READ AND SAVE THESE INSTRUCTIONS FOR THE DUCTSTAT TEMPERATURE SENSITIVE SWITCH

Similar documents
QSSE, QSSEX INDUSTRIAL Battery Chargers

QPET, QPETXU Battery Chargers

DESIGN-AIRE SL-RSR-EC. Installation and Operations Manual

CRS1, CRS2 and CRS3. For additional information please call our. PRO CHARGING SYSTEMS, LLC 1551 Heil Quaker Boulevard, LaVergne, TN

Pump Sentry. Models 812 PS & 1612 PS INSTALLATION INSTRUCTIONS

DESIGN-AIRE SL-RSR-EC. Installation and Operations Manual

Part No DROP IN POPCORN WARMERS Instruction Manual Model #2343, 2344, 2345

BATTERY SAVER LOW RIPPLE HO

OBE, OBEXU, ON BOARD Battery Chargers

OBAE, OBAEXU, ON BOARD Battery Chargers

AUTO CHARGE D2 MODEL #: AUTOMATIC TRIPLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

IMPORTANT RECEIVING INSTRUCTIONS:

QUALITY MISTING PUMPS

AUTO CHARGE D PUMP PLUS

Operations & Maintenance Manual DFH-1000 DUCTLESS FUME HOOD

INSTALLATION AND OPERATING INSTRUCTIONS

O P E R A T I N G I N S T R U C T I O N S

FEATURES. Power Status and Charge Indicator: A red LED indicates the battery is charging and a green LED indicates the battery is fully charged.

OWNER'S MANUAL & INSTALLATION INSTRUCTIONS 6500 Series

O W N E R ' S M A N U A L

Easy/Tran TF STANDBY POWER FURNACE SWITCH TOOLS NEEDED FOR INSTALLATION. PARTS LIST for Easy / Tran TF FURNACE TRANSFER SWITCH

FHC-1D user manual. Features

user s manual Model number

Air flow GUV-161. Box size is 8.25 high x 4.25 wide For service please call Germicidal UV-C Lamp. Furnace. 2.

AUTO CHARGE 4000 MODEL #: AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL. Ph: Fax:

Automatic Emergency Light

SUBMERSIBLE MINI-PUMP

OPERATING INSTRUCTIONS BULLETIN MODEL DA750 March MAGNETIC INSPECTION UNIT

BusPro Series Instruction Manual

ROLLER GRILL Instruction Manual Model #8223, 8224, Part No Revised:March 2008

AUTO CHARGE DUAL MODEL #: AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL. Ph: Fax:

ME AGS Auto Gen Start System for Coach Generators. Operator s Manual.

OWNER'S MANUAL POWER BOOSTER. Rechargeable 12 Volt DC power supply. Item # Enclose copy of original sales receipt

INSTRUCTIONS FOR THE RELIANCE CONTROLS ARM SERIES AUTOMATIC TRANSFER SWITCH

Operation Care Service

Powerful & Intelligent Submersible Pumps

QUALITY MISTING PUMPS

Owner s Manual Drill and Light Weight Portable Utility Pumps

AUTO CHARGE 12 HO MODEL #: MODEL #: MODEL #: AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

CLEAN POWER TM CPS Series Operator s Manual

9' Warm White /Multi LED Color Changing M5 One Plug tree V INSTRUCTION MANUAL

1200W Paint DRYING Lamp

Instruction Manual. Fudge Puppy Display Case

Installation and Operating Instructions (for chargers shown below)

Cincinnati, OH USA

Item no Smart AC 200 USB. User s Manual

BP1204 INSTALLATION/OWNER'S MANUAL

OWNERS MANUAL IMPORTANT: READ OWNERS MANUAL CAREFULLY MODEL # SQUARE CAT XT OSCILLATING FLOOR MACHINE

Hawk Enterprises of Elkhart THE BRUTE Owner s Manual

AUTO CHARGE 4000 MODEL #: LOW PROFILE CHARGER AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

OWNER S MANUAL Please read this manual before operating your power supply

OWNER S MANUAL PORTABLE POWER COMPACT & ROBUST

SPECIFICATIONS Horsepower: 1.5 HP Running Maximum PSI: 125 PSI Tank Capacity: 15 Gallons CFM: 6 40 PSI 5 90 PSI

CLEAN AIR WORKSTATION REVERSE FLOW. Installation and Operations Manual

28W WORK LAMP Model: CTL28 Part No:

Installation Instructions for Eaton Surge Protective

Operation Care Service

For technical questions and replacement parts, please call

Pro Island Ventilation Hoods

installation and operating instructions for the following xtreme Battery chargers:

600 Amp Battery Jumper with Air Compressor

HAWK. HAWK G2 Raptor Orbital Floor Machine Dry Stripping, Scrubbing, Stripping. Operation Care Service ENTERPRISES

AUTOMATIC SUBMERSIBLE UTILITY PUMP

INSTRUCTION MANUAL MODEL # NOTE : This charger is designed for vehicles with dual batteries and negative ground.

