Installation Instructions

Similar documents
W-SERIES TYPICAL INSTALLATION INSTRUCTIONS & WARRANTY INFORMATION SIMPLEX, DUPLEX, TRIPLEX & QUADPLEX STATIONS

One City Plaza, Suite B P.O. BOX 1287 Cabot, Arkansas Phone Revised: May 06, 2016

One City Plaza, Suite B P.O. BOX 1287 Cabot, Arkansas Phone Revised: April 2, 2019

WH47 & WR47 Series Simplex & Duplex Typical Installation Instructions & Warranty Information. 476-Gal. Capacity Grinder Pump Station

Installation Manual. D3600- Series Duplex Grinder Systems. Contents

Installation Manual. Q Series Quadplex Grinder Systems. Contents

CPG 2HP Grinder Series

INSTALLATION AND SERVICE INSTRUCTIONS KER KEEN PUMP - e/one Replacement

2460 / 2472 / Series Simplex Grinder Systems

SEPTIC TANK PUMP VAULT FILTER SYSTEM PUMP VAULT INSTALLATION AND SERVICE MANUAL

PRE-PLUMBED SEWAGE SYSTEM

RETROFIT SYSTEMS INSTALLATION AND SERVICE MANUAL. Engineered for quick and easy replacement of existing progressive cavity grinder systems.

WSB clean: Installation Manual

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13

PUMP VAULT S.T.E.P. SYSTEM

Access Riser Fits PRO370 and PRO380 Series

Installation, Operation and Maintenance Manual Stancor SSD & SL Series Pumps

Aqua Green Utility Inc.

BioSTEP Screened Pumping System Installation & Service Manual

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

INSTRUCTION MANUAL IM245. RGS2012E1 S or E Retrofit Kit SUBMERSIBLE GRINDER PUMP INSTALLATION, OPERATION AND TROUBLESHOOTING MANUAL

Submersible Effluent Pump

KG(X)3. Grinder Pumps. 3HP High Flow Grinder Pump (Class 1, Div. 1, Groups C & D Hazardous Location) Performance Curve. Total Head (FT) Capacity (GPM)

V4PS. Installation, Operation, & Maintenance Manual

Operation and Maintenance

SHALLOW WELL JET PUMP

B-2000 INSTALLATION GUIDE AND MAINTENANCE INSTRUCTIONS

STAR STOP SHALLOW WELL JET PUMP

Condensate Pump. Installation and Safety Instructions CP-22 CP CP-22LP CP-22LP-230

2010iP Simplex Typical Installation Instructions Simplex Station 700 L Capacity

PRE-INSTALLATION GUIDE

ON-SITE WASTEWATER PRODUCTS

Installation, Operation and Maintenance Manual Stancor SE, SV, SS & SC Series Pumps

ME3H/ME3F SERIES. Automatic and manual models. Single phase power only 115 or 230 volt.

INSTALLATION, OPERATION, SERVICE & REPAIR PARTS MANUAL FOR

Installation & Operating Manual

Hampton Roads Planning District Commission

barmesapumps.com BGP-DS RPM Installation, Operation & Maintenance Manual Submersible Grinder Pumps

Condensate Pump. Installation and Safety Instructions CP-22 CP CP-22LP CP-22LP-230

Voltmaster Centrifugal Trash Pumps

1BGrease Traps and. Frequently Asked Questions About Grease:

SPC-PANEL Simplex, Single Phase Pump Control Panel

SUBMERSIBLE SUMP PUMPS

QWIK JON ULTIMA 204 SYSTEMS INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

LAWN SPRINKLER, IRRIGATION PUMP

Installation Manual. Engineered Pump Systems (EPS) Common Components: Manual Contents:

Simplex For Series: SGV 5HP / 1PH Pumps

2 Wire Plus Ground 3 Wire Plus Ground IL0655

PUMP SPY INSTALLATION AND OPERATING INSTRUCTIONS

SaniTEE Wastewater Screens Installation & Service Manual FOR USE WITH SNT416, SNT418, SNT818, SNT 838, SNT1618, and SNT1638

INSTALLATION AND SERVICE INSTRUCTIONS AND REPAIR PARTS LIST FOR 1HP CENTRIFUGAL SUBMERSIBLE EFFLUENT PUMPS

AQUATOR Commercial Oil Water Separator Operating, Installation & Maintenance Manual

