ARC GPM MAX WARNING BEFORE BEGINNING INSTALLATION OF THIS APSCO PRODUCT READ AND FOLLOW ALL INSTALLATION INSTRUCTIONS

Similar documents
PNEUMATICS CONTENTS HST-TAMPER

Duramax Lift Pump Kit 9-11 PSI Installation Instructions P/N# D

MODEL SS675 TRANSPORT HYDRAULIC COOLING SYSTEM

TRANSPORT HYDRAULIC COOLING SYSTEM

Page 1 of 17. Part# M0200 Rev.11 7/29/2016

Rugby Manufacturing Direct Mount Unit Manual

Installation Notes for Ingersoll Rand KVG-123 Compressor Package (Up to 255 Gallon Sump Capacity) Ingersoll Rand KVG-123 Compressor Package

Fits AGCO, Challenger, & Massey Ferguson Tractor Models:

Automated Steering Hydraulic Installation Kit

Installation & Operator s Manual

Kit. Hydraulic Kit Installation Guide REV B Table 1 Component List. Item Component Part Number Qty

Arctic Equipment Manufacturing Corporation R04 M673F Power Unit Kit Installation Instructions. M673F installation instructions

Kysor On/Off Rear Air Fan Drive

Installation & Operator s Manual

SHOP PRO FXP 95 UPGRADE KIT (REGULATED)

Automated Steering Hydraulic Installation Kit

CRYSTEEL S HOIST. this manual must be included with the vehicle after completing the installation.

Kysor Rear Air Fan Drives

INSTALLATION INSTRUCTIONS

MOBILE HYDRAULIC COOLING SYSTEMS MODELS AVAILABLE IN BOTH VERSIONS

GH-BETTIS SERVICE INSTRUCTIONS DISASSEMBLY & REASSEMBLY FOR MODELS HD521-M4, HD721-M4 AND HD731-M4 DOUBLE ACTING SERIES PNEUMATIC ACTUATORS

STEERING 19-1 STEERING CONTENTS

16K HYDRAULIC PLANETARY CAPSTAN DRIVE

Please read all instructions before operation!!

January Rev. B Rel. 2

Installation & Operator s Manual

Low Profile J Series Power Unit with Vane Pump

Oregon Fuel Injection

REMOVAL & INSTALLATION

1996 Aerostar/Ranger/Explorer

MID RISE. INSTALLATION and OPERATION MANUAL MODEL 6000A // 6000E 6,000 LB. CAPACITY. READ and SAVE THIS INSTRUCTION MANUAL

MicroCoat System Operating Manual MC4000 Series MC785M, MC785M-WF Spray Valves

Kit. Hydraulic Kit Installation Guide REV A. Item Component Part Number Qty

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

RUFNEK 80 DESIGN SERIES 001 SERVICE MANUAL INTRODUCTION AND THEORY OF OPERATION...2 ASSEMBLY NUMBER EXPLANATION...2 WINCH MODEL CODES...

HYDRAULICS. TX420 & & lower. Hydraulic Tandem Pump Removal. 4. Remove the LH side panel (Fig. 0388).

TURBO KIT INSTRUCTIONS

TC Series Cooling Systems

DISCONTINUED. Installation. Aerada 900 Series Futura Faucet. With Accu-Zone (AZ) Infrared Control

TOYOTA TUNDRA 3 BODY LIFT INSTALLATION INSTRUCTIONS 2014 KIT# 5643

Tailgates By THIEMAN FOR MODELS LST20, 25, 30 OWNERS MANUAL/PARTS LIST

Kysor On/Off Rear Air Fan Drive

OWNERS MANUAL/PARTS LIST

Post Driver Attachment

Copper Sleeve, Unit Injector, Replacement

MicroCoat. System Operating Manual MC2000 Series. MC785, MC785-WF Spray Valves. US: UK: Mexico:

General Information. Assembly Instructions B L R F. 3000TM Fold Assist Kit

4. Remove the bed bolts A.) Using a 1/2 socket, remove the four inner bed bolts. B.) Using a T-25 Torx driver, remove the four outer bed bolts.

