RHM 06. One of the Most Popular Rheonik Mass Flowmeter Serving Thousands of Worldwide Applications. Applications. Advantages.

Similar documents
RHM 08. One of the most popular Rheonik Mass Flowmeter serving thousands of worldwide applications. Applications. Advantages.

RHM 03. Flexible Coriolis Mass Flowmeter for low flow measurements. Applications. Features. Advantages

RHM 04. Universal Coriolis Mass Flowmeter with particular Fast Response. Applications. Features. Advantages

RHM 015. Ultimate Low Flow Coriolis Mass Flowmeter. Applications. Features. Advantages

RHM 04 - Universal Coriolis Mass Flowmeter with particular Fast Response

RHM 12 - Standard 1 inch Coriolis Mass Flowmeter

Ultimate Low Flow Coriolis Mass Flowmeter

RHM 60. Coriolis Mass Flowmeter for Medium Flow also Suited for High Pressure Applications. Applications. Advantages. Features

Coriolis Mass Flowmeter for low flow measurements

RHM 80 - Coriolis Mass Flowmeter for large flow applications optional heavy duty version

RHM The world s largest Coriolis Mass Flowmeter for flow rates up to kg/min

RHM Coriolis Mass Flowmeter for high Flow Applications

RHM 03 a1 - (low stress in welds and increased wall thickness against abrasion) RHM bar APPLICATIONS. Batching Dosing. Injections Filling

RHM08. Versatile Coriolis Mass Flow Meter. Features. Applications. Benefits

RHM04. Compact Coriolis Flow Sensor With Enhanced Performance. Features. Applications. Benefits

RHM30. Coriolis Mass Flow Meter for Plant and Loading Flows. Features. Applications. Benefits

RHM015. Ultimate Performance Coriolis Mass Flow Meter for Critical Ultra Low Flow Applications. Features. Applications. Benefits

RHM40. Coriolis Mass Flow Meter for Demanding Applications. Features. Applications. Benefits

RHM 015L/02L/03L/04L. Compact Low Flow Coriolis Flow Sensors

RHM 015L/02L/03L/04L. Compact Low Flow Coriolis Flow Sensors

Rheonik Coriolis Mass Flow Meters

Micro Motion Model D and DL Coriolis Flow and Density Meters

7000 Series OPTIMASS Mass Flowmeters. Titanium Hastelloy Stainless Steel

Micro Motion T-Series Straight-Tube Mass Flow and Density Meters. Product Data Sheet PS July 2001

Micro Motion F-Series Coriolis Flow and Density Meters

LIQUID CONTROLS A Unit of IDEX Corporation

Options guide. Electromagnetic flowmeters. M9xx

OPTIMASS 3000 Technical Datasheet

Product Data Sheet PS February Model D and DT. Mass Flow and Density Sensors.

BGN. All Metal Variable Area Flow Meter. Technical Data Sheet

Flow Measurement SITRANS F M. Flow sensor MAG /85. Overview

OPTIMASS 2000 Technical Datasheet

OPTIGAS 4010C Technical Datasheet

Flow Measurement SITRANS F M. Flow sensor MAG 1100 F 4/57

Flow Measurement SITRANS F C. Flow sensor MASS 2100 DI 3 to DI 40. 4/180 Siemens FI

KROHNE 10/ Optimass 70 & 71 Single Tube Coriolis Mass Flowmeters for the Chemical Industry

OPTIGAS 4010C Technical Datasheet

Micro Motion ELITE High Capacity Coriolis Flow and Density Meters

Micro Motion Model CNG050 Compressed Natural Gas Flowmeters

Flow Measurement SITRANS F C

KROHNE 10/ Optimass 70 & 71 Single Tube Coriolis Mass Flowmeters for the Pharmaceutical Industry

Micro Motion ELITE Coriolis Flow and Density Meters

SITRANS F flowmeters SITRANS F US. SITRANS FUT1010 Ultrasonic flowmeter. Overview. Application

