inlet Relief Plug 253 Low Pressure Inlet Relief 252 High Pressure Inlet Relief OUTLET CARTRIDGES 243 Open Center Plug 28 #8 SAE Power Beyond Cart. 282 Closed Center Plug 288 Open Center Build-Up Cart. 289 Power Beyond Build-Up Cart. MISC. KITS 852 Load Check Kit PRESSURE DROP P TO T 2 SUS OIL AT F RELIEF VALVE CURVES PRESSURE DROP PSI 25 2 5 5 2 4 8 2 4 5 4 3 2 NO. OF WORK SECTIONS PRESSURE (PSI) 3 25 2 5 2 4 8 2 4 PRESSURE DROP PSI 75 5 25 PRESSURE DROP P TO A OR B NO. OF WORK SECTIONS PRESSURE DROP PSI 75 5 25 PRESSURE DROP A OR B TO T 4 2 NO. OF WORK SECTIONS 2 4 8 2 4 2 4 8 2 4 svs series section test data PRESSURE DROP PSI OPEN CENTER PRESSURE DROP P TO T 5 25 75 3 5 25 4 8 2 4 NO. OF WORK SECTIONS 2 SUS OIL AT F PRESSURE DROP PSI OPEN CENTER PRESSURE DROP P-A-B-T 3 25 3 2 5 5 4 8 2 4 NO. OF WORK SECTIONS CATV 2-7-2- PRINCE MANUFACTURING CORPORATION P.O. BOX 7 NORTH SIOUX CITY, SOUTH DAKOTA 5749-7 URL: www.princehyd.com E-MAIL: prince@princehyd.com PHONE (5) 235-22 FAX (5) 235-82 O.E.M. CUSTOMER SERVICE: (5) 235-22 FAX (5) 235-82 DISTRIBUTOR CUSTOMER SERVICE: PHONE (5) 235-22 FAX (5) 27-3 V2

dimensional data work W sections RK PO T 25 outlet cover B WORK PORT A WORK PORT.25 TYP.75.5 PART STAMPED N N MBER THIS IN THIS WILL TION CA BE STAMPED ION TYPICAL IN THIS OLOCATION TYPICAL FLOAT OPTION.9 2.8 O EL.7 Y WORK O SPOOL WORK TYP TRAVEL TYP O LOAT 25 FLOAT TO T WORK PTYP TYP..48 TO FLOAT TYP. SVW.72.25.44.72 MBER NONVERSION PLUG PLUG CA R PART NUMBER IONNUMBER WILL L BE BE ST STAMPED TH IN THIS S LO LOCATION XX SVEXX 9.9 4.94 E OP OUTLET SIDE E OUTLE OUTLET 53.25 2. 2.9.55.5 5.34 8.75 / inlet cover.3.88 SVH/SVR/ V SVG3 4. 3..44.72.5.75 TOP INLET.9 ART SIDE NUMBE NL T PART NUMBER WILL BE STAMPED IN THIS LOCATION.5 5.34..75 3.5.88 V SVL 3.44.72 3.25 2..75.3 SV XX 2.52 4.32 bottom view of mounting dimensions 4. 3..8 3.88 3/8-UNC THD 3 PLACES.78.44.5 5.34 88.75.3.88 S SVS 3.44.72 SEE CHART COLUMN B SEE CHART COLUMN A 4. 3..78 V22.5 TO 5.34.75 WORK O SPOOL WOR TYP TRAVEL TYP 28 5 5 TO WORK TYP. 22 52.5.22.5 5.34.75 V / V SVM/SVF 3..4 4 4.44.72 Number of Work Sections A B*.875 5.875 4.32 7.32 3 5.75 8.75 4 7.87.87 5 8.25.25.2 3.2 7.5 4.5 8 2.937 5.937 9 4.375 7.375 5.82 8.82 *With # plug in inlet & power beyond in outlet. PRINCE MANUFACTURING CORPORATION P.O. BOX 7 NORTH SIOUX CITY, SOUTH DAKOTA 5749-7 URL: www.princehyd.com E-MAIL: prince@princehyd.com PHONE (5) 235-22 FAX (5) 235-82 O.E.M. CUSTOMER SERVICE: (5) 235-22 FAX (5) 235-82 DISTRIBUTOR CUSTOMER SERVICE: PHONE (5) 235-22 FAX (5) 27-3 CATV 22-7-2-

typical stack dimensional data 7.44 2.5 5.58 2. SVEXX 2. C 59 THE ROD TORQUE 5 in-lbs + in - lbs 4 (2 /2 ft - lbs +/2.44 SIDE T OUTLET TOP OUTLET.47.44 9.3 2. 7 9.95.75 WER 8 59 POWER BEYOND PORT 3.7 SVE SVL S SVH\SVS SVM SVW -S2L.47 3.8 3. 3.88 SVI -T2Q 7. 5.88 5. C-35 SVIXX enclosed handle, options and 2 Durable die cast metal housing. Weather and oil resistant rubber boot. Reversible handle can be mounted in either a vertical or horizontal position. The extended handle option provides the necessary clearance for work port relief and lock cartridges. The extended handle option can also be used on the SVW and SVM, work sections when it is desired to keep handles aligned in an assembly with both low and high sections. 23 2 8.73 STANDARD SECTION 2.3 Float position Alternate parallel handle position.2 PORT RELIEF SECTION SVIXX SVIXX Handle option (SVW & SVM) Handle option 2 (SVH, SVL, SVS & SVR) CATV 23-7-2- PRINCE MANUFACTURING CORPORATION P.O. BOX 7 NORTH SIOUX CITY, SOUTH DAKOTA 5749-7 URL: www.princehyd.com E-MAIL: prince@princehyd.com PHONE (5) 235-22 FAX (5) 235-82 O.E.M. CUSTOMER SERVICE: (5) 235-22 FAX (5) 235-82 DISTRIBUTOR CUSTOMER SERVICE: PHONE (5) 235-22 FAX (5) 27-3 V23

