Spun Bay Installation Standard Version (non dimmable), Hook Mount

Similar documents
MOONRING 1.5 MOONRING 3

Albeo TM LED Luminaire Heavy Industrial High Bay Lighting (ABR1-Series)

INSTALLATION INSTRUCTIONS LIGHTPLANE 3.5. LP3.5 Suspended LED. A nd Avenue, Unit 1. CA P E W alwusa.

INSTALLATION INSTRUCTIONS MOONRING 1 LP1/MR1

INSTALLATION INSTRUCTION Aether 2 Shallow Recessed Housing

INSTALLATION INSTRUCTION Aether 3.5 Color Tunable LED Downlight

I. Pendant Mount Installation

INSTALLATION INSTRUCTIONS SUPERPLANE 2.5. Suspended. A nd Avenue, Unit 1 Oakland, CA P E W alwusa.

Lumination TM LED Luminaire RC/LRC/RX/LRX Series - New Construction Frame

INSTALLATION INSTRUCTIONS LED RETROFIT ASSEMBLY (LRA) Rev F

INSTALLATION INSTRUCTION Bollard Light 12V

LED IMPORTANT SAFETY INSTRUCTIONS

MODELS 2 & 4 Top Conduit Linears

MAXLITE RKT LED Retrofit Kit

LUNERA VERTICAL E26 LED FLOODLIGHT LED Replacement for E26 Medium Base Floodlights Type B Ballast Bypassed

Record Plus. Molded Case Circuit Breaker Accessories. Plug In Base. DEH40915 Installation Instructions

INSTALLATION INSTRUCTION Oculux 3.5" Architectural Downlight R3CRN-11, R3CSN-11

HBDBM High Bay Series

MODELS. 2 & 4 Low Profile Linears

INSTALLATION INSTRUCTION Vanities & Wall Sconce WS-85618

High Bay Luminaire Series

WARNING/AVERTISSEMENT. Coupez l alimentation électrique à la boîte de fusibles ou au disjoncteur avant servicing or installing product.

Specification Grade Contemporary Wall Mount/Technical Installation Data

MODELS SafeSite LED Linear, Class I Div V, 2 & 4 Versions

Tetra minimax. LED Lighting System. BEFORE YOU BEGIN Read these instructions completely and carefully. Installation Guide

INSTALLATION INSTRUCTION Bliss - Vanities & Wall Sconces WS-79622

GETTING STARTED WITH IN-WALL DIMMER SWITCH

LS1 SERIES IMPORTANT: READ ALL INSTRUCTIONS THOROUGHLY AND CAREFULLY PRIOR TO INSTALLATION OF LINEAR SERIES FIXTURES AND RETAIN FOR FUTURE REFERENCE.

READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. DANGER RISK OF SHOCK DISCONNECT POWER BEFORE INSTALLATION

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTION Magnetic Transformer

Verax 75 and Verax VPA Installation Manual

Lumination TM LED Luminaires Suspended LED Fixture (Series EP14)

Lumination TM LED Luminaires LAL Series - Continuous Run Option

LED IMPORTANT SAFETY INSTRUCTIONS

LAL SERIES LED LUMINAIRE

Have a Bright Day! Nicholas Harmon President, Verilux, Inc.

INSTALLATION INSTRUCTION

100A 225A 400A PATENT PENDING

INSTALLATION INSTRUCTIONS

IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following:

Lumination TM LED Luminaire (IS Series)

INSTALLATION INSTRUCTIONS LED Canopy Retrofit Kit

CSD Series Current Devices Split Core

Installation Instructions: Eco Linear High Bay

Operating Instructions

Wet Rated Batten LED Luminaire

The only lighting product that is designed, approved, and patented to replace the cross members in a suspended grid ceiling system.

Operation/Installation Instructions

Captivate Illuminated Mirror Light

System 350 S350C Temperature Slave Stage Module

2-WAY REMOTE STARTING SYSTEM WITH 1 BUTTONS FOR AUTOMATIC TRANSMISSION RED301-2WAY / ANT-2WDSS. User Guide For Key

HBC-20 - LED HIGH BAY

Installation Instructions

ELV1abbccd-e. Color Temperature: 30 = 3000K White 35 = 3500K White 40 = 4000K White 45 = 4500K White 50 = 5000K White

CES MOUNT SMS MOUNT EAS MOUNT PNS MOUNT LOUVER OPTION 2700K 3000K 3500K 4000K STATIC GREEN STATIC RED STATIC AMBER WHITE (4000K) - 48" FIXTURE