Vortex Flowmeters VFM 3100 F-T VFM 3100 W-T

VersaFlow Coriolis 100 Mass Flow Sensor Specifications

SITRANS F M. Flow sensor MAG 1100 F 3/59

SITRANS F flowmeters SITRANS F C

KROHNE 10/ Optimass 70 & 71 Single Tube Coriolis Mass Flowmeters for Food & Beverage Processing

Micro Motion F-Series Coriolis Flow and Density Meters

ISTEC MAGNETIC METERS

Flow Measurement SITRANS F C

SITRANS F flowmeters SITRANS F C SITRANS F C MC2 4/169. Overview

Micro Motion Model CNG050 Compressed Natural Gas Flowmeters

Coriolis Mass Flow Measuring System promass 64

Flow Measurement SITRANS F M

VersaFlow Vortex 100 Vortex Flow Meter Specifications

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

MASSMAX 1000 Series Straight twin tube Coriolis Mass Flowmeter

Level Measurement Point level measurement - RF Capacitance switches

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

Metal tube variable area flowmeter for gases, liquids and steam

Micro Motion 7827 Digital Viscosity Meter

OPTIFLUX 6000 Technical Datasheet

SITRANS F flowmeters SITRANS F C MASSFLO MASS MC1. 4/146 Siemens FI Overview

Level Probes multicap T DC 12 TE multicap T DC 11/16/21/26 TEN/TES

Micro Motion ELITE High Capacity Coriolis Flow and Density Meters

Coriolis Flow Solutions for a Global Marketplace

Micro Motion ELITE Mass Flow and Density Meters

OM004, OM006 & OM008 Oval Gear Meter

Sentinel Panametrics Custody Transfer Gas Ultrasonic Flowmeter

SITRANS F C. Flow sensor MC2 4/193. Overview

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

Differential Pressure Gauges (701P Series)

TURCK DC Insertion Flow Monitors

Sentinel. Panametrics Custody Transfer Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

Food & beverage. Oil & gas. Water & waste water

EGM5300C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

Coriolis Flow Solutions for a Global Marketplace

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control. Benefits.

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Sensing & Inspection Technologies. Benefits.

Electro-Magnetic Flowmeters Sensors MagMaster MFE

VersaFlow Vortex 100 Vortex Flow Meter Specifications

Magnetic-inductive flow meter EPS / UMF2. Technical data sheet

Applications. T h e C o r i o l i s E x p e r t s

LCMass Series Mass Flow Sensor

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview.

Ultra High Purity Transducer, Ex na nl Models WU-20, WU-25 and WU-26

TORRIX Magnetostrictive level sensor

Technical Data Sheet PS , Rev C May Micro Motion R-Series Coriolis Flow and Density Meters

Coriolis Flowmeters. Coriolis Flowmeters. KCM C-flow series Coriolis mass flowmeter

Magnetic-inductive flow meter for hazardous areas

SITRANS F M flow sensors 711/A and 711/911E

Electromagnetic Flowmeters. Product Overview.

Micro Motion F-Series Flow and Density Meters

UNIK 5800/5900. Flameproof/Explosion-Proof Pressure Sensing Platform. GE Measurement & Control. High Quality. Features. Bespoke as Standard.

Flowmeters. The Satam flowmeter range is used for the custody transfer measurement of liquid hydrocarbons, liquid gas and liquid chemicals.

