Liv-Elir d.o.o. Contact Info: Tel/Fax.: Mob.: Mail: REPAIR AND SERVICE / PRODUCTION

Similar documents
Electrical Machine Service. Overhaul, Conditioning, On-Site Service and Diagnostics. Excellent Technology, Efficiency and Quality

Design specifications

EAL Level 3 NVQ Extended Diploma in Electrical and Electronic Engineering (QCF) 600/9931/8

HIGH POWER RECTIFIER SYSTEMS

Products & Services EQ Series AC Drives. TEAMMaster WOUND ROTOR MOTORS WORLD SERIES SYNCHRONOUS MOTORS. EXPLOSION PROOF (Division 1, Zone 1)

BRUSHLESS EXCITERS FOR TURBINE GENERATORS

Company presentation

The new generation ABB Motor and Generator Service

SWITCHGEAR. 4G cam switches

A Full Line of Low Voltage IEC Motors In-Stock

Subcontracting TEC. Components & subassemblies for electric machines. Electric Components

BHARAT ALUMINIUM COMPANY LTD. SPECIFICATIONS FOR SYNCHRONOUS GENERATOR GENERAL Make : Jinan Power Equipment Factory Type : WX2

Excitation system is of Static Silicon Excitation System, including excitation transformer, thyristors, and AVR.

High Voltage Generators. TM21-TG Series. 2-Pole Air Cooled Turbine Generator Up to 80,000 kw (107,000 HP)

ACCESSORIES FOR SZE2 CABINETS

ELECTRIC MACHINES EUROLAB 0.3 kw

APPENDIX B SPECIFICATION FOR GENERATOR OVERHAUL EMD MODEL AR10 D18... B-1

Models: PMG A and PMG P

50 years experience in offering tailor made solutions to suit every customer s need.

Brake Motors Aluminium Frame Improved Efficiency EFF2

YKK High-voltage Three-phase Asynchronous Motor

CAST RESIN DISTRIBUTION TRANSFORMERS 2016 EDITION

CAST RESIN DISTRIBUTION TRANSFORMERS 2017 EDITION

SINGLE PHASE TEFC CAGE MOTORS

CONTENTS 1 GENERAL 2 STANDARDS. 3 TECHNICAL FEATURES 3.1 Basic Technical Data 3.2 Standard Accessories 3.3 Tolerances

OM DC Motors Series. Ⅱ. Item Define Example:

Asynchronous, Low Voltage, Squirrel Cage, Three Phase Electric Motors

Guideline No.: E-03(201610) E-03 MOTORS. Issued date: October 28,2016. China Classification Society

MILLWRIGHT. Learner Program Content:

Customised drive solutions

In-Line Fans. Roof Fans. Fans ATEX. Centrifugal Fans. Chip Extractors. Domestic Fans. Accessories. Electric Diagrams. General Information.

INTER PLANT STANDARD STEEL INDUSTRY. Corresponding IS does not exist

TVFC Dry and adiabatic cooling

Guideline No.: E-03(201806) E-03 MOTORS. Issued date: June 7, China Classification Society

1. SPECIFICATION. Altitude of motor installation. Information: Resistance and temperature specifications of the PTC thermistor / posistor/.

FCR asynchronous brake motors LS FCR. General information

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS UNIT OBJECTIVES UNIT OBJECTIVES 3/21/2012

EE6351 ELECTRIC DRIVES AND CONTROL UNIT-1 INTRODUTION

ALVARADO (1029 mm) 25 (635 mm) 36.5 (927.1 mm)

ELECTRIC VIBRATORS SPV & SPC

CONTENTS 1 GENERAL 2 STANDARDS. 3 TECHNICAL FEATURES 3.1 Basic Design Data 3.2 Standard Accessories 3.3 Tolerances

STARTER SYSTEM TESTING 5.6

Standardmotoren Standard motors

Side channel pumps PN 16 SOH - SOHB - SOHM. Self-priming centrifugal pumps. Technical description

KONČAR Group. Research and Development

CPLS Asynchronous motors for variable frequency. 95 Nm to 2900 Nm

Axial-flow Fan AFC. Model numbering system AF C / T. Accessories Three phase. Power rate 1.

