CHECKMATE INLINE CHECK VALVES

Similar documents
SERIES RSR PRESSURE RELIEF VALVE

C h e c k M a t e I n l i n e C h e c k V a l v e

SLURRY KNIFE GATE VALVE

SERIES 5200E Installation, Operation and Maintenance Manual

DeZURIK 2-24 (50-600mm) KGN-RSB BI-DIRECTIONAL CAST STAINLESS STEEL KNIFE GATE VALVES

APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES

Nor East. Instructions. Safety Messages. Inspection. Parts Nor East Controls. Service. Type 05 Air-O-Motor Actuator Used With Globe Valves

CPF INSTALLATION, OPERATION, AND MAINTENANCE MANUAL FLANGED SERIES CHECK VALVE *

Nor East. Instructions Safety Messages. Inspection. Parts. DeZURIK Service. Type 05 Pneumatic Actuator Used With Globe Valves

DeZURIK 2-24 (50-600mm) KGC ES or HD KNIFE GATE VALVES

DeZURIK 24" THRU 36" RESILIENT BUTTERFLY VALVES

DeZURIK KUL KNIFE GATE VALVES

SERIES 5200 AND 5200D

DeZURIK 24 and Larger BHP High Performance Butterfly Valves WITH (FB) FYRE-BLOCK SEAT

APCO CVS-6000 CONVERTIBLE SWING CHECK VALVES

DeZURIK KGC-MD KNIFE GATE VALVES

DeZURIK PEC ECCENTRIC VALVES

APCO CSV-1600 SURGE CHECK VALVE

DeZURIK KSV CL150 & CL300 BONNETLESS KNIFE GATE VALVES

DeZURIK 2 20" BOS BUTTERFLY VALVES

APCO ASR-400/450 SEWAGE AIR RELEASE VALVES

DeZURIK AFR3 Filter Regulator Used on Pneumatic Cylinder Actuators

Recommended spare parts are listed on the assembly drawing. These parts should be stocked to minimize downtime.

DeZURIK VPB V-PORT BALL VALVES

DeZURIK 2-16" PTW & PFW TAPERED PLUG VALVES

APCO SRG-6500 SURGE RELIEF GLOBE VALVES

APCO CVS-250/250A SWING CHECK VALVES

Nor East /9500 Series Double Seated Cage Valves. Instructions. Safety Messages. Inspection. Parts. Nor East Controls Service

SERIES 5400 CONTROL VALVE

CSA products for treated water. Water Combination air valve. Mod. FOX 3F RFP and Lynx 3F RFP

G500REC Manual Covering System for Containers

Model P-40 & Model P-25 POWER PUSHER

V400D VERIS Verabar (Double Rod) Installation and Maintenance Manual

Innerlynx Type UL Fire Rated 3Hour Fire Stop ADVANCE PRODUCTS & SYSTEMS, INC. ISO-9001 CERTIFIED COMPANY - FM

CW Optimizer Capacity Hat Kit. 75/80 and 80/40 Thunderbolt Vertical Antennas. for the DXE-7580-THK

APCO ACS-1200/1700 COMBINATION SLOW CLOSING AIR/VACUUM VALVE

Installation Guide Document N Cleanroom Mirrors Copyright 2016 Terra Universal Inc. All rights reserved. Revised November 2016

ActuLink ABS Module - ABS-MOD-400

CRD600 Automatic Fitting Inserter

DeZURIK " PEC ECCENTRIC VALVES

PREMIER, MARINE, & STANDARD

HAYWARD FLOW CONTROL TBH SERIES TRUE UNION BALL VALVE INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

V200D VERIS Verabar (Double Rod) Installation and Maintenance Manual

The information in this instruction manual is subject to modifications without prior notice and is the exclusive property of Zorzini.

GA Industries, LLC 9025 Marshall Road Cranberry Township, PA USA Telephone (724) Fax (724)

INSTALLATION INSTRUCTIONS

8" - 12" Hydraulic Steel Squeeze Off Tool

CRD610 Automatic Fitting Inserter

TITAN FLOW CONTROL, INC.

