OIL LEVEL GAUGES FOR DISTRIBUTION TRANSFORMERS

Similar documents
THERMOMETERS For distribution transformers

Liquid filled Thermometers

TERMINAL BOXES FOR OIL IMMERSED TRANSFORMERS (Series 2009)

Oil level gauges Series IL

Flow Meter Terminal Boxes

THERMOMETERS FOR TRANSFORMERS

Gas-actuated thermometer Model 73, stainless steel version

THROTTLE VALVES FOR RELAYS AND RADIATORS Series 2009

THERMOMETERS FOR POWER TRANSFORMERS Oil temperature indicators O.T.I. Winding temperature indicators (thermal image) - W.T.I.

BUSHINGS: GENERAL INFORMATION

SAMPLE PRODUCT SPECIFICATIONS

Gas-actuated thermometer with switch contacts Model 73, stainless steel version

Gas Actuated Thermometers Stainless Steel Series, Model 73

Dial thermometers. Gas filled system and Bi-metal. dial thermometers

Buchholz Relays Series RR - RRF - GQ

EJB Enclosures. ATEX II 2 G Ex d IIB+H2 T6...T3 - II 2 D Ex td A21 T85 C C IECEx Ex d IIB+H2 T6...T3 - Ex td A21 T85 C...

Gas-actuated thermometer with switch contacts Stainless steel version Model 73

Industrial-Thermometer

Remote reading dial thermometers, version for industry

TWM 7284 & TWM Microswitches equipped Thermostats type :

Design specifications

PORCELAIN BUSHINGS ED Series

Linear Valve Electric Actuator

GAS ACTUATED RELAYS FOR OIL FILLED TRANSFORMERS EN

Distribution transformers Efficiency over life-cycle

MSRT 150. Oil Temperature Indicator for Power Transformer type :

TRANSPORT. Take all the necessary precautions to prevent the load from knocking against the vehicle during transport. - 1/5 -

MESSKO MTraB product line (see application table page 3) MESSKO MTraB connection requirements

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

History of the company. TUMETIC and TUNORMA: Tailor-Made Technology

MODEL PC-252 Transformer Temperature Indicator Oil & Winding Temperature Indicator (with Micro Switches)

Key features. DESIGNS: - Conservator type - Hermetically sealed

Transformer Components & Accessories

* T Temperature-Indicating Dial (Must be field set and calibrated to an actual thermometer)

VALVE WITH SA ELECTRIC ACTUATOR

SECTION METERS AND GAGES FOR PLUMBING PIPING

BUCHHOLZ RELAYS EE Series

Buchholz Relay MBP Gas and Oil Actuated Relay

TECHNICAL CATALOGUE SELF CONTAINED HORIZONTAL AIRCONDITIONERS Rev105

RELAYS. Figure Relay construction.

Table of Contents. 1. Model Designation And Unit Models Guide Specifications Technical Data Performance Data 10

FIRE CONTROL

A6C A5C-B6C B5C B5H A6C A5C B6C B5C B5H. Model. Up to kw. Power. Up to V. Voltages. Model IP55. Frame Pole 2, 4, 6, 8 and 10

ENGLISH Datasheet Platinum Resistance Pt100 4 wire class B Resistance Thermometer with Compact KNS Head

NARVIK-YARWAY. High Pressure Level Gauges, Model: 17

Temperature Regulators

Foxboro Dew Point Measurement System Model 2761 Mechanical DEWCEL Element Model 2781 Electrical DEWCEL Element

MESSKO MTO Oil Level Indicator

Screw jacks MA Series

CAST RESIN TRANSFORMERS CRT ED.: DEC.13 REV.00

Gauges, Sight Glasses and Vacuum Breakers

1. SPECIFICATION. Altitude of motor installation. Information: Resistance and temperature specifications of the PTC thermistor / posistor/.

Temperature Switch Gauges

Product features & Overview. KA Linear actuators

Diesel engine dial thermometers

PNO Condenser Bushings from 52 kv to 420 kv Oil-to-air - Oil-Impregnated Paper

Industrial Substation Maintenance April $4,250 Abu Dhabi. UAE

ELECTRICAL ITEMS Cables : Specification: XLPE Insulated Power Cable All Cables Cables PVC Insulated Cables Fire Resistant Cables Aluminium Cables

KombiTemp. Head form B / Head form J Cable socket, angle type Diesel engine dial thermometers. Temperature Sensors with local display