parallel circuit svw, svm, SVF, svh, svr, SVG and svl work sections Parallel circuit sections are by far the most common. The SVW, SVM, SVF, OPEN OPEN CENTER CENTER PASSAGE SVH, SVR, SVG and SVL are all of parallel circuit construction. They can LOAD be combined together in any order in an assembly. When any one of the LOAD CHECK PARALLEL spools is shifted, it blocks off the open center passage through the valve. PARALLEL CIRCUIT T CORE The oil then flows into the parallel circuit core making oil available to all spools. If more than one spool is fully shifted, the oil will go to the spool with the lowest pressure requirements. However, it is possible to meter the flow to the spool with the lease load and provide flow to two unequal loads. ENHANCED METERING SECTIONS B B B The SVM, SVF, SVR and SVG sections have metering notches machined P into the spool to allow for better feathering of a load. The spool travel for these sections is also a little longer at.28 vs..25 for the standard sections. In addition to the metering notches in the spool, the lands in the SVF and SVG bodies have been machined to give more precise control over the flow. The metering notches in the SVF and SVG have been optimized for flows of gpm or less. For enhanced metering on higher A A A T flows, it is recommended that the SVM or SVR be used. CONVERSION O V PLUG LOCK SECTIONS The SVL section combines both a 4-way directional valve and a double pilot operated check valve. This provides very low leakage when the spool is in neutral. When the spool is shifted, oil is directed through a work port check to the cylinder. Pressure on the work port applies pressure to the shuttle spool, opening the opposite check valve and allowing oil to return into the valve. Depending on load pressures, the metering of the spool may be affected. In some cases a one way restrictor in a work port may be beneficial. series circuit svs work sections A series circuit valve is most commonly used to control more than one hydraulic component simultaneously. The entire circuit flow is available to each valve section that is actuated. In a two spool series valve with both spools actuated, the oil flows from the inlet to the work port of the first section. The return flow of the first section is directed to the open center core of the second section. TANK RETURN TANK RETURN (In a parallel valve the return oil from the work port is directed to the tank core.) From the open center core of the second section, PORT POR A PORT POR A the oil flows to the work port with the return oil going to the outlet. In a series circuit valve, the summation of the pressures required for each work section will equal the total pressure required for the circuit. The total pressure required must not exceed the system relief setting or the pump pressure rating. It is not required to have a SV Series section as the last section, unless series flow is required to a downstream valve. In this application, a power beyond plug must be used in the outlet section. COMBINED SERIES / PARALLEL CIRCUITS SERIES SECTION SERIES SECTION The SV Series circuit valve sections may be stacked with SV parallel circuit valve sections. This allows both series and parallel control in the same valve assembly. In the valve assembly shown below, the first, third and fourth