GP Dimming Panels 230 Volt (CE)

Similar documents
LP Dimming Panels. GRAFIK Systems

GP Dimming Panels. GRAFIK Systems SPECIFICATION SUBMITTAL

GP Dimming Panels 230 Volt (CE)

LCP128T Spec Grade Dimming System

Phase-Adaptive Power Module

3-Wire Fluorescent Power Module

Phase-Adaptive Power Module with 3-Wire Fluorescent Input

Adaptive Power Module

DIN Rail Power Module

DIN Power Module - Phase Adaptive

Adaptive Power Module

Phase-Adaptive Power Module

Wired Vareo Local Lighting Controls

Wired Maestro Local Controls

SAVE THESE INSTRUCTIONS

User Manual JS-ICON. 624 ARCH Dimmer Rack. JOHNSON SYSTEMS INC. Spring

Switching Power Module

Installation & User Instructions

ALD Dimmer Enclosures

TOPAZ 24 DIMMER RACK INSTALLATION & MAINTENANCE GUIDE (Part # LIT A)

GRX-TVI Ten Volt Interface

INSTALLATION. **Microprocessor Status LED:

TOPAZ 12 WALL PACK INSTALLATION & MAINTENANCE GUIDE (Part # LIT A)

GRX-TVI Ten Volt Interface

GRX-TVI Ten Volt Interface

Controls. CONTROLS AND ACCESSORIES PRODUCT FAMILY FEATURES DIMMERS DIMENSIONS SPECIFICATION SERIES STANDARD FEATURES

SAVE THESE INSTRUCTIONS

EcoSystemR Multiple Control Input Ballasts

EcoSystem Multiple Control Input Ballasts

A.C.E.S. Series ACES 3 & 6 MODULE PANELS. System Manual. Touch-Plate Lighting Controls. ACES 3 & 6 Module System Manual

EcoSystem Dimming Power Module for 3-wire Lutron Dimming Ballasts. EcoSystem One-Line. EcoSystem C5-BMJ-16A. EcoSystem Dimming Module

HomeWorksR QS Wired MaestroR Architectural Local Controls

Maestro Wireless Dimmers and Switches

SO-SVCN- - GRAFIK Systems Sivoia QEDTM Controller

Ecosystem 5 Percent 3-Wire and Ecosystem Digital Link Controlled T4 Compact, 1 Lamp, Ballast Factor Of 0.95, K-Can, Studded, 26/32W

EcoSystem Multiple Control Input Ballasts

User Manual. Solar Charge Controller 3KW

Fluorescent (non-capacitive) Metal Halide 10A. 2 Any load circuit can be connected to any phase.

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

JBE LED2000 INDUSTRIAL SOLUTIONS FOR LED & INCANDESCENT MAINS LIGHTING FLICKER FREE TRAILING EDGE DIMMER

Installation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual

Industry Compliance The cabinet and modules are Listed to applicable UL Standards and requirements by Underwriters Laboratories Inc.

Application Description

Hi-lume LED Overview. LED Dimming Driver Hi-lume LED Architectural Dimming

AT30 SERIES BATTERY CHARGER

Advantage-D. Operating Instructions and Maintenance Manual. Central Vacuum Systems (Expandable/Modular Models) (Ver.

Elegance Electrician s Installation Guide

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

Maestro Wireless Dimmers and Switches

General information about motor protection

4000 Series Slider Control Units GRXSLD 4103/4104/4106/4108 CAUTION! Description. System Specifications. Installation Instructions Occupant Copy

TECHNICAL DATA SHEET KVA UPS Systemss

Domae. The right solution for distribution boards

FL ballasts Electronic fixed output. PC BASIC sl, 4 28 W PC BASIC

TVE Overview. Lighting Management Dimming. Fluorescent Dimming Ballasts

Technical Data Sheets

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

AXA DALI P20. DALI Broadcast Controller. Installation Manual

Art. No. EC-315. Art. No. EC-330. Art. No. EC-340 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2