Ion Technologies SHR-HR Submersible Sewage Pump Single Seal, Single Phase, & Three Phase Power

Installation Manual. Omnivore Grinder Pump Retrofit Unit LSG202-RE. LSGX202-RE 2Hp, V, 1 phase, Automatic LSG202-REX

DC400 Dispensing Cutoff System

SUBMERSIBLE SUMP PUMPS

MODELS WGL20, WGL20H and WGL20F

HEAVY DUTY ONBOARD AIR SYSTEM PART NO

Ion Technologies SEF100-SEF200 Heavy Duty Sewage Pumps

SuperFlo 9,000 High Volume Pump Product Manual

Pump Sentry. Models 812 PS & 1612 PS INSTALLATION INSTRUCTIONS

SP40 Submersible Sewage Ejector Pump

OWS OPERATIONS & MAINTENANCE

RELN Septic & Holding Tanks

SH30 High Head Effluent Pump

MODEL H INSTALLATION INSTRUCTIONS

REGULATIONS CONCERNING TRAILER PARKS COBB PUBLIC HEALTH

Utility Distribution Systems Installation, Operation, and Maintenance Manual

Professional Séries. Professional Séries. Model T03828 SUBMERSIBLE SUMP DUPLEX SYSTEM SUBMERSIBLE SUMP DUPLEX SYSTEM. 1/3HP 2400 GPH Head of 20 (6 m)

A+ Battery Backup Power Supply For use with Hydromatic model B-A1/BV-A1

DEFENDER SERIES. 5 Gallon, Double Walled, Field Replaceable Spill Container Model Series INSTALLATION, OPERATION, & MAINTENANCE

Submersible Sump / Effluent Pump

SPECIFICATIONS Power supply required...see Motor and Cord Specifications chart below Motor duty...intermittent Discharge Adapter...

S33 Sump Pump INSTRUCTIONS AND SERVICE MANUAL VERTICAL FLOAT SWITCH S33V1 & S33V1C AUTOMATIC S33P1 & S33PC-1 (CONTROL WITH SERIES PLUG) NOT SHOWN

UV DISINFECTION UNIT MODEL 3G

KGX2-21. Grinder Pumps. 2HP Dual Seal Grinder Pump, External Start (Class 1, Div. 1, Groups C & D Hazardous Location) Performance Curve

HV200 SERIES GRINDER PUMPS INSTALLATION AND SERVICE MANUAL

Pump Specifications. D3648LSG, D3648LSGX Series Omnivore 2HP Duplex Grinder Packages LITERS PER SECOND

W/D/V-A1. Submersible Sump Pump. Pump Installation and Service Manual W-A1 V-A1 D-A1

LITERS PER MINUTE GALLONS PER MINUTE

OWNER S MANUAL MODELS 7011, 7012 & 7013 SUBMERSIBLE GRINDER UNITS. Table of Contents. Safety Instructions. Owner s Information

OWNER S MANUAL 71 SERIES SUBMERSIBLE GRINDER UNITS SAFETY INSTRUCTIONS TABLE OF CONTENTS OWNER S INFORMATION. visit our web site:

ClassicSeries Compressor Installation

Series: PFSWCPC75. 3/4 HP 1750 RPM 60 Hz Submersible Sewage Pump OWNER S MANUAL. Power-Flo Pumps & Systems PUMPS

INSTRUCTION MANUAL IM248. High Temp Sump Pump INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

007 Tank Monitor. WARNING Never use with gasoline or highly flammable liquids.

Artesian2 Owners Manual

MODEL NUMBER: MEDIUM DUTY ONBOARD AIR SYSTEM

OWNER S MANUAL Commercial Duty Pumps

Pump Installation and Service Manual JB-1 System Sewage Ejector Pump Package

INSTALLATION INSTRUCTIONS

Ion Technologies ES45 Effluent Pump

INSTALLATION & SERVICING MANUAL 2 HP Submersible Grinder Pumps. 200 / 230 Volt, 1- Phase, Internal Capacitor Kit, High Head G2-21SE Series

Fully Automatic Bilge Pump INSTRUCTION MANUAL

V2 SERIES GRINDER PUMPS INSTALLATION AND SERVICE MANUAL

barmesapumps.com BP33 & BP & RPM Installation, Operation & Maintenance Manual Submersible Sump / Utility Pumps

STEP-BY-STEP INSTALLATION GUIDE

Submersible Sewage Ejector Pump

OWNER S MANUAL Series: PFSPPPP33 1/3 HP 3450 RPM 60 Hz Series: PFSPCPC50 1/2 HP 3450 RPM 60 Hz Submersible Sump Pumps

PUMP TYPES. Pump Sizing. Dose to Gravity. Pumping to Gravity Distribution. Systems that need a Lift. Distribution Box and Tiered Trenches.

