SFS-UFS Single Foot Switches

Similar documents
Single foot switches PX and PA series

Single foot switches - PX and PA series

Single foot switches PX and PA series

LK Position Switches TECHNICAL DATASHEET.

LR-LX-LK-LW Safety Switches with separate actuator

Safety switches with separate actuator

Safety switches for hinges

Safety switches with separate actuator

Safety rope switches with reset for emergency stop

FL series position switches

Safety rope switch with reset for emergency stop

Safety switches for hinged doors

Safety switches for hinged doors

Switches with manual reset

Microswitches M series

Safety switches with solenoid and separate actuator

Safety rope switch without reset for simple stop

Microswitches MK series

Position switches FD series

Position switches FR series

Safety switches with solenoid and separate actuator

Position switches FR series

Limit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66

Position switches FC series

FOOT SWITCHES

Limit Switches - Safety Type Plastic Body IP65 and Metal Body IP66

Microswitches MK series

Limit Switches - Limit Type (PS21L) Metal Body IP66

Microswitches MK Series

Prewired position switches FF series

Limit Switch - Prewired Type Metal Body

Limit Switches - Limit Type Plastic Body IP65

Limit switches. 7 Page 71. Presentation. OsiSense XC Basic Compact design, plastic, with reset knob, types XCNR and XCNTR. b XCNR.

Limit Switches - Limit Type Plastic Body IP65

Rope safety switches with reset for emergency stop

Limit Switches - Limit Type (PS31L) Plastic Body IP65

blocks Interconnection fuses &

Limit Switches - Limit Type (PS42L) Plastic Body IP65

Pre wired limit switches

Safety Limit Switches

Prewired position switches FF series

General_technical_data Series

PRODUCT SPECIFICATION. Foot Switches. Series.

Miniaturized limit switches

Double insulated, types XCK-P and XCK-T. With head for linear movement (plunger) operators

F E - Electromagnetic Safety Switch With Separated Actuator. 1 Code Construction. Casing: P: Plastic casing

Solenoid interlocks AZM 190 range. 128 Schmersal ,3 4,5 M20 17,5 23,5

SIRCO UL98 Load break switches standards UL and CSA 100 to 1200 A

Metal limit switches are made of zinc alloy and have a degree of protection of IP67 and NEMA Type 4, 4X.

YFC. Limit switch. Ex d. 24 operating head types

FOOT SWITCHES IN THERMOPLASTIC MATERIAL AND ALUMINIUM DIE CAST PS... / PD... SERIES. Symbols P S / P. Dimensions (in mm)

K50H004UP cam changeover switch - 4-pole A - screw mounting

K30H001YP cam star-delta switch - 3-pole A - screw mounting

125 to 4000 A. Functions. Conformity to standards. Approvals and certifications (1) General characteristics. Available on request

Pendant control stations 6

Control Equipment. ATHEX bvba Tel: +32 (0) Fax: +32 (0) Alpenroosbaan 2, 2900 Schoten, België

SIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A


AF40... AF96 3-pole contactors Technical data

XACA871 pendant control station XAC-A - 8 pushbuttons

CATALOG. EasyLine XLP Fuse Switch Disconnector poles

LS Series Limit Switches. Short Form Catalogue AC1300 ABB

Safety Limit Switch

Switch Disconnectors

Comepi S.r.l. reserves the right to modify its products and to change any details in this pubblication at any time without prior notice.

Limit switches 3. Page 92. Page 92

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

EA series housings. Selection diagram. 125 General Catalogue HMI ACTUATORS ACCESSORIES COVERS. emergency button Ø 40 push-pull, windowed

Vistop TM isolating switches 63 to 160A

Limit switches. Presentation. OsiSense XC Special For hoisting and material handling applications XCR. b XCR

Limit switches. 6 Thermoplastic roller lever 1 direction of actuation SEN TRONIC AG. Presentation

SIRCOVER. Manual Transfer Switching Equipment from 125 to 3200 A. Transfer switches. Function. Advantages. The solution for.