Installation Instructions Capacity 10,000 lbs. DP10 (200 Series Lift)

WCI-20 Power-Pak Coldwork Hydraulic Power Supply Rev B

INSTALLATION & OWNER S MANUAL

3.1 DISPENSER BLACK SHADOW SERIES. Tools Needed for Mounting SCS Dispenser Hammer

FULL BORE PERFORMANCE EXHAUST MANIFOLDS F-150 ECOBOOST 3.5L

SERIES-1 SERIES-1.5 SERIES-2 AEC GROUP 3600 WEST CARRIAGE DRIVE SANTA ANA CA

MIDRISE MODEL SM60F_1 // SM60F_A 6,500 LB. CAPACITY

INSTALLATION & OWNER S MANUAL

RELEASING PRESSURE IN THE HYDRAULIC SYSTEM,

Automated Steering Hydraulic Installation Kit

INSTALLATION AND PARTS MANUAL

TOYOTA TRUCKS / SUVs COLD AIR INTAKE Section I Installation Preparation. 4.0L V6 (1GR-FE) Part Number(s): PTR

Model 5-025, 5-050, &

Eclipse GEN 2.0 CAFSystem, Model 150-ECL CAFS PTO Kit Installation Instructions

Air Oil Separator for WRX

Troubleshooting The Transmission Hydraulic System

MARATHON TELESCOPIC HOIST

Installation Instructions Capacity 10,000 lbs. (100 Series Lift)

Atlas PV-9WP Addendum

If there is additional labor or other costs above the 4 hrs labor you must call VMAC for approved coverage

OWNERS MANUAL. GMC C K AND 19K GVW CHASSIS CAB 2004-NEWER MODELS (Link Part No. 8M000050) PROUDLY INSTALLED BY : COMPANY : INSTALLER SIGNATURE :

WA 2719 ( 604 ) ( 604 ) , H.E.R.O.

C40008 & C40009 EXHAUST BRAKES

Read this entire manual before operation begins.

Installation Manual. Model T675A Engine Brakes. For Mack 6 Cylinder, 2 valve Head ENDT-673, 675, 676 & E6 Series Engines.

Installation Manual v1.0: The Torque Pro Propane Injection System GM. Please read all instructions before installation.

INSTALLATION & OWNER S MANUAL

Illustrated Parts List for VMAC System V90G136 Ram Cab & Chassis with PTO PREP 6.7L Cummins Diesel

DISPLACEMENT PUMP INSTRUCTIONS-PARTS LIST Rev. K. Model , Series A Model , Series B Model , Series A

Martin Tornado Retrofit Valve

MP18 Stacking Valve System Technical Information Manual

Read this entire manual before operation begins.

TOYOTA 4RUNNER COLD AIR INTAKE FJ CRUISER Preparation

GPS AutoSteer System Installation Manual

THE TRACTOR AND/OR LOADER (IF EQUIPPED)

Eclipse GEN 2.0 CAFSystem, Model 150-ESECL as used with TC20 Series PTO Installation Instructions

TOYOTA FJ CRUISER / 4RUNNER COLD AIR INTAKE Section I Installation Preparation. 4.0L V6 (1GR) Roller Rocker Part Number(s): PTR

BA440 PISTON. Hydraulic Air Compressor

Reverse Osmosis System

CONTENTS. Product Features and Specifications...1. Installation Requirement Steps of Installation.. 5. Exploded View Test Run...

Typical Install Instructions

Telescopic Transmission Jacks

PRODUCT SAFETY NOTICE

M16, 20, 25, 30 MLB16, 20, 25, 30 OWNERS MANUAL/PARTS LIST

CIRCLE SEAL CONTROLS

Troubleshooting the Transmission Hydraulic System

INSTALLATION INSTRUCTIONS

Installation Instructions

CHEVY AVALANCHE 1/2-TON ONLY 3 BODY LIFT KIT INSTALLATION INSTRUCTIONS KIT# 10173

SYSTEM SAVER 318 AIR COMPRESSOR FOR MACK E-TECH AND ASET ENGINES MAINTENANCE MANUAL

HOW - TO EMISSION CONTROL BASICS EMISSION CONTROL BASICS

Ford 6.0L Powerstoke Regulated Fuel Return

Transcription:

ARC-30 30 GPM MAX WARNING BEFORE BEGINNING INSTALLATION OF THIS APSCO PRODUCT READ AND FOLLOW ALL INSTALLATION INSTRUCTIONS REV1 10-18 INSTALLATION & OWNERS MANUAL

