NEPAL ELECTRICITY AUTHORITY (A Government of Nepal Undertaking)

Similar documents
This tender addendum and clarification forms part of the Request for Proposal and Contract documents, and modifies them as follows:

TENDER DOCUMENT. (TENDER No: NRO/CON/696/660) FOR

TENDER FOR FOR 2 X 1010 KVA, 1500 RPM, 415 V DG SETS FOR CONSTRUCTION OF NEW CDRI CAMPUS AT SITAPUR ROAD, LUCKNOW (U.P.) SUMMARY OF PRICE BID

CHAPTER 4 PROTECTION REQUIREMENTS

AN ISO 9001 & COMPANY TENDER DOCUMENT. TENDER No: DLI/CON/696/411 FOR

2 Unit Petrol Engine Spare parts kits for 4 WD Nissan Patrol

Circuit Breaker Prepared By :

BHARAT HEAVY ELECTRICALS LIMITED, JHANSI

INDIAN MARITIME UNIVERSITY KOLKATA CAMPUS

TECHNICAL SPECIFICATIONS OF PCC PANEL

Key features. DESIGNS: - Conservator type - Hermetically sealed

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5

WEST BENGAL STATE ELECTRICITY DIST. COM. LTD. ( A

Package Price for Grid Connected 6.0 MW Synchronized Electricity: Please Call For Details Price

COMPACT SUBSTATION GUIDE

(High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA MATERIALS MANAGEMENT / CAPITAL EQUIPMENT. Enquiry Date:

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS

MAIN INCOMER -1 (500 KVA TRF.)

Electrical Power Electric power electrical electric power Electric power electric electric

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 6

Package Price for Grid Connected 3.3 MW Synchronized Electricity: Please Call For Details Price

Syllabus for the Trade of Electrician Duration : Six Month Second Semester Semester Code: ELE: SEM II

TENDER DOCUMENT TENDER No.: NRO / CON / 592 / 537 FOR SUPPLY & INSTALLATION. DG Sets & Sychronising Panel

Tender Schedule for Electrical Works at Varagani Branch. Sl. No. Particulars Quantity Unit Rate Amount

MNS Light F. Low-voltage switchgear with fixed units. ABB LV Systems

Item Code Description Unit Qty Total

LP 10. GENERATOR SPECIFICATION Power Rating (KVA) 10. Electric Power (KWe) 8. Rated Current (A) 14. No of Phases/Volts* 3/415

GENERATOR & SINGLE-FUNCTION PROTECTION

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427

CUSTOMER / ACCOUNT INFORMATION Electric Utility Customer Information (As shown on utility bill)

Training & Didactic Systems. Fundamentals of Electrical Engineering

ELE-CMS-E-2007 Electrical Project Engineer PERSONAL DATA EDUCATION LANGUAGES COMPUTER SKILLS TRAINING COURSES AND CERTIFICATIONS

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 2

Extensible Unit - VCE2a

Power IT Compact Secondary Substations, CSS. Low Voltage Switchboard, LVS2

D509E. Manual Motor - Starters

SECTION MICROPROCESSOR TRIP UNITS FOR LV CIRCUIT BREAKERS. This section is organized as indicated below. Select desired Paragraphs.

VOLUME III DRAWINGS. Jammu & Kashmir. KARNAH HEP (3 x 4 MW) UPGRADATION OF KARNAH HEP DETAILED PROJECT REPORT FOR. (FROM 2 x 1 MW To 3 x 4 MW)

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Interconnected Electric System Protection Requirements

CENTERLINE 2500 Low Voltage Motor Control Centers and Switchgear Assemblies

AC Wattmeters and VArmeters

Controls / Terminal Blocks Controls. CXS Series Special Cam Switches (IEC 947-3) Special Cam Switches CXS Series Features

PRICE LIST THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Amendments in Technical Specification No. S-137/DD-177 July 2007 for 11KVAutomatic Switched Capacitor bank at Sub-Stations (33/11KV).

SCHEDULE OF QUANTITIES ITEM DESCRIPTION

MX431 Generator Automatic Voltage Regulator Operation Manual

PRICE LIST THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Form G5-1 PACIFIC GAS AND ELECTRIC COMPANY GENERATION PRE-PARALLEL INSPECTION

ANSI Switchboard Meters

PRICE LIST THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

SECTION V SWITCHBOARD I 4 Engine/Gen Control Cubicles II 1 Synchronizing System III 1 Ground Detection Network IV 1 600V Feeder Section V 2

Type CDG 14 Extremely Inverse Time Overcurrent and Earth Fault Relay

18 Industrial and Commercial P ower System Protection

PowerCube type PB series A complete solution for OEMs

RAPTOR DEFAULT TEST TEMPLATES

825-P Modular Protection System for motors Specification Guide

CHAPER 5 POWER FLOW STUDY IN THE INTEGRATED GRID NETWORK

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

UniPack compact secondary substations (CSS) upto 36 kv For safe, reliable and space saving power distribution solutions

SYLLABUS FOR ELECTRICAL SUPERVISOR CERTIFICATE OF COMPETENCY (SCC MV) Electrical Engineering Paper (Written Test)

Supply of 63 kva DIESEL GENERATOR SET WITH AMF

Micro Contactor MA Series

Technical Specification of GECOL. Packaged Transformers

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

5. High voltage warning labels should be placed on all cabinet doors and terminal covers enclosing equipment operating at above 50 volts.