Heavy Duty Four Wheeled Walker

TONS. Before each shift: Before operating: Before initial operation of hoist:

PIPE REPAIR PRODUCTS REPAIR CLAMPS

V150 VERIS Verabar Installation and Maintenance Manual

CSA products for waste water. Combination air valve. Mod. SCF 2

TITAN 13 x 2½ BRAKES DUO-SERVO AND FREE BACKING

Operating and Maintenance Instructions

Guardian Steel Gear Shaft Coupling

Rex Mounted Roller Bearings

Installation Instructions

TITAN FLOW CONTROL, INC.

Effective June 1, 2013 This guide supersedes all previous versions

GC-1. Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY

STANDARD & MEGA RIM CLAMP Operations and Maintenance Manual

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

V500 and V510 VERIS Verabar Installation and Maintenance Manual

OPERATING INSTRUCTIONS ZDX 7-1/2AS

A S S E M B L Y I N S T R U C T I O N S

Guardian Taper Grid Shaft Coupling

REDI-LINE. Rugged, Reliable, DC to AC Power Conversion ELECTRIC GENERATORS USER'S GUIDE. KARAM A.L.

TBM Series 3-Way Ball Valve

OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS

DeZURIK BHP HIGH PERFORMANCE BUTTERFLY VALVE

Installation, Operation and Maintenance of the Airflex Model BT Rotorseal Assembly

IMPORTANT SAFETY INSTRUCTIONS

Complete Pond Kit REMINDER CALL BEFORE RETURNING TO STORE. PLEASE CALL BEFORE RETURNING TO THE STORE.

Level Alert Model Multi-Switch Liquid Level Sensor. Assembly and Installation Instructions

FLUID DAMPER. Vehicle Applications:

3M Electrical Markets Division. Rubber, Mastic and Specialty Tapes Application Guide. Choose the. Right Tape. for your. Electrical Project

Operating and Installation Instructions

EZ-R7 T-Plug. Universal 7-Pin Heavy Duty Plug For Vehicles equipped with 7-Way Trailer Connectors. Installation Instructions and Product Warranty

MAGNAGLIDE AIR OPERATOR VERTICAL MOUNT

Pneumatic Cylinder 14 Bore X 22 Stroke Part No. R (Formerly P )

TERMS OF USE TERMS AND CONDITIONS. Plumbing and Heating Products (PL-WR)

Installation and Maintenance Manual

USER S MANUAL FOR F & Q. Submersible Sewage Pumps

AEROMOTIVE Part # /2 4.6L SOHC Ford Fuel Rail Kit INSTALLATION INSTRUCTIONS

Installation & Operating Instructions for Zone Valve Boxes & Ball Valves

CSA products for waste water. Anti water hammer combination air valve. Mod. SCF-RFP

HATCHGRIP Installation Instructions/Operation and Maintenance Manual

RollSeal 1733 County Road 68 Bremen, Alabama Part No Rev Owner s Manual RS-Divider Curtain

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

INSTALLATION AND OPERATION MANUAL

GEN-3 Super-duty Supercharger Shaft Kit PART# - RY17040-UK-6S5-3

XM8100F/CP. Satellite Radio Antenna. antenna specialists. Patents Pending

UniTorq UTQ Quarter-Turn Actuator Installation and Operation Manual

SERIES. Table 1: Available Materials Temperatures

Customer Support

Pneumatic Cylinder 14 Bore X 21 Stroke Part No. P Replaces Part No. P

Mechanical Filter Box Kit

30 Meter Add-On Kit for the DXE-8040VA-1 Vertical Antenna

Transcription:

Tid Technologies Division of Red Valve, Inc. CHECKMATE INLINE CHECK VALVES Althon INSTALLATION, OPERATION, AND MAINTENANCE MANUAL The revolutionary design of the CheckMate lnline Check Valve provides superior backflow prevention and odor mitigation. In outfalls, stormwater, CSO and SSO applications, the CheckMate's custom-engineered, all-rubber unibody design eliminates costly backflow from oceans, rivers and interceptors. The valve's unique elastomer fabric-reinforced design provides a proven record of maintenance-free performance, cost savings and results that no other inline check valve can match. The CheckMate is built to suit all your site-specific and flow needs. The CheckMate has a 100% fabric and elastomer construction that eliminates corrosion problems. Because the CheckMate is made with a unibody construction, there are no mechanical components to catch debris, corrode or fail. The CheckMate Valve's inherit flexibility virtually eliminates seating problems. The CheckMate remains in the closed position until flow in the forward direction opens it. The fabric-reinforced elastomer CheckMate Valve seals tighly aroun dsilt and small debris, preventing unwanted backflow. The major advantage of the CheckMate Valve is its extremely low headloss. The CheckMate can open to a near full pipe diameter. This maximizes flow capacity of the outfall, which is particularly beneficial in low-lying areas where limited driving head is available. IMPORTANT Please take a moment to review this manual. Before performing any maintenance on the pressure sensors be sure the pipeline has been depressurized. The improper installation or use of this product may result in personal injury, product failure, or reduced product life. Tideflex Technologies can accept NO liability resulting from the improper use or installation of this product. If you have any questions or problems, please call the customer service department at (412) 279-0044. We appreciate your comments. Thank you for choosing Tideflex Technologies.

1. Inspection of Valve Check inside diameter of pipe section for rough or damaged areas. Surface should be uniform and relatively smooth. Long gouges or cracks may allow water to pass and should be filled prior to installation. The exterior of the CheckMate should have a rough texture resembling a cloth pattern. This will help the valve grip the walls of the pipe. 2. Valve Orientation The sealing area of the CheckMate must be installed horizontally. Valves 4" - 18" (nominal) are supplied with a single clamp. The clamp turnbuckle should be oriented at top dead center. Valves 20" - 60" (nominal) are supplied with two clamps. The turnbuckles should be oriented 180 apart. 3. Pipe Dimensions Every CheckMate Valve is designed and built to fit into a specific pipe inside diameter. Different pipe materials such as concrete, HDPE, steel, and PVC have different. I.D. dimensions for the same nominal pipe size. Do not attempt to install a CheckMate into a pipeline for which it was not intended. 4. Preparation The CheckMate uses expanding clamp(s) to exert pressure outwards on the walls of the valve to "wedge" it in place within the pipe. The walls of the pipe should be clean and free of debris prior to installation. 5. Securing The valve should be inserted fully into the pipe so that no part of the cuff or bill extends outside the pipe. Ensure that the valve is not "slanted" at an angle, with the sealing area pointing upwards or downwards. The valve centerline should be parallel to the pipe centerline. Tideflex Technologies recommends pinning the CheckMate on all installations. See below. Pre-drilled holes are provided in each expansion clamp. At least one clamp should be pinned. On exposed pipe, holes can be drilled through the valve and pipe, and a bolt run through secured with a nut. For buried pipe, silicon or similar sealant should be used to seal bolts. 6. The outside of the CheckMate Valve is marked with the word "top." The "top" marking is to be positioned in the 12:00 position. 7. The CheckMate Valve is provided with a flow direction marking. The valve must be installed in the correct direction to allow the valve to operate properly. Valves installed backwards will not function, may invert and void the warranty, even if the valve position is later reversed. www.measurit.com Install the valve at an angle Use Sharp Tools on Rubber Exceed Design Back Pressure Install the Valve Backwards

A. It is important that the CheckMate is installed level within the pipe. The CheckMate may "gap open" it installed improperly. B. The sealing area of the CheckMate must have room to expand outwards, while bottom of the sealing area rises. The area around the sealing area must be kept free of debris to allow the bill to close in order for the valve to seal properly. C. The CheckMate effectively reduces the inside diameter of the pipe in which it is installed, creating a restriction. It may also create a "ledge" inside the pipe, causing standing water. D. Back pressure in excess of the maximum line pressure may invert the sleeve and cause valve failure. E. Should the conditions that the CheckMate was designed for change, (line pressure, back pressure, chemical compatibility) the performance of the valve may suffer. F. CheckMate Valves must be installed in true round pipe which is concentric across the entire length. Out of round pipe will cause the sealing area of the valve to distort and gap, which will cause the valve to leak. www.measurit.com