Index Page: Page 3 - Features Included Page 4 - Figure 1: ARC-30 Dimensions Page 5 - Installation & Operation Page 6 - Figure 2: Typical Installation Examples Page 7 - Figure 3: ARC-30 External Shell Exploded View Accessories Page 8 - Figure 4: ARC-30 Internal Components Exploded View Page 9 - Table 1: Parts List Page 10 - Table 2: Accessories Page 10 - ARC-30 Repair Page 11 - Table 4: Trouble Shooting Guide Page 12 - Figure 5: ARC-30 Repair Page 13 - Figure 6: Drill Dimensions WARRANTY All APSCO, Inc. products are warrantied for 1 year of service, but in no case more than 2 years beyond the original date of purchase. APSCO warrants the product as free from defects in materials and workmanship under normal recommended use. In order to consistently bring you the highest quality, full-featured products, we reserve the right to change our specification and designs at any time. APSCO products and logo are the trademark of APSCO. This document, including textual matter and illustrations, is copyright protected by APSCO, with all rights reserved. +1 (918) 622.5600 email: sales@apscopower.com 8178 E. 44th Street, Tulsa, OK 74145 APSCOPOWER.COM

FEATURES INCLUDE: Stainless Steel Construction The basic size of our cooler is 20 X20 X8, making it the most compact cooler in its class. 4 Gallon Hydraulic Reservoir Weight: 100 lbs dry, making it the lightest hydraulic cooler in its class Flow Rate to 30gpm Pressure rated to 3000 psi Heat rejection is 20HP at 30gpm with 80 F ETD. This is the highest heat rejection in its class Hydraulic filter This filters your return fluid with a ten micron filter, has an integral bypass valve, and conveniently filters the oil that is added to the reservoir. Filter Element = 10 micron Filter Bypass valve- Set at 25 psi. This feature protects the filter from over pressurization due to cold oil or a blocked element. System Cold Oil Bypass Valve Set at 60psi. This feature ensures that the low pressure side of the hydraulic system stays at a low pressure. Primarily protects from over pressurization due to cold oil. System relief valve This Feature ensures that the maximum system pressure does not go any higher than what you set the valve at. Factory set at 3000psi and is adjustable from 500psi to 3000psi. Flow control valve This feature ensures the delivery of consistent flow to the hydraulically powered cooling blower motor. It is factory set to ensure the most efficient blower speed. Page 3

FIGURE 1: ARC-30 Dimensions MOUNTING STUD 1/2-20 (x4) HYDRAULIC FILTER 7.81 SIGHT LEVEL 2.03in 5.50 5.00 19.48 AIR INLET 20.29 GAUGE PORT -4 SAE RETURN PORT -20 SAE MAGNETIC DRAIN PLUG -8 SAE SUCTION -24 SAE PRESSURE PORT -16 SAE CASE DRAIN -8 SAE Page 4