CLIENT: PROJECT: PO#: ESTIMATOR:

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

NPS/003/010 - Technical Specification for 400V Assemblies (LVAC Boards) utilised in Major Substations

Metal Clad VCBs ~ Mk1

INVITATION TO TENDER MR 84/2016. SUPPLY and Install 110V DC BATTERY BANKS and CHARGERS for Rarawai, Sabeto and Lautoka Switching Station

Low-voltage switchgear MNS Light W. Installation, handling and operation. ABB LV Systems

34 th Hands-On Relay School

: Material Description Quantity UOM

INSTALLATION INSTRUCTIONS

TRT SYSTEM. Product Description

PLATINUM SERIES SWITCHBOARD METERS

31-SDMS-01 REV. 03 SPECIFICATIONS FOR

Standards, Procedures and Policies for Grid Connection

ICG Switchgear Price List 2009

Technical Particulars and Guarantees of 2.5 MVA, 11/0.416kV Transformer No. Description Unit

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

EMPAC Metal enclosed capacitor bank for wind applications

DPX moulded case circuit breakers

Basic function. Rated current. Appropriate for three-phase motors of output 2) [kw] I n. = 400 V a.c. 2) Appropriate for three-phase motors

INVITATION FOR QUOTATION. TEQIP-III/2018/gcej/Shopping/50

C1000 Series Automatic Cap Bank

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT

QUOTING SHEET BIDDER'S PRICE % QUOTE ABOVE / AT PAR / BELOW In figures

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

Date Issued: 10 August 2009 Status: ISSUED Review Date: 10 August 2011 Ref: NS5.3 DISTRIBUTED GENERATION TECHNICAL REQUIREMENTS TABLE OF CONTENTS

Technical Specification No.- S-168/DD KV Switchgear Panel. Vacuum Type

IEEE Northern Canada & Southern Alberta Sections, PES/IAS Joint Chapter Technical Seminar Series

Synchronous motor control. 8/15/2007 Powerflow Technologies Inc 1

Power Solution Supplier

Intelligent Choice for Prestigious Buildings

Section 7 Technical Specification of "Design, Supply, Erection, Installation, Testing and Commissioning 33/11KV AIS Substation on Turnkey Basis Under

E-12 Low-voltage Switchboard

NEPAL ELECTRICITY AUTHORITY (An Undertaking of Government of Nepal) Project Management Directorate

Memshield - ACB Ratings & Specifications

Transcription:

NEPAL ELECTRICITY AUTHORITY (A Government of Nepal Undertaking) Generation Directorate Medium Generation Operation and Maintenance Department SUNDARIJAL HYDROPOWER PLANT REHABILITATION PROJECT Electricity Transmission Expansion and Supply Improvement Project SUNDARIJAL HYDROPOWER PLANT REHABILITATION PROJECT BIDDING DOCUMENT FOR Procurement of Plant for Sundarijal Hydropower Plant Rehabilitation Project (Design, Supply and Install) Single-Stage, Two-Envelope Bidding Procedure Issued on: Invitation for Bids No.: ICB No.: Employer: Country: ICB-SHPPRP 071/72-01 ICB-SHPPRP 071/72-01 Nepal Electricity Authority Nepal VOLUME II OF III June 2015 Sundarijal Hydropower Plant Rehabilitation Project Generation Directorate Durbar Marg, Kathmandu, Nepal Telephone: +977-1-4153070, 4153032 Fax: +977-1-4153016 The information in this Document is for reference only. The Bidders shall base their bids on the Document to be purchased from the Project Office.

