INSTRUCTION MANUAL. 1. Introduction 2. Safety Instructions.. 2 Unpacking Description. 2. Main Features... 3 Technical Data...

Similar documents
F111.X Flow Sensor for Hot Tap Installation INSTRUCTION MANUAL. 1. Introduction Safety Instructions Unpacking Description.

FLOWX3 F3.20 High Pressure Paddlewheel Flow Sensor MAIN FEATURES APPLICATIONS OPERATING PRINCIPLE

FLOWX3 F3.60M.S Insertion Magmeter

Index Flow Sensors FLOWX3 F3.00 Paddlewheel Flow Sensor page 2 FLOWX3 F111 Hot Tap Flow Sensor page 18 FLOWX3 F3.60M Insertion Magmeter page 24 FLOWX3

FLS F6.60 MAGMETER FLOW SENSOR INSERTION FLOW SENSORS APPLICATIONS MAIN FEATURES

SIGNET 7002 Vortex Flow Sensor ENGLISH

Signet 2517 Brass Paddlewheel Flow Sensor * *

INSERTION flow sensor for continuous flow measurement

Signet 2536 Rotor-X Paddlewheel Flow Sensors

Insertion turbine INSTRUCTION SHEET. TECHNICAL PRODUCT

Pipe fi ttings MUST be installed by a certifi ed welder only. Signet will not assume liability of any kind for improper fi tting installations.

FE DN PVC-U. Butterfly valve

Pipe fittings MUST be installed by a certified welder only. +GF+ SIGNET will not assume liability of any kind for improper fitting installations.

Signet 7000/7001 Vortex Flow Sensors * *

Signet 515 Rotor-X Paddlewheel Flow Sensors

F3.00 Paddlewheel Flow Sensor INSTRUCTION MANUAL. 1. Introduction Safety Instructions Unpacking Description..

Signet 515 Rotor-X Paddlewheel Flow Sensors

DKD/CP DN PVC-U. Direct action pneumatically actuated 2-way diaphragm valve

SIGNET Vortex Flow Sensors ENGLISH

Flow Meters & Instruments. Insertion Paddle Wheel & Magnetic Flow Meters Flow & Anaytical Instruments. Technical Catalogue

FK DN PVC-U. Butterfly valve

Paddle-wheel flow controller for On/Off control

DK AND DK/CP DN 15 65

Pipe fi ttings MUST be installed by a certifi ed welder only. Signet will not assume liability of any kind for improper fi tting installations.

INSERTION flowmeter with paddle wheel, ELEMENT design

VXE DN PVC-U. Easyfit 2-way ball valve

Paddle-wheel flow controller with optical principle for On/Off control

ISO-BSP FITTINGS PVC-U. Adaptor fittings

MEASUREMENT AND INSTRUMENTATION FLS

Signet 2551 Magmeter Flow Sensor

BI-DIRECTIONAL INSERTION FLOW TRANSDUCER

FK DN PVDF. Butterfly valve

F3.63M Electromagnetic Insertion Flow Sensor INSTRUCTION MANUAL. 1. Introduction Safety Instructions Unpacking Description.

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids

BI-DIRECTIONAL INSERTION METER

2100 Turbine Flow Sensor

DK/CP DN PVC-U / PVC-C / PP-H / PVDF. Pneumatically actuated 2-way diaphragm valve

Paddle-wheel flow controller for On/Off control

Product. Information. A.u.K. Müller. Flow meter turbine, with shut-off device. Series Characteristics. Applications.

mass flowmeter for compressed air

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

Hydro-Flow Model 3100 Retractable Insertion Vortex Flowmeter Installation and Operation Manual

Hydro-Flow Model 2200 Fixed Insertion Vortex Flowmeter Installation and Operation Manual