User Manual Solar Charge Controller 3KW

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

PD404-AN V analog control 4 Channel x 500 W Dimmer & Switch Packs ANALOG 0-10 V. Serial Number

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual

GP12 TECHNICAL MANUAL

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

Vive Maestro Wireless Dimmers and Switches

Number 9 January SECTION 1 Dimming of T12 Fluorescent lamps 2. SECTION 2 Dimming of T8 Fluorescent lamps 4. SECTION 3 Do's and Don'ts 6

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

SAVE THESE INSTRUCTIONS

EcoSystemT 5-Series LED Driver ( V~, CE)

Installation Instructions Please Read Before Installing. Overview. Important Notes. Designer-Style Maestro Remotes HD-RD, -RS 120/127 V ~, 50/60 Hz

CTRC Series Flexible Rogowski Current Transformer - Installation Guide

P90L-ISO6MB & ISO10MB

QS Motor Group Controller QSE-CI-4M-D 4-Output AC Motor Controller. Energi Savr NodeTM Unit. seetouchr QS Wallstation. Wireless Communication

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

Sunburst SB2400 Dimmer Rack and Receiver. Version 1.02 P/N F371

Bulletin 871P Can Sensors

Document: PRODSPEC-140 Revision: G DCN No Date: October 1, 2014 Product: 10-amp EnerGenius NRG Battery Charger

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

AT EVO SERIES BATTERY CHARGER

Residential Systems Control of LED Lighting (120V)

2.7. IT system floor-standing distribution cabinet Series -IPS-F

Installation Instructions

Midwest Dry Type Transformers

New dimming drivers are compatible with most wall dimmers for % light control. For non-dimming

9/16/2010. Chapter , The McGraw-Hill Companies, Inc. TRANSMISSION SYSTEMS. 2010, The McGraw-Hill Companies, Inc.

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

AIR COOLED RECTIFIER SPECIFICATION S-50-A

PRODUCTS: POWER SUPPLY

K25000 & KD25000 Series

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy

Wiring Diagram Index. Find product, model #, and wiring diagram # Then find wiring diagrams on pgs

HomeWorks QS Designer RF Maestro Local Controls

SAVE THESE INSTRUCTIONS

Gas Insulated Metal-clad Switchgear, HMGS!

Compact SE Overview. High-Performance Dimming. Ballast

3-Wire Control, 220/240 Volt T-8 Linear, T-4 Quad Tube and T-5 Twin Tube Lamps

Transcription:

GAFIK Systems 30 Volt (CE) gp- 03.0.04 GP3/4 Mini Panels GP8-4 Standard-Size Panels provide power and dimming for up to 4 load circuits and control any light source, including full-conduction non-dim. Models available with: 30V input power. 3 to 4 circuits. Different feed types and breakers. work with: GAFIK Eye 4000 Control Units. GAFIK 5000TM, GAFIK 6000, and GAFIK 7000 Systems. LP Dimming Panels. XP SoftswitchTM Panels. DMX5 dimming systems via the LINKTM option.

