mana Technical Information Manual Clean Gas Range RG3600 P1143336N, P1143362N, P1143372N Due to possibility of personal injury or property damage, always contact an authorized technician for servicing or repair of this unit. This technical sheet replaces RT2310008 Rev. 1. Refer to Service Manual RS2310004 for detailed installation, operating, testing, troubleshooting, and disassembly instructions. Refer to Parts Manual RP2310048 for part number information.! CUTION ll safety information must be followed as provided in Service Manual RS2310004. To avoid risk of electrical shook, personal injury, or death, disconnect power to oven before servicing, unless Models RG3600 Power Source Electrical rating 120 VC mperage 15 mp maximum Frequency 60 Hz Water Column Pressure Natural 5 in. W.C.P. LP/Propane 10 in. W.C.P. Surface urner (TU Nat./LP) Four burners 9,700/8,000 Oven urner (TU Nat./LP) ake 18,000/16,000 Oven Interior Dimensions in. (cm) Height 16 (41) Width 23 (58) Depth 17 1/2 (44) Product Exterior Dimensions in. (cm) Height overall 46-1/2 (118) Width 30 (76) Depth oven door closed with handle 28-1/4 (72) Clearance oven door 20 (51) Height of cooktop 36 (91) Weight lbs. (kg) pproximately shipping weight 164 (75) Features Interior oven light Square wire steel burner grates roiler pan and grid Two oven racks 5 positions One broiler rack 3 positions Exclusive high performance sealed gas burners Glass oven door with small window Clock timer, LED June 1999 1 RT2310008 Rev. 2
Illustration Component Test Procedure Results 316385 Oven light socket Remove one wire from receptacle and test resistance of terminals. Indicates continuity with bulb screwed in. Measure voltage at oven light. 316160 Rocker switch Measure continuity of switch positions: Closed Open 31827601 Gas valve Disconnect wiring to valve. Measure resistance on bake circuit. Measure resistance on broil circuit. NOTE: There are no field adjustments on the safety valve. 31829701 Pressure regulator Verify gas pressure (WCP). If on LP service, verify proper gas supply conversion. 31829001 Oven thermostat Verify selector cartridge is set to the proper gas (LP or Natural). Set to higher than actual temperature. 31837802 90 valve Verify gas is supplied. 120 VC, see wiring diagram for terminal identification. If no voltage is present at oven light, check wiring or light switches. Continuity, if not replace. Infinite, if not replace. llow 60 seconds for gas valve to open. Continuity, If not replace. Continuity, If not replace. Do not attempt to open valve with 120 VC. 5 Natural 10 LP/propane 14 maximum supply NOTE: There are no field adjustments. Heater pilot will envelope temperature responsive element and burner will light within 60 seconds. Clean flame at burner. Orifice adjusted for Natural or LP. 31837701 Spark 90 switch Test for voltage at terminals. Disconnect wiring and check for continuity in LITE position. 31837601 Thermostat switch / Disconnect switch leads. valve switch ttach meter leads to switch. Measure for resistance. Switch in LITE position. Switch in any position except LITE position 315768 Top surface burner Verify gas is supplied. 120 VC in LITE position Continuity in LITE position. Continuity Infinite Clean flame not blowing or soft / lazy. Verify burner cap is positioned correctly. Check for obstructions in burner ports. Check air shutter and LP conversion. RT2310008 Rev. 2 2 June 1999
Illustration Component Test Procedure Results 31829601 Spark module 4 + 1 Test for voltage at terminals L and N 120 VC with switch on. See wiring diagram GROUND MNUL REIG Oven ignitor Verify polarity and ground. COMMON NEUTRL LIVE urner ignitors 4 + 1 Spark Module 31829301 Oven burner spark ignitor Disconnect ignitor lead from spark module. ttach meter leads to tip of ignitor and spade receptacle. Measure for continuity. Continuity Infinite Ignitor good Replace Ignitor 31827801 ake burner Verify gas is supplied. Orifice adjusted for Natural or LP. Check for obstructions or contamination in ports. 31830101 Pilot assembly Verify pilot selector cartridge is set to the proper gas (LP or Natural). 31715201 LH 317068 RH Opening 31828101 RH 31828102 LH Oven door hinge roiler door hinge Set thermostat to higher than actual temperature. Carefully open the hinge fully, and insert a wooden dowel or screwdriver bit into opening. Remove top and bottom screws securing hinge. Slide hinge top towards rear of unit and guide hinge out through frame opening or storage drawer. Replace hinge if hinge does not operate properly. Constant pilot flame. Heater pilot flame envelopes temperature responsive element.! CUTION Do not place hands in hinge area when oven door is removed. Hinge can snap closed and pinch hands or fingers. 31838302 Clock timer Verify voltage is present at the input and output terminals. June 1999 3 RT2310008 Rev. 2
Converting from Natural Gas to LP Gas Converting Type 2 Pressure Regulator for Use with LP/Propane 1. Remove pressure regulator cap with a wrench. 2. Reverse pressure regulator cap. Cap must show LP. 3. Place pressure regulator cap on pressure regulator and tighten. LP D urner Control Knob Pivot Point C urner Control Panel D Screw C Cap Converting Surface urners for Use with LP\Propane 1. Remove 5 control knobs from range. Exposes 2 screws on burner control panel. 2. Remove 2 screws from burner control panel. Panel drops slightly after screws are removed. 3. Grasp bottom of burner control panel, gently lift and pull out panel until clear of burner valve stems. fter burner control panel clears valve stems, continue to roll panel until free from range. Set aside. Gas valve and orifice hood are visible after burner control panel is removed. 4. While facing range front, turn orifice hoods counterclockwise 1½ to 2 turns or until snug. Use ½ inch open end or 90 offset open end wrench. Do not over tighten orifice hoods. If orifice hoods are over tightened, gas supply can be cut off or orifice hoods can strip. 5. Open air shutter fully. Orifice Hood ir Shutter Open Fully RT2310008 Rev. 2 4 June 1999
Converting Oven urner for Use with LP\Propane 1. Open broiler door and remove broiler rack, pan, and grid. 2. Through rectangular hole on rear of broiler cavity, turn orifice hood (tighten) clockwise when facing front of range, 1½ to 2 turns or until snug. Do not overtighten orifice hoods. Orifice hoods can strip. Open Fully ir Shutter Screw Orifice Hood C ir Shutter C D urner Control Knob Pivot Point C urner Control Panel D Screw C 4. Turn the selector screw on oven thermostat so the pointer is towards LP. 5. Reverse steps 1 3 to replace control panel and knobs. 3. Open air shutter fully. Converting Oven Thermostat for Use with LP\Propane 1. Remove all (5) control knobs from range. Exposes 2 screws on burner control panel. 2. Remove 2 screws from burner control panel. Panel drops slightly after screws are removed. 3. Grasp bottom of burner control panel, gently lift and pull out panel until clear of burner valve stems. fter burner control panel clears valve stems, continue to roll panel until free from range. Set aside. Selector Screw LP N OFF LP N OFF LP N OFF June 1999 5 RT2310008 Rev. 2
Wiring Diagram and Schematic RG3600 RT2310008 Rev. 2 6 June 1999