SEALED PLATINUM SURFACE TEMPERATURE SENSOR MODEL 29399

Similar documents
General Information... Temperature/Resistance Table... Part Numbering Examples for RTD s. High Temperature MgO Elements (RA)...

ENGLISH Datasheet Platinum Resistance Pt100 4 wire class B Resistance Thermometer with Compact KNS Head

Platinum Temperature Sensors 1/16

SECTION 8: STATOR WINDING SENSORS

For the plastics machinery industry Fixed bayonet thermocouple Model TC47-FB

SECTION 7: MINIATURE SENSORS

For the plastics machinery industry Adjustable bayonet thermocouple Model TC47-AB

RAPID SHIP SENSORS, STOCK WIRE

For the plastics machinery industry Manifold thermocouple Model TC47-MT

Thermocouples W A T L O W

Data sheet. Connection cable M12 jack straight - free line end 8-pole, X-coded 0.5 m. Illustrations P/N 142M2X20005 EAN

Introduction to Heat Trace Cable Systems

NTC Thermistors. Vishay FEATURES. Custom designed executions Application specific leads, housings, and connectors. NTC Thermistors Screw terminal

series S01 (usually CLOSED)

FISCHER FREEDOM TM SERIES

Thermocouples W A T L O W

Electronic Temperature Sensor

Specification for Heated Instrument Tubing in Process Applications* (March 29, 2007)

CABLES FOR AUTOMOTIVE MARKET Sensor and multimedia cables. Catalogue

PPT 802, Proximity Probe Transducer System

REVISIONS SYMBOL DESCRIPTION DATE APPROVAL

120/240 Volts 3 Watt Floor Heating Cable System

K CHAPTER FREEDOM TM SERIES EASY MATING EASY CLEANING EASY INTEGRATION FISCHER KEY FEATURES

ICT TRANSFORMERS. Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices

Thermocouples. General Applications Tube and Wire. Thermal Devices, Inc. Mount Airy, Maryland USA

Thermocouples. General Applications Tube and Wire. Performance Capabilities. Features and Benefits. Typical Applications. Construction and Tolerances

Industrial Control Transformers

Hydro-Flow Model 3100

Temperature Sensors. NTC Thermistors. Descriptions. RTS-Raw 10K NTC Thermistor. Specifications: Dimensions (mm):

NTC Thermistor Assemblies

Wire. Litz. components need a dependable source for Litz. wire of the highest quality. New England Wire Technologies

Hot Runner Thermocouples Model TC46

Hydro-Flow Model 3100 Retractable Insertion Vortex Flowmeter Installation and Operation Manual

INDUSTRIAL TAPE PRODUCT GUIDE

Platinum-chip Temperature Sensors in SMD Design Type According to DIN EN 60751

Temperature Coefficient of Resistance Temperature Coefficient of Resistance, Tracking Maximum Operating Voltage Insulation Resistance

Type LT Self-Regulating Heater Cable For use in Ordinary and Hazardous (Classified) Locations

CABLED TWISTED PAIRS CONDUCTORS

Mineral Insulated Resistance Thermometers (RTD)

Weed Model N9355. Direct Immersion RTD. Nuclear Qualified

N I S T traceable calibration equipment conforms to MIL-STD-45662A.

TS Temperature Sensor and Transducers. Product Bulletin. Wide range of mounting types and signal outputs

THERMOCOUPLE AND RESISTANCE THERMOMETER CABLES

Data sheet Connection line M12 plug straight - RJ45 plug straight 8-pole, X-coded 5.0 m

Solid PE Insulated & LAP Sheathed Air Core/Jelly Filled Cables to DIN VDE 0816

DATA SHEET NTC thermistors, accuracy line. BCcomponents

Data sheet CFBUS.PVC PVC - e-chain - Bus cable for medium load requirements (class 4.3.2): shielded, oil-resistant as well as flame-retardant.

Type LT Self-Regulating Heater Cable For use in Ordinary (Unclassified) and Hazardous (Classified) Locations

Temperature Sensors. Description. Specification

C Power Connection Kit

OEM Pressure Transmitters

TIDALFLUX 2300 F Quick Start

NTC thermistors, high-temperature sensors /7/8...