Cordless Sweeper. OWNER S MANUAL Model: CFT Volt DC. Made Exclusively for ALDI Inc. Batavia, IL.,

Owner's Manual. 120 Watt DC-AC Inverter Pure Sine Wave PST-12S-12A. Please read this manual before using your inverter

HOME CHARGER MODE 2. Series to /32A single phase CONTENTS. Manual IMPORTANT SAFETY INSTRUCTIONS 3 SAFETY INFORMATION 4 INSTALLATION 5

OPERATING INSTRUCTIONS. Note: 6V Charging. Requires Manual Shut Off.

Source Capture Air Purification System

4 AMP WATERPROOF BATTERY CHARGER/MAINTAINER INSTRUCTION MANUAL

I1 7.5 Pre-Lit Clear Christmas Tree

SUPER AUTO EJECT DELUXE COVER WITH DIGITAL DISPLAY

Seat Comfort Systems

SPEED KEY After the fan has started, press to change fan speed in sequence of: Low - Medium - High. The corresponding indicator will illuminate.

8 Light Controller. Instruction Manual. With Light Timer 240 Volts. Product # INNOVATING SINCE 1995

MODEL NUMBER: MEDIUM DUTY ONBOARD AIR SYSTEM

900 PEAK AMP PORTABLE JUMP STARTER

High Velocity Series Air Curtains

Installation and Operating Instructions (for chargers shown below)

DUAL LINEAR MOTOR / ACTUATOR CONTROLLER W/ CURRENT SENSING AUTO REVERSE

LOUDSPEAKER OWNER'S MANUAL

ATD WATT INVERTER

BATTERY SAVER LR HO with USB LOW RIPPLE POWER SUPPLY / AUTOMATIC LOAD SWITCH FOR 12VDC VEHICLE SYSTEMS

40 V LITHIUM-ION BATTERY ATTACH YOUR RECEIPT HERE AB13786C 1. kobalttools.com ITEM # /

INSTALLATION/OWNERS MANUAL

2.0Ah BATTERY INSTRUCTION MANUAL

801 BUSINESS CENTER DRIVE MOUNT PROSPECT, ILLINOIS

User s Manual D-Series Blowers and Exhausters

801 BUSINESS CENTER DRIVE MOUNT PROSPECT, ILLINOIS Ext. 322

TS69 TS65 TS55 TS45 TS5768 TS SERIES INSTALLATION/OWNER'S MANUAL

ESE Series Cast Iron Sewage Pumps

24 VOLT AUTOMATIC BATTERY CHARGER PART NO

(R86049) WARNING: To reduce the risk of injury, the user must read and understand the operator s manual before using this product.

MODEL 7100 PORTABLE PIN WELDER OPERATOR S MANUAL

SUBMERSIBLE SUMP PUMPS

ROPE LIGHT ITEM # MODEL #UCL48L. Français p. 8. Español p. 15 ATTACH YOUR RECEIPT HERE. Purchase Date

DUAL 12 Volt-10 Amp AUTOMATIC BATTERY CHARGER

INSTRUCTIONS FOR THE RELIANCE Fast/Tran TM ARL0909 & ARL0909R

User s Guide. Oreck Air Purifier with HEPA Filtration. Important! Read this manual carefully, and keep for future reference.

