Pressure independent combined control and balancing valves with independent EQM characteristics

Similar documents
TA-FUS1ON-P. Combined control & balancing valves Pressure independent combined balancing and control valves with independent EQM characteristics

TA-PILOT-R. Differential pressure controllers Pilot operated differential pressure controller with adjustable set-point

Pressure independent balancing and control valve For ON/OFF control

STAF-SG. ANSI flanges. Balancing valves DN

STAF, STAF-SG. Balancing valves PN 16 and PN 25 DN

STAF, STAF-SG. Balancing valves PN 16 and PN 25 DN

KTM 512. Union threads/ansi flanges. Combined control & balancing valves Pressure independent balancing and control valve DN

Pressure independent balancing and control valve

STAF-SG. ANSI flanges. Balancing valves Size 3/4-16

DA 50. Differential pressure controllers Adjustable set-point

Thermostatic radiator valves with presetting

TA-Mini-Fast-Fit. Prefab units Fabricated solutions for small terminal units

ZONE CONTROLE / 2-WAY

CV 206/216/306/316 GG. Standard control valves 2- or 3-way, DN , cast iron

TA-6-way valve. Standard control valves 6-way valve for change-over systems

TA-6-way valve. NPT threads. Standard control valves 6-way valve for change-over systems

Mikrotherm F. Manual Radiator Valves With presetting

RADIATOR VALVES / RADIATOR VALVES WITH PRESETTING

RTL. Floor Heating Controller Return temperature limiter with and without presetting

Floor heating manifold with automatic flow control

TRIM, TRIM A, RADITRIM A, TRIM K, STK, TA Loop

Dynacon. Floor Heating Manifolds Floor heating manifold with automatic flow control

Harmony Installation, Operation and Maintenance

CCO kit. Compact Change Over - 6-way switch valve with motor QUICK FACTS

Static Balancing Valve

Valves, controllers + systems Double regulating and commissioning valves Hydrocontrol F cast iron, PN 16

dynacon floor heating manifold with automatic flow control

Hydrocontrol VFC cast iron, PN 16 Hydrocontrol VFR bronze, PN 16 Hydrocontrol VFN nodular cast iron, PN 25 Double regulating and commissioning valves

Double regulating and commissionig valves Hydrocontrol F cast iron, PN 16 Hydrocontrol FR bronze, PN 16 Hydrocontrol FS nodular cast iron, PN 25

V5032. Kombi-2-plus Manual double regulating balancing valve. Product specification sheet

HERZ 7217 V. Integral Fixed Orifice Control Valve HERZ 7217 V. Data sheet 7217 V, Issue Size in mm. STRÖMAX Fig No DN L Lm Rp H SW kv kvs

Valves, controls + systems Cast iron double regulating/ commissioning valves PN 16 Hydrocontrol G

Automatic balancing valves ASV-PV DN (3rd gen.)

Series 02: DN40 and DN50 Series 01: DN Three-port slipper valves PN6

Flow controller (PN 25) AVQ - return and flow mounting

Regutec F. Return Lockshield Radiator lockshield

Modulating control valve PN16 with magnetic actuator

Modulating control valve PN16 with magnetic actuator

Flow controller (PN 25) AVQ - return and flow mounting

3-port seat valves PN16 with flanged connection

Butterfly valves PN6, PN10, PN16

3-port seat valves, external thread, PN16

VALVE FEATURES AVAILABLE MODELS LIMITS OF USE IP 67

RADIATOR VALVE ACCESSORIES

Technote. Frese OPTIMA - Pressure independent control & balancing valve. Application. Features. Benefits.

3-Port Seat Valves with Male Thread, PN 16

Ballorex Venturi 3.1 Introduction

2- and 3-port valves with flanged connections, PN 16

Overview of types. Technical data

V5000. Globe Valves Series for Terminal Units. Product Bulletin

Technote. Frese OPTIMA Compact DN10-DN50 - pressure independent balancing & control valve. Application. Features. Benefits.

Modulating Control Valve PN 16 with Magnetic Actuator

Combi valves PN 16 with flanged connections

Description. Ballorex Venturi. Versions. Benefits. Robinets manuels Balancing

VPI45.. VPI45..Q. Combi valves, PN 25. Building Technologies. VPI45..Q with pressure test points ACVATIX

Control valves with electric actuators up to 90 C PN

Motorized Butterfly Valve

VPI45..Q with pressure test points. Combi valves, PN 25

Combined automatic balancing valve AB-PM valve DN 10-32, PN 16

Globo P. Ball valves Pump ball valve made of gunmetal

Pressure independent balancing and control valve AB-QM DN

VPA Series and VAP Actuator

FlowCon SM mm. Dynamic Self Balancing Control Valve SPECIFICATIONS

3-port valves vxf42..