TEMPERATURE SENSORS TEMPERATURE SENSORS

GROUNDING & BONDING PRODUCTS

HUMIDITY / TEMPERATURE TRANSMITTER

WW25N ±1%, ±5%, 2W Ultra low ohm power chip resistors Size 2512 (6432)

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated

NEC 2014 Code Changes

TE-6300 Series Temperature Sensors

NTC Accurate Thermistors

Nuheat WEATHER-READY HEAT TRACE PIPE FREEZE PROTECTION SYSTEM. Self-Regulating Heating Cable Installation Guide. UV Resistant Polyolefin Outer Jacket

Current Switches and Transducers

Hydro-Flow Model 2200 Fixed Insertion Vortex Flowmeter Installation and Operation Manual

Type HLT Self-Regulating Heater Cable For use in Ordinary and Hazardous (Classified) Locations

A. General: Deliver, store and handle wire and cable in accordance with the manufacturer's instructions and as specified in Division 1.

Submersible Averaging Duct Transmitters BA/T#SA Temperature Transmitter Installation & Operations

RTD and Thermocouple Assemblies Reference Manual

LIMIT SWITCH Hawkeye - HX Magnetic Solid State Proximity Sensors Installation, Maintenance and Operating Instructions (HX )

Hydro Stator End Winding Accelerometer System

RSK Connectors and Installation Tools

SLC-811X Series. Single Loop Proportional Temperature Controller General Instructions APPLICATION SPECIFICATIONS

Power Connection Kit installation instructions

Hydro-Flow 2200 Fixed Insertion Vortex Flow Meter

PUR c-track cables For highest requirements

Measurement Type Non-Contact Proximity, Capacitive Technology

Hydro Stator End Winding Accelerometer System

TE-6300 Series Temperature Sensors

3M Connector System 0.050" x 0.100" Pitch. 3M Tripolarized Wiremount Socket - Series 820 3M 4-Wall, Tripolarized Header - Series 810

RA CONNECTOR IDC. 1Certified LR Features. Standards. Disconnectable Insulation displacement connectors for 1.27mm pitch ribbon cables. 2.

PAPER/PLASTIC CAPACITORS

CABLED SINGLE CONDUCTORS

PRESSURE TRANSDUCERS. Specifications. Individual Specifications

Hot runner thermocouple Model TC46

OEM Pressure Transmitters

Conductors Braids Special products made of copper wire

Whether it s a harsh outdoor environment or an indoor desktop, PowerFilm has an optimal solution for your application.

Data sheet. Connection line M12 4-pole D-coded 1.0 m. Illustrations P/N 142M1D11010 EAN Product specification. Page 1/

- (90 - f (GHz)) db (.05 SQT(f(GHz))) db

RA CONNECTOR IDC. 1Certified LR Features. Standards. Disconnectable Insulation displacement connectors for 1.27mm (.050") pitch ribbon cables

Instruction Manual. Model HC1 Series Electrodless Conductivity Sensors

Flexible Heaters. Silicone Rubber Heaters

ACA-20PC Series Digital, LED-Display AC Ammeters with Built-in Current Transformers

LDC Pricelist. ( WEF 1st August 2017 ) "POLYCAB" 4 Pair Unshielded Twisted Pair (UTP) LAN (Computer) Cables. Unarmoured.