Compact plastic limit switches with positive opening mechanism

XACA871 pendant control station XAC-A - 8 pushbuttons

Technical data. Standards: IEC/EN EN 574 EN 418. powder-coated Protection class: IP 65. Cable section: max. 1.5 mm V I the :

XCKJ390559H29EX limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx

HS1B Series Full Size Interlock Switch. GS-ET-15 BG standard in Germany. Part Number Key

SIRCO MV PV Load break switches for photovoltaic applications for use up to 1000 VDC from 63 to 80 A

SIRCO M UL 508 Non-fusible disconnect switches standards UL and CSA from 16 to 100 A

Online data sheet. i15-em0123 Lock i15 Lock SAFETY LOCKING DEVICES

Safety switches with solenoid and separate actuator

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Operation Key D4BS - K Head Mounting Direction F: Four mounting directions possible (front-side mounting at shipping)

Selection diagram. Actuators. Body. Contact blocks. Cable entry A A S1 B B 13. Thermoplastic

Compact plastic limit switches with positive opening mechanism

Non-fusable disconnect switches standards UL and CSA from 16 to 100 A

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

Recommended use With its standard enclosure, the ENM2 limit switch can be used universally in all industrial and safety applications.

Safety switches with solenoid and separate actuator

Switches in conformity with ATEX directive

OsiSense. XC Basic Limit Switches XCMN, XCKN, XCNT

HS1B R - R. Door Interlock Switches. HS1B Series. HS1B Series Full Size Interlock Switch. Part Number. HS1B features: Part Number Key.

Solenoid interlocks AZM 170 range. 98 Schmersal 22 8,2 60. ø4,2. ø Pg 11

Safety switches with solenoid and separate actuator

SG-B1 SERIES / SG-A1 SERIES

Switches in conformity with ATEX directive

HS1E Series Full Size Solenoid Locking Switches

D4BL. Protective Doors Are Locked Until Machines Completely Stop Operating. Guard Lock Safety-door Switch. Model Number Structure.

HS2B N B - R. Door Interlock Switches. HS2B Series. Full Size Interlock Switch. Part Number. HS2B features: Part Number Key.

AZM 161SK 12/12RKED/TU 024

Transcription:

SFS-UFS Single Foot Switches Technopolymer housing, shock proof Protection degree IP53 or IP65 13 contact blocks available Various auxiliary devices available UFS Series SFS Series Options & Ordering Codes Note: The feasibility of a code number does not mean the effective availability of a product SFS YE 01 1 1 A 20 X Footswitches External Metallic Parts shrouded version unshrouded version SFS UFS X zinc-plated steel (standard) stainless steel Colour of Cover yellow RAL 1023 YE red RAL 3020 RE grey RAL 7035 GY black RAL 9017 BL blue RAL 5017 BU Contact Block Combinations 1NO+1NC, snap action (AC-C501*) 2x (1NO+1NC), snap action (AC-C501+AC-C501*) 1NO+1NC, slow action (AC-C601*) 2x (1NO+1NC), slow action (AC-C601+AC-C601*) 2x 2NO, slow action (AC-C1001+AC-C1001*) 2x 2NC, slow action (AC-C901+AC-C901*) 2NC, slow action (AC-C901*) 2NO, slow action (AC-C1001*) 1NO+1NC, slow action, make before break (AC-C701*) 2NO, snap action (AC-C1201*) 2NC, snap action (AC-C1101*) 2x (1NO+1NC), snap action shifted (AC-C501+AC-C501*) (1NO+1NC)+(2NC), snap action, shifted (AC-C501+AC-C1101*) Other combinations on request * Denotes contact block type used in unit. Also available separately. 01 02 03 04 05 06 07 08 09 14 15 20 24 0 3 4 0 IP53 1 IP65 Devices without devices A B C D Protection Degree 1 with safety lever 2 lock of the pedal actuator with safety lever and with two-stage actuating force (only with contact block combinations 20 & 24) Threaded Conduit Entry PG 13.5 20 M20 x 1.5 Accessories (SFS series only) without accessories with technopolymer carrying rod (400mm) with M25 hole for AC-KIT31 with M25 hole for AC-KIT31 with stabilising plate with technopolymer carrying rod (660mm) without safety lever and with two-stage actuating force (only with contact block combinations 20 & 24) p1