GAFIK Systems Specifications - 30 Volt (CE) gp-5 03.0.04 Standards Complies with CE. Power Input power: 30V, 50/60Hz, phase-to-neutral. Branch Circuit Capacity: Number of Circuits: 3-4 Branch Circuit Breakers: IEC-rated thermal magnetic. AIC rating (other ratings available): 6,000A Lightning strike protection: Meets ANSI/IEEE standard 6.4-980. Can withstand voltage surges of up to 6000V and current surges of up to 3000A. 0-year power failure memory: Automatically restores lighting to scene selected prior to power interruption. Sources/Load Types Operates these sources with a smooth continuous Square Law dimming curve or on a full conduction non-dim basis: Incandescent (Tungsten)/Halogen Magnetic Low Voltage Transformer Electronic Low Voltage Transformer Lutron Electronic Fluorescent Dimming Ballasts Magnetic Fluorescent Lamp Ballasts Optional modules allow for control of 0-0V, DSI, and PWM load types. Operates HID sources on a full conduction non-dim basis. Internal: Prewired by Lutron. System communications: Lowvoltage Class (PELV) wiring connects Dimming Panels to other components. Line (mains) voltage: Feed, load, and control circuit wiring only. No other wiring or assembly required. Filter Chokes Load current rise time is measured at a 90 degree conduction angle, with 0V input power. 0-90% of load current waveform: - 350µSec rise time at 50% dimmer capacity. - 400µSec rise time at 00% dimmer capacity. 0-00% of load current waveform: - 55µSec rise time at 50% dimmer capacity. - 600µSec rise time at 00% dimmer capacity. At no point in the waveform can the rate of current change exceed 300mA per µsec. Consult Lutron for higher rise time options. Dimming Cards Panel current ratings are listed for continuous operation. TISSTM filter circuit technology compensates for incoming line voltage variations: No visible flicker with +/-% change in MS voltage/cycle and +/-% Hz change in frequency/second. Arcless-relay air gap-off switches (one per load circuit) ensure open load circuits when off function selected. Eliminate arcing at mechanical contacts when loads are switched. Physical Design Enclosure: NEMA-Type (Type available upon request), IP-0 protection; #6 U.S. Gauge Steel. Indoors only. Weight: 30-75 pounds (4-80kg). Mounting: Surface mount only. Allow space for ventilating. Environment/Heat Dissipation Patented, ribbed aluminum heat sink base cools Panel by convection. No fans. 3-04 F (0-40 C). elative humidity less than 90% non-condensing. everse-phase control transformers require an ELVI Power Interface. Check phase with transformer manufacturer.

GAFIK Systems gp-8 03.0.04 Anatomy of a GP Model Number G P - 3 0 4 I S - 0 C E - C G P - _ Prefix Number of Load Circuits Voltage Feed Type Panel Feed Custom Panel Suffix egion Suffix Branch Circuit Breakers Prefix: GP for GP Dimming Panel Number of Load Circuits: Indicates number of load circuits in the panel Voltage: 30 for CE Feed Type: for phase wire 4 for 3 phase 4 wire Panel Feed: IS for Isolator Switch Branch Circuit Breakers: 0 for branch circuit breakers egion Suffix: CE for 30 V Custom Panel Suffix: Indicates panel with special options

GAFIK Systems gp-4 03.0.04 GP3/4 Mini Models Only standard panels listed. Consult Lutron for further options. 30V (CE) Power Number Of Circuits Feed Type Maximum Feed Panel Feed/ Branch Circuit Breakers GP3 Ø, W 3Ø, 4W 30A GP4 Feed Through GP8-4 Standard-Size Models Only standard panels listed. Consult Lutron for further options. 30V Power Number Of Circuits Feed Type Panel Feed Maximum Feed Branch Circuit Breakers GP8 GP GP6 Ø, W 3Ø, 4W 3Ø, 4W 3Ø, 4W Isolator Switch Isolator Switch Isolator Switch Isolator Switch 5A 5A 5A 5A GP0 3Ø, 4W Isolator Switch 5A GP4 3Ø, 4W Isolator Switch 5A 30V (CE) Mains CE Panels are listed as appliances. A distribution panel must provide a main circuit breaker that does not exceed the rating of the panel. Breakers located in distribution panel supplied by others.

GAFIK Systems gp-6 03.0.04 Dimensions for GP3/4 Mini Panels Top View 5 /8 (30 mm) 3 5/8 (9 mm) 6 /4 (60 mm) 5/8 (4 mm) Class (PELV) Left Side View Front View 9 5/8 (44 mm) ight Side View 5 /4 (33 mm) 3/6 (30 mm) 8 8" (457mm) 9/" / (495mm) /8" /8 (537mm) /8 (9 mm) /8 (9 mm) 3/4 (70 mm) (79 mm) Keyhole accepts a maximum of /4 (6mm) mounting bolt. #0 M6 recommended. 3/4 (70 mm) Bottom View Load Circuit Feed 3/4 (70 mm) / (38 mm) 5 / (40 mm) / (38 mm)

