User Manual JS-ICON. 624 ARCH Dimmer Rack. JOHNSON SYSTEMS INC. Spring

Similar documents
TOPAZ 12 WALL PACK INSTALLATION & MAINTENANCE GUIDE (Part # LIT A)

TOPAZ 24 DIMMER RACK INSTALLATION & MAINTENANCE GUIDE (Part # LIT A)

SAVE THESE INSTRUCTIONS

SAVE THESE INSTRUCTIONS

GP12 TECHNICAL MANUAL

GP Dimming Panels 230 Volt (CE)

PD404-AN V analog control 4 Channel x 500 W Dimmer & Switch Packs ANALOG 0-10 V. Serial Number

Industry Compliance The cabinet and modules are Listed to applicable UL Standards and requirements by Underwriters Laboratories Inc.

The WDS A Dimmer Users Manual Rev , 2012 City Theatrical, Inc.

Sunburst SB2400 Dimmer Rack and Receiver. Version 1.02 P/N F371

JBE LED2000 INDUSTRIAL SOLUTIONS FOR LED & INCANDESCENT MAINS LIGHTING FLICKER FREE TRAILING EDGE DIMMER

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

ALD Dimmer Enclosures

GP Dimming Panels 230 Volt (CE)

User Manual. Solar Charge Controller 3KW

LP Dimming Panels. GRAFIK Systems

R820 REV2 SERIES SCR POWER CONTROLS NOVEMBER 2017

Portable Pack USER MANUAL

3 year warranty. (1) Treo Micro fiberglass, gunite fitting, 3/4 PVC. FLED-TM-W-PK10 (10) Treo Micros (WHITE) 80 NEW! Treo Micro fitting adapter

User Manual Solar Charge Controller 3KW

DMR 3005 WM ONE ZONE WIRELESS DIMMER RECEIVER

INSTALLATION. **Microprocessor Status LED:

The Power of Reliability INSTRUCTION MANUAL

General Information. standard and advanced modular dimming. Sensor 96 dimmer rack

GP Dimming Panels. GRAFIK Systems SPECIFICATION SUBMITTAL

A.C.E.S. Series ACES 3 & 6 MODULE PANELS. System Manual. Touch-Plate Lighting Controls. ACES 3 & 6 Module System Manual

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C

IMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE EMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS

Installation & User Instructions

EMIU 720W Mini Inverter

SOLAR LIGHTING CONTROLLER SUNLIGHT MODELS INCLUDED IN THIS MANUAL SL-10 SL-10-24V SL-20 SL-20-24V

SAVE THESE INSTRUCTIONS

SAVE THESE INSTRUCTIONS

IMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE LMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS

PowerOhm Installation Manual for LG ATV Series Braking Modules

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

PRECISION UK Ltd DUPLEX AGSS PLANT

PowerOhm Installation Manual for BM R Series Braking Modules

SAVE THESE INSTRUCTIONS

TOPAZ 12 PORTABLE PACK AND ASSOCIATED CONTROL MODULES USER GUIDE (Part # LIT A)

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

Page 1 of 5 FL-4020 FLUORESCENT BALLAST CONTROLLER

PEC 5068 BDFB 1-10 Loads, 500A Max/Load -48V, 2000A Max Load/Bay

2-Way Dimmer (1 Gang)

User Manual. T6 Tachometer. Online: Telephone: P.O. Box St. Petersburg, Florida 33736

PRODUCT MANUAL Desktop LED Dimmer and Receiver

Power Inverter. User s Manual. Diamond Series CPD1200EILCD

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

C.fm Page 1 Thursday, February 21, :28 AM Raptor user manual

Elektralite LED Pro Line Pancake USER MANUAL (Version 2)

2-Way Dimmer (1 Gang)

Combined Ventilation Controller RVWS-T-224HA

Power Distribution System User s Manual. Model: PDS-100

1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

LED Downlight Ceiling Fixtures

Installation Instructions: Read these instructions in its entirety before performing any installation work.

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit

FL15 FL50 FL100 USER MANUAL USER MANUAL FL15 PRODUCT OVERVIEW HARDWARE AND SET-UP. page 1

SAVE THESE INSTRUCTIONS

LP-2500/2600. Installation and Setup Guide. Lighting Control Panels. Revision 3.1 July 1999

SIGNETMARINE. Livewell Bait Pump Alarm. No Dead Bait.