DEFENSE AND AEROSPACE GUIDE

THERMOCOUPLE CABLE. Compensating & Extension Make Up: Solid or stranded conductor Conductor of required thermocouple type Iron constantan Jx

FLX TM Self-Regulating Winterization/Freeze Protection INSTALLATION PROCEDURES

Heating Cable. Cut to Length in Field. Description

SMD High Power Precision Resistors

SMB Amphenol. 50 ohm Coaxial Connectors Specifications 36 Plugs 37 Jacks 38 Bulkhead Receptacles PCB Receptacles 41-43

Transcription:

DATA SHEET R-SCAPLC SEALED PLATINUM SURFACE TEMPERATURE SENSOR MODEL 29399 This low cost, sealed platinum surface RTD is the world s toughest for surface temperature measurement. The IEC 751 sensor is refractory sealed for ±0.05 C stability. Its small strong design allows this package to conform on curved surfaces for accurate response in milliseconds. Leads welded within the sealed RTD provide this sensor s durablity. Moisture resistance for condensing environments is provided by Kapton lamination that encapsulates the assembly. Standard operating range is 50 C to 150 C. Strong welded leads Full platinum RTD stability Tough Moisture resistant Strain isolated Temperature range is 50 C to 150 C Time constant is 0.3 seconds on metal surfaces Long-term stability better than ±0.05 C (0.02Ω) per 5 years Specialists in Temperature Measurement.

Performance Specifications Temperature Range 50 C to 150 C ( 60 F to 300 F) Sensing Element International grade thin film platinum α = 0.00385 Ω/Ω/ C Ice Point Resistance 1000 ± 1.2Ω, (±0.3 C) International Class B, (±0.12%) Time Constant <0.3 Seconds on metal surfaces Self-Heating >15 mw/ C mounted Interchangeability ±(0.3 C + 0.005 t C), IEC 751 Class B Long Term Stability Better than 0.05 C (0.02Ω) per 5 years Insulation Resistance >50 MegOhms at 50VDC at 25 C Maximum Current 2 ma for limited seif heating Recommended Current 1 ma maximum Case Material Kapton, Sensor is refractory passified overall before lamination Lead Material 26 AWG nickel-plated, stranded copper TFE Teflon insulated twisted leads Size Reference 0.25" wide x 0.5" long Thickness over sensor: 0.06" Thickness over leads: 0.045" Ordering Specifications 29399 RTD with Teflon insulated leads LEAD LENGTH in inches (12 standard) 29399 12 Typical write-up for 29399 Specialists in Temperature Measurement Proudly manufactured in USA

MODEL 22810 Model 22810 is a polyimide insulated surface sensor designed to provide a practical method for measuring surface temperature. These sensors are small, flexible, and their low mass has minimal thermal effect on the material being measured. They are ideally suited for applications where the device can be permanently mounted using adhesives or other mechanical mounting methods. Operating Temperature Range The useful range of operation for Model 22810 is: 200 C to +232 C ( 320 F to +450 F) with permissible exposure to 260 C (500 F) for short periods clamped. Sensing Element The standard sensing element is platinum with a resistance of 100 ohms at 0 C with a temperature coefficient of 0.00385 Ω/Ω/ C nominal (IEC751). Accuracy Standard (22810-1) ±0.50 ohms 0.50% of temperature Optional (22810-2) ±0.22 ohms 0.25% of temperature Stability The sensor will have less than 0.2 C drift per year at rated service temperature with proper mounting. Time Response <200 milliseconds lag on metal surfaces. Self-Heating The bare sensor will rise less than 1 C while dissipating an I 2 R power of 15 milliwatts on metal surfaces. Lead Wire #26 AWG stranded nickel-plated copper conductors, PFA Teflon insulated 3 or 4 conductor ribbon cable. Insulation Resistance The insulation resistance between outer sensor insulation clamped between two metal plates and the common lead wire is: 50 megohms minimum with 50 VDC applied to a dry sensor at room temperature. (ASTM-E-644) Mounting Will conform to surfaces with radii down to 3/8 inch transverse to the element winding and 1 1/2 inch longitudinal to the winding. Caution Only bend transverse to grid axis. fer to AN-S (PN 22810) for further information.