Power Break II Circuit Breaker Accessories Motor Operator Mechanism

Otterb. bo Inc. Giant. Manual PN: Rev 01

IMMERSION. imagination at work. Retrofit Installation Guide. GE Lighting. LED Refrigerated Display Lighting

Fan Relay Board (FRBii) Assembly

UB-2 2 Universal Button

Cable Cubby 1202 and 1402 Installation Guide

TM-11x1 Series Room Temperature Module

New dimming drivers are compatible with most wall dimmers for % light control. For non-dimming

INSTALLATION INSTRUCTIONS

CES MOUNT SMS MOUNT EAS MOUNT PNS MOUNT LOUVER OPTION 2700K 3000K 3500K 4000K STATIC GREEN STATIC RED STATIC AMBER WHITE (4000K) - 48" FIXTURE

OWNER S MANUAL OM F

Operating Instructions

RAPID SHUTDOWN COMBINER

m WARNING! READ m BEFORE INSTALLATION

WARNING / AVERTISSEMENT

Mobile Crane/Grue mobile LTM

OSQ Series IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. LED Area Light TO INSTALL:

Installation Instructions for SINGLE COLOR 24V LINEAR LED NEON

The installation must only be performed by a licensed electrician. Disconnect power before installing the product or servicing it.

M9109-GGx-5 Series Proportional Electric Non-spring Return Actuators

EMERY SKY SUSPENDED LED LUMINAIRE

97Ti, 95Ti, 93T Treadmills Assembly Instructions

VA9905 Actuator and VG1600 Series Six-Way Valves

Energy Solutions LED Accelerator Program

Luminaires - LED High Bay

Installation Instructions

Retractor SM Installation Guide

AEROBAY INSTALLATION INSTRUCTIONS

M9109-GGx-4 Series Proportional Electric Non-Spring Return Actuators

M9106-GGx-4 Series Proportional Electric Non-Spring Return Actuators

ECO L HIGH BAY.

HIGHBAY RAIL 400W INSTALLATION INSTRUCTIONS

ULTRA PERFORMANCE LED TUBE INSTALLATION INSTRUCTIONS

L1EPH ECONO LED HIGH BAY LUMINAIRE FEATURES AND SPECIFICATIONS MOUNTING OPTIONS & ACCESSORIES OVERVIEW

* ALTERNATIVE ASSEMBLY * ENSEMBLAGE ALTERNATIVE

FOR USE WITH MODEL NUMBERS:

M Remote Mounting Kit

'63 CHEVY IMPALA SS 2 'N 1

BOLT 3544 ANATOMY BOLT SPECIFICATIONS LIGHT SOURCE MODULE MODULE LUMENS PER FOOT DELIVERED LUMENS FIXTURE WATTAGE 40.3W 40.

OmniAire Omnitec Design, Manufacturing Air Purification Equipment Since 1988

INSTALLATION DATA ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

INSTALLATION DATA ETC SINGLE STAGE ELECTRONIC TEMPERATURE CONTROL

Have a bright day! Nicholas Harmon President, Verilux, Inc.

Installation and Maintenance Manual (2014)

Transcription:

Spun Bay Installation Standard Version (non dimmable), Hook Mount WARNING: Make sure that all power is turned off while installing fixture. Do not turn power on until fixture is completely installed. Turn power off at circuit breaker box. Do not handle an energized fixture or energize any fixture when hands are wet or when standing on a wet or damp surface, or in water. AVERTISSEMENT: Assurez-vous que l'alimentation est coupée pendant l'installation luminaire. Ne mettez pas sous tension tant que luminaire est complètement installé. Coupez le courant à la boîte du disjoncteur. Ne pas manipuler un appareil hors tension ou sous tension un appareil lorsque vos mains sont mouillées ou debout sur une surface mouillée, humide ou dans l'eau. THIS LED FIXTURE IS A HIGHLY ADVANCED, ENERGY EFFICIENT PRODUCT THAT WILL PROVIDE THE END USER WITH YEARS OF DEPENDABLE SERVICE. IT WILL DO SO ONLY IF INSTALLED PROPERLY IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE AND OR LOCAL CODE SPECIFICATIONS. FAILURE TO ADHERE TO THESE CODES AND RESTRICTIONS MAY RESULT IN SERIOUS INJURY, DAMAGE TO ADJACENT EQUIPMENT, FIXTURE AND OR POWER SUPPLY AND WILL VOID THE WARRANTY. THE DO NOT SUPPORT ALL DETAILS OR VARIATIONS IN EQUIPMENT, NOR DO THEY PROVIDE FOR ALL POSSIBLE CONTINGENCIES RELATED TO THE INSTALLATION, SERVICE OR MOUNTING SITUATION. SHOULD SPECIFIC PROBLEMS OCCUR THAT ARE NOT COVERED BY THE ATTACHED INSTALLATION INSTRUCTIONS, PLEASE CONTACT YOUR SALES REPRESENTATIVE OR DISTRIBUTOR FOR ASSISTANCE. RETAIN THESE INSTALLATION INSTRUCTIONS FOR FUTURE USE. DO NOT MODIFY THIS LIGHTING DEVICE FOR ANY REASON. THESE DEVICES HAVE BEEN DESIGNED FOR MAXIMUM PERFORMANCE AND EASE OF INSTALLATION, ANY MODIFICATIONS WILL VOID THE WARRANTY. Proper grounding of the fixture is essential to prevent risk of shock, to maintain correct operation and to eliminate electrical interference. It is the responsibility of the installer to ensure water cannot enter fixture through conduit or mounting. Install driver and electrical components in dry locations only. If occupancy sensors are installed Sensors and controls are factory set and may need to be adjusted in the field at installation due to environmental factors. 1. Remove fixture from shipping container and verify fixture is in good condition. (FIG 1) Figure 1 Page 1 of 8

