Filters. DFFH & DFFHM Series Service and Parts. Index. This symbol is followed by user tips and particularly useful information

Similar documents
Filters. HF2P 79.4 Series Service and Parts. Index P Clogging. Indicator Port G 1/

Filters. HF3P Series Places 60 b c x d DP 4 Places Flange

Filters. HF4R Series. Service and Parts. Index. Inlet. Outlet. ø7 (ø177.8mm) Bolt Circle ø6.25 (ø158.8mm) ø0.44 (ø11.1mm) 4 Places Equally spaced

HFM Series Service and Parts

Filters. DFP, DFPF Series. 2. Element Replacement. 2.1 Element Removal

LF & LFF Series Service and Parts

Filters. RFD Series. Change-Over Return Line Filter Service and Parts. 2. Element Replacement. 2.1 Element Removal

MDF Series Service and Parts

DF, DFF & DFFX Series Service and Parts

RKM Series Service and Parts

LPF Series Service and Parts

RFN Series Service and Parts

RFL Cast Series Service and Parts

Duplex Filter NFD (for NFD UHE (ultra-high efficiency), see NF Series) Service and Parts

NF, NF UHE, NFD UHE & NF MMP with 2600 R element (for Ecomicronfit ( D) element version, see NF 1314/2614 Eco-Fit Series) Service and Parts

DFDK Series Service and Parts

Selector Valve RV 713

Monoblock Directional Control Valve RM 230

Stainless Steel Pressure Filters Housings, Elements, Indicators & Sizing

HIGH PRESSURE FILTERS DFFX Series Reverse Flow Differential Pressure Optimized Filters 6090 psi up to 160 gpm

Replacement Elements

Spare parts list Inline filter FLND switchable

HIGH PRESSURE FILTERS DF/DFF 1500 Series Inline Filters 6090 psi up to 250 gpm

Stainless Steel Pressure Filters

Spare Parts List Filter NFD Change-Over Version

Spare Parts List Return line filter RF

LOW PRESSURE FILTERS RF Series In-tank / Inline Filters 360 psi up to 400 gpm

MEDIUM PRESSURE FILTERS

HIGH PRESSURE FILTERS

Spare Parts List Return Line Filter RFM with 4-hole attachment

Spare Parts List Tank-Top Return Line Filter RFN with Elements to DIN up to 630 l/min, up to 10 bar

Spare parts list Return line filter RFM with 2-hole attachment

LOW PRESSURE FILTERS RFM Series In-Tank Return Line Filters 145 psi up to 224 gpm

HIGH PRESSURE FILTERS

HIGH PRESSURE FILTERS

HIGH PRESSURE FILTERS

Duplex Pressure Filters

Series RFL In-Line Filter

Spare Parts List Mobile Spin-On Filters MF/MFD. Flow rates up to 300 l/min Pressure range up to 8 bar Material: Aluminium / Sheet Steel

NFH Low Pressure Filters

Series RFLD Duplex In-Line Filter

HIGH PRESSURE FILTERS Series HF2P

PRESSURE FILTERS FOR MODULAR STACKING. Series DF-Z Pressures to 4500 psi Flows to 10 gpm APPLICATION PRODUCT FEATURES FILTER ELEMENTS

Pressure Filter DF...K P, DF...M P, Flange Mounted

Change-Over Pressure Filter DFDK

HIGH PRESSURE FILTERS HF4P Series Inline Filters 5000 psi up to 120 gpm

Directional Control Valve. Formerly the RSM290 Series. Technical data. Pressures / Flows Max. operating pressure set per port:

World Pressure Filters. A New Standard in 7,000 psi Pressure Filters

HYDRAULIC AND LUBE OIL FILTERS RFM Series

World Pressure Filters A New Standard in 7,000 psi Pressure Filters

Pressure Filter DF Pressure Filter for Reversible Oil Flow DFF/DFFX

NFHD Modular Duplex Filter System Pressures to 360 psi Flows to 450 gpm 4 Ports

World Pressure Filters A new standard in 7,000 psi pressure filters

15/40/80CN Series Coreless Medium Pressure Filters

Return Line Filter RF

12CS/50CS Series. Coreless Spin-on Filters

Pressure Filter for Manifold Mounting DFP and for Reversible Flow DFPF

PT Series Tank Top Filters

FILTER ELEMENTS. Overview of Elements PN# / / FIL

Return Line Filter HF4R up to 450 l/min, up to 10 bar

LOW PRESSURE FILTERS MF, MFD, MFDS Series Spin-On Filters 250 PSI up to 120 GPM

LOW PRESSURE FILTERS MF, MFD, MFDS Series Spin-On Filters 250 PSI up to 120 GPM

SPIN-ON FILTERS & ELEMENTS

Inline Filter LPF D A Flange-Mounted up to 280 l/min, up to 25 bar

Return Line Filter RF

Pressure Filters DF...M A / DF...Q E DF...MHA / DF...MHE Flow rates up to 500 l/min Pressure range up to 315 bar Material: SG Iron/ADI, Steel

Pressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T ) Buna-N (FKM on request)

MEDIUM PRESSURE FILTERS MFX Series Inline Filters 725 psi up to 35 gpm Hydraulic Symbol

Change-Over Inline Filter RFLD Welded Version

Change-Over Inline Filter RFLD Weld Version

Pressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T )

Low Pressure Filters

12CS/50CS Series Coreless Medium Pressure Filters

Inline Filters NF. Flow rates up to 3,500 l/min Pressure range 25 bar Material: Aluminium / Aluminium-Cast Iron

15P/30P Series High Pressure Filters

RF4 Series. Return Line Filters

Low Pressure Filters

Low Pressure Filters

MultiRheo Filter MRF 1/2/3/4/5/6/7

Suction Filter SF/SFM/SFF and Suction Filter Elements S/S..

EN / Modern Duplex Filters for Large Engines

15/40/80CN Series. Medium Pressure Filters

Oil Solutions. GA/BGAH Series Medium Pressure Filters. Global Filtration Technology. Filtration.

By-pass: 1,7 bar (24.6 psi) setting N.B. Cartridge with integrated bypass valve and antidrainback membrane

Process Inline Filter Medium / High Pressure PFM / PFH

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800)

Pressure: Max working 110 bar (1600 psi) (acc. to NFPA T ) Burst 330 bar (4800 psi) (acc. to NFPA T ) Wire mesh µm

Pressure: Max working F280 D12x port size 1/2 & 3/4 : 420 bar (6000 psi) Burst F280 D12x port size 1/2 & 3/4 : 1260 bar (18000 psi)

Filtrec elements are tested according to ISO 2941, ISO 2942 and ISO 23181

Moduflow Series IL2/RF2/CF2 Low Pressure Filters

Pressure: Max working 280 bar (4000 psi) (acc. to NFPA T ) Burst 840 bar (12200 psi) (acc. to NFPA T )

Return Line Filter RFM with 4-Hole Mounting

Return line and Suction Boost Filter RKM

Electrohydraulic Drive System EHC-A

Inline Filter RFLD. Change-Over. Cast Version Flow Rates up to 1300 l/min* Pressure Range 25/40/64 bar With Ball Change-Over Valve E /01.

Change-Over Inline Filter AFLD to API 614

Connection Ports: 3/4 1 1/4 BSP (other thread options on request) aluminium alloy NBR (FKM on request)

50P Series High Pressure Filters

Inline Filter RFL. Cast version Volume rates up to 1300 l/min* Pressure range 25/40 bar

Connection Ports: 1/2 1 1/2 BSP (other thread options on request) aluminium alloy NBR (FKM on request)

Transcription:

142.9 INLET 1.38 35 OUTLET Index 1.25 31.8 1. General 1.4 Tools Required for Maintenance 1.5 Torque Requirements 2. Maintenance 3. Changing the Element 4. Spare Parts List 5. Replacement Element Model Code 2.63 66.7 Filters [1.00] 1/2"-13UNC-2B x 25.4 DP 4 Places Mounting Holes [0.55] 3/8-24UNF-2B x 14 4 Places 0.24 6 3.35 85 1.85 47.1 SAE 20 Thread or SAE This 20 Flange pressure code unit is for use with hydraulic power or lube systems 62 (1-1/4") only. All repair, maintenance, installation [9.68] and commissioning work must be carried out DFFH by trained 160 personnel. 246 Operate this pressure unit in accordance with hydraulic power 12.05 or lube system operating instructions. DFFH 240 306 Ensure the pressure unit is sufficiently cool before handling. [19.17] This pressure unit is DFFH suitable 280 for 487 use with hydraulic or lubricating fluids only. It is the responsibility of the operator to comply with local water regulations. 0.56 14.2 DFFH & DFFHM Series Service and Parts This symbol is followed by user tips and particularly useful information. 3.88 98.6 P Clogging Indicator Port G 1/2" 4.5 1 CAUTION! This symbol denotes safety precautions, the non-observance of which can endanger persons and the environment. Observe proper venting procedures to avoid the formation (Optional) of air pockets. Drain Port G 1/2" Caution: Pressurized unit. Purge system pressure before performing any work on the pressure unit. 3.75 Under no circumstances must [3.35] any modifications (welding, drilling, 95.2 or opening by force ) be carried 85 out on the pressure unit. Any modifications will void the Clearance warranty. required Statutory accident prevention for regulations, Element Removal safety regulations and safety data sheets for fluids must be observed. When working on or near hydraulic systems, avoid exposure to open flames and spark generating equipment. Do not smoke near equipment. Comply with all regulations with regard to the disposal of used oil and waste. Wear proper protective clothing and guards to avoid injury or scalding due to high pressure or high temperature oil. Filter housing must be grounded. Disconnect all electrical power to the system and other electrical components, prior to working on filter clogging indicators. HEX 1.26 32 NOTE: All details subject to technical modification