GOVERNMENT APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

On-Load Tap changer Type V

ANNEX No 1. C 17/05/2006 SGA112B TERMINAL BOX ARRANGEMENT Ex e, Ex na &Ex td V (OPTION 2)

NXPLUS C Single busbar. Maintenance-free for lifetime

THREE PHASE ASYNCHRONOUS MOTORS WITH SQUIRREL CAGE

Series E4F E5F

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

ELECTRIC MACHINES DIRECT CURRENT ALTERNATING CURRENT ELECTROMAGNETIC BRAKES EXCITERS FOR TURBO-GENERATORS KI

MVSS. Technical features

ELECTRIC MACHINES EUROLAB 0.3 kw

Horizontal Circuit Switchers

4.1. Manufacturing field F2 Preformed and field coil windings

CAST RESIN TRANSFORMERS

production program 1

Immersion Pumps PRG sealless

DELPHI THREE PHASE MOTORS

MJB. Model. Up to kva. Power. Up to V. Voltages. Frame 160 ± 900. Pole 4, 6, 8, 10 and 12. (over contact MM) Cooling IC 01

Key features. DESIGNS: - Conservator type - Hermetically sealed

General Catalog. A New Vision for Quality Pumps. General Catalog

Junction boxes for control, monitoring and control panel Ex tb

Protection against mechanical impacts IK 08 according to IEC 68, EN Insulation class Class F (155 C), class H (180 C) on request.

Catalog Mars Low voltage Brake motors

INTER PLANT STANDARD STEEL INDUSTRY SPECIFICATION FOR STATIC EXCITATION CONVERTORS FOR SYNCHRONOUS MOTORS (FIRST REVISION)

champion series motors

Teepak Totally Enclosed Tube Ventilated High Voltage Induction Motors. A Regal Brand.

DC MOTOR MAINTENANCE ALL ELECTRIC LIFT TRUCKS PART NO SRM 294

(1032 mm) 30.5 (775 mm) 44 ( mm)

IECEx Certificate of Conformity Annexe

QUOTATION BLADE 7 LX. Product code GEAL6S2BAA

Motorized Pulley 80LS A very compact strong drive for small high use conveyors

ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW)

Explosion decoupling inside connected ductwork to protect separators

Built-in motors. Contents. Product description 7/2 Overview of technical data 7/3

LSPXMV FCR Atmospheres containing explosive dust FCR asynchronous brake motors. General information

MJH. Model. Up to kva. Power. Up to V. Voltages. Frame 400 ± Pole 4, 6, 8. (over contact MM) Cooling IC 01

Variable speed asynchronous motors with FCR brake LSMV FCR. General information

INDUCTION MOTOR. There is no physical electrical connection to the secondary winding, its current is induced

General purpose aluminum motors Technical data for totally enclosed squirrel cage three phase motors, two-speed

Transformers Global product offering

SIGENTICS HV Series S-modyn

Demag KB conical-rotor brake motors. Drives with unique principle

TECHNICAL REQUIREMENTS FOR ELECTRICAL EQUIPMENT

Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

MJB. Model. Up to kva. Power. Up to V. Voltages. Frame 160 ± 900. Pole 4, 6, 8, 10 and 12. (over contact MM) Cooling IC 01

MTF. Technical features

SINAMICS SM150. 4/2 Overview. 4/2 Benefits. 4/2 Design. 4/6 Function. 4/8 Selection and ordering data. 4/8 Options

Horizontal Circuit Switchers

Institute of Technology, Nirma University B. Tech. Sem. V: Electrical Engineering 2EE305: ELECTRICAL MACHINES II. Handout: AC Commutator Motors

Technical features Certifications

GigaBox centrifugal fans Product specific information

TABLE OF CONTENTS DISCLAMER

Transcription:

REPAIR AND SERVICE / PRODUCTION

REPAIR AND SERVICE Asynchronous, synchronous and collector machines of low and high voltage: Production of coil insulation class B, F, H Production of coil for voltage level 6kVi10kV Impregnation of coils in the vacuum pressure impregnator Establishing accurate shop operation with SPM method vibration measurement, testing under load Pumps, pump units and pumping substations, which are used for water supply, drainage in mining and similar Oil immersed transformers and dry transformers Filtering and insulation oil testing Coil development Welding devices. Generator sets and rectifiers Electrical distribution equipment and machines in the anti explosive "Ex" version. Dynamic balancing of rotating masses and spare parts development for electrical machines PRODUCTION PROGRAM Low voltage metal strips and Silumin strip modules designed for industrial and residential construction Plants for electricity distribution Command distribution cabinets and counters with or without technological scheme for electric power supply, managing and monitoring Electricmotor plants Medium voltage plants for use in mining Silumin mold castings and sand castings Light Silumin poles for street lightning and park lightning Single-phase transformers up to P=15kVA Three-phase transformers up to P=50kVA Inductors and solenoid coils. Electro graphite and metal graphite brushes

