SERIES SF2-250 SUCTION FILTER. Flow rate to 45 gpm

Similar documents
OUT. The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter

D e s c r i p t i o n

SERIES SF2-500 SUCTION FILTER. Flow rates to 225 gpm

A complete line of pressure differential visual and electrical indicators are available with this series of filters.

MPF filters within this range are suitable for flow rates up to 750 l/min.

FMP IN-LINE FILTER SERIES. Maximum working pressure 250 bar. Flow rate to 500 l/min

SPIN-ON FILTER - LOW PRESSURE LINE

A complete line of pressure differential visual and electrical indicators are available with this series of filters.

MPS/MST SERIES SPIN - ON FILTER SUCTION - RETURN. Maximum working pressure 12 bar. Flow rates to 300 l/min

SERIES FRI. Maximum working pressure 20 bar Flow rate to 1200 l/min. s.p.a

D e s c r i p t i o n

SERIES. Maximum pressure 110 bar

THE IMPORTANCE OF AN EFFICIENT FILTRATION

FILTERS. PUMP CARE - Suction filters TECHNICAL DATA ORDERING AND OPTIONS CHART CLOGGING INDICATORS. PRESSURE DROP ( p) CURVES CROSS FUNCTIONAL VIEW

NEW. High Pressure filters. FMM 150 series. Maximum pressure up to 420 bar - Flow rate up to 250 l/min

In line high pressure filters. HF 735 series

Filtrec elements are tested according to ISO 2941, ISO 2942 and ISO 23181

In line high pressure filters. HF 725 series

Fluid Cooling Industrial COLW Series

MPH Maximum pressure 10 bar F l o w r a t e s t o l / m i n

MPH Maximum pressure 10 bar F l o w r a t e s t o l / m i n

RF2 Maximum pressure 20 bar F l o w r a t e s t o l / m i n

In line high pressure filters. HF HF 761 series

THE IMPORTANCE OF AN EFFICIENT FILTRATION

FHA 051 Working pressure 6000 psi

Filter. Rücklauffilter 3-Loch Serie HF 502. Bestellnr. Innengewinde G. Code. Typ. (ohne Filterelement)

By-pass: 1,7 bar (24.6 psi) setting N.B. Cartridge with integrated bypass valve and antidrainback membrane

Pressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T ) Buna-N (FKM on request)

Pressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T )

Return fi lters. FRI series. Maximum pressure up to 20 bar - Flow rate up to 1500 l/min. Return fi lters

FMM bar. Working pressure. Style T. Style D. Style S. Style B D.I. D.I. D.I. D.I.

SPIN-ON FILTERS & ELEMENTS

Filter. Spin-on Filter. Spin-on Filterelement Serie HF 620. Innengewinde. Bestellnr. (ohne Filterelement) Code. Typ

Working pressure. 350 bar. Style B Series FHD 051. Series FHD 325/332 D.I. D.I. D.I. A A

Filter. Spin-on Filter. Spin-on Filterelement Serie HF 620. Innengewinde. Bestellnr. (ohne Filterelement) Code. Typ

The range of products is completed by a number of accessories, including:

Pressure: Max working 280 bar (4000 psi) (acc. to NFPA T ) Burst 840 bar (12200 psi) (acc. to NFPA T )

Return Line Filter HF4R up to 450 l/min, up to 10 bar

Flow rates to 500 l/min

Inline Filters NF. Flow rates up to 3,500 l/min Pressure range 25 bar Material: Aluminium / Aluminium-Cast Iron

Pressure: Max working 110 bar (1600 psi) (acc. to NFPA T ) Burst 330 bar (4800 psi) (acc. to NFPA T ) Wire mesh µm

Connection Ports: 1/2 1 1/2 BSP (other thread options on request) aluminium alloy NBR (FKM on request)

The range of products is completed by a number of accessories, including:

LDP & LDD series Filter element according to DIN Maximum working pressure up to 6 MPa (60 bar) - Flow rate up to 330 l/min

THE IMPORTANCE OF AN EFFICIENT FILTRATION

Pressure: Max working F280 D12x port size 1/2 & 3/4 : 420 bar (6000 psi) Burst F280 D12x port size 1/2 & 3/4 : 1260 bar (18000 psi)

RETURN FILTERS. MATERIALS Head: Aluminium alloy Spin-on cartridge: Steel Bypass valve: Polyammide Seals: NBR Nitrile Indicator housing: Brass

DIN Filter element according to DIN Low & Medium Pressure filters. Maximum pressure up to 60 bar - Flow rate up to 330 l/min

Connection Ports: 3/4 1 1/4 BSP (other thread options on request)

Connection Ports: 3/4 1 1/4 BSP (other thread options on request) aluminium alloy NBR (FKM on request)

Pressure Filter for Manifold Mounting DFP and for Reversible Flow DFPF

STAUFF STAUFF. Local solutions for individual customers worldwide. Return Line Filters RTF FILTRATION TECHNOLOGY. Ordering Code # :SFT A - UK

Suction Filter SF/SFM/SFF and Suction Filter Elements S/S..