1. General 1.1 Commitment to Quality HYDAC demonstrates its commitment to quality through the implementation of an ISO 9001: 2000 program, which encompasses not only product design and manufacturing but service and delivery as well. 1.2. Installation Before installing the filter in the system, check that the operating pressure of the system does not exceed the maximum allowable operating pressure of the filter. Observe type code label on the filter. Important: When operating filters without bypass valve above 290 psid (20 bar), high collapse BH/HC type filter elements must be used to ensure safe operation. 1.3. Commissioning Unscrew bowl and check that the correct filter element is installed. Screw in bowl again fully (metal to metal contact) and then unscrew by one quarter-turn (the sealing effect will not be improved by overtightening.) Switch on hydraulic system and check filter for leakage. Vent filter at an appropriate point in the system. 1.4. Tools Required for Maintenance Size Wrench size for filter bowl Allen wrench size for oil drain plug Wrench size for VD 0 A.1 160-280 32 mm 10 mm 27 mm 330-1320 36 mm 10 mm 27 mm 2. Maintenance 2.1. General This section describes periodic maintenance requirements. Periodic and thorough maintenance will ensure operator safety and the life of the filter. 2.2. Maintenance Procedures Only high quality spare parts meeting the technical requirements specified by the manufacturer should be used, quality is always guaranteed with HYDAC original spare parts. Keep tools, working area and equipment clean. After disassembling the filter, clean all parts and check for damage or wear. Replace parts as required. When changing filter elements, a high level of cleanliness must be observed. 2.3. Interval Between Changing Elements To ensure optimum performance, HYDAC recommends replacing filter elements every 6 months or upon indication, whichever occurs first. HYDAC recommends installing the filter with a clogging indicator (visual and/or electric or electronic) to monitor for excessive filter element pressure drop. If the clogging indicator trips, immediately change or clean the filter element. (Only wire mesh and metal fiber elements can be cleaned). If no clogging indicator is installed, HYDAC recommends changing elements at specified intervals (depends on filter sizing and conditions). Higher dynamic loads across the element might necessitate shorter intervals between changes. Shorter intervals can also be expected during commissioning, repairs, oil changes, etc. of the hydraulic system. 1.5. Torque Values for Clogging Indicators Type Max. Torque Nm [ft-lb] Clogging Indicators - VD LE, LZ 50 [37] Clogging Indicators - VD others 100 [74] Oil Drain Plug 80 [59] - G½ Bowl / Lid or End Cover Do not Torque (See 1.3 and 3.2) 2

3. Element Replacement 3.1. Element Removal 1. Switch off hydraulic system and purge filter pressure. 2. Remove oil drain plug (if present). Drain oil into a suitable container. 3. One-piece bowl: Unscrew bowl (collect fluid in a suitable container and clean or dispose of it in accordance with environmental regulations). Two-piece bowl: Unscrew end-cap of bowl (collect fluid in a suitable container and clean or dispose of it in accordance with environmental regulations). Remove threaded pin. 4. Remove filter element from the filter head (examine surface of element for dirt residue and larger particles; these can indicate damage to the components). 5. Replace or clean filter element. (Only wire mesh and metal fiber elements can be cleaned). 6. Clean bowl and head, paying particular attention to the screw threads. 7. Examine filter, especially sealing surfaces, for damage. 8. Check O-rings and replace parts as necessary. 3.2. Element Installation 1. Lubricate sealing surfaces and O-ring using clean hydraulic fluid. Thread on the filter head and bowl. 2. When installing a new element, verify that the designation corresponds to that of the old element. 3. Place filter element carefully onto the element location nozzle in the filter head. For two-piece bowls; secure with threaded pin. 4. One-piece bowl: Apply silver grade anti-seize (per Mil-PRF-907E) to threads. Screw in filter bowl fully (metal to metal contact). Two-piece bowl: Apply silver grade anti-seize (per Mil-PRF-907E) to threads. Screw in endcap fully (metal to metal contact). 5. Screw in oil drain plug (if present). 6. Unscrew filter bowl or end-cap by one quarter-turn. (Note: over-tightening does not improve seal). 7. Switch on hydraulic system and vent filter at an appropriate point in the system. 8. Check filter for leakage. Note: Contamination or incomplete pressure release on disassembly can lead to seizing of the bowl thread. Filter elements which cannot be cleaned must be disposed of in accordance with environmental regulations. 3