Pre-Fabricated Flushing Bypass Assembly for Plant Applications Hero Plant DN15-150

Butterfly valves PN 16

2-Port Seat Valves with Flange, PN 25

VDL : 2-way regulating valve for dynamic hydronic balancing, PN 25, Valveco compact

Control of cutting-oil emulsion for industrial grinding machines. Applications for CHW and LPHW systems, see data sheet CA1N4454E.

3-Port Seat Valves with Male Thread, PN 16

2- and 3-port valves with flanged connections, PN 16

ROTARY MOTORIZED VALVES ROTARY MOTORIZED VALVES

VG6000 Series Forged Brass Valves

Three-port slipper valves PN10, female-threaded

three-way mixing valve

AVQMT. AVQT controller can be combined with AVT or STM thermostatic actuators.

FO-BV Series. Fixed-orifice balancing and control valves. Technical Data Sheet. WattsIndustries.com

ARI-STEVI 450 / 451 (DN15-150) Control valve - 3-way-form (mixing/diverting valve) (optional with screwed seat ring)

Pressure independent balancing and control valve

ARI-STEVI 450 / 451 Pneumatic actuator ARI-DP 32-34T. Electric actuator ARI-PREMIO 2,2-25 kn ARI-PREMIO-Plus 2G 2,2-25 kn

Butterfly valves, PN6, PN10, PN16

Two-port seat valves with male thread, PN16

Flow-compensated temperature controller AVTQ DN 15

Combined automatic balancing valve AB-PM valve DN 15-25, PN 16

Series 46 Self-operated Regulators Differential Pressure and Flow Limiters Type 46-5 Type 46-6

PIC-V Valve... 1 Unimizer (1/2 to 3 )... 2 Unimizer (4 to 6 )... 3 Automizer... 4 MVP Valve... 5

We proudly deliver a unique and

Static Balancing Valve

V5000, V5010 Kombi-3-plus BALANCING AND SHUTOFF VALVES

Differential pressure controller (PN 16, 25, 40) AFP(-9) / VFG 2(1) return and flow mounting, adjustable setting

ARI-STEVI 450 / 451 (DN15-150) Control valve - 3-way-form (mixing/diverting valve) (optional with screwed seat ring)

3-port seat valves PN6 with flanged connection

3-port seat valves PN16 with flanged connection

CONTROL EQUIPMENT STAZ-16, STBZ-16

Innovation + Quality. Valves, controls + systems Balancing and Control Valves

Type 3273 Hand-operated Actuator Type 3273 Side-mounted Handwheel

2-port seat valves PN16 with flanged connection

VBF21.. Three-port slipper valves PN6. Series 02: DN40 and DN50 Series 01: DN

GRINNELL MODEL CB800 CIRCUIT BALANCING VALVE INSTALLATION & SETTING HANDBOOK

k VS DN (mm) Connections ( C) (m 3 /h)

Transcription:

Combined control & balancing valves TA-FUS1ON-P Pressure independent combined control and balancing valves with independent EQM characteristics Pressurisation & Water Quality Balancing & Control Thermostatic Control ENGINEERING ADVANTAGE These innovative pressure independent control and balancing valves for heating and cooling systems combine the key hydronic functions of control and balancing in one valve. Adjustable max. flow and inherent independent EQM characteristics allow correct valve sizing and optimum system controllability. The measuring points enable accurate measurement of flow, differential pressure, temperature and available differential pressure.