Compact LED profile with zoom

Dimmer / 2-Way Dimmer

Continuing Education Course #206 Introduction to Designing Machine Control Systems Part 2

SMX Lumi-Hub Installation Guide

SURFACE/CEILING & SUSPENDED MOUNT INSTALLATION

Models beginning with MO, MK, 7B, 6S, 6F or 5B. Product Description. Technical Specifications. Installation Instructions.

OPERATOR S MANUAL StudPro LiteXI Pin Welder Stud Welding Products, Inc

Installation Manual. AC Edge. Split Phase 60 A (6/6) AC Power Distribution Unit. AC Edge. Model AC60DF 6/6 Part#

Operation Manual. Mega 4Bank DMX Universal

Users Manual. Defender 1 8.0KW to 14.0KW Online Emergency Lighting Inverter. Technical Manual # Revision B

Operation Manual. Select/DMX 4Bank

Users Manual. Cobra Plus Stand-By Emergency Lighting Inverter. Technical Manual # Revision B

RE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & 6kW

SLIMFLEX LED Tape Lighting

R. STAHL Schaltgeräte GmbH Geschäftsbereich Leuchten Nordstraße Weimar, Germany

Installation Instructions

D.fm Page 1 Wednesday, March 5, :21 PM Raptor user manual

XP600/1100/2000 INSTALLATION AND OPERATION MANUAL

Quick Reference Guide. English EN Español ES Français FR Nederlands NL

Operation and Installation Manual

MODEL 422 Submersible Pump Controller

Battery Power Inverters

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

Ventura Series King of the high bays.

Example of Combining Different Types of Heater Control. Heater control. Temperature Controller

A6Z OPERATING MANUAL

SB SWITCH CONTROL BOX

PHOTOVOLTAIC SYSTEM CONTROLLERS SUNSAVER MODELS INCLUDED IN THIS MANUAL SS-6 / SS-6L SS-10 / SS-10L SS-10-24V / SS-10L-24V SS-20L SS-20L-24V

STR3. Step Motor Drive. User Manual

1 Safety instructions. 2 Device components. Light Management Rotary dimmer. Operating instructions

Design Standard. Purpose: Design Standard:

PRO Dimmer INSTRUCTION MANUAL

CHILLER MODEL NO. YS SOLID STATE STARTER, MODEL NO. SSS, L B OPTIONAL FACTORY INSTALLED DISCONNECT SWITCH AMPS OR

PowerOhm Installation Manual for BM R Series Braking Modules

Asymmetrical Installation Instructions. Components: i2cove Asymmetrical LED Light Fixtures. 12 [305mm] [918mm] 48.

ZoneZ Lite Quick Start Guide

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

Transcription:

User Manual JS-ICON 624 ARCH Dimmer Rack JOHNSON SYSTEMS INC. Spring 2007 2002161

Table of Contents JS-ICON 624 DMX JS-ICON 624 CC 6-2.4kW Dimming Strip JS-ICON 624 ND 6-2.4kW Relay Strip Introduction...3 Characteristics...4 Installation...5 Power Supply Connection Details...7 Dimmer Output...8 Control Input...9 Status LED Indicators...9 System Configuration and Setup...10 Basic JS-ICON Troubleshooting...11 Precision Demultiplexer Printed Circuit Board...12 Phase Reference Printed Circuit Board...13 JS-ICON 624 PACK 6-2.4kW Portable Dimming Pack This manual is accurate at time of printing and subject to revisions and technical updates as required without prior notice. Please visit for applicable updates. JS-ICON 624 ARCH 6-2.4kW Centralized Wall Mount Architectural Dimming Rack 2