INSTALLATION & OPERATION Warning: High Pressure oil can cause severe injury. Turn off PTO and bleed pressure before servicing hydraulic system. Warning: heavy object. To avoid muscle strain or back injury, use lifting aids and proper lifting technique when removing or replacing. Warning: Rotating Fan Blade. Can cause serious injury or cut. Keep hands clear. Turn off and lockout unit before servicing. Caution: Surface May be Hot. Ensure PTO is off and unit has cooled before servicing. POSITIONING AND MOUNTING: The ARC-30 is designed to fit in very tight spaces, its narrow profile allows for behind the cab or frame rail mounting. Unit will ship with a mounting template to aid in proper installation. (See FIG. 6) The ARC-30 requires at least 1.5 air gap on the fan shroud side to allow for adequate air intake. CONNECTIONS (SEE FIG.2): Note: SAE ports do not require a thread sealant, they seal with an o-ring. Make sure your SAE fittings have a properly sized o-ring and are free of thread sealant. Suction Port-24 SAE Your hose will go from this port to the pump inlet port. Minimum hose size 1.5. Pressure Port -16 SAE The hose from your pump output will T into this port. One side of the T supplies the 1.2gpm to the hydraulic fan. Flow will only be greater than 1.2gpm through this line is if the pressure relief valve setting is exceeded. The other side of the T runs to the motor input or control valve input depending on your system. Minimum hose size 1. Case Drain -8 SAE Some hydraulic pumps, motors, and control valves have a case drain line that needs to be plumbed directly back to the cooler reservoir. This is where you will make that connection. If your hydraulic system does not require a case drain line simply leave the APSCO provided hex plug in this port. Return Port -20 SAE The hose from the outlet of your motor or control valve should be plumbed into this port. This port takes all of the return flow from your motor and sends it through the filter and heat exchanger built into the ARC-30. Minimum hose size 1.25. Gauge Port -4 SAE This is a test port on the bottom of your cooler. This port is connected to the input port of the manifold, for the purpose of connecting diagnostic equipment like a gauge or transducer to system pressure. Magnetic Drain Plug -8 SAE This is where you will drain the cooler reservoir to change the hydraulic fluid. START UP PROCEDURE: This Unit comes ready to install, no assembly required. Make up all hydraulic connections. Remove Filter cap from top of cooler, leave filter in place and add fluid until it reaches middle of the sight glass with the PTO disengaged. This will filter the fluid as it is being added. Even new hydraulic fluid should be filtered. You will need to add hydraulic fluid in slowly because the filter is in place. Bleed air from lines and check fluid level again. Ensure that the lines are full of fluid and the air is bled from your system, some pumps and motors, particularly piston will be ruined in a matter of seconds if operated without fluid. Depending on the length and diameter of the system hoses you may need to add fluid to the reservoir several times. Install filter cap. Slowly engage PTO with engine at idle speed. Check for hydraulic leaks and repair as needed Check for fan operation. Note that the fan will turn slowly when system pressure is low. Recheck reservoir fluid level. Each time you add fluid disengage PTO, if the reservoir gets completely empty before you add fluid you will need to bleed air from the lines again. Pressure relief valve setting The ARC-30 pressure relief valve is factory set to 3000psi. This is a good setting if all of your other system components are rated to at least 3000psi. Failure to set the relief valve 200psi higher than system pressure or any other system relief valve will result in excess build up of heat. If you need to adjust the APSCO pressure relief valve it can be accessed by removing the cooler side cover and manually adjusting with an Allen wrench. The change in pressure is roughly 150psi/ quarter turn. Any time the side cover is off the PTO should be off as well. Once you verify system functionality with no leaks and the proper fluid level your ARC-30 is ready for operation. SYSTEM MAINTENANCE: Filter Unscrew filter cap (use a screw driver or tool with a square shank) and replace element every three months. ROTATE CLOCKWISE TO INCREASE PRESSURE RELIEF SETTING (INTERNAL HEX) 9/16 JAM NUT. LOOSEN T0 ADJUST. TIGHTEN WHEN PROPER RELIEF PRESSURE HAS BEEN ACHIEVED PRESSURE RELIEF VALVE. FACTORY SET AT 3000PSI Fluid Check fluid level daily (with the PTO off the fluid level should reach the middle of the sight glass). Drain and replace hydraulic oil every 6 to 12 months depending on use. Recommended Fluid Use non foaming hydraulic fluid and see Pump and Motor Manufacturer recommendations. Clean Radiator Use a mild cleaner compatible with aluminum. Be careful not to damage fins if using a power washer to rinse cleaner off of radiator. Visually inspect daily and clean if necessary. Page 5

ARC-30 WITH DIRECTIONAL CONTROL VALVE FIGURE 2: Typical Installation Examples Air Discharge Air Inlet Suction Directional Control Valve Optional Accessories (Table 2) Hydraulic Motor Optional Accessories (Table 2) Tee Processing Pump Hydraulic Pump Pressure Return ARC-30 WITHOUT DIRECTIONAL CONTROL VALVE Air Inlet ARC-30 Air Discharge Compressor Suction Tee Hydraulic Motor Page 6 Hydraulic Pump Pressure Return