KDM ARMORED FLOW METER & SWITCH

SITRANS FC. Flowmeter SITRANS FC410

OPTISWITCH 4000/5000. Vibration level switches for liquids

ORIMAS Mass Flowmeter

Transcription:

RHM 06 One of the Most Popular Rheonik Mass Flowmeter Serving Thousands of Worldwide Applications The RHM 06 can measure flow rates up to 25 kg/min (55 lb/min) with temperatures in excess of 350 C and pressures up to 430 bar. This model is one of the most popular, manufactured by Rheonik, the mass flowmeter experts. Applications Suitable for virtually any mass flow application, such as: General flow control Dosing Batching Injections Filling Features The outstanding features include: Suitable for pressure up to 430 bar Typical measuring ranges from 0.25 kg/min to 25 kg/min (55 lb/min) Typical flows as low as 0.15 kg/min Flow Accuracy of 0.10% Repeatability better than 0.05% Optimised solutions for your batching operation Extra compact design with minimal space requirement ideal for CNG applications EEx Approvals (i.e. ATEX, CSA,...) Custody Transfer Approvals (i.e. PTB, NMI,...) Advantages No pressure effect no deterioration of accuracy due to pressure changes by the patented Omega Shape Patented torsion swinger design assures longest life time and increased safety (low stress in welds and increased wall thickness against abrasion) No moving parts practically no maintenance Removable connection block g

General The Rheonik patent was originally based on the RHM 06. Today this is one of the most popular models in the Rheonik range of mass flowmeters. With flow measurement up to 25 kg/min and the large number of model variants available, this meter is suitable for many applications. As with all other Rheonik meters, this model is based on the patented Omega tube design with increased signal to noise ratio. This unique design, which offers excellent performance and reliability, has created the most satisfied customers worldwide. Unlike other mass flowmeter manufacturers, Rheonik uses a patented torsion rod swinger with the Omega shape and support bars which results in high accuracy measurement, which is independent of pressure, even at very low flow velocities. The meter has also extremely good repeatability and high stability for critical applications.

RHM 06 Specifications Performance RHM 06 Max Flow 25 kg/min (55 lb/min) Standard Models Rates/turndown ratio in (kg/min) in (lb/min) error in % of reading nominal rate Q nom 20.000 44.10 0.15 0.2 * Q max (5:1) 5.000 11.02 0.20 0.1 * Q max (10:1) 2.500 5.51 0.20 0.05 * Q max (20:1) 1.250 2.75 0.20 0.02 * Q max (50:1) 0.500 1.10 0.50 Typical P in bar (psi) 1 cp 100 cp 1000 cp 1.0 (14.9) 6.0 (86.6) 58.1 (842) 0.1 (1.3) 1.4 (21.2) 14.5 (210) ~ 0 (0.4) 0.7 (10.6) 7.2 (104) ~ 0 (0.1) 0.4 (5.2) 3.6 (52) ~ 0 (0) 0.1 (2.1) 1.4 (21) Optimized Low Flow Models (*) /optimized to be operated between 0.012 x Q max and 0.4 x Q max Rates/turndown ratio in (kg/min) in (lb/min) error in % of reading 0.4 * Q max (1:1) 10.000 22.05 0.15 0.02 * Q max (15:1) 0.500 1.10 0.20 0.012 * Q max (30:1) 0.300 0.17 ~ 0.50 (**) (*) serial/single path version offers the same accuracy at half the flow (Q max = 12.5 kg/min) (**) around 0.30-0.70 % accuracy depending on the installation conditions 0.3 (4.4) 2.9 (42.6) 29 (420) ~ 0 (0) 0.1 (2.1) 1.4 (21) ~ 0 (0) ~ 0.1 (1.3) 0.8 (12) Gold Line Models/application fine tuned meters 1 * Q nom (1:1) 20.000 44.10 0.10 0.1 * Q nom (10:1) 2.000 4.41 0.10 0.05 * Q nom (20:1) 1.000 1.10 0.12 1.0 (14.9) 6.0 (86.6) 58.1 (842) ~ 0 (0.2) 0.6 (8.4) 5.8 (84) ~ 0 (0) 0.3 (4.2) 2.9 (42) Repeatability better ± 0.05 % of rate Temperature Better ± 1 C Standard Models Gold Line Models For serial (single pipe/path) sanitary design Qmax is 12.5 kg/min (50%). Data above refer to standard wall thickness. Error of reading (including zero drift) indications refer to reference conditions H 2 O, 18 C to 24 C (66 F to 76 F), 1 bar to 3 bar (15 psi to 45 psi). RHM sensor do not suffer from pressure effect due to torsional oscillation and semi circle (non-deforming) measurement section. Temperature changes of +/- 25 C around the operating point are negligible. Pressure drop refers to Newton liquids, with parallel measuring loops and block/manifold connection. Nominal flow refers to approx. 10 m/s (33 ft/sec) velocity in measuring loops for best performance. Calibration to customer range, with increased accuracy, possible.