Hydro-Flow Model 3100

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

Hydro-Flow Model 2200 Installation and Operation Guide B

PSF50 Paddle flow switch

flow x3 flow monitoring

STAINLESS STEEL ATEX 2/2 SOLENOID VALVE SPU225-X NF

STAINLESS STEEL ATEX 2/2 SOLENOID VALVE SPU220-X NF

TX 115/215 Hot-tap Insertion Turbine Instructions

Operating Manual Model- P282 Digiflow Controller

Full Profile Insertion

mass flowmeter for compressed air

G2 SERIES INDUSTRIAL GRADE METERS

VKD DN PVC-U. DUAL BLOCK 2-way ball valve

G2 Industrial Grade Meters

Axial Turbine Flow Sensor Series Turbotron VTH 25 / VTI 25 / VTM 25

DIGIFLO ELECTRONIC FLOWMETER

Features. 2-wire type available. Max. operation distance: 1.5 mm 0.06 in (Stable sensing range 0 to 1.2 mm 0.05 in)

ULTRASONIC FLOW SENSOR IFX-M4-01

2/2-way ball valve with electric rotary actuator, ball valve in plastic, DN 10-50

215 Gallon Waste Oil Tank With Metering Pump Installation Instructions

Inductive conductivity meter

Positive displacement flowmeter for continuous flow measurement

Signet 515/2536 Rotor-X Flow Sensors * * Operating Instructions. English. Description Rev. X 05/17

Electronic Pressure Switches

ELADOS EMP IV E00 Diaphragm Pump type

SeaMetrics Flow Meters and Flow Computers

Insertion magnetic inductive flowmeter

FK DN PVC-U Butterfly valve

display on the wall or in a panel away from the inline sensor SE30 for easy meter reading.

Arm - TX series 40 family

Electronic Pressure Switches

motor driven metering pumps

Pressure sensor for liquid and gaseous media QBE620-P...

INSTRUCTION MANUAL. 1. Introduction Safety Instructions Unpacking Description. 3

KB Series self averaging pitot flowmeter for gas, liquids and steam flows

A Member of the. Integrated Metering Technologies

P2050S-030, 1/2, Electronic Pressure Independent Valve Stainless Steel Ball and Stem, Female NPT Ends

2/2-way ball valve with electric rotary actuator, ball valve in plastic, DN 10-50

Strainer SF 305. Sealing FPM EPDM

30,000 lb. HEAVY DUTY PPF 195 POST PULLER

A1 Commercial Grade Meters

motor driven metering pumps

CLARK SOLUTIONS 8E Series Electric Actuated NEMA 4X Ball Valves 1/4 to 4 Brass & Stainless Steel, 2-way & 3-way configurations

Signet 2552 Metal Magmeter

Inductive conductivity meter

Flowmeter Ultrasonic Flow Metering / Dosing Device. Operating Manual

Relative and absolute pressure transmitter type 691

RUN ACCUM. TOTAL STOP BAT LOW HIGH

Signet 2552 Metal Magmeter

Chapter Page. 1 Introduction Description 1

Signet 3719 ph/orp Wet-Tap Assembly

INDUCTIVE CONDUCTIVITY SENSOR. Instruction Manual. Bürkert 2001 Subject to technical change without notice

imag 4700 SERIES FLANGED MAGMETER

A1 SERIES COMMERCIAL GRADE METERS A1 SERIES COMMERCIAL GRADE METERS

MODEL 27106DT GILL PROPELLER ANEMOMETER JANUARY 2003 MANUAL PN 27106DT-90 R. M. YOUNG COMPANY

MEMORY SEAL BALL VALVES MAINTENANCE MANUAL 2 12, Class 150 & 300, Regular Port, Flanged Unibody

VER03M CONTINENTAL HYDRAULICS PROPORTIONAL PRESSURE RELIEF VALVES VER03M - PROPORTIONAL PRESSURE RELIEF VALVES

Transcription:

F111.H.BD Bi-Directional Turbine Flow Sensor for Hot Tap Installation INSTRUCTION MANUAL EN 10-11 Table of Contents 1. Introduction 2 Safety Instructions.. 2 Unpacking.. 2 2. Description. 2 Main Features... 3 Technical Data.... 3 3. Installation.. 4 Location.. 4 Dimensions.... 4 Set the sensor to work....5 Wiring.. 8 4. K-Factor Tables. 9 1

