INDEX. Chapter1 6. air master. Volume Control Dampers

Similar documents
INDEX. Chapter3. air master. Linear Bar Grilles

INDEX. Chapter1 1. A. Jet diffusers 1. Jet diffuser...: AJD-P

DAMPERS WE CONTROL AIR

HEAVY DUTY BALANCE AND CONTROL DAMPER B A L A N C E C O N T R O L SERIES

AIRODYNE CATALOGUE VOLUME CONTROL TAMPERS CONSTRUCTION / MATERIALS

INDEX. Chapter2. air master. Grilles and Registers

EX C E L L E N C E ISO 9001 CERTIFIED COMPANY LINEAR BAR GRILLES.

SafidDampers SPK Description. Standard Construction SPK ( Flange Type )

AL-Maraj Central A/C Systems Accessories Mfg Co.

EnergyShield ES. Air Control and Shut off Dampers. Dampers Controls Fancoils. Ruskin Air Management Limited

Zero Leakage Isolation Damper

MOTORIZED VOLUME DAMPER

Volume Control Dampers. Series HVC-VCD Aluminium volume control dampers. Incorporating. Excellent general purpose volume control damper

SafidDampers SPK Standard Construction SPK Description SPK ( Flange Type )

VC Series. Volume Control Dampers M A N U F A C T U R E R S O F A I R, F I R E A N D S M O K E C O N T R O L P R O D U C T S

SMOKE DAMPER - CLASS F MODEL BMSD

HCD-135. Industrial Control Damper. Application and Design. Ratings (see page 2 and 3 for specific limitations) Standard Construction.

COMBINATION FIRE/SMOKE DAMPER - CLASS F MODEL BMFSD (3 HR) / MODEL BEMFSD (1½ HR)

Fire & Gas Dampers. Fire & Gas Dampers are used in ventilation systems to prevent the spread of flame and/or smoke between divisions.

VOLUME CONTROL / REGULATING DAMPERS

Blade Features. AirShield Control and Shut Off Dampers. AirShield

VOLUME CONTROL DAMPER

HCD-230 Industrial Control Damper

Actionair Control and Shut Off Dampers

VOLUME CONTROL & SHUT OFF DAMPERS SERIES 400

DD Series. Duct Regulating Dampers M A N U F A C T U R E R S O F A I R, F I R E A N D S M O K E C O N T R O L P R O D U C T S. Two blade options.

L O U V E R S & D A M P E R S

LOW LEAKAGE VOLUME CONTROL DAMPER

Model VCD-18. Ratings. Blade Operation. Size Limitations. Features & Options

AMD-33. Air Measuring Station with VCD-33 Control Damper. Application and Design. Features & Control Options

Multileaf damper with actuator

Model VCD-20. Control Damper. Application. 3V Blade. Ratings. Flange Options. Size Limitations. Blade Operation. Features and Options

AMD-33 Air Measuring Station with VCD-33 Control Damper

When Time is Everything... We Manufacture in Days - Not Weeks!

AMD-42V Air Measuring Station with VCD-42V Control Damper

AMD-42 Air Measuring Station with VCD-42 Control Damper

AMCA MEMBER. American Warming and Ventilating. A Mestek Company. Quality Air Control Dampers

VCD-23. Flange Options. Size Limitations

Dampers. Louvers. Caring for Human Life & Property (FIRE, SMOKE & HVAC) NAFFCOFlow.com

Technical information

Marine Fire and Gas Dampers

ARROW UNITED INDUSTRIES

Motorized Fire Dampers

VOLUME CONTROL DAMPERS

Control Dampers. Leakage Performance. Model FDNB (Opposed Blade) FDQB (Parallel Blade) Galvanized 3V Blade Control Dampers

Model VCD-34. Low Leakage Insulated Airfoil CONTROL DAMPER. Ratings (See page 3 for specific limitations) Flange Options.

Series HCD Airfoil Control Damper

Model VCD-20 3V CONTROL DAMPER

Model SEVCD-33. Low Leakage Airfoil Control Damper. Application and Design. Ratings (See page 3 for specific limitations) Blade Operation

AMD-42-TD. Thermal Dispersion Air Measuring Station with VCD-42 Control Damper. Application and Design. Ratings. Features and Control Options

Louvre systems. Series WL Standard weather louvres. Incorporating. Standard range of single bank louvres as used in countless installations worldwide

Type JZ Low leakage FOR LOW-LEAKAGE SHUT-OFF IN AIR CONDITIONING SYSTEMS

CURTAIN TYPE FIRE DAMPER

SPECIALTY PRODUCT CATALOGUE. Manufacturers of quality residential, commercial, industrial, and institutional HVAC duct & fittings.