General Outline Dimensions RHM 06 Type I (w/removable manifold block - serial [SM0]/parallel [PM0]/PTFE seals) Thread Type: Flange Type: Weight approx. 5 kg (11 lb) Weight approx. 8 kg (18 lb) A1=165 mm (6.50 in) B1=40 mm (1.58 in) H1=234 mm (9.21 in) A2=180 mm (7.09 in) B2=60 mm (2.36 in) H2=255 mm (10.04 in) W = 0 mm for standard temperature models -45/-20 C to 120 C (-49/-4 F to 248 F) and W = 150 mm (5.91 in) for extended (ET1, ET2) and high temperature models(*) Process Connection Face to Face Length (L) (**) Order Code Thread Standard Thread Optional G ½ in female 70 mm (2.76 in) G1 NPT ½ in female 70 mm (2.76 in) N1 Autoclave/(MP) 100 mm (3.94 in) P2 Flange Standard Flange Optional Special 1 in CL 150 acc. ANSI B16.5 260 mm (10.24 in) A1 1 in CL 300 acc. ANSI B16.5 260 mm (10.24 in) A2 1 in CL 600 acc. ANSI B16.5 300 mm (11.82 in) A3 DN25/PN40 acc. DIN 2635 - C 260 mm (10.24 in) D1 DN25/PN100 acc. DIN 2637 - E 300 mm (11.82 in) D2 1 in CL 900/1500 acc. ANSI B16.5 350 mm (13.78 in) A6 DN25/PN160 acc. DIN 2638 - E 300 mm (11.82 in) D3 1 in JIS flanges standard - 260 mm (8.67 in) XX Swagelok standard - 230 mm (9.06 in) XX VCR standard - 230 mm (9.06 in) XX Novaswiss standard - 230 mm (9.06 in) XX (*) For high temperature models (HT) Type II or Type III preferred - see next pages. (**) Customization possible on request. Our standard seals are PTFE - Manifold block on request available without seals but with brazed connection block. The finish type of our ANSI flanges is RF/SF (AARH 125-250 (μ in) - Ra 3, 2 up to 6, 3 (μm)). Others available on request. Above table only shows our general process fittings. For further customization with regard to face to face length and special fittings please contact your local agent.

General Outline Dimensions RHM 06 Type II (sealless welded, parallel measuring loops w/o seals [PF_]) Flange Type: Special Fittings: Weight approx. 8 kg (18 lb) Weight approx. 8 kg (18 lb) A1=165 mm (6.50 in) B1=40 mm (1.58 in) H1=234 mm (9.21 in) A2=180 mm (7.09 in) B2=60 mm (2.36 in) H2=322 mm (12.68 in) W = 0 mm for standard temperature models -45/-20 C to 120 C (-49/-4 F to 248 F) and W = 150 mm (5.91 in) for extended (ET1, ET2) and high temperature models Process Connection Face to Face Length (L) (**) Order Code 1 in CL 150 acc. ANSI B16.5 260 mm (10.24 in) A1 1 in CL 300 acc. ANSI B16.5 260 mm (10.24 in) A2 Standard Optional Special 1 in CL 600 acc. ANSI B16.5 300 mm (11.82 in) A3 DN25/PN40 acc. DIN 2527 - C 260 mm (10.24 in) D1 DN25/PN100 acc. DIN 2527 - E 300 mm (11.82 in) D2 1 in CL 900/1500 acc. ANSI 300 mm (11.82 in) A6 B16.5 1 in CL 2500 acc. ANSI B16.5 300 mm (11.82 in) A8 DN25/PN160 acc. DIN 2527 - E 300 mm (11.82 in) D3 G ½ in female standard - 270 mm (10.63 in) G1 NPT ½ in female standard - 270 mm (10.63 in) N1 Swagelok ½ in tube inlet standard - 360 mm (14.17 in) W1 (SS-810-1-12W) 1 in JIS flanges standard - 260 mm (10.24 in) XX Grayloc or equivalent hubb standard - 230 mm (9.06 in) XX (*) Customization possible on request. The finish type of our ANSI flanges is RF/SF (AARH 125-250 (μinch) - Ra 3, 2 up to 6, 3 (μm)). Others available on request. Above table only shows our general process fittings. For further customization with regard to special fittings and face to face length please contact your local agent.