sections are parallel. The second section is series. The first parallel section has priority over all downstream valves. When the spool of the first parallel section is actuated, the return oil from the work port is directed to the tank core, thus oil flow to downstream sections is cut off. The second and third sections are in series with each other as is the second and fourth sections. The third and fourth sections are in parallel with each other. SERIES MOTOR SPOOL The SV Series Motor Spool provides control of reversible hydraulic motors. Both work ports are connected to the open center core in the neutral position. It should be noted that in the neutral position, the work ports will be equally pressurized to the same pressure that is required TANK RETURN TANK RETURN TANK RETURN TANK RETURN of any downstream valve sections and that a work port relief in the section will also limit the pressure of any PORT A PORT A PORT A other sections in the valve. The series motor spool should PORT A not be used to control a hydraulic cylinder as unwanted cylinder drift may occur in the neutral position. CLOSED CENTER APPLICATIONS The SV Series Circuit Valve sections cannot be used in a closed center valve assembly. PARALLEL SECTION SERIES SECTION PARALLEL SECTION PARALLEL SECTION V24 PRINCE MANUFACTURING CORPORATION P.O. BOX 7 NORTH SIOUX CITY, SOUTH DAKOTA 5749-7 URL: www.princehyd.com E-MAIL: prince@princehyd.com PHONE (5) 235-22 FAX (5) 235-82 O.E.M. CUSTOMER SERVICE: (5) 235-22 FAX (5) 235-82 DISTRIBUTOR CUSTOMER SERVICE: PHONE (5) 235-22 FAX (5) 27-3 CATV 24-7-2-

work sections SV WORK PORT RELIEF SV WORK PORT RELIEFS, OPTION B, C, G, & H CAN BE ORDERED PRETESTED. USE ORDER CODE AT RIGHT PR MODEL NUMBER - O - PORT SIZE RELIEF TYPE PRESSURE SETTING H- ADJUSTABLE SPECIFY RELIEF CARTRIDGE 5-3 TAB E PSI RELI PRESSURE. F E ONLY L- ADJUSTABLE P I LEAVE SURE. BLANK FOR 5-5 TABLE PSI STANDARD BLANK FOR SETTINGS. NH- 5 NON-ADJUSTABLE 5-3 JU ABLE PSI STANDARD SETTING: - NL- NON-ADJUSTABLE P I S ARD 2 SETTING: PSI for H and NH JUS 2 5-5 ABLE PSI for PSI and for N L and NL CATV 25-7-2- PRINCE MANUFACTURING CORPORATION P.O. BOX 7 NORTH SIOUX CITY, SOUTH DAKOTA 5749-7 URL: www.princehyd.com E-MAIL: prince@princehyd.com PHONE (5) 235-22 FAX (5) 235-82 O.E.M. CUSTOMER SERVICE: (5) 235-22 FAX (5) 235-82 DISTRIBUTOR CUSTOMER SERVICE: PHONE (5) 235-22 FAX (5) 27-3 V25

sv inlet relief options OPTION NO RELIEF TOP INLET This option provides no built in relief. This is used when a relief is provided elsewhere in the system or in a closed center application. This plug can be replaced with a relief cartridge at a later date. OPTION 4 LOW PRESSURE ADJUSTABLE RELIEF This option provides for a differential poppet relief adjustable from 5-5 PSI. Set at PSI @ GPM. OPTION 5 HIGH PRESSURE ADJUSTABLE SVIXX RELIEF This option provides for a differential poppet relief adjustable from SIDE INLET 5-3 PSI. Set at 2 PSI @ GPM. The differential poppet relief provides smooth quiet operation with high cracking pressure. RELIEF CARTRIDGES VIXX CAN BE ORDERED PRETESTED SEE RV-OX RELIEF, PAGE V5. sv outlet cover options POWER BEYOND PORT SVEXX TOP OUTLET SIDE OUTLET "CC" STAMPED ON END OF CLOSED CENTER PLUG OPTION 3 CLOSED CENTER OUTLET This option provides for closed center operation. This is typically used with a variable displacement pressure compensated pump or in a system with an unloading valve. When the spools are in neutral the inlet port is blocked. Closed center can also be accomplished by plugging the power beyond