2. Hang fixture by hook at top of fixture from secure location that is rated to support fixture weight (27 lbs). (FIG 2) 3. Tighten screw on hook. (FIG 3) Hook Figure 2 Set Screw Figure 3 Page 2 of 8

4. Connect a suitable safety chain or cable to hub (Note: Chain or cable must be rated for fixture weight (27 lbs.)). (FIG 4) Hub Figure 4 5. Plug in or hardwire as appropriate (FIG 5) Figure 5 Page 3 of 8

Spun Bay Installation Standard Version (0 10V dimmable), Hook Mount WARNING: Make sure that all power is turned off while installing fixture. Do not turn power on until fixture is completely installed. Turn power off at circuit breaker box. Do not handle an energized fixture or energize any fixture when hands are wet or when standing on a wet or damp surface, or in water. AVERTISSEMENT: Assurez-vous que l'alimentation est coupée pendant l'installation luminaire. Ne mettez pas sous tension tant que luminaire est complètement installé. Coupez le courant à la boîte du disjoncteur. Ne pas manipuler un appareil hors tension ou sous tension un appareil lorsque vos mains sont mouillées ou debout sur une surface mouillée, humide ou dans l'eau. THIS LED FIXTURE IS A HIGHLY ADVANCED, ENERGY EFFICIENT PRODUCT THAT WILL PROVIDE THE END USER WITH YEARS OF DEPENDABLE SERVICE. IT WILL DO SO ONLY IF INSTALLED PROPERLY IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE AND OR LOCAL CODE SPECIFICATIONS. FAILURE TO ADHERE TO THESE CODES AND RESTRICTIONS MAY RESULT IN SERIOUS INJURY, DAMAGE TO ADJACENT EQUIPMENT, FIXTURE AND OR POWER SUPPLY AND WILL VOID THE WARRANTY. THE DO NOT SUPPORT ALL DETAILS OR VARIATIONS IN EQUIPMENT, NOR DO THEY PROVIDE FOR ALL POSSIBLE CONTINGENCIES RELATED TO THE INSTALLATION, SERVICE OR MOUNTING SITUATION. SHOULD SPECIFIC PROBLEMS OCCUR THAT ARE NOT COVERED BY THE ATTACHED INSTALLATION INSTRUCTIONS, PLEASE CONTACT YOUR SALES REPRESENTATIVE OR DISTRIBUTOR FOR ASSISTANCE. RETAIN THESE INSTALLATION INSTRUCTIONS FOR FUTURE USE. DO NOT MODIFY THIS LIGHTING DEVICE FOR ANY REASON. THESE DEVICES HAVE BEEN DESIGNED FOR MAXIMUM PERFORMANCE AND EASE OF INSTALLATION, ANY MODIFICATIONS WILL VOID THE WARRANTY. Proper grounding of the fixture is essential to prevent risk of shock, to maintain correct operation and to eliminate electrical interference. It is the responsibility of the installer to ensure water cannot enter fixture through conduit or mounting. Install driver and electrical components in dry locations only. If occupancy sensors are installed Sensors and controls are factory set and may need to be adjusted in the field at installation due to environmental factors. 1. Remove fixture from shipping container and verify fixture is in good condition. 2. Hang fixture by hook at top of fixture from secure location that is rated to support fixture weight (27 lbs.). (See example in FIG 2) 3. Tighten screw on hook. (See example in FIG 3) Page 4 of 8