General Outline Dimensions RHM 06 Type III (sealless welded, serial measuring loops - single path w/o seals [SF0]) Sanitary Fittings: Flange/Other Fittings: Weight approx. 7 kg (15 lb) Weight approx. 8 kg (18 lb) A1=165 mm (6.50 in) B1=40 mm (1.58 in) H1=234 mm (9.21 in) A2=180 mm (7.09 in) B2=60 mm (2.36 in) H2=255 mm (10.04 in) for sanitary fittings H2=322 mm (12.68 in) for flange type W = 0 mm for standard temperature models -45/-20 C to 120 C (-49/-4 F to 248 F) and W = 150 mm (5.91 in) for extended (ET1, ET2) and high temperature models Process Connection Face to Face Length (L) (*) Order Code Sanitary Fittings (**) Flange Other Fittings ½ in Tri Clamp acc. DIN 32676 230 mm (9.06 in) S1 DN10/Sanitary acc. DIN 11851 230 mm (9.06 in) S2 Neumo DN15/PN16 standard - 230 mm (9.06 ) XX 1 in CL 150 acc. ANSI B16.5 260 mm (10.24 in) A1 1 in CL 300 acc. ANSI B16.5 260 mm (10.24 in) A2 DN25/PN40 acc. DIN 2527 - C 260 mm (10.24 in) D1 ½ in CL 150 acc. ANSI B16.5 260 mm (10.24 in) XX ½ in CL 300 acc. ANSI B16.5 260 mm (10.24 in) XX DN15/PN40 acc. DIN 2527 - C 260 mm (10.24 in) XX Swagelok standard - 230 mm (9.06 in) XX (*) Customization possible on request. (**) Fitting material is 1.4435/SS 316L (Tri Clamp acc. DIN 32676) and 1.4301/SS 304 (Sanitary connection acc. DIN 11851). The finish type of our ANSI flanges is RF/SF (AARH 125-250 (μinch) - Ra 3, 2 up to 6, 3 (μm)). Others available on request. Above table only shows our general process fittings. For further customization with regard to special fittings and face to face length please contact your local agent.