Adjustable max. flow Adjustable Kvs technology allows setting to design flow. Independent, inherent EQM characteristic Proper EQM valve characteristic and high authority for all settings. Self-sealing measuring points Simple and accurate measurement for balancing, trouble shooting and power measurement. Actuators Valves and actuators supplied together ensuring optimum control performance and simplified selection. Technical description Application: Heating and cooling systems. Functions: Control (EQM) Differential pressure control Pre-setting (max. flow) Measuring (ΔH, T, q) Shut-off (for isolation during system maintenance) Flushing Dimension: DN 32-150 Pressure class: DN 32-50: DN 65-150: and Differential pressure (ΔpV): Max. differential pressure: DN 32-50: 350 kpa = 3,5 bar DN 65-150: 400 kpa = 4 bar Min. differential pressure: DN 32-50: 15 kpa = 0,15 bar DN 65-80: 25 kpa = 0,25 bar DN 0-125: 30 kpa = 0,30 bar DN 150: 40 kpa = 0,40 bar (Valid for position, fully open. Other positions will require lower differential pressure, check with the software TA- Select.) Recommended flow range: The flow (q max ) can be set within the range [m 3 /h]: DN 32: 0,88-4,30 DN 40: 1,01-6, DN 50: 2,58 -,9 DN 65: 9,40-25,2 DN 80: 14,5-38,7 DN 0: 26,9-71,6 DN 125: 45,4-121 DN 150: 75,0-200 Important: All values are provisional and may be subject to change. Please check the website for up-to-date information. q max = l/h at each setting and fully open valve plug. Lift: 20 mm Rangeability: >0 (for all recommended settings) Leakage rate: Tight sealing Characteristics: Independent EQM. Temperature: Max. working temperature: 120 C Min. working temperature: -20 C Media: Water or neutral fluids, water-glycol mixtures. (For other media contact TA Hydronics.) 2

Material: DN 32-50: Valve body: AMETAL Valve plug: AMETAL Seat seal: EPDM/Stainless steel Spindle seal: EPDM O-ring O-rings: EPDM Valve insert: AMETAL /PPS/PTFE Δp insert: Stainless steel/pps Membrane: HNBR Springs: Stainless steel Spindle: Stainless steel DN 65-150: Valve body: Ductile iron EN-GJS-400 O-rings: EPDM Valve plug: Stainless steel Seat seals: EPDM/Stainless steel Plug mechanisms: Stainless steel and brass Membrane: EPDM Δp spring: Stainless steel. DN 150 painted steel. Screws and nuts: Stainless steel Marking: DN 32-50: TAH, IMI, DN, PN, DR, serial No and flow direction arrow. DN 65-150: TAH, IMI, DN, PN, Kvs, T min / max, serial number, valve body material and flow direction arrow, label. Surface treatment: DN 32-50: Non treated DN 65-150: Electrophoretic painting. Connection: DN 32-50: Female thread according to ISO 228. Thread length according to ISO 7/1. DN 65-150: Flanges according to EN-92-2, type 21. Face to face length according to EN 558-1 series 1. AMETAL is the dezincification resistant alloy of TA Hydronics. 3

Operating function DN 32-50 Setting DN 32-50 Venting DN 32-50 1. Open the valve fully with the handwheel. 2. Press the handwheel downwards and turn to desired value, e.g. 5.3. 1. To vent the membrane chamber, open the topmost venting screw. NOTE! Max. 2 turns opening. Shut-off DN 32-50 Measuring q DN 32-50 Connect TA Hydronics balancing instrument to the measuring points. Input the valve type, size and setting and the actual flow is displayed. 1. Turn the handwheel to Closed. Turn the handwheel to Open when re-opening the valve. Flushing DN 32-50 Measuring ΔH DN 32-50 Close the valve according to Shut-off, deactivate the Δp part according to Flushing. Connect TA Hydronics balancing instrument to the measuring points and measure. Important! The valve must be re-opened fully and the Δp part activated after the measurement is completed. H 1. Open the valve fully with the handwheel. 2. Open the setting fully (position ). 3. Deactivate the Δp part by opening the flushing spindle fully (anticlockwise). After flushing, close the flushing spindle and set the valve to previous setting. pv NOTE! Ensure that the actuator is disengaged from the valve spindle during all operating functions described above, except venting. 4

Operating function DN 65-150 Setting DN 65-150 Venting DN 65-150 1. Release the fixing nut. 2. Turn the setting screw to desired value on the scale, e.g. 8.6. 3. Tighten the fixing nut. 1. To vent the membrane chamber, open the topmost venting screw. NOTE! Max. 2 turns opening. Shut-off DN 65-150 Measuring q DN 65-150 Connect TA Hydronics balancing instrument to the measuring points. Input the valve type, size and setting and the actual flow is displayed. 1. Release the fixing nut. 2. Turn the setting screw clockwise to stop (position 0 ±0.5). The presetting is visible on the setting scale. 3. Tighten the fixing nut. Open to previous setting when re-opening the valve. Measuring ΔH DN 65-150 Close the valve according to Shut-off, deactivate the Δp part according to Flushing. Connect TA Hydronics balancing instrument to the measuring points and measure. Important! The valve must be re-opened to previous setting and the Δp part activated after the measurement is completed. Flushing DN 65-150 H pv NOTE! Ensure that the actuator is disengaged from the valve spindle during all operating functions described above, except venting. 1. Release the fixing nut. 2. Turn the setting screw to fully open (position ). 3. Tighten the fixing nut. 4. Deactivate the Δp part by closing the flushing spindle fully (clockwise). After flushing, open the flushing spindle and set the valve to previous setting. 5