Series RFL In-Line Filter

525 Stainless steel high pressure filters. FZP series. Maximum pressure up to 420 bar. Stainless steel high pressure fi lters

HIGH PRESSURE FILTERS

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800)

High Pressure fi lters. FHP series. Maximum pressure up to 420 bar - Flow rate up to 750 l/min. High Pressure fi lters

Flow rates to 3000 l/min

Low Pressure Filters

Return Line Filter RF

Duplex Pressure Filters

Change-Over Pressure Filter DFDK

FHF325 series. Filter housing according to SAE J2066 for HF4 filter elements. High Pressure fi lters

FILTERS. TANK CARE - Return filters TECHNICAL DATA ORDERING AND OPTIONS CHART CLOGGING INDICATORS. PRESSURE DROP ( p) CURVES CROSS FUNCTIONAL VIEW

Pressure Filter DF...K P, DF...M P, Flange Mounted

HIGH PRESSURE FILTERS

Check Type Prefill & Exhaust Valves

RETURN FILTERS. MATERIALS Head: Aluminium alloy Cover & bowl: Polyammide Bypass valve: Polyammide Seals: NBR Nitrile Indicator housing: Brass

LMP series

Return Line Filter RF

LMP series. 305 Low & Medium Pressure filters MULTIPORT. Maximum pressure up to 80 bar - Flow rate up to 200 l/min

Suction Filter SF/SFM/SFF and Suction Filter Elements S and S..

Stainless Steel Pressure Filters

Oil Solutions. Tank Top Return Filters RTF. Local solutions for individual customers worldwide FILTRATION TECHNOLOGY

High-pressure inline filter, flangeable

Line filter with filter element according to DIN 24550

HIGH PRESSURE FILTERS HF4P Series Inline Filters 5000 psi up to 120 gpm

HIGH PRESSURE FILTERS

Inline Filter LPF D A Flange-Mounted up to 280 l/min, up to 25 bar

Hydraulic Filtration. Product Range. Low & Medium Pressure Filters. Return Filters MPFX MPTX MFBX. China United Kingdom India Canada

SRK-COMBO. Return & Suction Filters Low Pressure Filter In-Tank up to 10 bar. Filter Elements Emergency Suction

Series TSW Sheet No J. SUCTION FILTER, horizontal tank mounted. Dimensions: mounting surface

Suction Filters S8-455 SE56-560

Return Line Filter RFM with 4-Hole Mounting

Block mounting filter, for lateral flange-mounting

Pressure Filter DF Pressure Filter for Reversible Oil Flow DFF/DFFX

Series RFLD Duplex In-Line Filter

Pressure: Max working 160 bar (2300 psi) (acc. to NFPA T ) Burst 480 bar (6900 psi) (acc. to NFPA T )

Inline Filter RFL. Cast version Volume rates up to 1300 l/min* Pressure range 25/40 bar

Filtrec elements are tested also according to ISO 2942, ISO and ISO 3968

Block mounting filter, for vertical flange-mounting

Inline filters NF NF 1350 NF 330 NF 750 NF 500 NF FILTER SPECIFICATIONS Nominal pressure

Block mounting filter, lateral flange-mounting possible

Inline Filter RFLD. Change-Over. Cast Version Flow Rates up to 1300 l/min* Pressure Range 25/40/64 bar With Ball Change-Over Valve E /01.

Block mounting filter, for lateral flange-mounting

HIGH PRESSURE FILTERS DFFX Series Reverse Flow Differential Pressure Optimized Filters 6090 psi up to 160 gpm

Pressure: Max working 420 bar (6000 psi) (acc. to NFPA T ) Burst 1260 bar (18300 psi) (acc. to NFPA T )

ENGINEERING DATA. Quick Reference Chart. Variable Volume Vane Pumps Models SV-20 & SV-25 Flange & Subplate Mounted. Industrial Hydraulics

BENT AXIS PISTON MOTORS SERIES HPM FLANGE ISO HPM. pag.3

Transcription:

SERIES SF2-250 SUCTION FILTER Flow rate to 45 gpm

D e s c r i p t i o n 250 The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter within the filter preventing oil loss from the reservoir. The SF2 250 filter uses a vacuum gauge or electrical vacuum switch for filter element indication. element to be replaced without having to drain the These filters are particulary suitable for power pack, oil from the reservoir. mobile, construction and industrial machinery application. Unscrewing the filter cover operates a shut off valve COVER INDICATOR OPTIONS HEAD ELECTRICAL OUT FILTER ELEMENT. VISUAL BYPASS VALVE UNI EN ISO 9001 N 037/98 SHUT OFF VALVE IN OPTIONAL MAGNET COLUMN ON REQUEST SF2 250 01040/2.00/USA 2

MP Filtri - Filtration Technology Filter element: Materials End caps: Nylon Support tube: Steel Support frames: Expanded metal Element material Nominal filtration MSeries Square wire mesh (filtration degree is defined in microns by the maximum diameter of a sphere corresponding to the mesh size). Filtering area Filter elements Type SF2 250 M25 M60 M90 M250 310 310 310 310 Values in IN 2 Filter body: Materials Head Pressure die cast aluminium Cover Nylon Seals A Series: Nitrile (Buna-N) V Series: Viton Indicator Brass Working temperature From -13 to +230 F For temperature outside this range, please consult our Sales Network Organization Bypass valve Setting pressure Bypass valve, differential opening pressure: 4.5Psi ± 10% 3

MP Filtri - Specification Compatibility with fluids Filter head and bowls compatible for use with: mineral oils (types HH-HL-HM-HR-HV-HG as per ISO water-based emulsions (types HFAE-HFAS as per ISO synthetic fluids (types HS-HFDR-HFDS-HFDU as per ISO water-glycol (types HFC as per ISO Ask for anodised version Filter elements As per ISO 2943; suitable for mineral oils (types HH-HL-HM-HR-HV-HG as per ISO synthetic fluids (A and M series only) (types HS-HFDR-HFDS-HFDU as per ISO For water-based emulsions (type HFAE-HFAS as per ISO and fluids other than those mentioned, please consult our Sales Network Organization. Seals A Series Nitrile (Buna-N) compatible with mineral oils (types HH-HL-HM-HR-HV-HG as per ISO water - based emulsions (types HFAE-HFAS as per ISO V Series Viton compatible with synthetic fluids (types HS-HFDR-HFDS-HFDU as per ISO Types of indicator Visual indicator Description: SF2 250 series filters are fitted with visual and electrical indicators. V Series (radial) V0 Series (axial) vacuumeter: scale 0-30 In HG vacuumeter: scale 0-30 In HG Electrical indicator E1 Series: vacuum switch with change-over contacts (setting std. 3 Psi ± 10%) (adjustable setting: 2.5 to 12.5 Psi) Operational information: Max voltage: 250 V 50 60 Hz Max current: 5 A resistive, 2 A inductive. Protection degree IP65 V0 V E1 ø 1.96 2.32 A/F.67 ø 1.57 2.56 1.18x1.18 Revolving 1.34 1/8 NPT 1.26 A/F.55 PG.43 Cable entry gland 1/8 NPT 9 1/8 NPT A/F.75 4

Selection & installation information Filter element types M Series Metal mesh media, available in 25, 60, 90, 250 micron Example - M25, M60, M90 and M250 Please refer to individual pressure drop curves to obtain filter assembly pressure drop information The following filter sizing recommendations are based using a mineral oil fluid at 150 SUS with a maximum total filter assembly (housing and filter element) pressure drop of 1.15 Psi. SF2 SERIES 250 SIZE 4.8 1/8 NPT 3.23 1.69 13.78 OUT 1.406 ±.01 SF2 250 D1 Filter element M25 M60 M90 M250 option 1 * 26 26 26 26 option 1 1/4 * 37 37 40 40 Flow rate gpm option 1 1/2 37 40 43 43 ** Flow rates are based using a mineral oil fluid at 150 SUS. ** Weight including filter element Weight Lbs ** 6.35 2.75 ±.01 15 ø 4.49 Thread connections Type A Type A G1 1 1/2 BSP G6 SAE 20 G2 1 1/2 NPT G7 1 BSP G3 SAE 24 G8 1 NPT G4 1 1/4 BSP G9 SAE 16 IN G5 1 1/4 NPT 5.51 R.217 90 Flange connections Type A D1 F1 1 1/2 SAE M12 3000PSI/M 5.51.43 A F2 1 1/2 SAE 1/2 UNC A 3000PSI/UNC ø 5.9 ±.01 HOLES ON THE TANK 90 ø 6.5 ±.01 Filter housing pressure drop SF2 250 1,5 1 1 1/4 1 1/2 45 IN Ø 4.53 p Psi 1,0 0,5.39 No. 4 Holes Ø 5.9 min Ø 6.5 max 0 0 15 30 45 60 5