1. Introduction 1.1. Safety Instructions General Statements The sensor F111.H.BD has only been designed to measure the flow of liquids. Do not install and service the sensor without following the Instruction Manual. This sensor is designed to be connected to other instruments which can be hazardous if used improperly. Read and follow all associated instrument manuals before using with this sensor. Sensor installation and wiring connections should only be performed by qualified staff. Do not modify product construction. Installation and Commissioning Statements Remove power to the sensor before wiring any connection. Remove pressure from the pipe if an hot-tap installation adapter is NOT used. Do not exceed maximum temperature/pressure data. For hot tap installation the pressure limitations are related to the minimum maximum value of the used components (like saddles or valves). To clean the sensor, use only chemical compatible products. 1.2. Unpacking Please verify the product is complete and without any damage. The package should include: A steel tube rod with flow sensor integrated A steel joint for screwing the sensor to the saddle A safety chain An instruction manual 2. Description The new turbine flow sensor FLS F111.H.BD is designed for use with every kind of solid free liquids. The sensor can measure flow from 0.08 m/s (0.26 ft/s) producing a frequency output signal highly repeatable and it is able to recognize the direction of the flow. A stainless steel rugged construction and a proven technology guarantee exceptional performances with little or no maintenance required. The electronic is entirely encapsulated in epoxy resin which ensures that the instrument is suitable for corrosive or high humidity atmospheres. The sensor can be assembled in pressurised pipes using a proper fitting (clamp saddle or weld-on adapter with valve enclosed). 2

2.1. Main Features Adjustable sensor position Stainless Steel construction with insertion turbine technology PVDF turbine with ceramic shaft and bearings Wet-tap installation Pressure intake Suitable for assembling on a wide range of wet-tap clamp saddles with 1 1/4 GAS branch Safety chain Compatible with most data logger on the market 2.2. Technical Data General Flow Rate Range: 0.08 to 1.5 m/s (0.26 to 4.9 ft./s) Linearity: 0.75 % of full scale Repeatability: 0.5 % of full scale Pipe Size Range: DN 50 to DN 1200 ( 2 to 48 ), for sizes bigger than DN 600 (24 ) contact the factory Minimum Reynolds Number Required: 4500 Enclosure: IP68 Max. operating pressure/temperature: 20 bar (290 psi) @ 80 C (176 F) Wetted Materials: Sensor Body: 304 SS O-rings: EPDM or FPM Turbine: PVDF Shaft: Ceramic (Al 2 O 3 ) Bearings: Ceramic (Al 2 O 3 ) measuring rod: 304 SS fixing joint: 304 SS Pressure intake: quick connection 1/4 Thread of the fixing joint to the saddle: GAS 1 1/4 Electrical Supply voltage: 4 to 5 VDC ±10% regulated Supply current: < 0.6 ma @ 5 VDC Output signal: square wave Max. frequency: 20 Hz Output type: transistor NPN open collector Output current: 10 ma max. Cable length: 8 m (26.4 ft) standard, 100 m (330 ft) maximum Standards & Approvals Manufactured under ISO 9001 (Quality) Manufactured under ISO 14000 (Environmental Management) CE 3

3. Installation 3.1. Location Different pipe configurations and obstacles in the flow line such as valves, elbows, pipe bends and strainers create variations on the flow profile. Whenever possible follow the EN ISO 5167-1 installation recommendations to locate the sensor. Always maximize distance between flow sensor and pump. 3.2. Dimensions Fig 1 4