Valve characteristics DN 32-50 DN 65-150 q/q max [%] 0 90 80 70 60 50 40 30 20 0 0 20 30 40 50 60 70 80 90 0 h [%] q/q max [%] 0 90 80 70 60 50 40 30 20 0 0 20 30 40 50 60 70 80 90 0 h [%] Nominal valve characteristic for all recommended settings. Measuring accuracy Maximum flow deviation at different settings DN 32-50 DN 65-150 ± [%] ± [%] 18 18 16 16 14 14 12 12 8 8 6 6 4 4 2 2 0 0 0 20 30 40 50 60 70 80 90 0 *) 0 20 30 40 50 60 70 80 90 0 *) *) Setting (%) of fully open valve. Correction factors The flow calculations are valid for water (+20 C). For other liquids with approximately the same viscosity as water ( 20 cst = 3 E=0S.U.), it is only necessary to compensate for the specific density. However, at low temperatures, the viscosity increases and laminar flow may occur in the valves. This causes a flow deviation that increases with small valves, low settings and low differential pressures. Correction for this deviation can be made with the software TA Select or directly in TA Hydronics balancing instruments. 6

Noise In order to avoid noise in the installation the valve must be correctly installed and the water de-aerated. Closing force Necessary force (F) to close the valve versus the differential pressure (ΔpV), up to max. ΔpV. p [kpa] 400 DN 65-80 DN 0 DN 125 DN 150 350 300 250 200 DN 32-50 150 0 50 0 300 400 500 600 700 800 900 00 10 F [N] q max values Important: All values are provisional and may be subject to change. Please check the website for up-to-date information. Position 1 2 3 4 5 6 7 8 9 DN 32 880 1 030 1 220 1 450 1 750 2 200 2 580 3 150 3 770 4 300 DN 40 1 0 1 230 1 540 1 930 2 4 2 980 3 720 4 520 5 300 6 0 DN 50 2 580 3 130 3 750 4 450 5 450 6 400 7 550 8 650 000 900 Position 5.5 6 6.5 7 7.5 8 8.5 9 9.5 DN 65 4 950 5 8 6 820 8 0 9 440 11 200 13 400 16 200 19 900 25 200 DN 80 7 6 8 940 500 12 300 14 500 17 200 20 600 24 900 30 700 38 700 DN 0 14 000 16 500 19 400 22 800 26 900 31 800 38 000 46 000 56 700 71 600 DN 125 23 700 28 000 32 800 38 500 45 400 53 700 64 300 77 800 95 800 121 000 DN 150 39 200 46 200 54 200 63 600 75 000 88 800 6 200 128 600 158 400 200 000 q max = l/h at each setting and fully open valve plug. DN 65-150: Recommended setting range 7.5. 7

Sizing Example Flow is m 3 /h, available ΔpV is 20 kpa and control signal (input signal) is 0- VDC. 1. Go to sizing diagram. 2. Draw a straight horizontal line from m 3 /h, which will cross the setting bars for all valves which fit the application. In this case DN 50 setting 9,0, DN 65 setting 7,7. 3. Check that the available ΔpV is within the working range (between min. and max. allowed ΔpV). In this case, the ΔpV is 20kPa which is out of range for DN 65 (min. ΔpV=25 kpa valid for setting, other settings will require slightly lower ΔpV, this can be checked with the software TA Select). 4. Choose the smallest option (with some safety margin). In this case DN 50 is preferable. 5. Go to the selection tables to select the correct set. In this case article number 22202-0350. Sizing diagram 60 40 30 20 200 0 50 25 9 9 7,5 9 7,5 5,5 9 7,5 5,5 DN Differential pressure ΔpV [kpa] Min. Max. 32-50 15 350 65-80 25 400 0-125 30 400 150 40 400 5 2 1 5 7 7 4 9 7,5 5,5 7,5 5,5 5,5 0,5 2 7 4 4 1 0,2 1 1 0,5 l/s m 3 /h q max DN 32 40 50 65 80 0 125 150 DN 65-150: Recommended setting range 7.5. 8

