USER MANUAL. Item: #13246 Stand-Aid Lift. Drive Medical Design and Manufacturing

Similar documents
USER MANUAL. Item: #13246 Stand-Aid Lift. Drive Medical Design and Manufacturing Push Handle. Base Width Adjustment Handle.

atient lifters Assembly, Maintenance & Specifications Manual SUNRISE HML400 Hoyer Manual Patient Lift HPL400 Hoyer Power Patient Lift Sunrise Medical

BATTERY OPERATED PATIENT LIFT MODEL:650HD OWNER S MANUAL

ATLAS SIT-TO-STAND LIFT

DOC /500/600 Series Patient Lift Owner's Manual REV 001

A205 Patient Lifter - Aluminium USER MANUAL

The Future of Homecare Lifting is Here!

DOC /500/600 Series Sit to Stand Lift Owner's Manual REV 001

Floor Lifts. We re the company that brings you. next generation of mobile lifts. Toll Free:

Ensure the product has been assembled according to the instructions in this manual.

BESTLIFT. FULL BODY PATIENT LIFT Model: PL500HE

BATTERY OPERATED PATIENT LIFT MODEL: 650HD OWNER'S MANUAL

A200S Patient Stander - Aluminium USER MANUAL

SONATA 150 ELS MOBILE PATIENT LIFTING HOIST USER MANUAL IMPORTANT:

Ensure the product has been assembled according to the instructions in this manual.

All-in-One Hoist User Manual , , ,

Competitor. Ultra Light Plus, Semi Electric Bed. Item # Owner s Assembly And Operating Manual

SGA-440 by Prism Medical

Liko M220 / Liko M230

FGSH-450 by Prism Medical

180 kg yoke or pivot diagnostic

Pallas/150. Stand-aid lifter. User instruction. Important - information. This user instruction must be read before the Pallas 150 is used.

Competitor. Ultra Light Plus, Semi Electric Bed. Item # 15560, HR Owner s Assembly And Operating Manual

U S E R M A N U A L. To avoid injury, read user manual prior to use. enablelifecare.com.au. Hoyer Journey. Joerns Hoyer Presence

320 kg yoke diagnostic

Stand Up Patient Lift RPS350-1

Roze Stand Up Patient Lift

Easy Lift Patient Lifting System

LF2020 EASY LIFT SIT-TO-STAND LF2090 BARIATRIC EASY LIFT SIT-TO-STAND

Graduate 150 Scholar 175 Master 200

BRIANA: Bedside Lift MODEL:BSL220. ALTON: Bathtub Lift MODEL:BTL330. The Future of HomeCare Lifting is Here!

SONATA 150 Mobile Lifting Hoist Instruction & Safety Manual

Competitor. Ultra Light Plus, Semi Electric Bed. Item # Owner s Assembly And Operating Manual

U S E R M A N U A L. To avoid injury, read user manual prior to use. enablelifecare.com.au. Joerns Hoyer Presence

Prism A-205. Owner s Manual. Aluminium Mobile Hoist. Use and Care Trouble Shooting Warranty Information. Introduction Overview...

Instruction manual. RP800 - HYDRAULIC actuator, load 150Kg. RP815 - LINAK actuator, load 150Kg

LF1090 BARIATRIC PATIENT LIFT

Electric Portable Patient Lift

INSTRUCTIONS AND WARRANTY FOR THE STAND AID MODEL 1501 STAND AID SERIAL #

Electric Portable Patient Lift - RPA600-1E

Free Standing Track. Owner s Manual. Use and Care Trouble Shooting

SARA PLUS THE ADVANCED STANDING AND RAISING AID

R710. R710 Product Manual

User Instruction Manual Hoyer. HPL700 and HPL700WSC To avoid injury, read user manual prior to use.

New Products offering 2014

Ultralift 3510/7510 Series

INSTRUCTIONS AND WARRANTY FOR THE STAND AID MODEL 1501 STAND AID SERIAL #

Unihoist Ltd. Range of Electric & Hydraulic Hoists

ALTO LIFT 200 Mobile Patient Lifting Hoist Instruction & Safety Manual

Invacare Reliant 450 RPL450-2 Invacare Reliant 600 RPL600-2

Invacare Reliant 450 RPL450-2 Invacare Reliant 600 RPL600-2

M Series Mobile Lift. User Manual. 45 Progress Parkway, Maryland Heights, MO 63043, USA. M-Series User Manual Rev 10JAN2012 Page

Oxford. Manufacturer s Contact Details. Contents. Oxford Presence. English

Visual inspection Inspect lift functions regularly. Check to ensure that material is free from damage.