4. Connect a suitable safety chain or cable to hub (Note: Chain or cable must be rated for fixture weight (27 lbs.)). (See example in FIG 4) 5. Plug in or hardwire as appropriate. (See example in FIG 5) 6. Make the following dimming wire connections (See example in FIG 6): a. Connect the white lead to the (+) positive terminal of the DC voltage source. b. Connect the black lead to the ( ) negative terminal of the DC voltage source. Note: This fixture is supplied with 0 10 volt dimming leads to offer the user a simple and economical solution to increase energy savings. However, the dimming control will be operated from an input signal ranging from 1 10 VDC. The dimming control may be operated over the entire 1 10 volt range with output current varying from 100% down to practically 10%. The dimmer signal is allowed to be less than 1 volt, however, when it is from 0 1 volt, the output current may not be linear. Figure 6 Page 5 of 8

Spun Bay Installation Standard Version (non dimmable), Pendant Mount WARNING: Make sure that all power is turned off while installing fixture. Do not turn power on until fixture is completely installed. Turn power off at circuit breaker box. Do not handle an energized fixture or energize any fixture when hands are wet or when standing on a wet or damp surface, or in water. AVERTISSEMENT: Assurez-vous que l'alimentation est coupée pendant l'installation luminaire. Ne mettez pas sous tension tant que luminaire est complètement installé. Coupez le courant à la boîte du disjoncteur. Ne pas manipuler un appareil hors tension ou sous tension un appareil lorsque vos mains sont mouillées ou debout sur une surface mouillée, humide ou dans l'eau. THIS LED FIXTURE IS A HIGHLY ADVANCED, ENERGY EFFICIENT PRODUCT THAT WILL PROVIDE THE END USER WITH YEARS OF DEPENDABLE SERVICE. IT WILL DO SO ONLY IF INSTALLED PROPERLY IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE AND OR LOCAL CODE SPECIFICATIONS. FAILURE TO ADHERE TO THESE CODES AND RESTRICTIONS MAY RESULT IN SERIOUS INJURY, DAMAGE TO ADJACENT EQUIPMENT, FIXTURE AND OR POWER SUPPLY AND WILL VOID THE WARRANTY. THE DO NOT SUPPORT ALL DETAILS OR VARIATIONS IN EQUIPMENT, NOR DO THEY PROVIDE FOR ALL POSSIBLE CONTINGENCIES RELATED TO THE INSTALLATION, SERVICE OR MOUNTING SITUATION. SHOULD SPECIFIC PROBLEMS OCCUR THAT ARE NOT COVERED BY THE ATTACHED INSTALLATION INSTRUCTIONS, PLEASE CONTACT YOUR SALES REPRESENTATIVE OR DISTRIBUTOR FOR ASSISTANCE. RETAIN THESE INSTALLATION INSTRUCTIONS FOR FUTURE USE. DO NOT MODIFY THIS LIGHTING DEVICE FOR ANY REASON. THESE DEVICES HAVE BEEN DESIGNED FOR MAXIMUM PERFORMANCE AND EASE OF INSTALLATION, ANY MODIFICATIONS WILL VOID THE WARRANTY. Proper grounding of the fixture is essential to prevent risk of shock, to maintain correct operation and to eliminate electrical interference. It is the responsibility of the installer to ensure water cannot enter fixture through conduit or mounting. Install driver and electrical components in dry locations only. If occupancy sensors are installed Sensors and controls are factory set and may need to be adjusted in the field at installation due to environmental factors. 1. Remove fixture from shipping container and verify fixture is in good condition. (See example in FIG 1) Page 6 of 8

2. Guide wire through the ¾ 14 NPT conduit fitting, thread into, and tighten in the Spun Bay hub. (See example fitting in FIG 7) Figure 7 ¾ Conduit Fitting 3. Mount fixture by threading into pre installed secure mounting location hub that is rated to support fixture weight (27 lbs.). 4. Connect a suitable safety chain or cable to hub (Note: Chain or cable must be rated for fixture weight (27 lbs.)). (See example in FIG 8) Hub Chain/Cable Connection Tab Figure 8 Page 7 of 8

5. If necessary, connect wiring from input source to Spun Bay inside of pendant junction box (not provided) or other approved wire connection space. (See example in FIG 9) Junction Box Figure 9 6. Plug in or hardwire as appropriate. (See example in FIG 5) Page 8 of 8