Installation Application examples 2-way direct circuit Installation of actuator Approx. 140 mm of free space is required above the actuator. ~140 ~140 ~140 Injection circuit TA-FUSION-P Enclosure class Automatic operation: IP 54 (Manual operation TA-MC55: IP 30) Note: Read carefully the installation instruction of the actuator. Intended for indoor installation applications. For outdoor installation applications please contact TA Hydronics. In cooling systems, the pipe and valve must be insulated. DN 32-50 TA-FUSION-P DN 65-150 Normal pipe fittings Avoid mounting taps and pumps immediately before or after the valve. Installation recommendation for accurate measurement due to distortion of fully developed turbulent flow profile. 2D 5D 2D D Flow direction DN 32-50 DN 65-150 9

Actuators A wide range of high performance proportional actuators are available from TA Hydronics (e.g. 24V, 230V, fail safe) to provide accurate modulating or 3-point control, when used together with combined control and balancing valves. See Selection tables. For more details on actuators, see related technical leaflet TA-MC Actuators or contact TA Hydronics. Selection tables Valves and actuators are supplied together ensuring optimum control and simplified selection. The codes in the selection tables are for different sets of valve size (DN) and type of actuator. All fail safe and non-fail safe sets are able to close off (or fail safe open) against 0 max. ΔpV (350-400 kpa). For more details on actuators, see related technical leaflet TA-MC Actuators or contact TA Hydronics. Article number: 22202-xxxxxx To get the complete article number, simply add the code stated below according to your required set. Example: 22202-0332 Product codes in italics are with additional actuator functionalities. TA-MC55Y TA-MC55 TA-MC55 TA-MC0/160 3) TA-MC0/160 3) Input signal: 1) 0(2)- VDC / 0(2)- VDC / 0(2)- VDC / 3-point 3-point 0(4)-20 ma and 0(4)-20 ma and 0(4)-20 ma 3-point 3-point Output signal: 1) 0- VDC 0- VDC 0- VDC 0- VDC 0- VDC (0(4)-20 ma) 2) (0(4)-20 ma) 2) Supply voltage: 24 V 24 V 230 V 24 V 230 V Fail safe: No No No No No DN PN Flow range [m 3 /h] 32 16 0,88-4,30 0332 0132 0232 0432 0532 40 16 1,01-6, 0340 0140 0240 0440 0540 50 16 2,58 -,9 0350 0150 0250 0450 0550 65 16 9,40-25,2 032065 012065 022065 042065 052065 65 25 9,40-25,2 033065 013065 023065 043065 053065 80 16 14,5-38,7 032080 012080 022080 042080 052080 80 25 14,5-38,7 033080 013080 023080 043080 053080 0 16 26,9-71,6 - - - 0420 0520 0 25 26,9-71,6 - - - 0430 0530 125 16 45,4-121 - - - 042125 052125 125 25 45,4-121 - - - 043125 053125 150 16 75,0-200 - - - 062150 072150 150 25 75,0-200 - - - 063150 073150 Important: All values are provisional and may be subject to change. Please check the website for up-to-date information. 1) Invertable input and output signal 2) Output signal: 0(4)-20 ma on request (accessory), please contact TA Hydronics. 3) TA-MC160 required for sets with DN 150 only. DN 32-50: Female threaded DN 65-150: Flanged