Overhead lift Roomer 5200

HEARTWAY MEDICAL PRODUCTS CO., LTD. Part no:

User Guide Manual del usuario

Pro Battery-Powered Floor Lift

SARA PLUS INSTRUCTIONS FOR USE

Viking M / Viking L / Viking XL

Voyager Portable. Oxford. Key features. High performance portable lifting solutions

READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

EZ Way Shower Trolleys

Oxford /Hoyer. Journey User Instruction Manual & Warranty. Journey Manuel de l utilisateur et garantie

adult Kanga TS wheelchair

Freedom Rollator. By Medline

Owner s Manual. Transport / Companion Wheelchairs M4TV M2TF M2TC M2TL HEALTH PRODUCTS, INC.

User Manual. Use and Care Fault Finding Warranty Information. Unit 1, Tir Llwyd Industrial Estate, St Asaph Avenue, Kinmel Bay, Rhyl, Conwy, LL18 5JZ

190/195 Tilt Shower Commode User Manual

Rehab Shower Commodes

READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

Wallaby Wheelchair. Item #s: WB1200-2GFR, WB1400-2GJB. Accessories WB ELR - Elevating Leg Rests WB Headrest Extension STDS833N - Anti-Tippers

Rehab Shower Commodes

Apollo Tilt Wheelchair 18" and 20" Instruction Manual

Owner s Manual. Bariatric Manual Wheelchairs. Specializing in Bariatric Patient Aids

Item #s: D577-R, D577-J, D577-BR IMPORTANT SAFETY GUIDELINES

Heavy Duty Engine Cranes

User Instruction Manual Hoyer. Manuel de l utilisateur Hoyer. Manual de Instrucciones Hoyer. Elevate. Elevate. Elevate

K710 Product Manual. Support Station. K710 Product Manual

Hoyer. Ascend User Instruction Manual & Warranty. Hoyer. Hoyer. Ascend Manuel de l utilisateur et garantie. Hoyer

GB/US... GLS5 Active lifter. User manual - vers. 4.00

Advancement Chair. R901, R902, & R903 Product Manual

High-Rise Tire Dolly

GB/US... GL5 mobile lifter. User manual - vers. 1.00

Breezy EC Transport Wheelchair

GL5 GLS5. Floor Lifters

Supplying Hospitals for Over 90 Years. User Guide MDS86825SLR. Ultra-Light Rollator

Engine Crane Owner s Manual

9' Warm White /Multi LED Color Changing M5 One Plug tree V INSTRUCTION MANUAL

Opera. Operating and Product Care Instructions KPX GB KKX GB/2. Jan. 2001

QUICKIE 5 R Quick Guide. IMPORTANT! Read all Warnings and Instructions contained in the complete Owner s Manual prior to using this product.

MAXI LITE Instruction for Use

Prime Engineering GRANSTAND II

Operating and Product Care Instructions KPX GB KKX GB/2. November 2003

aks-goliath Operating manual (translation of the original operating manual)

Bio Lion Table Top Centrifuge XC-L5

Heavy Duty Four Wheeled Walker

Introduction. Components. Do the following

AQUATEC R / AQUATEC F / AQUATEC XL. Bathlift Operating instructions

INVACARE Birdie PATIENT LIFTERS

Transcription:

USER MANUAL Item: #13246 Stand-Aid Lift

IMPORTANT SAFEGUARDS Your lift is for transferring patients only. Do not use the lift for any other purpose. Stand-Aid Lift is intended to be used for persons within the specified weight limit indicated for the lift. Do not attempt to lift more than the weight limit indicated. Before attempting to transfer, the user must be assessed by a qualified professional. The lift must be used by a caregiver with proper training to work with the person to be transferred. Only trained and qualified caregivers should transfer a person. Do not attempt to use the lift if you have not been properly trained to do so. Always be prepared before attempting to transfer a person. Do not use a sling that is not recommended for the lift. Do not store the lift in a shower, bath or other area with high humidity. Keep all components of the lift clean and dry and have electrical and mechanical safety. Always maneuver the lift with the handle provided.

ASSEMBLY INSTRUCTIONS 1. Remove all the parts from the carton and place on the floor, taking care to protect the finish from damage. 2. Place the chassis in a clear space and apply the rear bakes. Attach the foot plate to the base.

3. Fit the mast and boom" assembly into the base socket. Tighten the mast assembly with the drive screw.

Tighten up screw Assemble actuator bottom and top. Insert the pin chain through actuator top.

Fit control box onto bracket (on mast). Tight up control box. Fit battery onto control box.

Plug the hand set in control box bottom at left side. Plug actuator in control box bottom at middle. Fit the adjusting handle. REMARKS: Please always check the mast is fully locked into position.