VCD-23 Low Leakage CONTROL DAMPER

CONTROL SMOKE AND BALANCING DAMPERS

ARROW INDUSTRIAL PRODUCTS

Model VCD-33. Low Leakage Airfoil CONTROL DAMPER. Flange Options. Blade Operation. Size Limitations

Control Dampers and Fire Dampers. Volume 1 - March Insulated Control Dampers. Non-Insulated Control Dampers. Framing. Accessories.

BD-1600 Balancing/Zone Control Damper

INDEX. Chapter1 0. air master. Round Ceiling Diffusers

Baked Enamel, Epoxy, Hi Pro Polyester, Industrial Epoxy, Kynar/Hylar (70%) Permatector. Single or Reverse Flange 8 x 6 (203 x 178)

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x in. W x 120 in. H (3658mm x 3048mm) 5 in.

Volume Control Dampers. Series LF upvc-vcd High performance plastic volume control dampers. Incorporating

CCS Zone/Bypass Damper Assembly

DAMPERS FOR COMMERCIAL & INDUSTRIAL APPLICATIONS IN HEATING, VENTILATING & AIR CONDITIONING

BP - Floor grilles E-04/07

BD Series. Backdraught Volume Regulating Damper M A N U F A C T U R E R S O F A I R, F I R E A N D S M O K E C O N T R O L P R O D U C T S

U X Y W L. Gear wheels. Linkage. In option: Stainless steel AISI 304L , AISI 316L or painted steel (standard RAL)

AMD-23-TD. Thermal Dispersion Air Measuring Station with VCD-23 Control Damper. Application. Ratings. Features and Options

SMOKE DAMPERS SMOKE DAMPERS SMOKE DAMPERS

Fire Dampers Catalogue

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x 305) 5 in. (127mm) Parallel

SP Standard Profile. In Duct or Flanged to Duct Install Types OPPOSED ACTION PARALLEL ACTION. Extended Rear Flange Install Type

VCD-23. Low Leakage CONTROL DAMPER

Positive Seal Damper Blades with Vinyl Gaskets 2.5" SERIES 3000 SIDE MOUNT - NO FLANGE ORDERING METHOD FOR BACKDRAFT & MOTORIZED BACKDRAFT DAMPERS

SD-1250 and SD-1600 Series Smoke Dampers

Type WG-JZ COMBINATION WITH A MULTILEAF DAMPER. PÁGINA PRINCIPAL > Productos > Rejas para intemperie - compuertas de regulación

Introduction to Johnson Controls Dampers

UTK/UTT - Multi-blade Damper. Halton UTK, UTT. Multi-blade Damper

VD-1600 Series Volume Control Dampers

Model DFD-230 Multi-Blade Fire Damper Steel 3V Blades UL555 3 Hour Fire Resistance Rating

Dimensional Data Curb Optional Glass Damper Hood. A B C Size (O.D.) Size (O.D.) Qty Size Actuator Qty

NR series. Circular CAV air volume control terminals with system powered mechanical regulator

Hison Axial Flow Fans

Hison Axial Flow Fans

SERIES C. Adjustable Deflection Grilles for Circular Ducting

Incorporating V2.0. Product spec >>> > Series DJ - Drum jet diffusers

Model VCD-43 Extruded Airfoil Blade Control Damper

FSD36, FSD36LP COMBINATION FIRE AND SMOKE DAMPER 1 1 /2 HOUR UL555 RATED, UL555S LEAKAGE CLASS 2

Model VCD-40. Extruded Airfoil Blade Control Damper Narrowline Frame Construction. Application. Ratings. Flange Options.

FSD60, FSD60LP CoMBINAtIoN FIRe AND SMoKe DAMPeR

HVAC Control Damper Models VCD and MBD. Selection Construction Performance

Model VCD-20V. 3V Vertical Control Damper. Application and Design. Ratings (See page 4 for specific limitations) Flange Options.