FIGURE 3: ARC-30 External Shell Exploded View Page 7

FIGURE 4: ARC-30 Internal Components Exploded View Page 8

TABLE 1: Parts List ITEM NO. PART NUMBER DESCRIPTION QTY. TORQUE VALUE REQUIRED TOOL 1 7596 SHEETMETAL CASE RIGHT 1 2 7598 SHEETMETAL CASE BOTTOM/BACK 1 3 7597 SHEETMETAL CASE LEFT 1 4 7599 CASE, TOP 1 5 7601 SHEETMETAL CASE FRONT 1 6 7630 INLET RING FOR 225MM IMPELLER 1 7 7631 FINGERGUARD 1 8 7812 WHEEL STUD 1/2-20 4 9 7713 18-8 SS FLAT WASHER 4 10 7715 1/2" LOCK WASHER SS 4 11 7714 1/2-20 NYLON LOCK NUT 4 100 FT. LB 3/4 DEEPWELL SOCKET 12 3786 NUT 1/4-20 NC SS HEX NYLOCK 8 10 FT. LB 7/16 END WRENCH 13 4914 CAPS 10-32 X 1/4 BH SS 1 21 IN. LB 1/8 ALLEN 14 7709 1/4-20 X 5/8" ZINC TORX T27 BUTTON HD 35 10 FT. LB T27 TORX 15 7860 WASHER, RUBBER.5ID X 2.25OD 4 16 7593 MANIFOLD 1 17 7657 SYSTEM RELIEF PILOT OPERATED 1 35 FT. LB 7/8 END WRENCH 18 7664 STRAIGHT THREAD SWIVEL CONNECTOR 1 115 FT. LB 1 7/8 END WRENCH 19 7656 FLOW REGULATOR 8-2 CAVITY 1 25 FT.LB 1 5/16 END WRENCH 20 7726-08 SAE PLUG 2 40 FT. LB 5/16 ALLEN 21 7644-04 SAE PLUG 3 13 FT. LB 3/16 ALLEN 22 7594 ADAPTER, MANIFOLD 1 23 7626 HUB, PRESS FIT 1 24 7642 FAN 225MM 1 25 7653 SHCS 3/8"-16 SS 1" LG 3 23 FT. LB 5/16 ALLEN 26 7654 MOTOR MANIFOLD SHCS 5/16"-18 4 13 FT. LB 1/4 ALLEN 27 1195 O-RING 2-013 9/16 OD 7/16 ID 4 28 7643 SHCS 8-32 1/2" LG 2 12.6 IN. LB 9/64 ALLEN 29 7592 TANK ASSEMBLY 1 30 7833 HEAT EXCHANGER ASSEMBLY 1 31 7655 COLD START RELIEF VALVE (CHECK) 1 115 FT. LB 1 1/2 DEEP WELL SOCKET 32 7646 12FJ-08MJ STRAIGHT LARGE HEX 1 40 FT. LB 1 1/4 DEEP WELL SOCKET 33 7650 BSPP LOCKNUT (FOR USE WITH SIGHTGLASS) 1 35 FT. LB 1 5/8 SOCKET 34 7660 SIGHT LEVEL PLUG 1" BSPP 1 35 FT. LB 1 1/2 SOCKET 35 6827 HYDRAULIC FILTER ASSEMBLY 1 36 7602 CLEANOUT COVER, TANK 1 37 7662 O-RING 0-258 6 1/4"OD 6"ID(CLEAN OUT COVER) 1 38 7748 O-RING 2-011 IL 7/16OD 5/16ID 8 39 7709 1/4-20 X 5/8" ZINC TORX T27 BUTTON HD 10 10 FT. LB T27 TORX 40 7711 3/8-16 X 1 1/2 SHCS BOLT 18-8 2 20 FT. LB 5/16 ALLEN 41 7710 3/8-16 X 1 1/2" LOCK NUT 18-8 2 10 FT. LB 9/16 END WRENCH 42 7647 16MFS-16MAORB 45 ELB FORG 1 115 FT. LB 1 5/8 & 1 1/2 END WRENCH 43 7648 1" ORFS TUBE NUT 1 115 FT. LB 1 5/8 END WRENCH 44 2574 O-RING 2-220 1 5/8 OD 1 3/8 ID 1 45 1733 O-RING 2-212 1 1/8 OD 7/8 ID 1 46 7815 BARB FTG, SLV END 1 47 7816 BARB FTG, MALE 1-5/16"-12UN 1 115 FT. LB 1 1/2 END WRENCH 48 7817 HOSE, HYD, 1" ID 1 49 7821 BRACKET, TANK MOUNT 1 50 7841 HH 1/4-20 X 2" CAP SCREW 2 10 FT. LB 7/16 END WRENCH 51 4624 O-RING 2-025 1 5/16 OD 1 3/16 1 52 7842 SEALING WASHER, COPPER 2 53 7845 PLUG, #08 SAE MAGNETIC 1 40 FT. LB 5/16 ALLEN 54 7862 O-RING, 2-916 SAE 16 ORB 1 55 7641 HYDRAULIC MOTOR, CW ROTATION 1 Page 9