GAFIK Systems Dimensions for GP8-4 Standard-Size Panels gp-7 03.0.04 Top View 8 (7 mm) Suggested feed wiring entry Suggested load wiring entry 4 (00 mm) Left Side (50 mm) Front View (50 mm) emovable top cover is shipped in the same box as the panel. ight Side 37 (940 mm) 33 (838 mm) 35 (889 mm) 3 (330 mm) Keyhole accepts a maximum of 5/6" (8 mm) mounting bolt (/4" (m8) recommended). Class /PELV entry knockout is 7/8" dia. ( mm) (304 mm) Bottom View (50 mm) equired control wiring entry (304 mm)

GAFIK Systems GP3/4 Mini Panel Mounting gp- 03.0.04 Surface mount indoors. Panel generates heat. Mount only where ambient temperature will be 0-40 C (3-04 F). This equipment is air cooled. Do not block vents or warranty will be void. Leave " (3cm) clearances above, below, and in front of Panel. No clearance necessary on sides. einforce wall structure for weight and local codes. GP3/4 Front View Terminal Blocks for Load Circuits Class (PELV) GP3/4 Side View " (3cm) minimum top and front Panel GP3/4 Maximum BTUs/Hour 685 Weight (without packaging) 30 lbs. (4kg) Branch Circuit Breakers Dimming Panels will hum slightly and internal relays will click while in operation. Mount where audible noise is acceptable. Mount Panels so line (mains) voltage wiring is at least 6 feet (.8m) from sound or electronic equipment and wiring. GP Panels must be mounted within 7 of true vertical. Load Circuit Feed aceway " (3cm) minimum For maximum Feed and Wire Sizes, consult Overview page. Water damages Panels! Install Panels in a location where they will not get wet.

GAFIK Systems GP8-4 Standard-Size Panel Mounting gp- 03.0.04 Surface mount indoors. Panel generates heat. Mount only where ambient temperature will be 0-40 C (3-04 F). This equipment is air cooled. Do not block vents or warranty will be void. Leave " (3cm) clearances above, below, and in front of Panel. Leave clearance on sides for Class (PELV) wiring. einforce wall structure for weight and local codes. Panel GP8 GP GP6 GP0 GP4 Maximum BTUs/Hour 365 045 75 3405 4085 Weight (without packaging) 5 lbs. (5kg) 30 lbs. (59kg) 45 lbs. (66kg) 60 lbs. (73kg) 75 lbs. (80kg) Dimming Panels will hum slightly and internal relays will click while in operation. Mount where audible noise is acceptable. Mount Panels so line (mains) voltage wiring is at least 6 feet (.8m) from sound or electronic equipment and wiring. GP Panels must be mounted within 7 of true vertical. GP8-4 Front View Feed aceway Main Lugs or Main Breaker. Load Circuit " (3cm) minimum top and front Terminal Blocks for Load Circuits Class (PELV) GP8-4 Side View air flow " (3cm) minimum For maximum Feed and Wire Sizes, consult Overview page. Water damages Panels! Install Panels in a location where they will not get wet.

GAFIK Systems gp-6 03.0.04 GP3 Mini Panel Overview 30 Volt (CE) Wire Sizes Power Feed: #8 AWG (.0mm ) to #4 AWG (5.0mm ) Neutral Feed: #4 AWG (.0mm ) to #6 AWG (0.0mm ) Dimmed Hot/Live: #4 AWG (.0mm ) to #0 AWG (4.0mm ) Load Neutral: #4 AWG (.0mm ) to #6 AWG (0.0mm ) Control Typical Load Circuit Bypass Jumpers - Do Not emove DL SL L DL SL L DL 3 SL 3 L 3 Branch Circuit Breakers Load Terminal Block Dimmed Hot/Live Load Neutral Ground Tips Wire the GP3 similar to wiring a lighting Distribution Panel: un feed and load wiring. No other wiring or assembly required. Common Neutrals are not permitted. un separate Neutrals for each load circuit. The GP3 can provide temporary lighting: Wire all loads. Do not remove the bypass jumpers that protect the Dimming Modules. Use Branch Circuit Breakers to switch lights on and off. Neutral Feed Power Feed (Hot/Live)