General Specifications RHM 06 Approvals ATEX (CESI 02 ATEX 053 X): Ex II 1 G, EEx ia IIC T6-T1 CSA (220705) Class I, Div 1 and 2, Groups A, B, C and D; Type 3 Custody Transfer Approvals (PTB 1.32-97027224 and NMI TC 3382) PED according to directive 97/23/EC available 3A Sanitary Approvals Electrical Connection Junction box/aluminium coated (standard) IP 65 (Nema 4X) (Junction box in SS optional) Cable entry M25 x 1.5 (M20 x 1.5, ½ in and ¾ in NPT optional) Max cable length between RHM and RHE: 100 m (330 ft) 200 m (660 ft) only with factory approval Housing Stainless Steel: 1.4301/SS 304 - others on request - Protection class: IP 65 (Nema 4X) - higher on request - Pressure Rating Pressured part of the meter consists of the measuring loops and the connection part. The weaker of both parts decides the maximum allowed operating pressure. Below is the max. operating pressure of the measuring loops(*). (*) These values are only valid for SS 316Ti & SS 904L materials. Statements for others materials on request. Standard Version: 380 bar @ 120 C (5510 psi @ 248 F) 300 bar @ 210 C (4350 psi @ 410 F) 260 bar @ 350 C (3370 psi @ 662 F) wall thickness is generally 1.0 mm (0.04 in) Optional low pressure loss version: 190 bar @ 120 C (2755 psi @ 248 F) wall thickness is generally 0.5 mm (0.02 in) Extremely high pressure - on request - Teperature Rating NT Models from -20 C to 120 C (-4 F to 248 F) ET Models from -45 C to 120 C (-49 F to 248 F) ET1 Models from -200 C to 50 C (-328 F to 122 F) ET2 Models from -45 C to 210 C (-49 F to 410 F) HT Models from 0 C to 350 C (32 F to 662 F) Material of Wetted Parts 1.4571/SS 316Ti (standard) 1.4539/SS 904L on request Hastelloy C22 on request Tantalum on request Other material on request

Order Code RHM 06 Order Code Structure The order code of the Rheonik Sensors consists of 6 sections (see previous pages/below). Restrictions of combinations may apply. For specials, please comment your needs in plain text/sketches. RHM 06 Temperature Rating T1 NT Models (Normal Temperature Models) from -20 C to 120 C (-4 F to 248 F) TA ET Models (Extended Temperature Models) from -45 C to 120 C (-49 F to 248 F) T2 ET2 Models (Extended Temperature Models) from -45 C to 210 C (-49 F to 410 F) T3 ET1 Models (Extended Temperature Models) from -200 C to 50 C (-328 F to 122 F) T4 HT Models (High Temperature Models) from 0 C to 350 C (32 F to 662 F) Pressure Rating P1 Low pressure loss version (190 bar @ 120 C/2755 psi @ 248 F) - page 6 - P2 Standard pressure version (380 bar 120 C/5510 psi @ 248 F) - page 6 - PX Extremely high pressure version (on request) - page 6 - Construction Type PM0 Parallel Measuring Loops with removable Block/Manifold and PTFE Seals - page 3 - SM0 Serial Measuring Loops with removable Block/Manifold and PTFE Seals - page 3 - PF_ Parallel Measuring Loops Seal Less Welded Version - page 4 - SF0 Serial Measuring Loops Seal Less Welded Version/Single Path - page 5 - XXX Other construction type on request Material of Wetted Parts M1 1.4571/SS 316Ti M2 1.4539/SS 904L M3 Hastelloy C22 M4 Tantalum Process Connection XX Code available on pages 3, 4 and 5. Hazardous Area Approvals NN Without Ex Approvals AT ATEX Approvals (CESI 02 ATEX 053 X) - Ex II 1 G, EEx ia IIC T6-T1 CS CSA Approvals (220705) - Class 1, Div 1/Group A, B, C, and D; Type 3 RHM 06 - - - - - Order Code Example M#06 T1 P2 PM0 M1 G1 AT T1: NT (Normal Temperature Models) from -20 C to 120 C (-49 F to 248 F) P2: Standard pressure version (380 bar @ 120 C/5510 psi @ 248 F) PM0: Parallel Measuring Loops with removable Block/Manifold and PTFE Seals M1: 1.4571/SS 316 Tipart) G1: Female Thread G ½ in AT: ATEX Approvals (CESI 02 ATEX 053 X) M #06 - - - - - - g www.gesensinginspection.com 920-000-01 2008 General Electric Company. All Rights Reserved. Specifications are subject to change without notice. GE is a registered trademark of General Electric Company. Other company or product names mentioned in this document may be trademarks or registered trademarks of their respective companies, which are not affiliated with GE.