port of option 2.. OPTION S STANDARD XX OPEN CEN- TER OUTLET WITH CONVERSION PLUG This is the standard outlet option. This option allows for conversion in the field for power beyond or closed center applications. When spools are in neutral the inlet is unloaded to tank. OPTION 2 POWER BEYOND OUTLET WITH #8 SAE BEYOND PORT This option provides for a high pressure power beyond port. This would be used if a valve is to be added down stream. THE OUTLET PORT MUST STILL BE CONNECTED TO TANK. When spools are in neutral the inlet is connected to the power beyond port..38 2. PLEASE NOTE that this closed center option does not provide for the drain off of standby spool leakage. This can allow a very small amount of oil to enter the work ports when in neutral. OPTION OPEN CENTER OUTLET PRESSURE BUILD- UP VALVE FOR SOLENOID OPTION This option directs oil from open center core thru pressure build-up valve and then to tank. See solenoid section for description of operation. OPTION 7 POWER BEYOND PRESSURE BUILD-UP VALVE FOR SOLENOID OPTION This option directs oil from inlet thru pressure build-up valve and then downstream. This pressure build-up valve provides a #8 SAE power beyond port. The outlet must be connected to tank. sv mid-inlet section MID INLET PORT MID INLET RELIEF SPACER SPLIT MID-INLET SHOWN CAN BE CONVERTED TO COMBINED MID-INLET BY MOVING SPACER TO OPPOSITE END POWER CORE BLOCKING PLATE INSTALLS IN POWER CORE BETWEEN MID INLET & UPSTREAM SECTION. SVIM X X - X X X X Last Four Digits Specify A Non-Standard Relief Pressure. When blank, refer to standard setting -No Relief -SHIM Adjustable 5-5 PSI Std. Setting PSI @ GPM 3-SHIM Adjustable 5-3 PSI Std. Setting 2 PSI @ GPM 4-Adjustable 5-5 PSI Std. Setting PSI @ GPM 5-Adjustable 5-3 PSI Std. Setting 2 PSI @ GPM C-Combined Flow Mid-Inlet S-Split Flow Mid-Inlet (not available after a series section) See Section View at left. Note Location of Spacer, Part Number 7235. Port Size #8 SAE ORB (3/4- THD) DESCRIPTION: A Mid-Inlet provides an inlet port for a second pump mid stream in the valve stack. A relief can be provided in this section. With the combined flow the flow from both pumps is available to the downstream sections when all the work sections upstream are in neutral. The split flow completely separates the two pump flows. The common tank passage is all that is shared between the two pump flows. Note: Split flow mid inlet is not available when used after a series section and the core block plate is not used after a series section. V2 PRINCE MANUFACTURING CORPORATION P.O. BOX 7 NORTH SIOUX CITY, SOUTH DAKOTA 5749-7 URL: www.princehyd.com E-MAIL: prince@princehyd.com PHONE (5) 235-22 FAX (5) 235-82 O.E.M. CUSTOMER SERVICE: (5) 235-22 FAX (5) 235-82 DISTRIBUTOR CUSTOMER SERVICE: PHONE (5) 235-22 FAX (5) 27-3 CATV 2-7-2-

48 3 2 4 8 9 sv flow control inlet section PORT SIZE - Side and End Inlet # SAE ORB 2- Side and End Inlet # SAE ORB, with #8 SAE ORB External EF Circuit IN S V F X X X X X X RELIEF VALVE - No Relief 2- Direct acting non-adjustable 5-5 psi set at psi* 3- Direct acting non-adjustable 5-3 psi set at 2 psi* 4- Direct acting adjustable 5-5 psi set at psi* 5- Direct acting adjustable 5-3 psi set at 2 psi* *for other settings please specify, i.e. SV F5P2Q-27 # is Rear set I at le 27 Port psi # Rear Inlet Port # Side Inlet Port 2. IN IN EF SVIFXXX-XX Optional #8 EF Port SOLENOID OPTION Omit for Flow Control Option M 2Q-2VDC Double Spade Coil 24Q-24VDC Double Spade Coil 2H-2VDC DIN 435 Coil 24H - 24VDC DIN 435 Coil 2L-2VDC