With fail safe actuators Input signal: Output signal: TA-MC0 FSE TA-MC0 FSR TA-MC0 FSE TA-MC0 FSR 0(2)- VDC / 0(4)-20 ma and 3-point 0(2)- VDC 0(4)-20 ma 0(2)- VDC / 0(4)-20 ma and 3-point 0(2)- VDC 0(4)-20 ma 3-point 3-point 0- VDC 0- VDC Supply voltage: 24 V 24 V 230 V 230 V Fail safe: DN PN Flow range [m 3 /h] Extending (closing) Retracting (opening) Extending (closing) Retracting (opening) 32 16 0,88-4,30 0832 0932 32 1132 40 16 1,01-6, 0840 0940 40 1140 50 16 2,58 -,9 0850 0950 50 1150 65 16 9,40-25,2 082065 092065 2065 112065 65 25 9,40-25,2 083065 093065 3065 113065 80 16 14,5-38,7 082080 092080 2080 112080 80 25 14,5-38,7 083080 093080 3080 113080 0 16 26,9-71,6 0820 0920 20 1120 0 25 26,9-71,6 0830 0930 30 1130 125 16 45,4-121 082125 092125 2125 112125 125 25 45,4-121 083125 093125 3125 113125 150* 16 75,0-200 - - - - 150* 25 75,0-200 - - - - Important: All values are provisional and may be subject to change. Please check the website for up-to-date information. *) For DN 150 with fail safe actuator, please contact TA Hydronics. DN 32-50: Female threaded DN 65-150: Flanged Selection tables individual components The valve and actuator sets detailed previously ensure optimum control and simplified selection and are therefore the recommended option. Under certain circumstances however, for example when delivery to site is required on different dates, the individual set components may be ordered using the following table; DN PN Article No Article No Adapter for actuator (for individual valve) TA-MC55Y/TA-MC55 TA-MC0 TA-MC160 TA-MC0 FSE/FSR 32 16 22202-0032 n. a. 22412-10 40 16 22202-0040 n. a. 22412-10 50 16 22202-0050 n. a. 22412-10 65 16 22202-002065 22413-0055 22413-0010 n. a. 22413-10 65 25 22202-003065 22413-0055 22413-0010 n. a. 22413-10 80 16 22202-002080 22413-0055 22413-0010 n. a. 22413-10 80 25 22202-003080 22413-0055 22413-0010 n. a. 22413-10 0 16 22202-0020 n. a. 22413-0010 n. a. 22413-20 0 25 22202-0030 n. a. 22413-0010 n. a. 22413-20 125 16 22202-002125 n. a. 22413-0010 n. a. 22413-20 125 25 22202-003125 n. a. 22413-0010 n. a. 22413-20 150 16 22202-002150 n. a. n. a. 22413-001160 FSE on request FSR n. a. 150 25 22202-003150 n. a. n. a. 22413-001160 FSE on request FSR n. a. = Adapter supplied together with the valve. n.a. = Not applicable. 11

Articles DN 32-50 Female threads 0(2)- VDC / 0(4)-20 ma, 24 V (TA-MC55Y) ~140 ØD2 DN d D D1 D2 L1 L2 H1* H2 Kg EAN Article No ØD ØD1 H1* H2 32 G1 1/4 130 128 9 213 333 186 326 8,0 5901688821329 22202-0332 40 G1 1/2 130 128 9 218 332 186 326 8,0 5901688821350 22202-0340 50 G2 130 128 9 226 340 190 330 8,5 5901688821381 22202-0350 d 3-point, 24 V (TA-MC55) L1 L2 DN d D D1 D2 L1 L2 H1* H2 Kg EAN Article No 32 G1 1/4 130 128 9 213 333 186 326 8,0 5901688821305 22202-0132 40 G1 1/2 130 128 9 218 332 186 326 8,0 5901688821336 22202-0140 50 G2 130 128 9 226 340 190 330 8,5 5901688821367 22202-0150 3-point, 230 V (TA-MC55) DN d D D1 D2 L1 L2 H1* H2 Kg EAN Article No 32 G1 1/4 130 128 9 213 333 186 326 8,0 5901688821312 22202-0232 40 G1 1/2 130 128 9 218 332 186 326 8,0 5901688821343 22202-0240 50 G2 130 128 9 226 340 190 330 8,5 5901688821374 22202-0250 0(2)- VDC / 0(4)-20 ma and 3-point, 24 V (TA-MC0) 1) ØD1 ~140 ØD2 H2 DN d D D1 D2 L1 L2 H1* H2 Kg EAN Article No 32 G1 1/4 130 128 3 213 380 186 398 9,0 5901688821398 22202-0432 40 G1 1/2 130 128 3 218 380 186 398 9,0 5901688821411 22202-0440 50 G2 130 128 3 226 384 190 402 9,5 5901688821435 22202-0450 ØD H1* 0(2)- VDC / 0(4)-20 ma and 3-point, 230 V (TA-MC0) 1) d DN d D D1 D2 L1 L2 H1* H2 Kg EAN Article No L1 L2 32 G1 1/4 130 128 3 213 380 186 398 9,0 5901688821404 22202-0532 40 G1 1/2 130 128 3 218 380 186 398 9,0 5901688821428 22202-0540 50 G2 130 128 3 226 384 190 402 9,5 5901688821442 22202-0550 *) Height to the spindle top (for threaded valves). 1) Actuators with additional functionalities, such as position switches, output signal 0(4)-20 ma, see related technical leaflet TA-MC Actuators. = Flow direction Actuators in all sets are sized for actuation up to max. ΔpV. Valve and actuator are individually packaged for easy handling on site. 12

