Selection Information Molded ase ircuit reakers lass 500, 600, 800 PowerPact 150 H-rame PowerPact 250 J-rame Trip Version Trip Version ircuit reaker Type H H HJ HL HR J J JJ JL JR Number of 2, 3 2, 3 2, 3a 2, 3a 3 2, 3a 2, 3a 2, 3a 2, 3a 3 urrent Range 15 150 15 150 15 150 15 150 15 150 70 250 b 70 250 b 70 250 b 70 250 b 70 250 b Interrupting Ratings UL/S/NOM Rating (k RMS) (50/60 Hz) Ratings 240 Vac 25 65 100 125 200 25 65 100 125 200 480Y/277 Vac 18 35 65 100 200 18 35 65 100 200 480 Vac 18 35 65 100 200 18 35 65 100 200 600Y/347 Vac 14 18 25 50 100 14 18 25 50 100 600 Vac 14 18 25 50 100 14 18 25 50 100 250 Vdcc 20 20 20 20 20 20 20 20 500 Vdcc 20 I Rating 240 Vac 25/25 65/65 100/100 125/125 125/125 25/25 65/65 100/100 125/125 125/125 (k RMS) Icu/lcsd 415 Vac 18/18 35/35 65/65 100/100 100/100 18/18 35/35 65/65 100/100 100/100 Special Ratings X X X X X X X X X X ed. Specs W--375/N X X X X X X X X X X HR (2P, 3P) X X X X X X X X X X onnections/terminations Unit Mount X X X X X X X X X X I-Line X X X X X X X X X X Rear onnection Xe Xe X X X X X X X X rawout Xe Xe X X X X X X X X Optional Lugs Xe Xe X X X X X X X X ccessories Modifications Shunt Trip X X X X X X X X X X Undervoltage Trip X X X X X X X X X X uxiliary Switches X X X X X X X X X X larm Switch X X X X X X X X X X Motor Operator Xe Xe X X X X X X X X Hle Operators Xe Xe X X X X X X X X Mechanical Interlocks (3P) X X X X X X X X X X Hle Padlock ttachment Xe Xe X X X X X X X X ylinder Lock (3P) Optional Protection Trip System Type Thermal-magnetic X X X X X X X X X Instantaneous-only (MP) Xf Xf Xf Xf Xf X X Molded ase Switch (utomatic) X X X X X X X X X X Xf Xf Xf Xf Xf Xf Xf Xf Xf Xf nclosures (Pages -56-58) eneral Purpose (NM 1) X X X X X X X Raintight (NM 3R) X X X X X X X ust-tight (NM 12) X X X X X X X Watertight (NM 4, 4X, 5) X X X X X X X xplosion Proof (NM 7, 9) imensions (3P Unit Mount) in. (mm) Height 6.4 (163) 7.5 (191) Width 4.1 (104) 4.1 (104) epth 3.4 (86) 3.4 (86) Pages (Unit Mount)/(I-Line) Pages -22, -23, -29, -34/Section 5 Pages -22, -23, -29, -34, -35/Section 5 Note: ll circuit breakers on this chart are UL Listed S ertified unless otherwise noted. a 2P in a 3P module. b 70 250 with electronic trip system c Not available with electronic trip units d ual S/UL I ratings markings on circuit breakers. e Not available in H H 2P rating (2P module). f 3P only. -4
lass 611 PowerPact Molded ase ircuit reakers PowerPact amily The PowerPact dvantage Proven Performance: Industry-leading circuit breaker innovation protection for heavy-duty commercial industrial applications. Smart: Integrated metering options provide a cost-effective solution to reduce energy consumption, optimize energy costs, improve energy availablility for your facilities. lexible: ull range of thermal-magnetic electronic trip molded case circuit breakers from 15 to 3000, delivering the ratings, configurations, operators for your unique applications. Simple: ommon catalog numbers, stardized ratings, a full range of field-installable accessories make product selection, installation maintenance easier than ever. ommon esign eatures: Mounting holes, door trim, hle accessories. H-rame 150 J-rame 250 Q-rame 250 L-rame 600 M-rame 800 P-rame 1200 R-rame 3000 Trip Version Trip Version PowerPact Interrupting Ratings Interrupting Rating Voltage J K L R 240 Vac 10 k 25 k 65 k 100 k 65 k 125 k 200 k 480 Vac 18 k 35 k 65 k 65 k a 100 k 200 k 600 Vac 14 k 18 k 25 k 65 k a 50 kb 100 k a P-frame K interrupting is 50 k at 480 600 Vac. b P-frame L interrupting is 25 k at 600 Vac. ommon atalog Numbering System rame Rating Termination Voltage mperage c H L 3 6 1 5 0 S ode ode 110 Vac Shunt Trip 2/2 uxiliary Switch rame esignation Interrupting Rating Terminations 240 Vac 480 Vac 600Vac I-Line H 150 rame 10 k L Lugs on oth nds J 250 rame 25 k 18 k 14 k us ar (No Lugs) Q 250 rame 65 k 35 k 18 k M Lugs Line Side Only L 600 rame J 100 k 65 k 25 k P Lugs Load nd Only M 800 rame K 65 k 65 k 65 k N Plug-in P 1200 rame L 125 k 100 k 50 k rawout R 3000 rame R 200 k 200 k 100 k S Rear onnected Studs c or amperage of M-, P- or R-frame circuit breakers, add a zero to the three amperage digits; for example, 120 = 1200. escription................................................page H- J-rame ircuit reakers.............................