Transcription:

E/One Sewers TM Installation Instructions for Flexible Hose & Horizontal Slideface Read all instructions before proceeding with installation. 1

AMGP INSTALLATION LAYOUT SHEET 3

After Market Grinder Pump (AMGP) Installation Instructions The Environment One AMGP is a wellengineered, reliable and proven product; proper installation will ensure years of trouble-free service. The AMGP is designed to replace a 2HP centrifugal grinder pump in a residential or light commercial sewage handling application. The following instructions define recommended procedures for installing the AMGP. Read all instructions before starting unit replacement. If you have any questions, call your local distributor or Environment One Preparation of Tank 1. Instruct homeowner to cease water usage. 2. Remove tank lid. 3. Inspect lid integrity: Clean all debris from lid Inspect lid to ensure it is capable of supporting loads it may encounter (people, lawn tractor, trailer, etc.). Inspect to ensure that lid can be sealed to prevent ground water infiltration. Note: If tank lid is deficient in any way, replace it. 4. Wash tank wall, rail assembly, pump and tank floor using a high-pressure water line. for assistance, (518) 346-6161. This is a sewage handling pump and must be vented in accordance with local plumbing codes. This pump is not to be installed in locations classified as hazardous in accordance with National Electric Code, ANSI/NFPA 70. All piping and electrical systems must be in compliance with applicable local and state codes. Note: Occupational Safety and Health Standard (OSHA) mandates that anyone entering a confined space (such as sewage tank, manhole, septic tank, etc.) must follow the confined spaces rules and regulations. This can be found in Code of Federal Regulations Book 29, Section 1910.146, distributed by OSHA. This gives guidelines on how to safely enter tanks to make needed changes or repairs. If possible, make all changes without entering the tank. Before starting unit replacement, unpack hardware to ensure all items needed to complete the installation are accounted for. Inspect station to see if additional items not supplied by Environment One will be needed to complete the job, such as plumbing hardware kit, replacement tank, special tools, electrical hardware, etc. 5. Use existing grinder unit to pump down to off level. If manual-run is available, use it to pump tank down to lowest level possible. 6. Turn off all electrical power to old control panel at main house supply. Test with voltmeter, at panel, to ensure all power is off. 7. Close curb stop or discharge valve at street. 8. Disconnect and remove float assembly from tank. 9. Remove existing pump from tank. 10. Remove rail assembly and discharge assembly. 11. Remove all remaining brackets in tank that are not pertinent to tank structure. This can be accomplished by making an extension wrench out of a metal rod that is long enough to reach the bottom of the tank. 12. Pump out remaining sewage and debris from tank. Clean tank floor. 13. Seal all holes in tank interior left by the removal of hardware in the tank. 4

14. Inspect tank interior for structural integrity and leaktightness. Failure to prevent all infiltration may cause premature pump failure and void warranty. Option A: Flexible Hose Discharge (Select either A or B) Refer to any documentation that may have shipped with your discharge. 15. Disconnect the power and remove the existing alarm/disconnect panel. 16. Grade around the tank to prevent ground water infiltration during heavy rain. Installing the AMGP 1. Unpack all materials. Warranty registration and user instructions must be given to the owner. Hardware packed with the unit will be used during installation. 2. Do not drop, roll or impact pump. Lift using the rope on the pump. 3. Attach pump stand. (Fig. 1) FIG. 2 5a. Attach the discharge hose to the anti-siphon check valve. Use pipe sealer on threads to ensure leaktightness. (Fig. 3) 6a. Check the O-ring on the slideface adapter for adequate lubrication. (Fig. 5) 7a. Attach discharge installation tool on male adapter. (Fig. 3 and 4) 8a. Continue to Step 11 under Complete Pump Installation. FIG. 1 4. Install slide face discharge receiver to tank s discharge hub. The slide face has a 1 ¼-inch solvent weld socket. A 1 ¼-inch PVC nipple is supplied if a threaded connection is necessary. Glue nipple to slide face with Schedule 80 primer and glue. Take care not to get glue on slide face surfaces. (Fig. 2) FIG. 3 FIG. 4 5