TABLE 2: Accessories ITEM NO. PART NUMBER DESCRIPTION QTY. TORQUE VALUE REQUIRED TOOL 56 7855 FILTER ELEMENT, ARC 30 1 SQUARE SHANK SCREWDRIVER 57 7861 CAVITY PLUG, (FOR RELIEF VALVE) 1 115 FT. LB 7/8 END WRENCH PRESSURE PORT 58 7868 16MJ-16MORB-16MJ RUN TEE 1 115 FT. LB 7/8 END WRENCH 59 7869 16MORB-16MJ STRAIGHT 1 115 FT. LB 1 1/2" END WRENCH 60 7870 16MORB-16MJ 90 1 115 FT. LB 1 1/2" END WRENCH 61 7893 16MORB-16FP STRAIGHT ADAPTER 1 115 FT. LB 1 1/2" END WRENCH 62 7894 16MP-16MP-16MP TEE 1 115 FT. LB 7/8" END WRENCH RETURN PORT 63 7871 20MORB-20MJ STRAIGHT 1 115 FT. LB 1 7/8 END WRENCH 61 7872 20MORB-20MJ 90 1 115 FT. LB 1 7/8 END WRENCH 65 7895 20MORB-20FP STRAIGHT ADAPTER 1 115 FT. LB 1 7/8 END WRENCH 66 7896 20MP-20MP 90 115 FT. LB 1 7/8 END WRENCH SUCTION PORT 67 7874 1.5" HOSEBARB - 24ORB STRAIGHT 1 115 FT. LB 2 1/8" END WRENCH 68 7875 2"HOSEBARB - 24ORB 90 1 115 FT. LB 2 1/8" END WRENCH 69 7876 1.5" HOSEBARB - 24ORB 90 1 115 FT. LB 2 1/8" END WRENCH 70 7897 24MORB-24MJ 90 1 115 FT. LB 2 1/8" END WRENCH 71 7898 24MORB-32MJ 90 1 115 FT. LB 2 1/8" END WRENCH 72 7899 24MP-24MP 90 1 115 FT. LB 2 1/8" END WRENCH 73 7900 24MORB-24FP STRAIGHT ADAPTER 1 115 FT. LB 2 1/8" END WRENCH 74 7901 24MORB-32FP STRAIGHT ADAPTER 1 115 FT. LB 2 3/4" END WRENCH 75 7902 32MP-32MP 90 1 115 FT. LB 2 3/4" END WRENCH 76 7903 24MORB-24MP 90 1 115 FT. LB 2 1/8" END WRENCH CASE DRAIN PORT 77 7877 08MORB-08MJ STRAIGHT 1 40 FT. LB 7/8 END WRENCH 78 7878 08MORB-08MJ 90 1 40 FT. LB 7/8 END WRENCH 79 7904 08MORB-08FP STRAIGHT 1 40 FT. LB 7/8 END WRENCH 80 7905 08MORB-08MP 90 1 40 FT. LB 7/8 END WRENCH 81 7906 08MP-08MP 90 1 40 FT. LB 7/8 END WRENCH GAUGE PORT 82 7879 04MORB-1/4"FP STRAIGHT 1 15 FT. LB 3/4" END WRENCH HYDRAULIC DIRECTION CONTROL VALVE OPTIONS ARC-30 STD Direction Valve Air Assembly Number 20-UNI-1S-03 ARC-30 STD Direction Valve Manual Assembly Number 20-UNI-1S-04 M=MALE, F=FEMALE, P=PIPE OR NPT THREAD, J=JIC 37 FLARE, ORB=O-RING BOSS FITTINGS ARE SIZED IN 16TH" INCREMENTS SO 16=16/16THS OR 1", 8=8/16" OR 1/2", 24=24/16THS OR 1.5" ARC-30 REPAIR: The design of the Arc-30 will allow you to remove three of the body panels and pull the internal assembly while leaving the right side assembly panel mounted to truck (refer to FIG 5, TABLE 3 below). This is assuming you have left enough room around the heat exchanger to get to the body panel fasteners. Drain hydraulic fluid from unit by removing the magnetic drain plug (Item 53, FIG.4), once all the fluid has been drained replace and torque accordingly. Do not re-use this fluid. Remove all connections to the ARC30, these connections will be wet so be sure to have a catch pan for the fluid that will be spilled. Cap and plug all hoses and ports to prevent contamination. Remove the front (Item 3) and top case (Item 4), as well as the left side cover (Item 2). You will also need to remove the three bolts (Item 5) that fasten the right side case to the manifold. These are located on the bottom of the Arc-30. You can now remove the entire inner assembly leaving the right side panel still mounted to the truck. It is recommended to do any repair work on a clean surface in a dust free environment. Once the Arc-30 is out of its case you will be able to remove and replace any of the components. If the repair requires you to remove the tank mount bracket (Item 49) mark the position of the bolts on the bracket so you can reinstall in the same position. This will help ensure that your sight glass and tank cap will fit concentrically within the case when you put the Arc-30 back together. When re-assembling the Arc-30 be sure to use blue loc-tite on all fasteners and torque according to TABLE 1. Page 10