Temperature Coefficient 0.00385ohms/ohms/ C Nominal IEC751 C ±Class B R/R0 C ±Class B R/R0 C ±Class B R/R0-200 0.185 50 1.194 300 ±1.8 2.120-190 0.228 60 ±0.6 1.232 310 2.156-180 ±1.2 0.271 70 1.271 320 2.191-170 0.313 80 1.309 330 2.227-160 0.355 90 1.347 340 ±2.0 2.262-150 0.397 100 ±0.8 1.385 350 2.297-140 ±1.0 0.439 110 1.423 360 2.332-130 0.480 120 1.461 370 2.367-120 0.521 130 1.498 380 ±2.2 2.402-110 0.562 140 ±1.0 1.536 390 2.436-100 ±0.8 0.603 150 1.573 400 2.471-90 0.643 160 1.610 410 2.505-80 0.683 170 1.648 420 ±2.4 2.540-70 0.723 180 ±1.2 1.685 430 2.574-60 ±0.6 0.763 190 1.722 440 2.608-50 0.803 200 1.759 450 2.642-40 ±0.5 0.843 210 1.795 460 ±2.6 2.676-30 0.882 220 ±1.4 1.832 470 2.709-20 0.922 230 1.868 480 2.743-10 0.961 240 1.905 490 2.776 0 ±0.3 1.000 250 1.941 500 ±2.8 2.810 10 1.039 260 ±1.6 1.977 510 2.843 20 1.078 270 2.013 520 2.876 30 1.117 280 2.049 530 2.909 40 ±0.5 1.155 290 2.085 540 ±3.0 2.942

DATA SHEET NO. R-STR-LOW WIDE RANGE STRAPON RTD SENSORS MODELS 22391, 22392 & 22393 ISO 9001 CERTIFIED Platinum Surface RTD Wide Temperature Range Non Penetrating Low Cost Installation Sensor Sealed for Condensing or Wet Environments Stable: Drift is Less Than ±0.05 C Over 5 Years Permanently Bonded Assemblies - Metal Contact Plate Under Sensor - High Performance Bonded Fiber Insulation Over Sensor Mount by Bonding (22391), Bolt (22392) or Strap (22393) Performance Specifications Wide Operating Temperature Range: 200 C to +232 C ( 320 F to +450 F) continuous as mounted. 260 C (500 F) short term clamped. Sensing Element: International grade thin film platinum. α = 0.00385Ω/Ω/ C or Industrial grade thin film platinum. α = 0.00375Ω/Ω/ C Ice Point Resistance: 100±0.12Ω or 1000±1.2Ω; Class B (±0.12%) Interchangeability: ±0.3 C or 0.6% of temperature. IEC 751 Class B above 50 C Long Term Stability: Less than 0.05 C drift per 5 years above 50 C Time Constant: Less than 1/2 second for the sensor to reach 63.2% of a change in temperature Self Heating: The bare sensor will rise less than 1 C while dissipating 25 milliwatts mounted. Insulation Resistance: The insulation resistance between outer sensor insulation clamped between two metal plates and the common leadwire is 50 megohms minimum with 50 Volts DC applied. Maximum Current: 100Ω=5mA, 1000Ω=2mA for limited self heating Recommended Current: 1mA Body Materials: Stainless Steel and flexible polyimide fiber insulation Lead Materials: Nickel plated, stranded copper cable insulated as follows: 2 wire: 22 AWG FEP Teflon, black and red twisted pair FEP overall 3 wire: 26 AWG PFA Teflon, white, plus brown for 3 wire, fused parallel Specialists in Temperature Measurement

Drawings Ordering Specifications 22391 Strapon for adhesive or tape mounting 22392 Strapon for bolt down with 3/16, #8 or 4.5mm 22393 Strapon for curved surface>2" dia. with pipe clamp Resistance Specification T01 100Ω ± 0.12Ω@ 0 C, (α = 0.00385Ω/Ω/ C Int l Grade IEC 751 Class B) T10 1000Ω ± 1.2Ω@ 0 C, (α =.00385Ω/Ω/ C Int l Grade IEC 751 Class B) H10 1000Ω ± 1.2Ω@ 0 C, (α =.00375Ω/Ω/ C Industrial Grade Class B) Number of Leads A 2 wire B 3 wire Lead length in inches (12" standard) Pipe Clamp 22393 Only 1 Pipe Dia. 2" to 8" (standard) 2 Pipe Dia. 8" to 10" 3 Pipe Dia. 10" to 16" 4 Pipe Dia. 16" to 24" 5 Pipe Dia. 24" to 36" Typical Write Up ISO 9001 CERTIFIED Specialists in Temperature Measurement Proudly manufactured in USA