Option B: Rigid Pipe Discharge (Select either A or B) Refer to any documentation that may have shipped with your discharge. 5b. Check the parts you received. If your parts contain a pre-assembled rigid vertical piping assembly (1-1/4 Schedule 80 pipe is glued to both a threaded fitting and an elbow), you will not need to follow Step 6b. 6b. To assemble your rigid vertical pipe: a. Use only 1-1/4 Schedule 80 PVC pipe. FIG. 5 Horizontal Slideface b. Your kit may include a sample piece of pipe if you ordered a no pipe option from the factory. This piece may be discarded. c. Cut the pipe as follows: Carefully measure the height from the bottom of the tank to the discharge location and subtract 28.75. This is the pipe length required. For example, if your discharge height is 36, 36 28.75 = 7.25. Therefore, cut the pipe to 7 1/4 inches. d. Use PVC primer and cement to glue the pipe to the threaded fitting and socket elbow. Be sure to fully seat the pipe into both fittings during assembly. FIG. 6 7b. Apply thread sealant to the threaded fitting on the rigid vertical piping assembly. Thread into the anti-siphon check valve on the grinder FIG. 7 FIG. 8 6

pump. Tighten the assembly. The elbow at the top of the rigid assembly should be oriented as shown in the figure to allow the flexible assembly to cross over the top of the grinder pump. (Fig. 6) 8b. Apply thread sealant to the threads on the flexible hose end. Install the threaded hose adapter into the elbow on the top of the rigid discharge assembly and tighten. Orient the slideface adapter as shown with the threaded boss pointed upward. (Fig. 7) 13. Hang power/ breather cable and lifting rope to prevent them from laying in sewage. Keep between 18 inches and 24 inches of power supply cable in tank. Refer to Installation Layout Sheet in the front of this manual. 14. Remove the plug from the Equalizer tube installed in the breather port and insert barbed fitting on the Equalizer (Fig. 10). Taller tanks may require the attachment of Equalizer Extension Kit PA1819G01. 9b. Check the O-ring on the slideface adapter for adequate lubrication. (Fig 8) Attach discharge installation tool on male adapter. (Fig. 4 and 5) 10b. Continue to Step 11 under Complete Pump Installation. Complete Pump Installation 11. Carefully lower AMGP into tank. Place pump so anti-siphon check valve is on opposite side of discharge in tank. Refer to Installation Layout Sheet in the front of this manual. (See Fig. 6 for Option B discharge.) 12. Rotate discharge hose and male adapter to create a loop or coil. Slide male adapter into slide face receiver until it seats. Push down on slider valve assembly to open. (Fig. 9) FIG. 10 15. Install vent assembly in cover assembly. Hole size for vent grommet is 3 inches. The vent must be installed per national and local codes to ensure proper operation. Failure to properly vent tank will result in faulty operation and will void warranty. FIG. 9 16. Connect AMGP to alarm panel. New cable should be installed between tank and electrical panel per National Electric Code and local codes. Maximum distance between pump and panel is 100 feet. Minimum burial depth without conduit is 24 inches. Note: Environment One cable should be used to ensure proper operation. When an underground splice is needed, use E/One- 7