TABLE 3 ITEM NO. PART NUMBER DESCRIPTION QTY. 1 7724 SIDE PANEL ASSEMBLY, RIGHT 1 2 7723 SIDE PANEL ASSEMBLY, LEFT 1 3 7601 SHEETMETAL CASE FRONT 1 4 7599 CASE, TOP 1 5 7709 1/4-20 X 5/8 ZINC TORX T27 BUTTON HD 22 TABLE 4: TROUBLE SHOOTING GUIDE Problem Cause Corrective Action Fan not spinning Low system pressure Low oil level in tank Air leak in suction hose or fitting connections Pinch Bolts (Item 29) are loose or missing Collapsed Suction Hose Flow Control Valve (Item 19) has blocked orifice Fan sucked in road trash such as a plastic bag and has caused fan to be in a bind The system pressure must be higher than 900 psi for the fan to spin at full speed. Slower fan speeds in an unloaded condition are part of normal operation Fill Tank, tighten fittings, and bleed air from lines Tighten fittings and bleed air from lines Replace and re-torque Replace suction hose Remove and clean or replace valve. Change fluid and filter element With Unit de-energized, remove debris, check for proper torque of pinch bolts. Check to make sure the fan is not broken or cracked and motor functions properly High Oil Temperature Dirty Heat Exchanger Assembly (Item 31) System Relief Valve (Item 17) is opening low oil level in tank Collapsed Suction Hose Air leak in suction hose or fitting connections Clean Heat Exchanger. Use mild cleaner compatible with aluminum. Be careful not to damage fins when using a pressure washer. Ensure that valve relief pressure is set higher than your system pressure. Remove and clean or replace valve. Change fluid and filter element Fill Tank and tighten fittings Replace suction hose Bleed air and tighten fittings Aeration of oil (Milky looking oil) Water Contamination Air leak in suction hose or fitting connections Pump is not lower than the tank Restricted suction line low oil level in tank Replace Fluid and Filter Element. Check all fittings and Filter Cap for tightness Tighten fittings and bleed air from lines Reposition to ensure the fluid can gravity feed into the pump through the suction line. Route suction line to make as straight and short of a run as possible. Ideally you would want a 1.5 suction line for minimum flow restriction. Fill Tank and tighten fittings, verify proper fill level before use Heat exchanger Assembly leaks Loose Fittings (Items 48 &18) or cut o-rings (Items 55 & 52) Burst Heat Exchanger Replace o-rings and tighten fittings Replace Cold start relief valve (Item 32) and Heat exchanger assembly (Item 31) Page 11

FIGURE 5: ARC-30 Repair Page 12

DRILL DIMENSIONS (NOT TO SCALE) Top of Cooler FIGURE 6 1.41 5.00 2.69 Edge of Cooler Allow 1.5" minimum clearance from inlet 5.50 Minimum 5/8 diameter holes for studs 7.81 Page 13

(918) 622.5600 email: sales@apscopower.com 8178 E. 44th Street, Tulsa, OK 74145 APSCOPOWER.COM