DC/DC converter SINGLE OUTPUT SOPHISTICATED DC/DC TOPOLOGY! η = 94%!! DC/DC high efficiency module Wide Input range Various output voltages High output current High efficiency up to 94% Approved: UL60950, C-UL: CSA C22.2 No.950) Small size low profile 0.42 Dimension comparison: Your benefits: Compact size for simple and fast installation! No need of auxiliary-circuits due to easy connection High power density (20W/cm3) No extra cost for additional heatsink or fan! 94% efficiency = extremely low power losses throughout full input range Low operation temperature guarantee s an ultra high MTBF! Cost- and time savings through READY-TO-USE converter
NVD**SC12 NVD-3.3SC12 NVD-05SC12 NVD-12SC12 NVD-15SC12 NVD-24SC12 100 WATTS / SINGLE Input Characteristic Input Voltage DC12V Input Range DC9.6 ~ 16V Inrush Current *1 Not specified Efficiency [%] (typical) *1 89 90 91 90 92 Output Characteristic Output Voltage [V] 3.3 5 12 15 24 Output Current [A] 20 18 7.5 6 3.8 Voltage Adjust Range Rated Output Voltage x (0.9 ~ 1.1) Ripple and Noise [mvp-p](maximum) 150 150 220 250 350 Regulation a.statistic Line Regulation 26 40 96 120 190 b.statistic Load Regulation 30 45 108 135 216 c.temperature Coefficient 0.03[%/ C] (-10 ~71 C) d.drift[mv](maximum) 32 40 75 90 135 e. Dynamic Load Reg. [mv] Typ. *2 +/-120 +/-150 +/-360 +/-450 +/-720 f. Recovery Time 20[ms] Typ. (output current change 25% to 75%) Rise up time 200[mS] Typ. Hold up time Functions Over current Protection Over voltage Protection Remote Sense Remote Control Power Fail Power Factor Correction Environmental Operating Temperature -10 ~+50 C (at 100% load), 50 C ~+71 C (decrease output current 3.5%/ C Operating Humidity 20 to 90%RH Storage Temperature -20 to +85 C Storage Humidity 20 to 90%RH Withstanding Voltage Primary - Secondary AC2.000V for 1minute (Sense current) Primary- Frame ground AC2.000V for 1minute (Sense current) Secondary-Frame Ground AC1000V for 1minute (Sense current) Isolation Resistance Primary-Secondary-Frame ground 50MΩ (minimum) by DC500V Vibration 5-10Hz:10[mm], 10 ~ 55[Hz 2[G[ 20minute/cycle X,Y,Z axes Shock 30[G[ Cooling Convection cooling Safety Expect to Apply for: UL60950 C-UL: CSA C22.2 No.950 Weight MTBF [H] Min. (by EIAJ RCR-9102) Frequency[kHz] Typ. Dimension 65(W) x 101(D) x 34(H) not include output terminal Conditions: *1 At rated Input and rated output *2 At output current quick change 25% to 75%
NVD**SC24 NVD-3.3SC24 NVD-05SC24 NVD-12SC24 NVD-15SC24 NVD-24SC24 100 WATTS / SINGLE Input Characteristic Rated Voltage DC24V Input Current Typ. *1 1.49 2.24 2.39 2.35 2.66 Input Range DC19 ~ 32V Inrush Current *1 Efficiency [%] (typical) *1 90 91 93 92 93 Output Characteristic Output Voltage [V] 3.3 5 12 15 24 Output Current [A] 22 20 9 7 5 Voltage Adjust Range Rated Output Voltage x (0.9 ~ 1.1) Ripple and Noise [mvp-p](maximum) 150 150 220 250 350 Regulation a.statistic Line Regulation 26 40 96 120 190 b.statistic Load Regulation 30 45 108 135 216 c.temperature Coefficient 0.03[%/ C] (-10 ~71 