TRANSFORMERS UP TO 750 kv

MTF-E. Technical features

We proudly deliver a unique and

MODEL INFORMATION CANNED MOTOR PUMP TYPE CAM HERMETIC

CAST RESIN TRANSFORMERS

VALVES WITH SA ELECTRIC ACTUATOR

XS-F VALVE WITH SA ELECTRIC ACTUATOR

Series Cylinders according to standard ISO 15552

MTF. Technical features

Pressure Controller. Cataloge K Code Characteristics Index. K00-2 Pressure Controller Brief Introduction

BUSHINGS AND ACCESSORIES FOR DISTRIBUTION AND POWER TRANSFORMERS

ELECTRIC SUBMERSIBLE PUMPS SEMISOM/80

OIL TO AIR BUSHINGS SERIES PNO. VOLTAGE FROM 52 kv TO 245 kv

W91/W94 Series TEMPERATURE REGULATORS. Self-Operated Temperature Regulators. Design & Operation W91 Non-Indicating W94 Dial Thermometer

PARAMAX Series. Agitator Drives CW11

KOBOLD VKA FLOWMETER/SWITCH. User Instructions. Manual-VKA_03-04

VALVES WITH NA ELECTRIC ACTUATOR

DG 023 DG 024 DG 025 DG 041 DG 042. Clogging Indicators

Resistance thermometer with digital indicator Model TR75, battery operation

Size and Configurations

GT All SS Industrial Dial Thermometer Gas Filled system

ÒÌÃ TRANSFORMERS. ÒÌÃ 1250 kv.a

Thermal Overcurrent Circuit Breaker 3120-F...

INDEX. The technical and dimensional data reported in this manual may be modified in view of any product improvement.

Gas-actuated thermometer Highly vibration resistant Model 75, stainless steel version

Series TNS/TNF Thermometers Installation/Operation Instructions

SAV Electronic Valve Actuator

V230T. Mould Hydraulic Systems. Hydraulic cylinders - high temperature 230 bar V230T

We uses No Cobalt (Neo-Blue) of pro-environment as dehydrator to be filled in the container of all breathers.

UNIBAD. Bath water circulating pump

WINTERS ( )

Class 1 as per EN o C to 65o C 15 kg/cm2 ( without thermowell ) 120 % of Full Scale 8 mm ½ BSP (M) Adjustable

INSTRUCTION MANUAL RELAY FOR ON LOAD TAP CHANGER APPLICATIONS OR-25 5COR OR25 REV03

Protection against mechanical impacts IK 08 according to IEC 68, EN Insulation class Class F (155 C), class H (180 C) on request.

Compact temperature switch Model TCS

Product presentation CPT tech Jason Evershed, ABB Transformer Components, May 21st Dry-type transformers Innovative Technology

Bushing Insulators according to DIN and UNEL Standards

Motors Automation Energy Transmission & Distribution Coatings. Flat-frame Motors K1F / K2F

Bimetal thermometer with Pt100 electrical output signal Model 54, stainless steel version

CX1 ProVector Explosion-Proof Heaters

How to Select the RE Industrial Actuator Part Number

Transcription:

(Model Year 2014)

OIL LEVEL GAUGES FOR DISTRIBUTION TRANSFORMERS MAGNETIC OIL LEVEL GAUGES (without contacts) Page 5.26. Type IML 80 and IML 99. They are the two cheapest gauges of our range, with aluminium body, suggested to be used in distribution transformers (max conservator diameter 400mm). An arrow gives the indication of the oil level inside the conservator; they cannot be fitted with electric switches and they can be supplied only in the "R" execution (float movement parallel to the dial). SIDE WALL OIL LEVEL GAUGES Page 5.34 (drg B 3190). Prismatic type. They give an optic indication of the oil level inside a transformer tank or inside a conservator. The steel frame must be bolted to the wall of an hermetic transformer or to the end of a conservator of a conventional transformer. File : ACCESSORI DISTRIBUZIONE.doc UNCONTROLLED COPY REV 05 dtd 22/03/11