Tideflex} Technologies Althon CheckMate TM lnline Check Valve Install With Tape Technical Data To install a CheckMate rn In line Check VrJve into a pipe in which the valve O.D. is smaller than the pipe I. D., follow the instructions below. 1/8" thick vulcanized rubber tape is used to build up the 0.D. of a CheckMate T M Inline Check Valve until it fits into the I.D. or the pipe. Please note, the 1/8" thick rubber vulcanized tape can only be used on CheckMaten1 Inline Check V,Jves size 3"-18". The example pictured below builds up the O.D. of a 9..5" CheckMate ni lnline Check Valve to Ht into a pipe with a 10" I.D. 'While valves 20" and larger are custom built, 4"-18" CheckMate TM InLine Check Valves are built to standard specihcations and dimensions as charted below. In sizes 4"-18": The cuff encl is interchangeable, allowing the valve to be inserted into the pipeline from either encl. All CheckMate rn Valves have a standard back pressure rating. All CheckMate n1 Check Valves are built to a common O.D. - - - CHECKMATE INLINE CHECK VALVE - - - --- VALVE SIZE LENGTH CUFF DEPTH CUFF/CLAMP BACK PRESSURE RATING STANDARD VALVE O.D. inches inches millimeters 4 9.3 236 6 13.5 343 8 16.7 424 10 19.8 503 12 23 I, 584 14 I! 30.2 767 16 33.3 846 18 36.5 927 inches MINIMUM feet 1.5 1 40 4 1 20 4 1 20 4 1 20 meters inches 12 3.75 12 5.5 12 7.88 12 9.5 12 11.88 6 13.5 6 15.5 6 17.5 Step 1: Clean the outside surface on the clamped end of the Check Mate rn Valve. Hemove all surface clirt so the 1/8" vulcanized rubber tape will stick to the valve. Step 2: Place the CheckMate TM Valve on a solid surface with the clamped end hanging sligl1tly over the edge of the surface. Step 3: Unroll a small amount or the 1/8" thick vulcanized rubber tape. Hemove plastic from both sides of the unrolled tape. Leave length of tape attached to roll.

Step 4: Place the rubber tape, adhesive side down, against the outer edge of the damped encl of the CheckMate rn Valve. Make sure the edge of the tape is flush with the edge of the valve. Press flrmly into place. Step 5: Slowly rotate the CheckMate 1 M Valve, as you continue to press the rubber tape into place around the circumference of the valve. As you apply more of the tape, press it firmly into place and line the edge of the tape up with the edge of the valve. Step 6: Unroll more of the tape. Remove plast i c: from tape. Continue to apply tape to the outside circumference of the v;jve to build up the O.D. to the desired size. In this example, 3-4 layers of continuously wrapped tape was used. The number or layers required is a [unction of the pipe I.D. dimension. Step 7: When the O.D. reaches the desired size, cut the rubber tape f r om the roll using sharp scissors. Press the end of the tape firmly into place on the CheckMate n1 Valve. Step 8: The CheckMate 1 1 Valve is now ready to be installed into a pipe. Gently slide the valve into the end of the pipe with the clamped end facing out. Make sure the,u-ea marked top on the valve is at the 12:00 position. The edge of the CheckMate rn Valve should rest flush with the edge of the pipe opening. Step 9: Once the Check Mate rm \l,jve has been eased into position, check tl1e O.D. of tl1e valve, making sure it fits snugly into the I.D. of the pipe. If the fit is loose, slide the CheckMate TM Valve out of the pipe and apply another layer of rubber tape to obtain tl1e appropriate O.D. Step 10: If you have removed the Checkivlate rn Valve to apply another layer of rubber tape, gently place the CheckMate TM Valve back into the pipe. There should be no rolling or moving of the rubber tape as you slide the valve into place. The valve should fit snugly into the pipe with the area of the valve marked top at the 12:00 position. Step 11: Once in place, tighten the ring clamp inside of the CheckMate TM Valve to secure it against the pipe. Using a wrench, tighten the bolts on the clamp until the valve is locked into place. The tightening of the clamp will compress the tape, making it waterproof. ' v Vhen properly clone, water will not bypass the seal. 1f the v,jve to pipe area leaks, remove the valve and repeat steps 9-10. Step 12: Once the bolts are tightened and the rubber tape is compressed, the CheckMate TM Valve is installed and ready for operation.