Double Lead Wire Coil 24L - 24VDC Double Lead Wire Coil 2W -2VDC Double Lead Wire w/ Weatherpak Connector Coil 24W - 24VDC Double Lead Wire w/ Weatherpak Connector Coil FLOW CONTROL OPTION M- Manual Flow Control P- Electro-Proportional U- Solenoid Unloading C-7 IN 5.8 Option P- Proportional flow control with manual 5 8 override The SVIF Flow Control Inlet is interchangeable with the standard SV inlet section. FLOW CONTROL OPTIONS: P OPTION incorporates a solenoid operated, electrically variable pressurecompensated flow control cartridge. With the solenoid de-energized, all of the inlet flow is diverted to the tank core/ef port. By increasing the current through the solenoid, the flow directed to the power core and downstream sections will be proportionally increased, (the maximum rating of the cartridge is gpm at 5 ma) Control current is normally provided via a controller card providing, a PWM signal. U OPTION incorporates a solenoid operated, unloader cartridge. With the solenoid de-energized, all of the inlet flow is diverted to the tank core/ef port. With the solenoid energized all the inlet flow is directed to the power core and downstream sections. M portional OPTION flow incorporates a manually manual operated ove pressure-compensated ide flow control cartridge. With the control knob turned fully in (clockwise), all of the inlet flow is diverted to the tank core/ EF port. By turning the flow control knob counter clockwise, the inlet flow directed to the power core and downstream sections is proportionally increased. Approximately 5 revolutions varies flow from no flow to full flow, PORT OPTION 2 The flow being directed to the tank core/ef port may be utilized by a second circuit by inserting a /4 pipe plug into the tank core passage on the seal side of the casting and then connecting the EF port to the second circuit. PRESSURE CORE CONTROL OPTION P CIRCUIT PRESSURE SCHEMATIC O PRESSURE CORE CORE CONTROL OPT POPTION U SCHEMA CIRCUIT P SCHEMATIC SSURE C SURE PRESSURE CORE CORE CONTROL OL OPTIO OPTION U M CIRCUIT T SCHEMATIC PRESSURE SCHEMATIC C proportional controller box (for use with SVIFP flow control inlet), part no. 7348 The proportional controller box is used to provide an adjustable electrical signal to a proportional solenoid on the SVIFP inlet. Once the dial is set, the regulated flow through the valve should remain approximately constant regardless of pressure. Within the operating range, flow varies approximately linearly with dial rotation. CONNECTIONS AND OPERATION: *Connect leads to the power supply and solenoid. Power supply should be between 9 and 32 VDC. *With the power off, the inlet flow is directed to the tank (or excess flow port). *To provide power to the control, move the power switch to ON. -Bl (Green k LED is ON when control is powered). *Minimum flow is directed into the valve when on the dial is aligned with the center mark. Maximum flow is directed into the valve when Redon the dial is aligned with the center mark. *Clockwise rotation increases flow. *Typically, no adjustments are needed for operation, (l-min and l-max pots are preset for the normal maximum and minimum flows) -Black +Red OFF ON Power Sw ch Powe npu RED+ BLACK Pow r OK (2.5) (4.88) Pr nce Manufacturing Corpo ation 5 7 SOL Ou pu (5.) To proportional coil. Coil does not have polarity. (4.3) (.75) (.24) Mount using three #-32 screws (not included) (5.75) Control comes # 3 with screws ft (not of inc cable uded) for power leads and ft of cable for coil leads. Control box protection rating is IP7. CATV 27-7-2- PRINCE MANUFACTURING CORPORATION P.O. BOX 7 NORTH SIOUX CITY, SOUTH DAKOTA 5749-7 URL: www.princehyd.com E-MAIL: prince@princehyd.com PHONE (5) 235-22 FAX (5) 235-82 O.E.M. CUSTOMER SERVICE: (5) 235-22 FAX (5) 235-82 DISTRIBUTOR CUSTOMER SERVICE: PHONE (5) 235-22 FAX (5) 27-3 SEE PAGE 5 OF THE STANDARD PRODUCT PRICE LIST FOR PRICING V27