Selection diagram CARRYING RODS ADDITIONAL METAL SHROUD AC-KIT71 UNSHROUDED COVERS UFS BL UFS RE CONTACT BLOCK COMBINATIONS SHROUDED COVERS 01 02 1NO+1NC, snap action 2x(NO+NC) snap action PEDAL DEVICES 0 1 2 without devices with safety lever lock of the pedal actuator CONDUIT ENTRY 3 4 two stage two-stage with safety lever Threaded conduit entry 20 M20x1.5 PG 13.5 STABILISING PLATE product options accessory sold separately p2

EMERGENCY PUSH BUTTON SFSBL SFSBU METAL PIPES SFSGY SFSRE SFSYE CARRYING HANDLE SFS-B SFS-C Specifications Housing Housing with double insulation: Base: Cap: Tightening torque, cover screws: Actuating force: One threaded conduit entry: Tightening torque, cable clamp screws: Protection degree: glass fibre reinforced technopolymer, self-extinguishing and shock-proof technopolymer, self-extinguishing and shock-proof 0.8 1.2 Nm 16 N PG13.5 0.8 1 Nm IP53 (FS 0) or IP65 (FS 1) acc. to EN 60529 with cable gland having equal or higher protection degree General data Ambient temperature: -25 C +80 C Safety parameters: B 10d : 20,000,000 for NC contacts Max. operation frequency: 3600 operating cycles 1 /hour Mechanical endurance: 10 million operating cycles 1 (1) One operation cycle means two movements, one to close and one to open contacts, as defined in EN 60947 5 1. Utilization categories Alternating current: AC15 (50/60 Hz) Ue (V) 400 500 Ie (A) 6 4 1 Direct current: DC13 Ue (V) 24 125 Ie (A) 6 1.1 0.4 Electrical data Thermal current (Ith): 10 A Rated insulation voltage (Ui): 500 Vac 600 Vdc Rated impulse withstand voltage U imp : 6 kv Conditional short circuit current: 1000 A acc. to EN 60947 5 1 Protection against short circuits: type am fuse 10 A 500 V Pollution degree: 3 Cable cross section (flexible copper strands) Contact block combinations (all): min. 1 x 0.5 mm 2 (1 x AWG 20) max. 2 x 2.5 mm 2 (2 x AWG 14) Terminal screw tightening torque: 0.6 0.8 Nm In conformity with standards: IEC 60947-5-1, EN 60947-5-1, IEC 60947-1, EN 60947-1, EN 60529. In conformity with the requirements of: Low Voltage Directive 2006/95/EC, Machinery Directive 2006/42/EC and EMC Directive 2004/108/EC. Positive contact opening in conformity with standards: IEC 60947 5 1, EN 60947 5 1. p3

Dimensional drawings Contact type: Unshrouded Shrouded Shrouded version with M25 hole for AC-KIT31 All measures in the drawings are in mm R = snap action L = slow action LO = slow action make before break RS = snap action shifted M25x1.5 230 100 96 76 67 87 Contact block combinations 01 R UFSRE0100 1NO+1NC SFSYE0110 1NO+1NC SFSYE0110-B20 1NO+1NC 79 02 R UFSRE0200 2x (1NO+1NC) SFSYE0210 2x (1NO+1NC) SFSYE0210-B20 2x (1NO+1NC) 03 L UFSRE0300 1NO+1NC SFSYE0310 1NO+1NC SFSYE0310-B20 1NO+1NC 04 L UFSRE0400 2x (1NO+1NC) SFSYE0410 2x (1NO+1NC) SFSYE0410-B20 2x (1NO+1NC) 05 L UFSRE0500 2x 2NO SFSYE0510 2x 2NO SFSYE0510-B20 2x 2NO 06 L UFSRE0600 2x 2NC SFSYE0610 2x 2NC SFSYE0610-B20 2x 2NC 07 L UFSRE0700 2NC SFSYE0710 2NC SFSYE0710-B20 2NC 08 L UFSRE0800 2NO SFSYE0810 2NO SFSYE0810-B20 2NO 09 LO UFSRE0900 1NO+1NC SFSYE0910 1NO+1NC SFSYE0910-B20 1NO+1NC 14 R UFSRE0 2NO SFSYE1410 2NO SFSYE1410-B20 2NO 15 R UFSRE1500 2NC SFSYE1510 2NC SFSYE1510-B20 2NC 20 RS UFSRE2000 1NO+1NC (2 cont.) SFSYE2010 1NO+1NC (2 cont.) SFSYE2010-B20 1NO+1NC (2 cont.) 24 RS UFSRE2400 2NC (2 cont.) SFSYE0 2NC (2 cont.) SFSYE0-B20 2NC (2 cont.) Contact block data on page 31. Legend Closed contact Open contact Positive opening travel Pushing the switch / Releasing the switch p4