EXHAUST AND AIR LOUVERS CHAPTER 5

U X Y W L. Gear wheels. Linkage. In option: Stainless steel AISI 304L , AISI 316L or painted steel (standard RAL)

NV series. Induction VAV air volume control terminals

YCCS Zone/Bypass Damper Assembly

PC-125x Counter-Balanced Backdraft Damper

B. Fabricate in accordance with ASHRAE handbooks and SMACNA duct manuals. A. Submit in accordance with Division-1 and Section

Transcription:

Chapter1 6 INDEX 1 Volume control damper...:avcd...16.1 Standard sizes...16.2 Fixing details...16.2 How to order...16.2 Performance chart...16.3 2. Circular volume control damper....:avcd-c....16.4 Standard sizes...16.4 Fixing details...16.5 How to order...16.5 Performance chart...16.5

Volume control damper Model: AVCD Construction: Frame: 1.2mm thick galvanized steel sheet. Frame size: 125mm depth and standard flange height of 25mm. Blades: Double skinned high quality extruded aluminium aerofoil profiles. Bearing pins: Electro plated square rod of size 12.7mmx12.7mm. Bushings: Self oiling nylon bushings of internal square size Blade linkage: nylon gear. Blade stopper: 20mmx20mm alumnium angle. Description: Frame is constructed from galvanized steel sheet. Joints are welded and protected by aluminium spray coating. Blades are coupled by toothed nylon gears which can provide either parallel or opposed blade operation. Hand locking quadrant with open and close marking and frame is marked to show exact position of damper. Structure is available with flanged edges and are supplied un drilled as standard. Dampers without flanges available as option for duct insertion purpose. Flanged edges with drilled holes are also available. Available in square and rectangular sizes. Designed for use in heating, ventilating and air conditioning systems. Accessories: Motorized dampers: Volume control dampers will be supplied with actuators of client s choice. The dampers can also be provided with an extended linkage to fix the motor at the site. 2007 Rev. 1 ISO 9001:2000 certified company 16.1

Standard sizes: Available in square and rectangular sizes. Sizes available from 100x100mm with an increment of 25mm. Non standard sizes available as option. Fixing details: Model: AVCD Fixing by bolt Slip and clip joint How to order: Model Size Quantity Fixing AVCD Specify duct width x height in mm x mm Specify in numbers A = Fixing by bolts B = Slip and clip joint Oredering example: 1. To select volume control damper for a duct size of 900x600, quantity 75 nos. Fixing details: Bolting. Order as : AVCD - 900x600-75 - A 2007 Rev. 1 ISO 9001:2000 certified company 16.2

Performance chart: Model: AVCD Pressure drop - Rectangular VCD aerofoil type blades 16.3

Circular volume control damper Model: AVCD-C Construction: Frame: 1 mm thick galvanized steel sheet. Blades: 1 mmthick galvanized steel sheet. Bearing pins: Electro plated steel rod of 10 mm diameter. Bushings: Self oiling nylon bushings of 10 mm internal square size. Bearing pin connecting quadrant: Electro plated square steel rod of size 12.7 x 12.7 mm. Quadrant: Locking quadrant with heavy gauge, electro plated steel. Description: Frame is constructed from galvanized steel sheet. Joints are welded and protected by aluminium spray coating. Damper blade, which is fixed to the bearing pin, can be rotated in vertical plane from full open to full close. Bearing pin is coupled with hand locking quadrant with open and close marking. Hand locking quadrant frame is marked to show exact position of damper. Designed for use in heating, ventilating and air conditioning systems. Round VCD with flange. Model AVCD-CF Accessories: Motorized dampers: Volume control dampers will be supplied with actuators of client s choice. The dampers can also be provided with an extended linkage to fix the motor at the site. Dimensions. D = Diameter L = Length C Up to 150 mm L = 200 mm 50 mm Above 150 mm L = D + 100 mm 50 mm Standard Sizes: D = Duct opening in mm dia 100 200 300 400 500 600 16.4

Fixing details: Fixing by rivets to flexible duct. How to order: Model Size Quantity Fixing AVCD-C Specify duct diameter in mm Specify in numbers A = Bolt fixing Ordering example: 1. To select round volume control damper of size 400 mm dia, quantity 25 nos. Fixing details: Bolt fixing. Order as : AVCD-C- 400 75 A. Performance chart: Model: AVCD-C Pressure drop - Circular VCD 16.5