-22 H- J-rame ircuit reakers.............................-23 Q-rame ircuit reakers...................................-24 L-rame ircuit reakers...................................-25 P-rame ircuit reakers...................................-27 R-rame ircuit reakers...................................-28 PowerPact H- J-rame Motor ircuit Protectors...-29 Motor ircuit Protectors Motor Protector ircuit reakers......-31 utomatic Switches........................................-34 500 Vdc ircuit reakers....................................-35 Mission ritical ircuit reakers..............................-37 PowerPact ircuit reaker ccessories......................-39 Motor Operators Rotary Hles.........................-40 Locks, Installation ccessories, Rear onnections...........-41 Mechanical Lugs..........................................-41 ompression Lugs Power istribution onnectors (P)......-43 Terminal Nuts, Terminal Pads, Terminal Shields ccessories...-44 Plug-In rawout Mountings..............................-45 Micrologic Trip Units.............................-46 Micrologic Trip Unit ccessories............................-48-21
Motor ircuit Protectors Motor Protector ircuit reakers PowerPact H- J-rame lass 611 / Refer to atalog 0611T1001 PowerPact H- J-frame electronic Motor ircuit Protectors (MP) are magnetic-only instantaneous-trip circuit breakers. They are designed to offer short circuit protection are anadian lectrical ode () National lectrical ode (N) compliant when installed as part of a combination controller having motor overload protection. MP circuit breakers accept the same accessories terminals as the equivalent thermal-magnetic circuit breakers. etermine the hp rating from the nameplate of the motor. Select a MP with an ampere rating recommended for the hp voltage involved. When using the automatic settings the MP microprocessor automatically adjusts the trip settings for both current time to align with the start-up characteristic for the motor type, whether it is a stard or energyefficient motor. This includes a dampening means to accommodate a transient motor inrush current without nuisance tripping of the circuit breaker. H- J-frame Motor ircuit Protectors (MP) rame urrent ull Load mperes Range djustable Instantaneous Trip Range J Interrupting (See SR Table elow) L Interrupting (See SR Table elow) at. No. Price at. No. Price 30 1.5 25 9 325 M71 HJL36030M71 HLL36030M71 H-frame 50 14 42 84 546 M72 HJL36050M72 HLL36050M72 100 30 80 180 1040 M73 HJL36100M73 HLL36100M73 150 58 130 348 1690 M74 HJL36150M74 HLL36150M74 J-frame 250 114 217 684 2500 M75 JJL36250M75 JLL36250M75 Maximum Rating or Setting of Motor Protective evices Type of Motor Percentage of ull-load urrent Setting Not to xceed Motor Type / Tipo de Motor / Type de Moteur t I,,, 800% 1300%, 1100% 1700% ased on 2005 N Table 430.52. See N xception No. 1 to Table 430.52. The N 1300% maximum setting may be inadequate for instantaneous trip circuit breakers to withst current surges typical of the magnetization current of autotransformer type reduced voltage starters, or open transition wye-delta starters during transfer from start to run, constant hp multi-speed motors, motors labeled high efficiency. MP Selection by HP Ratings of Induction-type Squirrel-age Wound-rotor Motors 3Ø 60 Hz Voltages 200 Vac 230 Vac 460 Vac 