Introduction JS-ICON Architectural Dimmers represent performance and longevity at its finest! 16-bit high resolution fades provide smooth light control for the most demanding environment. Suitable for virtually any application where centralized dimmers are required, this rugged hi-density design allows for adjacent side-byside installation where additional dimming capacity is needed. Large power input terminals permit feeder power up to 40 Amps at 120/208 Volt three-phase or 60 Amps at 120/240 Volt single-phase. Premium quality magnetic load breakers permit full loading of each circuit individually. Hinged control section access allows for ease of data and/or analog control termination. Quiet hi-performance chokes and MagLev thermal management technology for superior cooling that is virtually silent. All electronics are easily and remotely monitored with intuitive status LED s. Wireless DMX receiver optional. Six 2400 Watt hi-performance dimmers. Dims standard incandescent, quartz, and low-voltage fixtures. Superior 16-bit fade resolution provides unmatched performance. Both DMX 512 and individual analog control inputs. Optional wireless DMX receiver eliminates control wiring. Status LED s allow easy remote setup and troubleshooting. Magnetic breakers for maximum circuit protection. Over-heat and over-current protected. Non-proprietary dimmer SCR s are 200% rated. MagLev thermal management technology for superior cooling that is virtually silent. Hinged SCR and data section for serviceability. Separate high voltage contractor termination section. 3

Characteristics Power Requirements: 120/208 VAC 3Ø 5 wire up to 40A. Max. rating 14.4kW or 120/240 VAC 1Ø 4 wire up to 60A. Max. rating 14.4kW. Power Termination: Terminal block input and ouput. Environment: Temperature Range: 32 F (0 C) to 104 F (40 C) ambient. Humidity Range: 0% to 90% non-condensing. Dimmer Capacity and Load Type: 6 x 2.4kW standard incandescent, quartz, and dimmable (SCR/Leading-Edge) electronic low-voltage fixtures. Switch Type: 200% rated, non-proprietory SCR solid state relay. Rise Time: 300μs fully epoxy-encapsulated chokes are made from ultra low audible noise core material. Physical: 16.2 H x 12 W x 6 D (41.2cm x 30.5cm x 15.2cm). Weight: Approximately 35 lbs. (16 Kg). Material: 18-guage steel CRS. Finish: Textured white powdercoat. Typical System Installation JS-ICON 624 ARCH - Six (6) CCTS. 4

Installation Mounting The JS-ICON 624 ARCH can be mounted to any wall surface capable of supporting its weight (35 lbs (15.9 kg) for each rack). Four 1/4 (6mm) screws or bolts are required to fasten the rack safely to the wall (see the drawing below for mounting locations and dimensions). To access the mounting locations, remove the contractor wiring access panel, remove the breaker panel, and open the hinged service bay door. For further access to the mounting locations, the hinged service bay door, and left side panel, can be easily removed (see instructions on page 6 for more details). Multiple racks may be mounted horizontally (side by side) with no clearance between them, while vertical mounting requires a minimum of 18 (432mm) of clearance between the racks to allow for adequate separation for ventilation. A minimum of 12 (305mm) of clearance is required for the racks cool air intake and hot air exhaust (see diagram on page 6 for more details). WARNING: Mount the racks only as indicated above. Failure to comply may cause thermal overheating. 12 (305 mm) Hinged Service Bay Door Contractor Wiring Access Panel 13 (330 mm) Breaker Panel Top View Hot Air Exhaust Bottom View Cool Air Intake Power Supply and Load wiring / conduit entry Low-Voltage wiring / conduit entry Left Side Panel mounting screws 5

Installation Removal of the Hinged Service Bay Door The service bay door is hinged for easy access for low voltage wiring hookup of DMX and analog control inputs, as well as service or replacement of the Solid State Relays (SSR). This door may also be removed for additional access for installation mounting. 1. Disconnect the ribbon cable connection from the Precision Demultiplexer PCB. 2. Squeeze the two spring loaded pins together on each of the hinges. 3. Pull the door forward to remove. Removal of the Left Side Panel The left side panel may be removed for service access to the Phase Reference PCB (see page 13 for details) or addition access for installation mounting. 1. Remove the four mounting screws on the top (two) and bottom (two) of the chassis. 2. Disconnect the ribbon cable connection from the PWM Distribution PCB. 3. Disconnect the power supply phase reference wiring connection (J1) from the Phase Reference PCB. 4. Disconnect the fan power connections (J2, J3, and J4) from the Phase Reference PCB. 5. Pull the panel forward to remove. 12 Minimum Clearance for Hot Air Exhaust 18 Minimum Clearance KEEP CLEAR 12 Minimum Clearance for Cool Air Intake 6