DATA SHEET R-STRWRTF WIDE RANGE PLATINUM STRAPON RTD SENSORS PN 22525, 22526 Platinum surface temperature sensor Wide Temperature Range 200 C to 260 C Non-penetrating Low-cost installation Sensor sealed for condensing or wet environments Adhesive-less mounting High-performance bonded fiber insulation over sensor Mount by bolt (22525) or strap (22526) Performance Specifications Operating Temperature Range 200 C to +232 C ( 320 F to +450 F) -1 Sensor Continuous as mounted (300 C short term) 200 C to +260 C ( 320 F to +500 F) -2 Sensor Continuous as mounted (300 C short term) Sensing Element International grade thin film platinum α = 0.00385 Ω/Ω/ C nominal (IEC751) Ice Point Resistance 100 ± 0.12Ω, (±0.3 C) @ 0 C 1000 ± 1.2Ω, (±0.3 C) @ 0 C Interchangeability ±(0.3 C + 0.005 t C), IEC 751 Class B Above -50 C Time Response <300 milliseconds lag on metal surfaces Stability Better than 0.05 C (0.02% of resistance) per 5 years, -50 C to 200 C Self-Heating The bare sensor will rise less than 1 C while dissipating power of 15mW (ASTM-E-644) Insulation Resistance The insulation resistance between outer sensor insulation clamped between two metal plates and the common lead wire is 50 megohms minimum with 50 VDC applied to a dry sensor at room temperature (ASTM-E-644) Mounting Will conform to 2 inch minimum diameter (see ordering data) Body Material Stainless steel and flexible bonded fiber insulation Lead Wire -1 Sensors #22 AWG tin-plated, (2-wire) FEP Teflon over each twisted black/red, FEP overall #24 AWG tin-plated, (3-wire) FEP Teflon over each twisted whute/2 red, FEP overall -2 Sensors #26 AWG stranded nickel-plated copper conductors, PFA Teflon insulated 2 (2 white), 3 (2 white/brown), or 4 (2 white/2 red) conductor ribbon cable, Specialists in Temperature Measurement.

Dimensional Drawing Ordering Specifications 22525 Strapon for bolt down with 3/16, #8 or 4.5 mm 22526 Strapon for curved surface >2" minimum diameter with pipe clamp (see ordering data) SENSOR TYPE 1 (-200 C to 232 C) PARALLEL RIBBON CABLE 2 (-200 C to 260 C) TWISTED LEADS WITH OVERJACKET RESISTANCE SPECIFICATION @ 0 C T01 100Ω ± 0.12Ω @0 C (α = 0.00385Ω/Ω/ C) T10 1000Ω ± 1.2Ω @0 C (α = 0.00385Ω/Ω/ C) NUMBER OF LEADS A 2 Wire B 3 Wire C 4 Wire ( -2 Sensors only) LEAD LENGTH IN INCHES (12 STANDARD) (ADD X SUFFIX FOR SST BRAID OPTION) 1 Typical Write-Up for 22489 PIPE CLAMP - 22526 ONLY 1 Pipe diameter 2" to 8" (standard) 2 Pipe diameter 8" to 10" 3 Pipe diameter 10" to 16" 4 Pipe diameter 16" to 24" 5 Pipe diameter 24" to 36" 22526 2 T01 B 12X 1 Typical write-up for 22526-2 Specialists in Temperature Measurement Proudly manufactured in USA