575 Vac ull-load mperes.5 5.5 7.5.75 15 1 20 1.5 25 M71 5 10 5 15 10 30 15 40 14 42 M72 10 25 15 30 25 60 30 75 30 80 M73 20 40 25 50 50 100 60 125 58 130 M74 40 60 50 75 100 150 125 200 114 217 M75 ased on 2005 N Table 430.250. Per N 430.3, part-winding motors should select two circuit breakers, each at not more than one-half the allowable trip setting for the horsepower rating. The two circuit breakers should operate simultaneously as a disconnecting means per N 430.103. Listed voltages are rated motor voltages. orresponding system voltages are 200 Vac, 220 240 Vac, 440 480 Vac 550 600 Vac. Select wire circuit breakers based on horsepower rather than nameplate full-load current per N 430.6 () for general motor applications. Short ircuit urrent Rating (SR) Tested to meet N UL508 requirements for short circuit current ratings as part of an approved combination controller. Short ircuit urrent Ratings (SR) J Interrupting L Interrupting ontactor/starter 200 240 Vac 480 Vac 600 Vac 200 240 Vac 480 Vac 600 Vac Tesys -line -line 100 k 65 k 25 k 125 k 100 k 50 k NM Type S 100 k 65 k 25 k 125 k 100 k 50 k ccessories......................................... Page -39 Optional Lugs....................................... Page -42 imensions......................................... Page -55 nclosures.......................................... Page -56-29
Motor ircuit Protectors Motor Protector ircuit reakers H-rame J-rame MP Selector lass 611 / Refer to atalog 0611T1001 pplication of PowerPact H-frame J-frame Motor ircuit Protectors (MP) Horsepower Rating of Induction-type Squirrel-cage Wound-rotor Motors 3Ø 60 Hz N ull Load Starter Size 200 Vac 230 Vac 480 Vac 575 Vac mperes 1/2 0.9 1/2 1.1 3/4 1.3 3/4 1 1.7 1 2.1 1/2 2.2 1-1/2 2.4 1/2 2.5 2 2.7 1-1/2 3 00 3/4 3.2 2 3.4 3/4 3.7 3 3.9 1 4.2 1 4.8 3 4.8 1-1/2 6 5 6.1 2 6.8 1-1/2 6.9 5 7.6 2 7.8 0 7-1/2 9 3 9.6 3 7-1/2 10 11 10 14 5 15.2 15 17 1 5 17.5 15 21 7-1/2 20 22 7-1/2 25.3 20 25 27 2 10 28 30 32 10 32.2 25 34 30 40 40 41 15 42 15 48.3 3 40 50 52 20 54 20 60 62 50 65 25 68 60 75 77 25 78.2 30 80 30 92 4 75 96 100 99 40 104 40 120 100 124 125 125 50 130 150 144 50 150 5 60 154 125 156 60 177.1 150 180 75 200 192 75 221 200 240 100 248 Shaded area is not covered by J-frame electronic motor circuit protector. PowerPact H-frame J-frame MP HJL36030M71 HLL36030M71 1/2 10 hp HJL36100M73 HLL36100M73 15 50 hp JJL36250M75 JLL36250M75 50 150 hp HJL36050M72 HLL36050M72 10 25 hp HJL36150M74 HLL36150M74 30 100 hp -30
imensions Shipping Weights Molded ase ircuit reakers igure 25 igure 26 H, H, HJ, HL, HR, J, J, JJ, JL, JR, L, LJ, LL, LR ircuit reakers ircuit reaker at. No. H, H, HJ*, HL*, HR J*, J*, JJ*, JL*, JR No. of imensions ig. No. Inches 2 25 6.40 2.74 2.87 4.36 0.74 4.92 3 26 6.40 4.12 2.87 4.36 0.74 4.92 1.38 3 27 7.52 4.12 2.87 5.00 1.30 4.92 1.38 L, LJ, LL, LR 3 28 13.38 5.51 3.75 6.61 2.22 8.93 1.77 igure 27 * - The HJ, HL the J-rame 2P breakers are 3P modules, J ircuit reakers igure 28 ircuit reaker atalogue No. No. of ig. No. imensions Inches 1 29 0.98 5.66 3.09 4.05 3.32,, J 2 30 1.96 5.66 3.09 4.05 3.32 3 30 2.94 5.66 3.09 4.05 3.32 J 3 32 3.54 4.72 2.76 3.94 2.20 M, MJ, P, PJ, PL, R, RJ RL ircuit reakers ircuit reaker at. No. No. of ig. imensions Inches No. M, MJ (800 below) 2, 3 33 12.86 8.27 5.77 8.05 2.49 7.87 7.83 P, PJ, PK, PL (1000 1200 ) 2, 3 33 16.16 8.27 5.77 8.05 4.19 7.87 7.83 R, RJ, RL 2, 3 34 16.24 16.54 6.63 14.49 8.73 14.25 15.35 igure 29 igure 30 igure 31 Shipping Weightsa rame Size pprox. Shipping Weight (Lbs.) rame Size pprox. Shipping Weight (Lbs.) H, H, HJ, HL 2P 4 J, J, JJ, JL, JR 5 H, H, HJ, HL, HR 3P 5 L, L, LJ, LL, LR 14 29,, J 1P 2 M, MJ,, J 2P 3 P, PJ, PK, PL 32,, J 3P 4 R, RJ, RK, RL (Without RLT) 52 a ll weights are for 3P circuit breakers unless otherwise noted. igure 32 igure 33 igure 34-55