Three-Phase Power Supply Input A B C Factory Wiring To Breakers 1-6 #12 AWG Wire Single-Phase Power Supply Input A B C Factory Wiring To Breakers 1-6 #12 AWG Wire Single-Phase Power Supply Input A B C Factory Wiring To Breakers 1-6 #12 AWG Wire Earth Ground Input To Phase Reference PCB #18 AWG Wire Earth Ground Input To Phase Reference PCB #18 AWG Wire Earth Ground Input To Phase Reference PCB #18 AWG Wire Power Supply Connection Details The JS-ICON 624 ARCH is capable of various 120V power supply configurations. Remove the contractor wiring access panel to locate the contractor termination section, where the required power terminals are located. Knockouts on the top and bottom of the chassis are provided for wire/conduit entry to the power terminals. WARNING: Wiring termination must be done by qualified personnel only! Power Supply Configurations - Option 1: Three-Phase with Internal Dimmer/Circuit Breaker Protection 120/208 VAC, 3Ø, 5-Wire up to 40 Amps per phase. Maximum 14.4kW total. Use #2 to #12 AWG copper wire only, rated for 90 C minimum. Torque power connections (A, B, C) to 5.0-5.6 NM (45-50 LB-IN). Torque ground lug connection to 5.6 NM (50 LB-IN). Dimmers 1 and 2 are powered from Phase A. Dimmers 3 and 4 are powered from Phase B. Dimmers 5 and 6 are powered from Phase C. NOTE: Power supply requires an external disconnect. Power Supply Configurations - Option 2: Single-Phase with Internal Dimmer/Circuit Breaker Protection 120/240 VAC, 1Ø, 4-Wire up to 60 Amps per phase. Maximum 14.4kW total. Use #2 to #12 AWG copper wire only, rated for 90 C minimum. Torque power connections (A, C) to 5.0-5.6 NM (45-50 LB-IN). Torque ground lug connection to 5.6 NM (50 LB-IN). Dimmers 1, 2, and 3 are powered from Phase A. Dimmers 4, 5, and 6 are powered from Phase C. NOTE: Power supply requires an external disconnect. Three-Phase to Single-Phase Conversion JS-ICON systems are shipped from the factory ready for three-phase operation unless otherwise specified at the time of purchase. The following steps will need to be followed to convert the JS-ICON from three-phase operation to single-phase operation. 1. Remove wire #3 (red #12AWG wire, marked with black heat-shrink) going from the B power terminal to breaker #3, and reconnect to A power terminal (dimmers 1, 2, and 3 are now connected to Phase A). 2. Remove wire #4 (red #12AWG wire, marked with blue heat-shrink) going from the B power terminal to breaker #4 and reconnect to C power terminal (dimmers 4, 5, and 6 are now connected to Phase C). 3. Reconnect the red #18AWG phase reference wire to the B power terminal. NOTE: Be sure to set the 3-Phase/1-Phase select switch (located on the Phase Reference Printed Circuit Board) to the correct position to ensure proper dimming. 7

Neutral Power Input Power Supply Connection Details Neutral Power Distribution Block Neutral Input: Use 350 kcmil to #6 AWG copper wire only, rated for 90 C minimum. Torque to 31 NM (275 LB-IN). Neutral Output To Load 1-6 To Phase Reference PCB #18 AWG Wire Load Output: Use #4 AWG to #14 AWG copper wire only, rated for 90 C minimum. Torque #4 AWG to #6 AWG wire to 3.95 NM (35 LB-IN). Torque #8 AWG wire to 2.82 NM (25 LB-IN). Torque #10 AWG to #14 AWG wire to 2.26 NM (20 LB-IN). Load Grounding Terminal Use #4 AWG to #14 AWG copper wire only, rated for 90 C minimum. Torque #4 AWG to #6 AWG wire to 3.95 NM (35 LB-IN). Torque #8 AWG wire to 2.82 NM (25 LB-IN). Torque #10 AWG to #14 AWG wire to 2.26 NM (20 LB-IN). Torque two (2) #10 AWG to #14 AWG wires to 2.82 NM (25 LB-IN). Earth Ground Output To Load 1-6 Dimmer Output Six (6) 2400 Watt dimmers (maximum rating 14,400 Watts at 120 VAC). Load (Hot) Output 1-6 JS-ICON 624 ARCH dimmers are designed for high performance dimming of standard incandescent, quartz, and dimmable (SCR/Leading-Edge) electronic low-voltage fixtures. Remove the contractor wiring access panel to locate the contractor termination section, where the required load terminals are located. Knockouts on the top and bottom of the chassis are provided for wire/conduit entry to the load terminals. Load Output Connection Details Load connections are terminated via six (6) tension clamp terminals. Use #8 AWG to #20 AWG copper wire only, rated for 90 C minimum. Strip 0.39 (10mm) of insulation from the end of each load conductor. Pry the tension clamp open by inserting a small flathead screwdriver into the square slot. Insert the load conductor into the tension clamp, and remove the flathead screwdriver. #12 AWG Factory Wiring 8