I. How to Operate the Stand-Aid Lifter: (Weight Lifting Capacity: 180 kgs) Important: Prior to first use, please make sure that the battery is being charged 24 hours in order to reach proper function and prolong the lifetime of battery. 1. Spread the base legs to the widest position before lifting. 2. Keep the patient centered between the base legs and have the patient face the attendant. 3. Be extremely cautious and use restraint straps for spastic or severely handicapped patients. 4. How to use Standard or Commode Slings: a. For smooth and easy lifting, have the lift, chains, sling, commode or wheelchair in ready position. b. With the patient in center of bed, roll on side away from the attendant. c. Roll the patient to side toward the attendant and center the patient on sling. With base of lifter under bed, press the button on the control handset to lower the boom (#20). d. Hook the hanging strips of sling with the hanging bar carefully. If a chain is used, make sure the S hooks are away from the patient. e. Lock rear casters, lift the patient by pressing the button on the control handset. f. Lift patient until his or her feet will swing easily off the bed keeping patient facing the attendant. g. Unlock rear casters and transfer patient to and above commode or wheelchair. Lock brakes of both lifter and commode (or wheelchair). h. Press the button on the control handset to gradually lower the patient. i. During descent, assist patient to attain correct sitting posture. j. For transferring to wheelchair, when patient is seated, push down on boom to slacken hanging strips of sling. Patient can remain seated in sling. k. For commode use, adjust clothing before moving lift to straddle commode. Keep hanging strips taut and make sure patient is in a comfortable position. Trouble Shooting (Linak LA34 System) Normal Symptom Possible Cause Action Power indicator does not light Not connected to mains Connect to mains up. The fuse has blown Replace fuse, if the system is prepared for external Power indicator lights up Control box defective fuse replacement, or send the system to repair Send control box to repair Actuator plug not pushed into Push actuator plug into But actuator does not run. control properly control box properly Relays in control box are Actuator defective Replace actuator heard clicking. Control box defective Replace control box. Power indicator lights up Control box defective Send control box repair but actuator does not run. Handset defective send handset repair No relay noise is heard Handset plug not insert properly Check all cord connections from control box. Emergency stop engaged Deactivate emergency stop

Charger plugged in Unplug charger Control box completely dead Battery completely flat Charge battery on battery and no relay Battery defective Replace battery clicking is heard. Control box okay apart from handset defective Send handset for repair One direction on one channel Control box defective Send control box for repair Warning and Caution! 1. Patient lifter is a Transfer Device that allows patient attendant to transfer patients from bed to wheelchair or commode etc. It however should not be used to transport patients. 2. When lifting patient, make sure the base legs are in the most widely opened position and the rear caster brakes are engaged. Otherwise, the lifter may tilt over. 3. When battery power is 50% low, the controller will give beep warning. At this moment, you should charge the battery immediately. Please note that a lifted patient cannot be lowered down when battery is out of power. 4. Push the Emergency red button if the control unit system is out of control. 5. QUICK RELEASE system (push/pull) enables stepless retraction of the actuator under load (Mechanical emergency lowering). Refer to Picture A. Picture A: QUICK RELEASE 6. How to Charge: (please refer to Picture B ) a. With Jumbo Linak set (battery box, control box & actuator) assembled, insert the power cord plug in control box and the other end to a wall outlet. b. Now, it is charging, the Charge light is on. c. When the charging action is finished, the Charge light will be off automatically. (Usually, it is need to charge 4 hours from the 50% capacity to 100% capacity) d. Remove the power supply cord. e. Now, you can operate again.

PICTURE B: Battery box Control box with internal charger Emergency stop button Connect the plug of Handset LCD display Connect the plug of Actuator Insert the plug of power cord in control box and the other end to a wall outlet.. Maintenance: It is extremely important that the lift be inspected before each use. The following items need to be checked: a. All nuts and bolts should be tight. b. The lifter should move freely with caster brakes off. c. Check the brakes on the rear casters for proper operation. d. Make sure base adjustment mechanism is operating easily. e. Double check to ensure the U bracket at the end of the boom and the S hook on the hanging bar are secured tightly. f. Work the Linak Actuator to ensure that the battery still has enough power. When battery is 50% below full capacity, it will give beep warning and need to re-charge immediately. g. Before initial use, place a drop of oil on the following areas. (1) Where mast and boom connect, hanging bar hook, pump handle hinge, and caster axles, (2) Where pump and boom attach, (3) Lubricate as above every two to three months. * We reserves the right to make technical changes without notice Manufactured For:

Drive Medical Design & Manufacturing 99 Seaview Boulevard Port Washington, NY 11050 Phone: 516-998-4600 Fax: 516-998-4601