Pressure drop information General Pressure drop versus flow rate curve information for both housing and filter elements is in accordance with ISO 3968 Filter assembly pressure drop - p Total = p Housing + p Filter element Housing pressure drop - The housing pressure drop is proportional to the fluid density Filter element pressure drop - Filter element pressure drop is proportional to kinematic viscosity therefore always check the fluid operating temperature and fluid type to obtain the working viscosity according to the following formula: p1 Filter element = (working viscosity/brochure viscosity) x p filter element Brochure viscosity = 150 SUS Filter assembly sizing example Selection Customer requires a 37 gpm filter assembly 1 1/2 port size Mineral oil fluid: ISO VG 46 (212 SUS) at 104 F) M90-90 micron filtration Housing pressure drop - SF2 250 (1 1/2 port size) with 37 gpm p = 0.75 psi (see curve on page 5) Filter element pressure drop (brochure viscosity) - SF2 250 M90 N with 37 gpm p = 0.1 psi (see curve on page 6) Filter element pressure drop (working viscosity) - With 212 SUS p 1 = 0.1 x (212/150) = 0.14 psi Filter assembly pressure drop p Total = p Housing + p 1 Filter element = 0.75 + 0.14 = 0.89 psi* { * Acceptable pressure drop as per our recommendations Filter element pressure drop 0.3 M25 p psi 0.2 0.1 M60 M90 M250 0 7.5 0 15 30 45 60 Bypass valve pressure drop p psi 5.0 2.5 0 0 7.5 15 22.5 30 6

SF2 Ordering code example 250 A G1 H M25 VS This example shows how order a filter assembly with features based on the customer request. 250 Nominal size Filter condition indicator S With threaded hole only T1 With hole + plug V0 Visual (axial vacuumeter) VS Visual (radial vacuumeter) E1 Electrical (change-over contacts vacuumeter) Seals Filter elements A V Nitrile (Buna-N) Viton M25 M60 M90 M250 Square wire mesh Type G1 G2 Port option SF2 250 1 1/2 BSP 1 1/2 NPT H R S Q Options Without By-pass, without magnet With By-pass and magnet With By-pass, without magnet Without By-pass and magnet G3 SAE 4 G4 G5 G6 G7 G8 G9 F1 F2 1 1/4 BSP 1 1/4 NPT SAE 20 1 BSP 1 NPT SAE 16 1 1/2 SAE 3000 PSI/M 1 1/2 SAE 3000 PSI/UNC Seals (only for filter elements) N Buna N V Viton SF 250 M25 N This example shows how order a filter element with features based on the customer request Replacement element MP Filtri - Filtration products will only be guaranteed if original MP Filtri replacement elements and spares are used Data held in this publication is given only for indicative purposes. MP Filtri reserves to introduce modifications to described items for technical or commercial reasons. Copyright reserved. 7

Head Quarter : MP FILTRI S.p.A. Italy Via Matteotti, 2 20060 Pessano con Bornago (Milano) Italy Tel. ++39.02/95703.1 Fax ++39.02/95741497-95740188 email: sales@mpfiltri.com http://www.mpfiltri.com GREAT BRITAIN MP FILTRI U.K. Ltd. Bourton Industrial Park Bourton on the Water Gloucestershire GL54 2HQ UK Phone: 01451-822522 Fax: 01451-822282 email: sales@mpfiltri.co.uk http://www.mpfiltri.co.uk GERMANY MP FILTRI D GmbH Am Wasserturm 5 D-66265 Heusweiler/Holz Phone: 06806/85022-0 Fax: 06806/85022-18 email: mpfiltrink@aol.com FRANCE MP FILTRI FRANCE B.P. 325 01603 Trevoux Cedex Tel: 04.74.08.84.78 Telefax: 04.74.08.80.45 email: mpfiltrifrance@wanadoo.fr USA MP FILTRI USA Inc. 2055 Quaker Pointe Drive Quakertown, PA 18951 Phone: 215-529-1300 Fax: 215-529-1902 email: mpusasales@aol.com http://www.mpfiltriusa.com CANADA MP FILTRI CANADA Inc. 210 Jacob Keffer Parkway Concord, Ontario Canada L4K 4W3 Phone: 905-303-1369 Fax: 905-303-7256 email: mail@mpfiltricanada.com http://www.mpfiltricanada.com