GAFIK Systems gp-9 03.0.04 GP4 Mini Panel Overview 30 Volt (CE) Wire Sizes Power Feed: #4 AWG (.0mm ) to #0 AWG (4.0mm ) Neutral Feed: #4 AWG (.0mm ) to #0 AWG (4.0mm ) Dimmed Hot/Live: #4 AWG (.0mm ) to #0 AWG (4.0mm ) Load Neutral: #4 AWG (.0mm ) to #0 AWG (4.0mm ) Typical Dimming Leg Bypass Jumpers - Do Not emove DL SL L N N DL SL L N N Dimmed Hot/Live Load Tips Wire the GP4 similar to wiring a lighting Distribution Panel: un feed and load wiring. No other wiring or assembly required. Common Neutrals are not permitted. un separate Neutrals for each load circuit. The GP4 can provide temporary lighting: Wire all loads. Do not remove the bypass jumpers that protect the Dimming Modules. Load Neutral Terminal Block Power Feed (Hot/Live) Ground Neutral Feed

GAFIK Systems gp-3 03.0.04 GP8-4 Standard-Size Panel Overview 30 Volt (CE) Wire Sizes Power Feed: #4 AWG (.0mm ) to #4 AWG (5.0mm ) Neutral Feed: #4 AWG (.0mm ) to #4 AWG (5.0mm ) Dimmed Hot/Live: #4 AWG (.0mm ) to #6 AWG (0.0mm ) Load Neutral: #4 AWG (.0mm ) to #0 AWG (4.0mm ) Typical Load Circuit Dimmed Live Load Neutral Load Feed Power Feed (Hot/Live) Neutral Feed DL SL L N DL SL L N Bypass Jumpers - Do Not emove Terminal Block Tips Wire the GP8-4 similar to wiring a lighting Distribution Panel: un feed and load wiring. No other wiring or assembly required. Common Neutrals are not permitted. un separate Neutrals for each load circuit. The GP8-4 can provide temporary lighting: Wire all loads. Do not remove the bypass jumpers that protect the Dimming Modules. Use Branch Circuit Breakers to switch lights on and off. Branch Circuit Breakers Class (PELV)

GAFIK Systems 30V (CE) Load Circuits (GP3-4) gp-36 03.0.04 All Load Types except Fluorescent Dimming Ballasts GP Dimming Panel Dimmed Live Neutral DL SL L N Load Use the Dimmed Live (DL) for all Non-Dim Load Types. All Load Circuit #4 AWG (.0mm ) to #0 AWG (4.0mm ) Load Terminals Bypass Jumpers - Do Not emove Consult Overview page for appropriate Neutral location.

GAFIK Systems GP w/ GX-TVM Overview for 0-0V, DSI, and DALI Load Types - 30 Volt (CE) Panels gp-38 03.0.04 DL = Dimmed Live L = Live N = Neutral DL L N DL L N L N Load + + +

GAFIK Systems gp-40 03.0.04 Low-Voltage Class (PELV) (All Models) System communications use low-voltage Class wiring. must be daisy-chained. must run separately from line (mains) voltage. GAFIK Eye 4000 System Class (PELV) wiring link requires: Two # AWG (.5mm ) conductors for control power. One twisted, shielded pair of #8 AWG (.0mm ) for data link. One #8 AWG (.0mm ) conductor for Emergency (Essential) sense line, from panel to panel. Total length of Control Link may be no more than,000 ft. (60m). Approved low-voltage cable is available from Lutron, Belden, and Liberty. These are approved with # AWG data link wires. Dimming Panel Control Interface Control Unit Wallstations GAFIK 5000TM/6000 /7000 System Class (PELV) wiring link requires: Two # AWG (.5mm ) conductors for control power. One twisted, shielded pair of #8 AWG (.0mm ) for data link. One #8 AWG (.0mm ) conductor for emergency (essential) sense line, from panel to panel. Total length of Control Link may be no more than,000 ft. (600m). If -PT interface and GX-CBL-46L cable is used, length may be up to 4,000 ft. (00m). Dimming Panel Processor Panel Control Interface Control Unit Wallstations Power Panel Link efer to GAFIK 5000/6000/7000 Specification GX-CBL-46L Class (PELV) wiring cable is available from Lutron and contains: Two # AWG (.5mm) conductors for control power. One twisted, shielded pair of # AWG (0.65mm) for data link. One #8 AWG (.0mm) conductor for emergency (essential) sense line.