HIGH VOLTAGE ELECTRICAL MACHINES We refurbish and service high-voltage synchronous and asynchronous electrical machines voltage level up to 10 kv. High voltage service program includes: Degreasing, washing and drying of all parts of machines Refreshing the coil insulation Dynamic balancing of rotating masses Repair, construction and replacement of damaged parts Idle testing and development of test protocol The program overhaul of HV machines includes: Preparation and replacement of stator and rotor coils in the "F" class insulation Repair and development of the rotor cage Pre-packing tin metal packets for the stator and rotor Dynamic balancing of rotating masses Mechanical systems control Determining bearing validity with the SPM method Replace damaged parts with original parts or fabrication of new (shafts, bearing shields, fans, secretory case, terminal boards, sliding rings, etc.) Impregnation of the coils with high quality paint vacuuming process. We ensure the quality of our work with tests during the technological process of repair and final testing by IEC regulations. Standard operation procedure involves: Partition control measures Control of the air gap Measurement of ohm resistance and coil impedance Measurement of insulation resistance Checking terminal markings and direction of rotation Measuring current, voltage and rotation speed during idle at nominal frequency High voltage test on stator coil Check the transmission ratio stator rotor The work is done by arrangement with the customer, in our workshop or on site.

COLLECTOR ELECTRIC MACHINES Our work program includes all types of ac-dc collector machines and voltage levels. It also includes various special machines such as multi-phase commutation motors, inverter, voltage converters, etc. Service program of collector machines includes: Degreasing, washing and drying all parts of machines Refresh the coil insulation Control of mechanical systems Dynamic balancing of rotating masses Processing collector sliding surface and Inter strip isolation Brush control devices The program overhaul collector machine includes: Preparation and replacement of stator and rotor coils in the "F or "H" class insulation Creating rotor to collector coil connections with the latest procedure of automatic welding Coil impregnation with high quality paint vacuum procedure. If necessary, can produce and replace damaged parts of machines (shafts, bearing shields, fans, etc.) We ensure the quality of our work with tests during the technological process of repair and final testing by IEC regulations, in idling as well as under load testing. The work is done by arrangement with the customer, in our workshop or on site.

LOW VOLTAGE ROTATION ELECTRIC MACHINES Work program includes synchronous and asynchronous high voltage machines, single phase, and three-phase machines with short connecting and ring rotor. The program overhaul of low voltage rotating electrical machines (synchronous and asynchronous) includes: Fabrication and replacement of stator and rotor coils regardless of the type of winding, type of machinery and temperature class Repair or rotor cage fabrication Pre-packing tin metal of the stator and rotor Control of mechanical systems Replacement of damaged parts with the original parts or fabrication of new parts (shafts, bearing shields, fans, secretory cases, docking plates, sliding rings, etc.) Quality-winding impregnation- high quality paint with vacuum procedure. We ensure the quality of our work with tests during the technological process of repair and final testing by IEC regulations. The work is done by arrangement with the customer, in our workshop or on site.

PUMPS AND PUMP UNITS Repair and service of all types of pumps, pump units and pumping substations used for water supply, drainage in mining, sewage systems, etc. Pump and pump units rebuild program includes: High pressure rotary dynamic pumps power to 400 kw and voltage to 1000 V Low compressive drowning (slurry) pumps for dirty and clean water, power up to 150 kw and voltage to 500 V Horizontal and vertical rotary dynamic pumps Circulation centrifugal pumps for hot water During Pump rebuild we perform: Preparation and replacement of stator coils Replacement or repair of damaged parts Spare parts fabrication by sample All rebuilt pumps and pumping aggregates are tested at the test station along recording Q-H diagrams, electrical load and other relevant parameters, and developing an appropriate test protocol.

POWER TRANSFORMERS Rebuild program of the power transformers includes: All types of dry power transformers up to 1600 kva, the standard version voltage level up to 20 kv All types of oil power transformers up to 2500 kva, voltage levels up to 20kV Mining sub -station in Ex version, production "KONCAR", power 200 630 kva and 7.2 kv voltage level During power Transformer rebuild we perform: Preparation and coil replacement Filtering and replacement of transformer oil Audit connections, clamping yokes, voltage regulator, thermal and Buholtz protection Overview of the boiler, and conservator and air dryer Control of transformer oil penetrability WE PRODUCE DRY TRANSFORMERS UP TO 50 kva

WELDING MACHINES Repair and service equipment for arc and resistance welding, automatic and semi-automatic welding devices, and procedures MAG, TIG, MIG rotary welding machines. The repair and rebuild program covers all types of machinery and welding machines: Converter for arc welding Diesel electric generators for welding Adjusters for arc welding Transformers for arc-welding Devices for semi-automatic arc welding in an protective gas atmosphere Devices for semi-automatic arc welding Devices for TIG welding During rebuild and service of welding machines we perform: Production and coil exchange in the "B", "F" and "H" class Replacement of defective parts, such as: bearings, thyristors, diodes, electronic assemblies, the bearing housing, terminal case, carriers brushes, brushes, switches, etc. Collector processing, control and adjustment by the recommendations of the producers. All rebuilt and serviced appliances are tested in a test station with development of test protocols, which contains all the technical data of the rebuild devices, and test results.