approved splice kit, E/One part number PC0606G01. If existing cable is used, test for ground short (results from damaged cable underground). Replace if a short is found. Plug and seal all electrical components (junction box, conduit, etc.) inside tank and control panel to ensure a watertight connection. Failure to seal all moisture may cause premature pump failure and void warranty. Waterlogged junction boxes are one of the most common sources of grinder pump problems. 17. Power source to the panel must be 240 VAC (or 120 VAC for a 120V Model). A dedicated 30-amp breaker with ground and separate neutral is required. Test Procedure 1. Make certain that all discharge shutoff valves are fully open (curb stops, slider valve, etc.). 2. Turn off power at main power supply and panel. Use an ohmmeter set at the 2 meg scale. Check the continuity between the following leads from the AMGP (tests should be performed with the pump and alarm breakers inside the panel OFF): 7. Turn on pump power circuit breaker. Pump should immediately turn on. 8. Take a current (amperage) reading off the white lead to the AMGP. The reading should be between 5 and 8 amps for 240 VAC service (10 to 16 amps for 120 VAC service). Higher amperage readings equal a higher discharge pressure. If the amperage is greater than 8 (16 for 120 VAC service) check the discharge line for a blockage. Note the amperage. 9. Within the first 1 to 3 minutes, the alarm will turn off. Within the following 1 to 2 minutes, the pump will turn off (in a 24-inch diameter tank). 10. Close and lock the alarm/disconnect panel. 11. Inspect the lid gasket and install new gasket material as required. Fasten lid to tank. Call your local E/One distributor if you have any problems. Please have ready the unit serial number, voltage, amperage read during startup, type of application, and a description of the problem. Green to black Green to white Green to red Red to orange All these tests must read an open circuit. A short at any of these test points will cause premature pump failure if not corrected. 3. Turn on power at main power supply only. 4. Check voltage from the main power supply. The voltage must be 240 VAC (or 120 VAC for a 120V Model) within 10 percent. Note the voltage. 5. Turn on the alarm power circuit breaker. Leave pump breaker off. 6. Fill tank with water until alarm turns on. This will be about 30 inches from bottom of tank. Turn off water. 8

A Precision Castparts Company Environment One Corporation 2773 Balltown Road Niskayuna, New York 12309 1090 Voice: (01) 518.346.6161 Fax: 518.346.6188 www.eone.com PA1282P01 Rev. D

User Instructions for the Environment One Grinder Pump Congratulations on your Environment One grinder pump investment. With proper care and by following a few guidelines, your grinder pump will give you years of dependable service. Care and Use of your Grinder Pump The Environment One grinder pump is capable of accepting and pumping a wide range of materials. Regulatory agencies advise that the following items should not be introduced into any sewer, either directly or through a kitchen waste disposal unit: Glass Metal Seafood shells Goldfish stone Diapers, socks, rags or cloth Plastic objects (toys, utensils, etc.) Sanitary napkins or tampons Kitty litter General Information In order to provide you with suitable wastewater disposal, your home is served by a low pressure sewer system. The key element in this system is an Environment One grinder pump. The tank collects all solid materials and effluent from the house. The solid materials are then ground to a small size suitable for pumping as a slurry with the effluent water. The grinder pump generates sufficient pressure to pump this slurry from your home to the wastewater treatment receiving line and/or disposal plant. In addition, you must never introduce into any sewer: Explosives Flammable material Lubricating oil and/or grease Strong chemicals Gasoline Periods of Disuse If your home or building is left unoccupied for longer than a couple of weeks, perform the following procedure: Purge the System. Run clean water into the unit until the pump activates. Immediately turn off the water and allow the grinder pump to run until it shuts off automatically. Duplex Units. Special attention must be taken to ensure that both pumps turn on when clean water is added to the tank. Caution: Do not disconnect power to the unit Power Failure Your grinder pump cannot dispose of wastewater without electrical power. If electrical power service is interrupted, keep water usage to a minimum. Pump Failure Alarm Your Environment One grinder pump has been manufactured to produce an alarm signal (120 volt) in the event of a high water level in the basin. The installer must see that the alarm signal provided is connected to an audible and/or visual alarm in such a manner as to provide adequate warning to the user that service is required. During the interim prior to the arrival of an authorized service technician, water usage must be limited to the reserve capacity of the tank. For service, please call your local distributor:

E/One Sewers TM Limited Warranty 1000 Series, 2000 Series, AMGP Environment One Corporation offers a limited warranty that guarantees its product to be free from defects in material and factory workmanship for a period of two years from the date of installation, or 27 months from the date of shipment, whichever occurs first, provided the product is properly installed, serviced and operated under normal conditions and according to manufacturer s instructions. Repair or parts replacement required as a result of such defect will be made free of charge during this period upon return of the defective parts or equipment to the manufacturer or its nearest authorized service center. Model Number: Serial Number: Installation Date: SEWER SYSTEMS 2773 Balltown Rd Niskayuna NY USA 12309 (01) 518.346.6161 www.eone.com 12