Sundarijal Hydropower Plant Rehabilitation Project VI I Drawings

BUS BAR 400 V 2000A, 50 ka/1 sec ACB 400 V, withdrawable type 1250A, 50 ka, 1 sec PT 400 3 : 110 V,Cl 0.5, 15VA 3 CT Class: PS/ 0.5/5P10 CTR: 900/1-1-1 A Burden: 15 VA PT: 400 3 : 110 3 : 110 V 0.5/3P, 50/50 VA Excitation Transformer 400/110 V, 63 kva LA: 500 V, 10 ka CT: 900/1 A Power PT (for excitation) 400/230 V XLPE Cable 2 3 400mm² Synchronous Generator 600 kva, 480 kw, 400V, 50 Hz, 3 Phase, PF: 0.80, 750 RPM CT Class: PS/ 10P10 CTR: 900/1-1 A Burden: 30 VA XLPE Cable 2 3 400mm² STAR POINT CT Class: PS CTR: 900/1 A, 15 VA Low Resistance Earthing 0.242 Ohm CT Class: 5P10 CTR: 900/1 A, 20 VA 87G 11 kv Outgoing Transmission Line Towards Chabahil LA: 9 kv, 10 ka DS/ES: 12 kv, 25 ka PT: 11 3 :0.110 3 :0.110 3 kv Class: 0.2/0.2, Burden: 10/10VA (For metering purpose) CT Class: 0.2/0.2 CTR 70/1-1 A, 10 VA (For metering purpose) Isolator with fused load break switch DS/ES: 12 kv, 25 ka PT: 11 3 / 0.11 / 0.11 kv 3 Class: 0.5/3P Burden : 50/50 VA VCB: Indoor type 12 kv, 630A, 25 ka, 1 sec XLPE Cable: 11 kv 1 3 250 mm² CT: Class 0.5/ 5P10 /PS CTR: 70/1-1-1 A Burden: 20/20 VA CT Single Phase: Class PS/5P10 CTR: 70/1-1 A, Burden: 20 VA Power Transformer: 11/0.4 ± 2 2.5% kv 3-Phase, 1250 kva Z=5%, ONAN, YNd11 XLPE Cable: 1.1 kv 4 3 400 mm² CT Class: PS/0.5 CTR 1800/1-1 A, 15 VA PT 400 3 : 110 V,Cl 0.5, 15VA 3 ACB: 400 V, 2000A, 50 ka, 1 sec PT: 400 3 :110 3 :110 3 V Class: 0.5/0.5, Burden: 15VA (Common for both two units) 25 HV Fuse Syn Panel V F SL1/2 V F VSS V Wh W W/TD VAR PF A/TD A ASS F V/TD VSS V AVR Vref. Aux. Signals G1 Field winding AC EX C1 DC Field Flashing Generator Protection 27 59 24 46 32 40 50/51 50/51N 51V 86 95 64 49 81 78 54N Unit #1 MAIN METER CHECK METER F V/TD V VSS Wh W W/TD VAR PF A/TD A ASS Transformer Cum Line Protection 27 59 81O 81U 87T 64REF 50/51 50/51 51N 51N LV HV LV HV 67L 67N 63A 49 OA 49 WA LOL A 63T 49 OT 49 WT PRDT OSRT A/TD A ASS V/TD V VSS 25 HV Fuse XLPE Cable 11kV 1 3 25mm² Station Transformer: 11/0.4 ± 2 2.5% kv 3-Phase, 50 kva Z=4.5%, ONAN, Dyn11 XLPE Cable: 1.1 kv 1 3.5 50 mm² PT: 400 3 : 110 3 : 110 3 V 3P/1.0, 20/20 VA G2 CT Class: 0.5/5P10 CTR: 150/1-1-1 A Burden: 20/20 VA MCCB 180A, 400 V 100 A, 4-pole contactor BUS BAR 400 V 3-phase, 4-wire, 200 A, 50 ka/ 1 sec MCB 400 V, 6-32 A Unit #2 (same as Unit 1) Single Phase Current Transformer (CT) Three Phase & two core Current Transformer (CT) Potential Transformer (for measurement of voltage) (PT) vaccuum circuit breaker (VCB) withdrawable air circuit breaker (ACB) Disconnecting Switch with Earthing (DS/ES) Lighting Arrestor (LA) XLPE Cable (no. * no. of phase * cross section area) ( Power/ Distribution) Transformer Fuse G1 Synchronous Generator Ground / Earthing MCCB : Moulded Case Circuit Breaker MCB : Miniature Circuit Breaker Contactor Diesel Generator Set 50 kva, 400 V 3 Phase, 50 Hz, 0.8 PF XLPE Cable: 1.1 kv 1 3.5 50 mm² DG AMF RELAY V/TD V V/TD V VSS VSS A/TD A A/TD A ASS ASS 51 51N 86 51 51N 86 ELECTRICAL INTERLOCK 400 V Station Auxilliary Supply LEGEND: AVR Automatic Voltage Regulator VSS Voltage Selector Switch ASS Current (Ampere) Selector Switch S Synchroscope C1 Contactor EI Electrical Interlock V Voltmeter A Ammeter W Wattmeter F Frequency meter Wh Active energy (Watt hour) meter VAR Reactive power meter PF Power Factor meter V/TD Voltage transducer A/TD Ampere Transducer W/TD Watt Transducer PROTECTION DEVICE NUMBER 21 Distance Relay 24 Volts/Hz Relay 25 Synchronism Check Relay 26 Apparatus thermal device 27 Undervoltage Relay 32P Directional Power Relay 40 Field Relay 46 Reverse phase or phase balance current relay 49 machine or transformer thermal Relay 50 Instantaneous overcurrent Relay 50/51 Instantaneous ac time overcurrent Relay 51N Neutral ac time overcurrent Relay 51T Transformer overcurrent Relay 51NT Transformer neutral overcurrent Relay 51V Voltage Controlled overcurrent Relay 59 Overvoltage Relay 64T Transformer Ground detector Relay 78 Phase angle measuring Relay 81 Frequency Relay 87G Generator differential protective Relay 87T Transformer differential protective Relay 95 Trip Circuit Supervision Relay LBB Local Backup Protection Relay SUNDARIJAL HYDROPOWER PLANT-REHABILITATION PROJECT FOR TENDER PURPOSE ONLY