1 di 2 04/05/2009 10.00 DATA SHEET R-STRWR Wire-wound platinum surface RTD Wide Temperature range 270 C to 260 C Non-penetrating Low-cost installation Sensor sealed for condensing or wet environments Adhesive-less mounting High-performance bonded fiber insulation over sensor Mount by bolt (22488) or strap (22489) Operating Temperature Range 270 C to +260 C ( 452 F to +500 F) Continuous as mounted (300 C short term) Sensing Element The standard sensing element is platinum wire with a resistance of 100 ohms at 0 C with a temperature coefficient of 0.00385Ω/Ω/ C nominal (IEC751) or 0.00391Ω/Ω/ C reference grade Accuracy Standard ( 1, 3) ± 0.50 ohms or 0.50% of temperature, whichever is greater Optional ( 2, 4) ± 0.22 ohms or 0.25% of temperature, whichever is greater Time Response <200 milliseconds lag on metal surfaces Stability The sensor will have less than 0.02 C drift per year at rated service temperature with proper mounting Self-Heating The bare sensor will rise less than 1 C while dissipating power of 25mW (ASTM-E-644) Insulation Resistance The insulation resistance between outer sensor insulation clamped between two metal plates and the common lead wire is 50 megohms minimum with 50 VDC applied to a dry sensor at room temperature (ASTM-E-644) Mounting Will conform to 2 inch minimum diameter (see ordering data) Body Materials Stainless steel and flexible polyimide fiber insulation Lead Materials #26 AWG stranded nickel-plated copper conductors, PFA Teflon insulated 3 or 4 conductor ribbon cable Teflon is a registered trademark of Dupont

2 di 2 04/05/2009 10.00 22488 Strapon for bolt down with 3/16, #8 or 4.5 mm 22489 Strapon for curved surface >2" minimum dia. with pipe clamp (see ordering data) RESISTANCE SPECIFICATION @ 0 C 1 100 ± 0.50Ω @0 C, a = 0.00391 Reference grade platinum 2 100 ± 0.22W @0 C, a = 0.00391 Reference grade platinum 3 100 ± 0.50Ω @0 C, a = 0.00385 (IEC 751) International Grade Platinum 4 100 ± 0.22Ω @0 C, a = 0.00385 (IEC 751) International Grade Platinum NUMBER OF LEADS A 3 Wire B 4 Wire PIPE CLAMP - 22489 ONLY 1 Pipe diameter 2" to 8" (standard) 2 Pipe diameter 8" to 10" 3 Pipe diameter 10" to 16" 4 Pipe diameter 16" to 24" 5 Pipe diameter 24" to 36" 22489 1 A 1 Typical write-up for 22489

1 di 2 04/05/2009 9.58 DATA SHEET R-HD Heavy Duty for Hostile Environments Non-penetrating Weld, Bolt or Clamp in Place Operating Temperature Range For S [standard]: 200 C to 260 C ( 320 F to 500 F), For H [high]: 0 C to 480 C (32 F to 900 F) Sensing Element The standard sensing element is platinum with a resistance of 100Ω at 0 C with a temperature coefficient of resistance 0.00385 Ω/Ω/ C nominal (IEC 751). Interchangeability ±0.1Ω (±0.25 C) or 0.4% of temperature, whichever is greater. Stability The sensor will have less than 0.05 C drift per year at rated service temperature with proper mounting. Time Response 8 seconds for the sensor to reach 63.2% of a step change in temperature in water flowing at 3 feet per second transverse to the sensor. TM-E-644) Self-Heating The bare sensor will rise less than 1 C while dissipating power of 35 milliwatts in still air. (ASTM-E-644) Insulation Resistance The insulation resistance between outer sensor housing and the common leadwires is: 50 megohms with 50 VDC applied to a dry sensor at room temperature. (ASTM-E-644) Lead Wire S: #22 AWG stranded nickel plated copper TFE Teflon insulated, 3-wire configuration. H: #22 AWG stranded nickel plated copper fiberglass insulated, 3-wire configuration. Mounting Sensors can be bolted, clamped or welded into place. Reference Data For installation and mounting considerations refer to Application Note AN-S Teflon is a registered trademark of Dupont

22802 Heavy Duty Surface RTD Operating Temperature Range S H Standard ( 200 C to +260 C) High (0 C to 480 C) Lead Length (36 inch standard) Specify in Inches 22802 - S - 36 - Typical Write-Up for 22802