Control Input The JS-ICON 624 ARCH accepts both DMX 512-A protocol and analog 0-10VDC. These control inputs are configured for HTP (highest takes precedence) operation. DMX Data Input and DMX Data Thru is connected via internal breakaway type connectors. Analog 0-10VDC is connected via internal breakaway type connectors (see diagram on page 12). POWER/DMX IN RF OUT RADIO ID CHANNEL RESET Wireless DMX (WDS) is optional for all JS-ICON Series dimming models. The WDS (Wireless Dimming System) from City Theatrical has been selected for its reliability and ease of use. The WDS Kit - supplied only by Johnson Systems - can be easily adapted to all JS-ICON products. It comes complete with a wiring harness and mounting hardware, and installs quickly. For more information, see the JS-ICON Wireless DMX User Manual. Wireless DMX Option Status LED Indicators POWER = Green ON when the on-board power supply is active, and the microcontroller is running. FLASHES when there is a microcontroller failure. OFF when Phase-A power is off, or a power supply failure occurs. RX = Amber ON when valid DMX signal is being received. FLASHES when invalid DMX signal is received. OFF when no DMX signal is present. CONTROL LEVEL = Blue x 6 (1 per channel) ON when dimmer control is being received via DMX and/or analog. Intensity will increase with the level of control being received. OFF when no dimmer control levels are received via DMX and/or analog. DMX START ADDRESS SELECT SWITCHES Status LED Indicators 9

System Configuration and Setup 1. SETTING THE DMX START ADDRESS Select the desired DMX start address for the JS-ICON via the three rotary DMX START ADDRESS SELECT SWITCHES located on the panel of the rack (as pictured on the previous page). This start address is selectable in single channel increments from 001 through 512. All dimmers within a given JS-ICON will numerically/incrementally follow the selected start address for a total of six channels. Therefore, if the DMX start address is 001, then the JS- ICON s dimmers will be addressed as 001, 002, 003, 004, 005, and 006. 2. CONFIGURE THE MODE SELECT DIP SWITCHES DMX TERM: MODE SELECT DIP SWITCH #1 The MODE SELECT DIP SWITCHES are located internally, on the Precision Demultiplexer Printed Circuit Board (see page 13 for details). To access these switches, simply open the hinged service bay door. Setting this switch to the ON position activates the DMX end-of-line termination. In a DMX network, the device that appears last in the daisy chain of devices is designated as the end of line and must be terminated properly to maintain the integrity of DMX data transmission. It is important that only the end-of-line device is terminated. DMX HOLD: MODE SELECT DIP SWITCH #3 Setting this switch to the ON position activates the DMX Hold feature. With the loss of DMX, the JS-ICON will hold the last DMX data levels received for 2 minutes. Setting this switch to the OFF position disables this feature, and will hold the last DMX data levels received for 2 seconds. DIMMER TEST: MODE SELECT DIP SWITCH #4 Setting this switch to the ON position activates the Dimmer Test feature. This feature enables the selection of one dimmer, or all dimmers, to be turned full on. Selection of the dimmer is via the rotary DMX START ADDRESS X1 switch. Setting the DMX address to 001 through 006 turns the corresponding dimmer output to full. Setting the DMX address to 007 turns all dimmers outputs to full on. Setting this switch to the OFF position will permit normal operation via DMX and/or analog control. CURVE SELECT: MODE SELECT DIP SWITCH #5 AND #6 These two DIP switches allow for modification of the dimmer output curve. Below is a selection chart including the four possible dimmer output curves. DIP SWITCH #5 DIP SWITCH #6 DIMMER CURVE OFF OFF Square Law (Factory Default) OFF ON Direct Drive ON OFF Channel 1 functions as non-dim with a 50% threshold trigger. Channels 2-6 are assigned as Square Law. ON ON All dimmers function as non-dims with a 50% threshold trigger. 10