~140 DN 65-150 With flanges 0(2)- VDC / 0(4)-20 ma, 24 V (TA-MC55Y) ØD1 H 65 185 290 290 339 47 5901688821626 22202-032065 80 200 290 3 339 54 5901688821718 22202-032080 65 185 290 290 339 47 5901688821657 22202-033065 80 200 290 3 339 54 5901688821749 22202-033080 ØD 3-point, 24 V (TA-MC55) L 65 185 290 290 339 47 5901688821602 22202-012065 80 200 290 3 339 54 5901688821695 22202-012080 65 185 290 290 339 47 5901688821633 22202-013065 80 200 290 3 339 54 5901688821725 22202-013080 3-point, 230 V (TA-MC55) 65 185 290 290 339 47 5901688821619 22202-022065 80 200 290 3 339 54 5901688821701 22202-022080 65 185 290 290 339 47 5901688821640 22202-023065 80 200 290 3 339 54 5901688821732 22202-023080 0(2)- VDC / 0(4)-20 ma and 3-point, 24 V (TA-MC0) 1) ~140 ØD1 ØD H 65 185 290 290 438 48 5901688821770 22202-042065 80 200 290 3 438 55 5901688821831 22202-042080 0 220 3 350 438 62 5901688822135 22202-0420 125 250 344 400 438 85 5901688822197 22202-042125 65 185 290 290 438 48 5901688821794 22202-043065 80 200 290 3 438 55 5901688821855 22202-043080 0 235 3 350 438 62 5901688822159 22202-0430 125 270 344 400 438 85 59016888222 22202-043125 L 0(2)- VDC / 0(4)-20 ma and 3-point, 230 V (TA-MC0) 1) 65 185 290 290 463 48 5901688821787 22202-052065 80 200 290 3 463 55 5901688821848 22202-052080 0 220 3 350 463 62 5901688822142 22202-0520 125 250 344 400 463 85 5901688822203 22202-052125 65 185 290 290 463 48 5901688821800 22202-053065 80 200 290 3 463 55 5901688821862 22202-053080 0 235 3 350 463 62 5901688822166 22202-0530 125 270 344 400 463 85 5901688822227 22202-053125 13

0(2)- VDC / 0(4)-20 ma and 3-point, 24 V (TA-MC160) 1) ~140 ØD1 H 150 285 380 480 533 121 5901688822258 22202-062150 150 300 380 480 533 121 5901688822272 22202-063150 0(2)- VDC / 0(4)-20 ma and 3-point, 230 V (TA-MC160) 1) ØD L 150 285 380 480 558 121 5901688822265 22202-072150 150 300 380 480 558 121 5901688822289 22202-073150 1) Actuators with additional functionalities, such as position switches, output signal 0(4)-20 ma, see related technical leaflet TA-MC Actuators. = Flow direction Actuators in all sets are sized for actuation up to max. ΔpV. Valve and actuator are individually packaged for easy handling on site. 14

Articles Fail-safe, extending (closing) DN 32-50 Female threads 0(2)- VDC / 0(4)-20 ma and 3-point, 24 V (TA-MC0FSE) ~140 DN d D D1 L1 L2 L3 H1* H2 Kg EAN Article No ØD1 L3 H2 32 G1 1/4 130 128 213 379 141 186 356 9,3 5901688821459 22202-0832 40 G1 1/2 130 128 218 379 141 186 356 9,3 5901688821497 22202-0840 50 G2 130 128 226 383 141 190 360 9,8 5901688821534 22202-0850 ØD H1* 0(2)- VDC / 0(4)-20 ma and 3-point, 230 V (TA-MC0FSE) d DN d D D1 L1 L2 L3 H1* H2 Kg EAN Article No L1 L2 32 G1 1/4 130 128 213 379 141 186 356 9,3 5901688821473 22202-32 40 G1 1/2 130 128 218 379 141 186 356 9,3 59016888215 22202-40 50 G2 130 128 226 383 141 190 360 9,8 5901688821558 22202-50 *) Height to the spindle top (for threaded valves). ~140 DN 65-150 With flanges 0(2)- VDC / 0(4)-20 ma and 3-point, 24 V (TA-MC0FSE) L ØD1 ØD H 65 185 290 290 382 48 5901688821916 22202-082065 80 200 290 3 382 55 5901688822036 22202-082080 0 220 3 350 382 62 5901688822333 22202-0820 125 250 344 400 382 85 5901688822456 22202-082125 65 185 290 290 382 48 5901688821954 22202-083065 80 200 290 3 382 55 5901688822074 22202-083080 0 235 3 350 382 62 5901688822371 22202-0830 125 270 344 400 382 85 5901688822494 22202-083125 0(2)- VDC / 0(4)-20 ma and 3-point, 230 V (TA-MC0FSE) 65 185 290 290 382 48 5901688821930 22202-2065 80 200 290 3 382 55 5901688822050 22202-2080 0 220 3 350 382 62 5901688822357 22202-20 125 250 344 400 382 85 5901688822470 22202-2125 65 185 290 290 382 48 5901688821978 22202-3065 80 200 290 3 382 55 5901688822098 22202-3080 0 235 3 350 382 62 5901688822395 22202-30 125 270 344 400 382 85 5901688822517 22202-3125 DN 150 with fail safe actuator, please contact TA Hydronics. = Flow direction Actuators in all sets are sized for actuation up to max. ΔpV. Valve and actuator are individually packaged for easy handling on site. 15