4. Spare Parts 4.1 DFFH 160-660 (one piece bowl) 2.1 2.2 / 3.1 / 4.4 2.3 / 3.2 / 4.5 4.2 4.3 1.2 / 4.1 1.1 4.6 Item Consists of Designation 160 240 280 330 500 660 1. Filter element See point 5 Replacement elements 1.1 Filter element According to order 1.2 O-ring 34 x 3.5 42.52 x 2.62 2. Clogging indicator or indicator plug VD 0 A.1 VD 0 A.1 /-V See Filter Clogging Indicator brochure 00305932 00305931 2.1 Indicator plug VD... 2.2 Profile seal ring VD... 2.3 O-ring 15 x 1.5 3. SEAL KIT-E VD/VM/VR 00319648 SEAL KIT-E VD/VM/VR /-V 00319638 3.1 Profile seal ring VD... 3.2 O-ring 15 x 1.5 4. SEAL KIT DFFH NBR 02070226 02068921 SEAL KIT DFFH... FKM 2096200 02085525 4.1 O-ring (element) 34 x 3.5 42.52 x 2.62 4.2 O-ring (bowl) 80 x 4 117 x 4 4.3 Back-up ring (bowl) DF 160 DF 330 4.4 Profile seal ring (VD 0 A.1) VD... 4.5 O-ring (VD 0 A.1) 15 x 1.5 4.6 Oil drain plug G 1/2 NA O-Ring durometer can range from 70-80Sh. EPR Seal Kits available on request. Bowl assembly kits on request - kits include complete bowl with seals, plug, and threaded pin (if present). Other spare parts available on request. Bold items can be ordered. 4

4.2 DFFH 660-1320 (two piece bowl) 2.2 / 3.1 / 4.4 2.3 / 3.2 / 4.5 2.1 4.2 4.3 1.2 / 4.1 1.1 4.2 4.3 4.6 Item Consists of Designation 660 1320 1. Filter element See point 5 Replacement elements 1.1 Filter element According to order 1.2 O-ring 48 x 3 2. Clogging indicator or indicator plug VD 0 A.1 VD 0 A.1 /-V See Filter Clogging Indicator brochure 00305932 00305931 2.1 Indicator plug VD... 2.2 Profile seal ring VD... 2.3 O-ring 15 x 1.5 3. SEAL KIT-E VD/VM/VR 00319648 SEAL KIT-E VD/VM/VR /-V 00319638 3.1 Profile seal ring VD... 3.2 O-ring 15 x 1.5 4. REPAIR KIT DFFH 660-1320 / 2.0 02089592 REPAIR KIT DFFH 660-1320 / 2.0 /-V 02089593 4.1 O-ring (element) 48 x 3 4.2 O-ring (bowl) 117 x 4 4.3 Back-up ring (bowl) DF 330 4.4 Profile seal ring (VD 0 A.1) VD... 4.5 O-ring (VD 0 A.1) 15 x 1.5 4.6 Oil drain plug G 1/2 NA O-Ring durometer can range from 70-80Sh. EPR Seal Kits available on request. Bowl assembly kits on request - kits include complete bowl with seals, plug, and threaded pin (if present). Other spare parts available on request. Bold items can be ordered. 5

