LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS Dimensions in accordance with DIN 43 62 Live tags Top indicator Lead free contact blades % cadmium APPLICATIONS gg: General purpose (protection of cables and LV-networks) The NH system is classified among plug-in fuse systems and is composed of: fuse-base (possibly including terminal covers and phase barriers) fuse-link with blade contact fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type gg NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents. TECHNICAL DATA OVERVIEW Voltage AC 5 VAC Voltage DC 25 VDC Ampere Range (A) 4... 16 A Size per Standard 4, 4a Speed/Characteristic gg I.R. AC (IEC) 12 ka I.R. DC (IEC) 7 ka Body Material ceramic Contact Materials copper, silver-plated STANDARDS IEC/EN 6269-1 and -2 VDE 636 Part 21 EP.MERSEN.COM 1
PRODUCT RANGE Size 4 gg 5VAC top indicator Catalog Item AC (IEC) DC (IEC) Rated current In Power dissipation at In Width Package Weight NH4GG5V125-8 NH4GG5V63-8 X134514 5 V 25 V 63 A 38 W 1 mm 1 2.59 kg NH4GG5V8-8 Y134515 5 V 25 V 8 A 56 W 1 mm 1 2.59 kg NH4GG5V-8 Z134516 5 V 25 V A 65 W 1 mm 1 2.59 kg NH4GG5V125-8 A134517 5 V 25 V 125 A 61 W 1 mm 1 2.59 kg Size 4a gg 5VAC top indicator Catalog Item AC (IEC) DC (IEC) Rated current In Power dissipation at In Width Package Weight NH4AGG5V16-8 NH4AGG5V4-8 B134518 5 V 25 V 4 A 31 W 98 mm 1 2.59 kg NH4AGG5V5-8 C134519 5 V 25 V 5 A 45 W 98 mm 1 2.59 kg NH4AGG5V63-8 D13452 5 V 25 V 63 A 47 W 98 mm 1 2.59 kg NH4AGG5V8-8 F134522 5 V 25 V 8 A 67 W 98 mm 1 2.59 kg NH4AGG5V-8 H134524 5 V 25 V A 69 W 98 mm 1 2.59 kg NH4AGG5V125-8 J134525 5 V 25 V 125 A 84 W 98 mm 1 2.59 kg NH4AGG5V16-8 K134526 5 V 25 V 16 A 16 W 98 mm 1 2.59 kg TECHNICAL DATA size 4 size 4a Rated current 63... 125 A 4... 16 A Rated breaking capacity AC 12 ka 12 ka AC 5 V 5 V DC 25 V 25 V Indication System top indicator top indicator Width 1 mm 1 mm EP.MERSEN.COM 2
TIME CURRENT CHARACTERISTIC CURVES Size 4, 63-125A Size 4a, 4-16A 7 5 3 2 Pre-arcing time (s) 7 5 3 2 1 7 5 3 2 1 7 5 3 2 63 A 8 A A 125 A 1 16 A.7.5.3.2.1.7.5.3.2.1.7.5.3.2.1.7.5.3.2.1 5 7 2 3 5 7 2 3 5 RMS value of prospective current (A) +/- 8% 7 2 3 5 EP.MERSEN.COM 3
CUT-OFF CURRENT CHARACTERISTIC Size 4, 63-125A Size 4a, 4-16A 3 2 lm = 2.3 lp 16 A 125 A Maximum peak let thru current Ic (A) 7 5 3 2 2 3 5 7 2 3 5 7 2 5 Hz RMS symmetrical prospective current Ip (A) A 8 A 63 A 5 A 4 A 3 5 5e+6 7 1e+6 PRE-ARCING AND OPERATING I²T CHARACTERISTICS Size 4, 63-125A Size 4a, 4-16A Pre-arcing and operating I²t (A²s) 1 7 5 3 2 1 7 5 3 2 1 7 5 3 2 1 5V 4V pre-arcing I²t Rated current (A) 4 5 63 8 125 16 EP.MERSEN.COM 4
DIMENSIONS Size 4 with top indicator Indicator lever visible when the fuse has blown 68.5 ±1.4 62.5 ±1.4 22 1 6 (9) 32 ±.4 5 ±.2 87 1 ± 1.8 1 3 16 ±.4 16 ±.4 2 3.6 (79.5) 3.6 1 ±1.8 +2 149.5-1.6 8 ±.1 +2 199.5-1.6 Dimensions in mm EP.MERSEN.COM 5
DIMENSIONS Size 4a with top indicator Indicator lever visible when the fuse has blown 3 1 -.3 (51) 1 -.3 6 -.3 3 -.3 9 28.5 83 ± 1.4 91 ± 1.4 19-4 85 (51) 1-4 6 ±.1 Dimensions in mm 5 ±.2 +1 2-2.4 EP.MERSEN.COM 6