Basic JS-ICON Troubleshooting Fault/Complaint Status LED Indicators Possible Reason/Fix No output (all circuits). Power LED Off. No power to system. Check main breaker. No output (all circuits). Power LED Flashes. Microcontroller failure. Contact factory. No output (all circuits). Power LED On, RX LED Off. No DMX signal is present. No output (all circuits). Power LED On, RX LED Flashes. Invalid DMX signal is received. No output (all circuits). Power LED On, RX LED On, Control Level LED s Off. Verify correct DMX Start Address is set. Internal hardware failure. Contact factory. No output (all circuits). All LED s On. Dimmer circuit breakers off or tripped. Check breakers. No output (one or more circuits). All LED s On. Dimmer circuit breaker(s) off or tripped. Check breakers. Burnt out lamp(s) or defective fixture. Replace with known good fixture and lamp. Light(s) do not dim, on/off only. Lights on circuits 3 and 4 do not dim, on/off only. Light(s) will not dim out completely. Lights stuck on. Lights off, no control. Lights flickering. Lights flickering. All LED s On. All LED s On. All LED s On. Power LED On, RX LED On, Control Level LED s Off. Power LED On, RX LED On, Control Level LED s On. Power LED On, RX LED On, Control Level LED s On or Off. Power LED On, RX LED On, Control Level LED s flickering between On and Off. JS-ICON configured as a non-dim. Check DIP switch settings. JS-ICON incorrectly wired. Verify contractor wiring and power type (1-phase or 3-phase). Confirm model number power requirement. Contact factory. JS-ICON incorrectly wired. Verify contractor wiring and power type (1-phase or 3-phase). Verify 1-phase/3-phase switch is set for the correct incoming power supply type. Control levels present on DMX. Check DMX. Analog signal present. Remove analog signal source and re-check. Defective SSR. Replace SSR power pack. Dimmer circuit breaker(s) off or tripped. Check breakers. Burnt out lamp(s) or defective fixture. Replace with known good fixture or lamp. Defective SSR. Replace SSR power pack. Defective SSR. Replace SSR power pack. Noise on DMX line. Verify DMX termination is correct for the system. Noise on analog inputs. Disconnect analog inputs and re-check. Defective SSR. Replace SSR power pack. WARNING: Ensure all power is disconnected prior to servicing! All servicing of this product should be performed by authorized personnel only! Unauthorized service may void the warranty! 11

Precision Demultiplexer Printed Circuit Board DMX INPUT/THRU Connection (J11) This internal DMX connection may be used alternatively to the external 5-Pin XLR connectors. It is also the location used for connection of the wireless DMX receiver option. MODE SELECT DIP SWITCHES Provides system configuration options (see page 10 for details). +5VDC and +15VDC Power Supply Output Connection (J8) This connection supplies power for external devices. The +5VDC supply is normally used for powering the wireless DMX receiver option, while the +15VDC supply may be used for other external devices. External devices should not exceed the maximum combined current draw of 200mA. 0-10VDC Analog Inputs with +12VDC Power Supply (J9) This connection is the location to land the 0-10VDC analog inputs. ANA1 through ANA6 controls dimmer 1 through dimmer 6 respectively. This connection also provides a +12VDC power supply normally used for powering external analog devices. External devices should not exceed the maximum combined current draw of 200mA. 12

Phase Reference Printed Circuit Board 3-Phase/1-Phase Select Switch (SW1) This switch enables selection of 3-Phase or 1-Phase operation of the JS- ICON. If this switch is not in the correct position, dimmers 3 and 4 will not dim correctly and appear as though they are non-dim. Refer to 3-Phase to 1-Phase conversion directions on page 6 for more details. DC Power Supply Fuse (F1) This fuse protects the on-board switch mode DC power supply from overcurrent. If the POWER LED is not illuminating, and AC power is present on phase A, check the fuse by removing the fuse holder cap and inspecting, or measure continuity. If the fuse needs to be replaced, only use a fuse rated the same as the original GDC 250mA 250V fuse. 13

Notes 14

Notes 15

User Manual JS-ICON Series Dimmers Spring 2007