3.3. Set the sensor to work The assembly and set to work of the instrument are carried out by two simple steps that allow a quick and precise installation: 1. INSTALLATION OF THE SENSOR ON THE WET-TAP CLAMP SADDLE 2. VERTICAL POSITIONING OF THE SENSOR INTO THE PIPE Warning: the FLS 111 allows installation into pressurised pipes without system shutdown; we recommend to pay maximum attention when screwing the clamping bolts of the measuring rod. The rod is pushed upwards by the internal pressure, for this reason not work up the rob. Note: lubricate the steel rod to reduce frictions with the O-rings. This will help the installation, measurement and positioning operations. 1. INSTALLATION OF THE SENSOR ON THE WET-TAP CLAMP SADDLE Warning: these installations steps can be applied to every wet-tap clamp saddle with the following properties: Branch minimum diameter : 35 mm Branch thread : 1 1/4 GAS (cylindrical) Fig 2 5

a) Assemble the saddle in the desired position to install the sensor. Drill the pipe. Use a 35 mm ( in.) milling cutter. Remove the drilling machine. Be careful to block the fluid using the proper intercepting plate or ball valve. b) Wrap several turns of Teflon tape around the steel joint threads to prevent leaks. Screw the Stainless Steel joint, together with the measuring rod and the sensor, in the saddle branch. c) Be careful to fix the sensor body in the upper position. d) Tight the safety chain and fix it. Fig 3 e) Remove the intercepting plate or open the ball valve to the full open position (perpendicular to pipe). 2. VERTICAL POSITIONING OF THE SENSOR INTO THE PIPE a) Be sure the sensor is in the upper position. Fig 4 6

b) Calculate DISTANCE between sliding bush and sensor body: For pipe sizes smaller than DN 250 (10 ): DISTANCE (mm) = [ 0.5 x Internal Diameter ] + S + K 5 For pipe sizes equal or greater than DN 250 (10 ): DISTANCE (mm) = [ 0.12 x Internal Diameter ] + S + K 5 Fig 5 S = thickness pipe K = distance between external pipe and end of the thread c) Move and fix the sliding bush at the calculated DISTANCE from the Stainless Steel joint: Fig 6 7

d) Turn the special screws out and push the rod downwards to get the sliding bush being in contact with the Stainless Steel joint. Make sure the reference screw on the top of the rod is PARALLEL to the axis of the pipe and fix again the sensor tightening the special screws. Fig 7 The sensor will be positioned: - at 50% of internal diameter of the pipe ready to measure when pipe is smaller than DN250 (10 ) - at 12% of internal diameter of the pipe ready to measure when pipe is equal or greater than DN250 (10 ) e) IMPORTANT Tight the safety chain and fix it. The safety chain prevents the rod to be pushed upwards by the internal pressure. 3.4. Wiring Always ensure the power supply is switched off before working on the sensor. Always use a high quality (regulated) DC voltage supply. NOTE: the arrow on the sensor body indicates the flow positive direction. 8

4. K-Factor Tables K-Factor values for sensor central positioning DN(mm) k-factor 80 (3 ) 2.04 100 (4 ) 1.30 110 1.07 125 0.81 150 (6 ) 0.56 180 0.44 200 (8 ) 0.31 225 0.24 K-Factor values for sensor 12% positioning DN(mm) k-factor 250 (10 ) 0.14 300 (12 ) 0.10 350 (14 ) 0.07 400 (16 ) 0.06 450 (18 ) 0.05 500 (20 ) 0.04 600 (24 ) 0.03 700 (28 ) 0.02 800 (32 ) 0.01 900 (36 ) On request 1000 (40 ) On request 1100 (44 ) On request 1200 (48 ) On request Correction formula for K-Factor calculation according to real internal diameter K-Factor_NEW = (K-Factor x ID²) / ID_NEW² where: ID = Value in the table for the internal diameter (in mm) ID_NEW = New value for the real internal diameter (always in mm) K-Factor = Value in the table K-Factor_NEW = New K-Factor value for the specified internal diameter EXAMPLE: Nominal Pipe Size (DN) = 40 mm New Internal Diameter = 44,7 mm Using the formula: K-Factor_NEW = (32,74 x 45,3²) / 44,7² = 33,62 9

10

11

F.I.P. Formatura Iniezione Polimeri S.p.A. Loc. Pian di Parata, 16015 Casella (GE) Italy Tel +39 010 96211 Fax +39 010 9621209 www.flsnet.it 12