AIR DEHYDRATING BREATHERS for distribution transformers Type TV75-6 and VE05-VE10 1. GENERAL INFORMATION Air dehydrating breathers are transparent hollow cylinder tubes which contain chemically pure silicium salt (silicagel) with coloured indicator. The air breathed inside the transformer due to the thermal contraction of the oil mass, passes through the silicagel. The silicagel absorbs the humidity, indicating the saturation degree by changing colour as follows: ORANGE silicagel completely dry. WHITE silicagel saturated with humidity. The salt contained in the breather, when saturated, may be easily removed and regenerated by heating it, inside a ventilated oven, at 120-150 C, until the colour becomes orange again. The specific property of the silicagel is its high absorption power of humidity. This is total until the salt has absorbed water for about 15% of its weight, and saturation is reached when the salt has absorbed water for 30 to 40 % of its weight. 2. TECHNICAL FEATURES The upper and lower parts are made in a non-porous corrosion-proof aluminium alloy casting. The hollow cylinder is made of plexiglass and it is protected by a stainless steel cylinder, with windows which allow the visual control of the silicagel colour. In the bottom side of the breather, an hydraulic valve prevents continuous air contact with the silicagel and allows the air to pass in both direction (inlet or outlet) only when there is pressure deficiency or excess inside the transformer. Pressure values for air passage into the dehumidifier are: 0.003 kg/cm 2 inlet, or 0.005 kg/cm 2 outlet. The hollow container and the hydraulic valve are separated by a drilled plate with a labyrinth system, which have the double purpose of diffusing inlet air uniformly, and of avoiding that any salt dust may damage the closing system. 3. AIR DEHYDRATING BREATHER TYPE TV75 & VE05 & VE10 (Drg.3535) They are small sized dehydrating breathers, particularly fit for assembling on small distribution transformers The type VE05 follows the same manufacturing principles of the bigger sizes like the type VE10. The type TV75 (or TV74) is the cheapest model of our breathers: its top flange is made in corrosion proof aluminium alloy. The silicagel housing is made of cellulose triacetate (cellidor by Bayer), suitable for mineral oil; only upon request, this breather can be fitted with a stainless steel cylindrical protection. File : ACCESSORI DISTRIBUZIONE.doc UNCONTROLLED COPY REV 05 dtd 22/03/11

THERMOMETERS For distribution transformers Page 5.15 : Thermometer MTVT 84 Oil temperature indicator, new concept, fitted with two independent microswirches, range 0...120 C, only with bottom entry rigid bulb. Page 5.16 : Thermometers type BM (drg 1292) Bimetallic oil temperature indicator, without contacts, range 0...120 C, with radial rigid stem or back entry, stainless steel housing. Page 5.17 & 5.19 : Thermometers type TESS Oil temperature indicators, standard quality, for small distribution transformers, with two low speed contacts (low rating), stainless steel housing, range 0...120 C -(page 5.17 - drg 1290) with radial rigid stem, suitable for cover mounting -(page 5.19 - drg 1365) Thermometer type TESS-B-100 with back entry stem and with two contacts (for side wall mounting on transformers without conservator with nitrogen cushion) -(page 5.19 - drg 1365) Vacuum-Pressure Gauge VPG-100 with two contacts (for side wall mounting on transformers without conservator with nitrogen cushion) Page 5.19.A & 5.20.A: Thermometers type TECED High performance oil temperature indicators, organic liquid filled, for distribution transformers of bigger size or for small power transformers, with low speed contacts (low rating), aluminium housing, range 0...120 C TECED-R with radial rigid stem (pag 5.19..A) TECED-Y with armoured flexible capillary (pag. 5.20..A) HOUSING: Light aluminium alloy casting with glass window locked by a bronze ring PROTECTION DEGREE: IP 55 OUTDOOR MOUNTING: Allowed BREATHING DEVICE AND DRAIN SCREW: Supplied upon request, are necessary for the use of our thermometer in tropical climate zones, in order to avoid moisturing inside the casing STANDARD RANGE: 0...120 C PRECISION CLASS: +/- 1,5 MAX POINTER: Supplied upon request CAPILLARY (only for form Y pag. 5.20A). Hermetically sealed capillary tube; bottom entry Armouring: Copper tube or zinckplated flexible sheath inside a plastic tube OIL IMMERSED BULB AND CONNECTOR: On pages 5.19.A and 5.20.A are shown the most commonly used styles, but it is possible to supply tailor made executions, according to customer's specifications. ELECTRIC CONTACTS: Two independent max contacts normally open (other wiring diagrams available upon request), air insulated, slow speed action (these contacts must always work through a relay, never directly on the circuit breaker) CONTACTS CHARACTERISTICS: Insulation test at 2000 V/ 50 Hz Rated voltage [V] 380 230 110 50 Rated current [ma] dc ac / R load ac / ind. load 25 43 85 130 26 45 90 170 15 22 45 70 SPECIAL CONTACTS: Contacts may be fitted with two small magnets, with the scope of avoiding sparks between them, due to the increased closing speed; consequently the current rating increases slightly, at a loss of precision of the temperature indication near to the contact set point, and the contact opening The t has a small increase. ORDERING INSTRUCTIONS: TECED type R or Y, nominal dial diameter, bulb style and connection, capillary entry - length - armouring ( only for form-y ), special requirements such as max pointer, breather, ground terminal, special wiring diagrams, special range or other. File : ACCESSORI DISTRIBUZIONE.doc UNCONTROLLED COPY REV 05 dtd 22/03/11