ELECTRICAL EQUIPMENT Measuring cabinets for individual installation: Cabinets for house connections made ofcorrosion protected steel sheet painted with RAL 7032. Meet the Electricity Regulations-BiH. Cable connection cabinet type SPO: Made of cast Silumin, colored with varnish RAL 7032, the degree of mechanical protection IP 55. Installed one fuse EC 25 Cable terminal box KPO: Battery Junction: Housing cabinets made of cast Silumin painted light gray varnish RAL 7032 The degree of mechanical protection IP 55 Made in three versions (depending on the mounted fuse base): 1. KPO 3 x 160 A; 2. KPO 3 x 250 A KPO 3 x 400 A; 3. KPO 6 x 160 A; KPO 6 x 250A; KPO 6 x 400 A; Silumin alloy boxes that are made in four basic dimensions: K1, K2, K3 and K4 Closing the box is performed by the lid or door Boxes K1 and K3 have four side opening, and K2 and K4 six side opening Box Dimensions K1 and K2 same as K3 and K4 are engineered to the size ratio 1:2, so that their combination can make the two systems.

FREE-STANDING DISTRIBUTION CABINETS A free standing distribution cabinets are used in electrical power and Industrial plants for the supplying consumers with electricity as well as management technological processes. Made as a field with one or two doors, which are compiled depending on project requirements and client demand. HOUSING: Stable housing Specially made with a fivefold profile groove against rain and dust on the front side If used as a separate casing, then made from steel, so that the sides and cross-section create unit on which is mounted lid from the back and door from the front side MOUNTING PLATE: The mounting plate adjustable in depth and reinforced GROUND: Performed on the case, door and mounting plate SIDE PANELS: Used as the final elements of the serial connection cabinet MECHANICAL PROTECTION: IP 43 / IP 54 Anti-Corrosion protection is performed by electrostatic application method of powder (RAL 7032) Mounting bracket on the perforated side of the cabinet for deep setting mounting plates, other devices and elements Prepared openings for: transportation eyebolts, hinges, reinforce on the stand or floor. Simply connect the individual cabinets without inner frame Sealing closet flange to the ceiling make easier introduction of cables from above DOOR: Stable door additionally reinforced with vertical perforated mounting rails. Seal on the entire perimeter Water-resistant closure.

FREESTANDING DISTRIBUTION CABINET DURING INSTALATION

FREESTANDING CABINETS FOR ELECTRIC ENERGY DISTRIBUTION Type NNRO Free-standing distribution cabinets are equipped with main switch that contains electromagnetic and thermal protection, and fuse-disconnecting drains stripes. Possible solutions are also without the switch to direct supply cable or Bus connection to the bus NNRO. In both variants NNRO is equipped with instruments for measuring voltage and current. They are used in substations, as well as industrial plants, and technical solutions meet the recommendations and regulations EP BiH. NNRO are made from steel plate protected final varnish RAL 7032.

PRODUCTION OF BRUSHES FOR ELECTRIC ROTATION MACHINES PRODUCE ELECTRICAL AND METALGRAPHITE BRUSHES

MACHINING PROCESSES, SILUMIN FOUNDRY AND DYNAMIC C BALANCING ROTATION MASS Machining program includes: Processing on the lathe to the diameter of 1410 mm All types of milling process All types of processing by drilling Flat grinding length up to 1000 mm Production program Silumin foundry: Production of models in its own pattern shop Making tools for casting Casting of Aluminium alloys in sand and molds Production of Aluminium parts for a variety of purpose Dynamic balancing of rotating masses includes: Diameters up to 1600 mm Length to 3600 mm Weight to 5000 kg Number rpm per minute to 5000

LIGHT SILUMIN POLES FOR STREET LIGHTING AND PARKS Pole is made from Silumin elements, on which are assembled various types of lamp posts on various heights. Lamp post heights: h1 = 1.040 mm h2 = 1.600 mm h3 = 1.920 mm h4 = 3.160 mm