4.3. DFFHM 160-1320 2.1 2.2 / 3.1 / 4.4 2.3 / 3.2 / 4.5 5 4.3 4.2 1.2 / 4.1 1.1 4.6 Item Consists of Designation 160-280 330-660 1 pc. Bowl 660-1320 2 pc. Bowl 1. Filter element See point 5 Replacement elements 1.1 Filter element According to order 1.2 O-ring 34 x 3.5 48 x 3 2. Clogging indicator or indicator plug VD 0 A.1 VD 0 A.1 /-V See Filter Clogging Indicator brochure 00305932 00305931 2.1 Indicator plug VD... 2.2 Profile seal ring VD... 2.3 O-ring 15 x 1.5 3. SEAL KIT-E VD/VM/VR 00319648 SEAL KIT-E VD/VM/VR /-V 00319638 3.1 Profile seal ring VD... 3.2 O-ring 15 x 1.5 4. SEAL KIT DFFH NBR 02070226 02068921 02089592 SEAL KIT DFFH... FKM 2096200 02085525 02089593 4.1 O-ring (element) 34 x 3.5 48 x 3 4.2 O-ring (bowl) 80 x 4 117 x 4 4.3 Back-up ring (bowl) DF 160 DF 330 4.4 Profile seal ring (VD 0 A.1) VD... 4.5 O-ring (VD 0 A.1) 15 x 1.5 4.6 Oil drain plug G 1/2 NA 5. O-ring 37.69 x 3.53 56.74 x 3.53 O-Ring durometer can range from 70-80Sh. EPR Seal Kits available on request. Bowl assembly kits on request - kits include complete bowl with seals, plug, and threaded pin (if present). Other spare parts available on request. Bold items can be ordered. 6

5. Replacement Element Model Code Size 0160, 0240, 0280, 0330, 0660, 1320 Filtration Rating (micron) 3, 5, 10, 20 = BH4HC 1, 3, 5, 10, 15, 20 = ON 3, 5, 10, 20 = V 25, 74, 149 = W/HC Element Media BH4HC, ON, V, W/HC Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM) EPR = Ethylene propylene rubber (EPR) 0160 D 003 BH4HC / Supplementary Details SO263 = Modification of ON & W/HC elements for Skydrol or HYJET phosphate ester fluid SFREE = Element specially designed to minimize electrostatic charge generation 6. NOTE The information in this brochure relates to the operating conditions and applications described. For applications or operating conditions not described, please contact the relevant technical department. Subject to technical modifications. Model Codes Containing RED are non-stock items Minimum quantities may apply Contact HYDAC for information and availability 7

Global Headquarters HYDAC INTERNATIONAL GMBH Industriegebiet D 66280 Sulzbach/Saar Germany Tel.: +49 6897 509-01 Fax: +49 6897 509-577 Internet: www.hydac.com Email: info@hydac.com North America Locations USA www.hydac-na.com Filter Division Cooling System Division 2260 City Line Road 1051 Airlie Parkway Bethlehem, PA 18017 Denver, NC 28037 Accessory Division 2204 Avenue C Bethlehem, PA 18017 Cooling System Division 445 Windy Point Drive Glendale Heights, IL 60139 +1.630.545.0800 Electronic Division Process Filter Division Accumulator Division 90 Southland Drive Bethlehem, PA 18017 Filter System Division Process Filter Division 580 West Park Road Leetsdale, PA 15056 +1.724.318.1100 Hydraulic Division 450 Windy Point Drive Glendale Heights, IL 60139 +1.630.545.0800 Mobile Hydraulic Division 1660 Enterprise Parkway Suite E Wooster, OH 44691 HYDAC CYLINDERS LLC 540 Carson Road North Birmingham, AL 35217 +1.205.520.1220 Canada 14 Federal Road Welland, Ontario, Canada L3B 3P2 +1.905.714.9322 Sales Office & Operations 1718 Fry Road, Suite 100 Houston, TX 77084 +1.281.579.8100 NE Sales Office 1660 Enterprise Parkway Suite E Wooster, OH 44691 SE Sales Office 1051 Airlie Parkway Denver, NC 28037 NW Sales Office 1201 NE 144th St. Bldg. B, Suite 111 Vancouver, WA 98685 Hydraulic Division Tech Center 430 Windy Point Drive Glendale Heights, IL 60139 +1.630.545.0800 www.hydac-na.com Sales Office 5160 75 Street NW Edmonton, Alberta, Canada T6E 6W2 +1.780.484.4228 Sales Office Montreal, Québec, Canada J2M 1K9 +1.877.539.3388 Mexico HYDAC INTERNATIONAL SA de CV Calle Alfredo A Nobel No 35 Col Puente de Vigas Tlalnepantla, Edo Mexico CP 54090 Mexico +011.52.55.4777.1262 www.hydacmex.com Copyright 2016 Brochure - Service DFFH/DFFHM