joystick handle for model sv stack valve HANDLE BACK 5th SPOOL OUT S E DET L T HANDLE LEFT th SPOOL HAND IN HANDLE UT RIGHT th SPOOL OUT T H NDLE SHOWN SEE DETAIL AT LEFT HANDLE VIEWED FROM TOP HANDLE IN FRONT 5th SPOOL HAND IN This is a special handle for the model SV stack valve that allows the spools of two adjacent sections to be operated by one common handle. The spools can be operated independently HANDLE HANDLE V E or D EWFRO D R simultaneously OPM T P depending on handle HANDLE HANDLE movement R NT RONT 5th SPO 5th The OOL N Noption is normally used on spring center to neutral sections, but can also be used on other sections such as float sections. This handle is normally installed on valves assembled at the factory but can be installed on work sections that have handle option 3 or 9. The drawing at right shows two joysticks with offset handles installed on a six section valve. When two joysticks are installed on the same valve assembly it is recommended that there be two standard sections between them to prevent handle interference. A two section spacer is available, part no. 382. OFFSET HANDLE SHOWN Please refer to these part numbers and state which sections the handle is to be installed on when ordering a valve assembly. This handle can be installed in the field to work sections with handle option 3 (no handle). JOYSTICK ASSEMBLY W/STRAIGHT HANDLE: ASSEMBLED ON VALVE...SVJS KIT... 87 JOYSTICK ASSEMBLY W/OFFSET HANDLE: ASSEMBLED ON VALVE...SVJO KIT...88 JOYSTICK ASSEMBLY W/BENT HANDLE: ASSEMBLED ON VALVE...SVJB KIT...833 A molded rubber boot (73) is available for the joystick. ONE WAY WORK PORT RESTRICTOR FOR SVH, SVM, SVR, & SVL WORK SECTIONS This restrictor will restrict oil in one direction and allow free flow in the opposite direction. This restrictor consists of an orifice plate that simply drops into the #8 SAE work port of a SVH, SVM, SVR, & SVL work section. ONE WAY WORK PORT RESTRICTOR FOR SVW WORK SECTIONS This restrictor will restrict oil in one direction and allow free flow in the opposite direction. This restrictor consists of the orifice plate as described at left and an adapter fitting that allow use in the standard SVW #8 SAE work port. Restricted Flow Free Flow Restricted Flow Free Flow ORDERING INFORMATION HEX BRASS RESTRICTOR # SAE 9/-8 #8 SAE 3/4-78XXX 785XXX SQUARE STEEL RESTRICTOR 8XXX CONICAL SPRING The last three digits of part number are the orifice size in thousandths of an inch. EXAMPLE: # SAE 9/-8THD #8 SAE 3/4-THD 782 7852.2 ORIFICE 7825 78525.25 ORIFICE 78 785 NO ORIFICE ORDERING INFORMATION ADAPTER W/HEX BRASS RESTRICTOR # SAE 9/-8 #8 SAE 3/4-28XXX 8XXX ADAPTER WITH SQUARE STEEL 82XXX RESTRICTOR AND CONICAL SPRING The last three digits of part number are the orifice size in thousandths of an inch. EXAMPLE: # SAE 9/-8THD #8 SAE 3/4-THD 282 82.2 ORIFICE 2825 825.25 ORIFICE 28 8 NO ORIFICE V28 PRINCE MANUFACTURING CORPORATION P.O. BOX 7 NORTH SIOUX CITY, SOUTH DAKOTA 5749-7 URL: www.princehyd.com E-MAIL: prince@princehyd.com PHONE (5) 235-22 FAX (5) 235-82 O.E.M. CUSTOMER SERVICE: (5) 235-22 FAX (5) 235-82 DISTRIBUTOR CUSTOMER SERVICE: PHONE (5) 235-22 FAX (5) 27-3 CATV 28-7-2-