Articles Fail-safe, retracting (opening) DN 32-50 Female threads 0(2)- VDC / 0(4)-20 ma and 3-point, 24 V (TA-MC0FSR) ~140 DN d D D1 L1 L2 L3 H1* H2 Kg EAN Article No ØD1 L3 H2 32 G1 1/4 130 128 213 379 141 186 356 9,3 5901688821466 22202-0932 40 G1 1/2 130 128 218 379 141 186 356 9,3 5901688821503 22202-0940 50 G2 130 128 226 383 141 190 360 9,8 5901688821541 22202-0950 ØD H1* 0(2)- VDC / 0(4)-20 ma and 3-point, 230 V (TA-MC0FSR) d DN d D D1 L1 L2 L3 H1* H2 Kg EAN Article No L1 L2 32 G1 1/4 130 128 213 379 141 186 356 9,3 5901688821480 22202-1132 40 G1 1/2 130 128 218 379 141 186 356 9,3 5901688821527 22202-1140 50 G2 130 128 226 383 141 190 360 9,8 5901688821565 22202-1150 *) Height to the spindle top (for threaded valves). ~140 DN 65-125 With flanges 0(2)- VDC / 0(4)-20 ma and 3-point, 24 V (TA-MC0FSR) L ØD1 ØD H 65 185 290 290 382 48 5901688821923 22202-092065 80 200 290 3 382 55 5901688822043 22202-092080 0 220 3 350 382 62 5901688822340 22202-0920 125 250 344 400 382 85 5901688822463 22202-092125 65 185 290 290 382 48 5901688821961 22202-093065 80 200 290 3 382 55 5901688822081 22202-093080 0 235 3 350 382 62 5901688822388 22202-0930 125 270 344 400 382 85 5901688822500 22202-093125 0(2)- VDC / 0(4)-20 ma and 3-point, 230 V (TA-MC0FSR) 65 185 290 290 382 48 5901688821947 22202-112065 80 200 290 3 382 55 5901688822067 22202-112080 0 220 3 350 382 62 5901688822364 22202-1120 125 250 344 400 382 85 5901688822487 22202-112125 65 185 290 290 382 48 5901688821985 22202-113065 80 200 290 3 382 55 59016888224 22202-113080 0 235 3 350 382 62 5901688822401 22202-1130 125 270 344 400 382 85 5901688822524 22202-113125 = Flow direction Actuators in all sets are sized for actuation up to max. ΔpV. Valve and actuator are individually packaged for easy handling on site. 16

Accessories L d Measuring points For DN 65-150. d L EAN Article No M14x1 44 7318792813207 52 179-014 M14x1 3 73187938588 52 179-015 d L Extension for measuring point M14x1 Suitable when insulation is used. For DN 65-150. d L EAN Article No M14x1 71 7318793969507 52 179-016 d Measuring point Extensions 60 mm. Can be installed without draining of the system. For all dimensions. L EAN Article No 60 7318792812804 52 179-006 Tamper proof ring For locking of set Kv max. For DN EAN Article No 32-50 7318794001800 227-000001 Identification tag EAN Article No 7318794001701 227-000002 Insulation See related insulation instruction under Products & Solutions on www.tahydronics.com or contact TA Hydronics. Actuators accessories See related technical leaflet TA-MC Actuators or contact TA Hydronics. 17

18

19