DM1016S INSTALLATION/OWNER'S MANUAL 10" Marine DVC Subwoofer

Transcription:

READ AND SAVE THESE INSTRUCTIONS FOR THE DUCTSTAT TEMPERATURE SENSITIVE SWITCH IMPORTANT NOTICE With the use of any electrical appliance, it is important to observe all basic precautions to minimize the risk associated with use, such as electrical shock, fire, or injury to persons. Read these instructions before using your DuctStat Temperature Sensitive Switch If you have doubts or are unfamiliar with this type of installation work, seek the services of a qualified electrician. Suncourt Inc. assumes no responsibility for installation of the DuctStat. Never expose the DuctStat to temperatures over 140 F (60 C). For your safety and protection follow all instructions and adhere to applicable building and/or electrical codes. This unit is equipped with a three prong grounded plug. Do NOT attempt to defeat the ground feature of this plug. Defeating this will void the warranty. Do not use the DuctStat outdoors. Do not use the DuctStat in damp or wet locations. INSTALLATION NOTES In order to prevent excessive stress on the mounting screws support the DuctStat unit when unplugging connected devices. The DuctStat is intended to control the automatic On/Off operation of In-Line Duct Fans installed in the ductwork of forced air distribution systems. The DuctStat can also control the line voltage to any electrical device with a maximum current draw of 5 Amperes. The DuctStat is equipped with an external, replaceable 5 AMP fuse to protect the electronic circuitry from overload or short circuits.

This unit is equipped with a three prong grounded plug. Do NOT attempt to defeat the ground feature of this plug. Defeating this will void the warranty. INSTALLATION INSTRUCTIONS 1. Locate the position between the In-Line Duct Fan and the register where you wish to mount the DuctStat. Mount between 1 and 10 feet downstream from the In-Line Duct Fan. 2. Tape the template supplied with the DuctStat to the air duct to mark the mounting holes to be drilled. 3. Drill a hole in the air duct for the Air Intake Hole shown on the template. This hole should be ½" in diameter. 4. Drill holes in the air duct to line up with the appropriate holes located on the template. On round ducts, two screws placed through the slots in the DuctStat base will be adequate (placement shown on template). On square or rectangular ducts use four screws, one at each corner of the DuctStat (placement shown on template). 5. Tighten the supplied screws snugly in the appropriate placement for your ductwork. DO NOT OVER TIGHTEN 6.Wire a grounded power cord to the In-Line Duct Fan and plug into the outlet on the face of the DuctStat unit. 7. Plug the DuctStat power cord into a 110 volt grounded household outlet. 8. Follow Operation/Settings to adjust the DuctStat unit. 9. Always leave the DuctStat accessible for adjustment and service.

NEVER EXPOSE YOUR DUCTSTAT TO TEMPERATURES OVER 140 F (60 C) OPERATION SETTINGS 1. Make sure the blower on your furnace is not running. 2. Set the Sensitivity Differential switch to the MIN position. 3. Set the Function switch to Auto Heat (winter) or Auto Cool (summer). 4. To adjust the In-Line Duct Fan motor ON/OFF point rotate the Set Point knob in the proper direction for your heating or cooling application until the In- Line Duct Fan motor switches ON, then slightly turn the control knob in the opposite direction until the In-Line Duct Fan motor stops. DO NOT FORCE. IMPORTANT NOTE

To shorten the length of time that your In-Line Duct Fan continues to run after the forced air furnace or air conditioner had shut off, rotate the Set Point knob control slightly further, as in Step Two. Should you experience frequent On/Off cycling, move the Sensitivity Differential switch to the MAX position. HEAT-COOL SETTING LOGIC If you want the DuctStat to turn a device on when the temperature rises above your set point you put it on the heat setting. If you want the DuctStat to turn a device on when the temperature falls below your set point you will want to put it on its cool setting. The DuctStat will deactivate when the temperature returns to your predetermined set point. ONE YEAR LIMITED WARRANTY Subject to the following limitations, Suncourt Inc. (manufacturer) warrants that the DuctStat Temperature Sensitive Switch will, for 1 (one) year from date of original retail purchase, but not exceeding two years from date of manufacture, remain free from appearance of defects in workmanship or materials. This warranty is subject to the following limitations: (a) manufacturer's liability is limited to the replacement or repair of the unit, as decided by the manufacturer; (b) a defective unit must be returned, prepaid, with proof of purchase; and (c) this warranty does not apply to defects resulting from the alteration, abuse, accidental damage, unauthorized repair, or misuse of the unit. This warranty is given in lieu of all other warranties, guarantees, and conditions on manufacturer's part, and the manufacturer shall have no tortious or other liability in respect to this DuctStat Temperature Sensitive Switch.

Suncourt Inc. reserves the right to change product specifications without notice. Actual product appearance may differ from illustrations. Suncourt reserves the right to modify any or all of its products features, designs, components and specifications without notice.