Combination examples All measures in the drawings are in mm Shrouded foot switch with 400 mm technopolymer carrying rod Shrouded foot switch with 660 mm technopolymer carrying rod 99 142 99 142 96 79 530 790 96 79 SFSYE0110-20 AC-KIT21 SFSYE0110-20 is supplied pre-drilled for fixing the carrying rod kit. These articles can also be purchased together using part number SFSYE0110-A20. SFSYE0110-20 AC-KIT22 SFSYE0110-20 is supplied pre-drilled for fixing the carrying rod kit. These articles can also be purchased together using part number SFSYE0110-D20. Shrouded foot switch with M25x1.5 hole and stabilizing plate Shrouded foot switch with metal pipe, stabilizing plate and emergency button 1 NC M25x1.5.2 829.8 87.1 124.1 SFSYE0110-B20 AC-KIT60 This article can also be purchased with single code SFSYE0110 C20. SFSYE0110-B20 AC-KIT60 AC-KIT31 AC-KIT32 p5

Combination examples Unshrouded foot switch with additional metal protection. Ideal for heavy duty applications with safety shoes. Unshrouded foot switch and metal protection with 400 mm metal carrying rod For heavy-duty work environments, cap with increased dimensions for safety shoes. Ø38 145 134 120 120 145 445 134 240 240 UFSRE0100 AC-KIT71 UFSRE0100 AC-KIT71 AC-KIT25 Shrouded foot switch with metal pipe, stabilizing plate, carrying handle and emergency button 1 NC Shrouded two stage foot switch where partial force on the pedal actuates one contact block and an increased force actuates the second contact block. Includes: metal rod; stablising plate; carrying handle; emergency button 1 NC 87.1 124.1 829.8 87.1 124.1 829.8 SFSYE01102-B20 AC-KIT60 AC-KIT31 AC-KIT32 AC-KIT50 SFSYE2040-B20 AC-KIT60 AC-KIT31 AC-KIT32 AC-KIT50 p6

Safety lever The safety lever prevents the lowering of the pedal actuator in case the foot is not fully inserted into the pedal. This prevents the accidental activation of the pedal. 1 2 The foot must be completely inserted in order to lower the safety lever and push down the pedal actuator. Lock of the pedal actuator 1 2 3 Insertion of the foot in the pedal Pushing down the pedal actuator, the contact switches and the device locks the actuator Releasing the pedal actuator, the lock device keeps it down. 4 5 To unlock the pedal actuator, push the locking device Upon drawing the foot from the foot switch, the pedal actuator and the contacts return to their initial positions 2-stage actuating force 1 2 3 SFS foot switches with two overlapped snap action contact blocks (2x 1NO+1NC), two steps actuation force and safety lever. Pressure point With a light pressure (~19 N) on the pedal actuator, the first contact block switches while the second keeps its state. The pedal actuator stops at pressure point. Pushing down with higher force (~180 N) on the pedal actuator, the second contact block switches as well. In this position both contact blocks have been switched. p7 Errors and omissions excepted. Subject to change without notice.