GAFIK Systems gp-4 03.0.04 Class (PELV) Panel-to-Panel (All Models) To additional Power Panels 3,4 5 Control () # AWG (.5 mm ) : Common : 4VFW Data Link () shielded, twisted pair #8 AWG(.0 mm ) 3: 4: () #8 AWG (.0 mm ) 5: Sense Line Shield/Drain 3,4 To Lighting Controls or Processors 3 4 D 5 3 4 D 5 Common +4VFW Drain Sense Data A OK Power Data B OK Link A Link B Common 3 4 D 5 C D SELECT CICUIT Drain Common +4VFW Drain Sense Data A OK Power Data B OK Link A Link B Common 3 4 D 5 C D SELECT CICUIT Drain Circuit Circuit Dimming Panel Dimming Panel Notes: Emergency Power: The additional #8 AWG (.0mm ) wire is a sense line from terminal 5 of another Panel. This sense line allows an Emergency (Essential) Lighting Panel to sense when Normal (Non-Essential) power is lost. If more than one Emergency Lighting Panel needs to sense from a specific Normal Panel, a dedicated wire between each pair of Normal (Non- Essential) and Emergency (Essential) panels may be required. Shield/Drain: Connect shielding as shown. Do not connect to Ground (Earth) or circuit board of Circuit Selector. Connect the bare drain wires and cut off the outside shield. (4) # AWG (.5 mm ) 3 4 D 5 Class (PELV) Terminal Connections Each low-voltage Class (PELV) terminal can accept only two #8 AWG (.0mm ) wires. Two # AWG (.5mm ) conductors will not fit. Connect as shown using appropriate wire connectors. 4VFW A OK Drain Sense A Power 3 4 D 5 B C Drain D

GAFIK Systems gp-43 03.0.04 Option Delta Power Branch Circuit Protection Lutron Ten Volt Module (TVM) Locking Cover LinkTM Description Panel accepts Delta power feed (phase to phase). Available for 40 V only. Limited to, -pole circuits. Branch Circuit Breakers with higher AIC ratings or special breaker types such as: ELB (Earth Leakage Breaker - 30 V CE/40 V non-ce Only). CD (esidual Current Device - 30 V CE/40 V non-ce Only). Allows panel to operate fluorescent ballasts that meet IEC 99 standards for 0-0V control including: Lutron s TVE ballasts 0-0V neon PWM fluorescent Tridonic DSI (Digital Serial Interface). The TVM can sink or source 5OmA (typically 5-50 ballasts) on each circuit. Prevents accidental switching of circuit breakers. Adds an additional.5 (57.mm) to the front of panel. Available for GP8-GP4 only Allows a DMX5 theatrical console to operate the load circuits in the dimming panel. Allows a GAFIK Eye 4000 System to handle 8 zones (two links of 64 zones). Allows two GAFIK Eye 4000 Systems to share the same dimming panel. Application Areas with Delta power. Jobs with fluorescent ballasts that require 0-0V, PWM, or DSI control. Service corridors and public areas. Control of architectural lighting from a DMX5 theatrical console is required. A mix of architectural and theatrical lighting exists on the job. Multiple systems where space for panels is limited. Tridonic is a registered trademark of Zumtobel AG.