C) d.drift[mv](maximum) 32 40 75 90 135 e. Dynamic Load Reg. [mv] Typ. *2 +/-120 +/-150 +/-360 +/-450 +/-720 f. Recovery Time 20[ms] Typ. (output current change 25% to 75%) Rise up time 200[mS] Typ. Hold up time Functions Over current Protection Over voltage Protection Remote Sense Remote Control Power Fail Power Factor Correction Environmental Operating Temperature -10 ~ +50 C (at 100% load), 50 C ~+71 C (decrease output current 3.5%/ C Operating Humidity 20 to 90%RH Storage Temperature -20 to +85 C Storage Humidity 20 ~ 90%RH Withstanding Voltage Primary - Secondary AC2.000V for 1minute (Sense current) Primary- Frame ground AC2.000V for 1minute (Sense current) Secondary-Frame Ground AC1000V for 1minute (Sense current) Isolation Resistance Primary-Secondary-Frame ground 50MΩ (minimum) by DC500V Vibration 5-10Hz:10[mm], 10 ~ 55[Hz 2[G[ 20minute/cycle X,Y,Z axes Shock 30[G[ Cooling Convection cooling Safety Expect to Apply for: UL60950 C-UL: CSA C22.2 No.950 Weight MTBF [H] Min. (by EIAJ RCR-9102) Frequency[kHz] Typ. Dimension 65(W) x 101(D) x 34(H) not include output terminal Conditions: *1 At rated Input and rated output *2 At output current quick change 25% to 75%
NVD**SC48 NVD-3.3SC48 NVD-05SC48 NVD-12SC48 NVD-15SC48 NVD-24SC48 100 WATTS / SINGLE Input Characteristic Rated Voltage DC48V Input Current Typ. *1 1.49 2.24 2.39 2.35 2.66 Input Range DC38 ~ 63V Inrush Current *1 Efficiency [%] (typical) *1 92 93 94 93 94 Output Characteristic Output Voltage [V] 3.3 5 12 15 24 Output Current [A] 22 20 9 7 5 Voltage Adjust Range Rated Output Voltage x (0.9 ~ 1.1) Ripple and Noise [mvp-p](maximum) 150 150 220 250 350 Regulation a.statistic Line Regulation 26 40 96 120 190 b.statistic Load Regulation 30 45 108 135 216 c.temperature Coefficient 0.03[%/ C] (-10 ~ 71 C) d.drift[mv](maximum) 32 40 75 90 135 e. Dynamic Load Reg. [mv] Typ. *2 +/-120 +/-150 +/-360 +/-450 +/-720 f. Recovery Time 20[ms] Typ. (output current change 25% to 75%) Rise up time 200[mS] Typ. Hold up time Functions Over current Protection Over voltage Protection Remote Sense Remote Control Power Fail Power Factor Correction Environmental Operating Temperature -10 ~+50 C (at 100% load), 50 C ~ +71 C (decrease output current 3.5%/ C Operating Humidity 20 ~ 90%RH Storage Temperature -20 ~ +85 C Storage Humidity 20 ~ 90%RH Withstanding Voltage Primary - Secondary AC2.000V for 1minute (Sense current) Primary- Frame ground AC2.000V for 1minute (Sense current) Secondary-Frame Ground AC1000V for 1minute (Sense current) Isolation Resistance Primary-Secondary-Frame ground 50MΩ (minimum) by DC500V Vibration 5-10Hz:10[mm], 10 ~ 55[Hz 2[G[ 20minute/cycle X,Y,Z axes Shock 30[G[ Cooling Convection cooling Safety Expect to Apply for: UL60950 C-UL: CSA C22.2 No.950 Weight MTBF [H] Min. (by EIAJ RCR-9102) Frequency[kHz] Typ. Dimension 65(W) x 101(D) x 34(H) not include output terminal Conditions: *1 At rated Input and rated output *2 At output current quick change 25% to 75%
Derating Efficiency
OCP Block diagram
Dimension diagram