1. Inspection Valves should occasionally be inspected for damage, wear, and buildup of debris. The frequency of the inspections should be determined by the severity of the service and the environment in which it operates. The clamp should be checked for proper tension, and be sure that the inside of the valve is free of debris. Soft marine growth is normal on valves in submerged applications. Because hard marine growth such as barnacles will not bond well to the CheckMate, they can be easily removed. Also insert pins to ensure they are tight. SLEEVE INVERTED Excessive back pressure, water surge, or water hammer. LEAKING AROUND PERIMETER OF VALVE Tighten Clamp Check for cracks and holes in surface of pipe BACKFLOW Debris lodged inside bill Debris built up beneath bill If your CheckMate is to be stored for a period of time prior to installation, the following storage guidelines will help to preserve the valve and assure a trouble-free installation. 1. Store in a clean, cool, dry location. Avoid exposure to light, electric motors, dirt, or chemicals. 2. Store valve vertically on floor or pallet. 3. Store valve to prevent other items from contacting check sleeve to prevent possible damage. 4. Store this manual with the valve, so that is readily available at time of installation. WARRANTIES - REMEDIES - DISCLAIMERS - LIMITATION OF LIABILITY Unless otherwise agreed to in writing signed by Tideflex Technologies, all Products supplied by Tideflex Technologies will be described in the specifications set forth on the face hereof. THE WARRANTIES SET FORTH IN THIS PROVISION ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER STATUTORY, EXPRESS OR IMPLIED (INCLUDING ALL WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE AND ALL WARRANTIES ARISING FROM COURSE OF DEALING OR USAGE OR TRADE). Tideflex Technologies Products are guaranteed for a period of one year from date of shipment, against defective workmanship and material only, when properly installed, operated and serviced in accordance with Tideflex Technologies' recommendations. Replacement for items of Tideflex Technologies manufacture will be made free of charge if proved to be defective within such year; but not claim for transportation, labor or consequential damages shall be allowed. We shall have the option of requiring the return of the defective product to our factory, with transportation charges prepaid, to establish the claim and our liability shall be limited to the repair or replacement of the defective product, F.O.B. our factory. Tideflex Technologies will not assume costs incurred to remove or install defective products nor shall we incur back charges or liquidated damages as a result of warranty work. Tideflex Technologies does not guarantee resistance to corrosion erosion, abrasion or other sources of failure, nor does Tideflex Technologies guarantee a minimum length of service, or that the product shall be fit for any particular service. Failure of purchaser to give prompt written notice of any alleged defect under this guarantee forthwith upon its discovery, or use, and possession thereof after an attempt has been made and completed to remedy defects therein, or failure to return product or part for replacement as herein provided, or failure to install and operate said products and parts according to instructions furnished by Tideflex Technologies, or failure to pay entire contract price when due, shall be a waiver by purchaser of all rights under these representations. All orders accepted shall be deemed accepted subject to this warranty which shall be exclusive of any other or previous warranty, and shall be the only effective guarantee or warranty binding on Tideflex Technologies, anything on the contrary contained in purchaser s order, or represented by any agent or employee of Tideflex Technologies in writing or otherwise, not withstanding implied warranties. TIDEFLEX TECHNOLOGIES MAKES NO WARRANTY THAT THE PRODUCTS, AUXILIARIES AND PARTS ARE MERCHANTABLE OR FIT FOR ANY PARTICULAR PURPOSE. Althon