FOR PRICES ON DSII and DSLII BREAKERS, REFER TO PRICE LIST PL.22B.01.P.E

Similar documents
Instruction Bulletin. DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Class 6035

Page 2 DS LOW VOLTAGE POWER CIRCUIT BREAKERS Digitrip Trip Unit Inside Wiring Guide Outside Wiring Guide Shutter Drawout Unit Position Indicator Escut

DS/DSII Low Voltage Switchgear. Renewal Parts. Cutler-Hammer. Renewal Parts. Effective: October Page 1

VacClad-W type VCP-W 5 and 15 kv, 36-inch-wide switchgear components

T- VACR Fixed (up to 40kA) T-VAC Draw out (up to 40kA)

Instructions for Installation, Operation and Maintenance of Low Voltage Power Circuit Breakers Types DSII and DSLII

TYPES DS II AND DSL II METAL ENCLOSED LOW VOLTAGE POWER CIRCUIT BREAKERS

Instructions for the Use, Operation and Maintenance of Types VCP-TL and VCP-TRL Linear Magnetic Vacuum Circuit Breakers

Low Voltage Switchgear Type WL Low Voltage Metal-Enclosed Switchgear

Controlled Power HSN High Speed DC Circuit Breakers

Digitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers

Advance design OEM L-Frames, cell kits, & enclosures Metal-clad switchgear components OEM catalog & pricing

Medium Voltage Metal-Enclosed Switches

Medium Voltage Metal-Enclosed Switches

POWER-ZONE 4 Low Voltage Metal-Enclosed Drawout Switchgear with MASTERPACT NW Low Voltage Power Circuit Breakers

Power Break II Switchboard

Digitrip Retrofit System for the ITE LG-3000 (Frameless) Circuit Breaker

3.1. Power Breakers, Contactors and Fuses. Contents. Series NRX Low Voltage Power Circuit Breakers. Power Circuit Breakers

Switchgear. Low Voltage

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

ATLV MaxSG. Low Voltage Metal Enclosed Switchgear

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

.1 Low Voltage Switchgear Magnum DS Switchgear with Molded Case Circuit Breaker Feeder Section Cross-Reference Eaton s Electrical Sector has an organi

Cutler-Hammer May 2001

WLI Medium Voltage Switchgear Renewal Parts

Design Standard. Purpose: Design Standard:

Table Line and Load Terminals. Terminal Body Material. Wire Type. Aluminum Copper Aluminum. English English English.

University of Houston Master Construction Specifications Insert Project Name

DEF 005. WavePro Power Circuit Breakers A Frames, Vac. Renewal Parts

Magnum IEC Low Voltage Air Circuit Breakers

Horizontal Circuit Switchers

Frame Sizes: AKJ/ AKJT I AKJU-50 and AKR/ AKRU-30/ 50, AKRT-50

Horizontal Circuit Switchers

www. ElectricalPartManuals. com It'll Cutler-Hammer WLI Medium Voltage Switchgear Renewal Parts Renewal Parts Data Page 1

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

SECTION 16426B. RELATED SECTIONS Section 16671A Transient Voltage Surge Suppression Section Microprocessor-Based Metering Equipment

17.1. Low Voltage Switchgear. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents

Specification Guide. for RMVAC. Direct Replacement. AC Medium Voltage. Circuit Breakers

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation

Low Voltage Switchgear

Medium voltage switchgear SafeGear HD 63 ka arc resistant metal-clad switchgear. ABB Group February 25, 2015 Slide 1

1VAL2401-SG Rev D. Spare parts list for Outdoor Products Reclosers, breakers, & padmount switches

www. ElectricalPartManuals. com

Specification Guide. for RMAX. Direct Replacement. AC Low Voltage. Power Circuit Breakers

www. ElectricalPartManuals. com Cutler-Hammer Power Breaker Center Renewal Parts for Low Voltage Power Circuit Breakers Types DB, DBL and DBF

Power/Vac OEM Express Switchgear

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

SECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT

www. ElectricalPartManuals. com Instructions for Field Testing of Ground Fault Systems Utilizing Cutler-Hammer Magnum DS Circuit Breakers

Critical Power Switchboards. Selection and Application Guide

www. ElectricalPartManuals. com Digitrip Retrofit System for Allis-Chalmers LA-4000 F Fused Breakers IL 33-A1K-1 WARNING

Table Types LD, HLD and LDC Thermal-Magnetic Circuit Breakers with Interchangeable Trip Units

www. ElectricalPartManuals. com Section 13 Switchgear Low Voltage

Digitrip Retrofit System for Allis-Chalmers G-25 Breakers

Medium Voltage Equipment 5-15 kv GM-SG and 38 kv GM38 Metal-Clad Switchgear General

A. Submit manufacturer's literature and technical data before starting work.

SWITCHGEAR DIVISION PRODUCT PROFILES

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS

Type SDV6 distribution circuit breaker. Top performance - proven reliability. Answers for energy.

GE Industrial Solutions. User/Installation Manual for 4.76kV -15kV SecoBloc

30 ma Ground Fault (Earth Leakage) Modules. Product Description

www. ElectricalPartManuals. com Digitrip Retrofit System for BBC LKD 8 Breakers IL 33-LK8-2

VCP-T/T-VAC medium voltage vacuum circuit breakers. Control and protect with Eaton s compact medium voltage circuit breakers

Service Entrance Methods

PRICING. Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products. Class 600. October 2004

Cutler-Hammer. Instructions for Potential Transformer and Auxiliary Control Power Disconnecting Means for Use in Ampgard Lineups, 7.2 kv I.B.

Explosion Proof Receptacle - Integral Circuit Breaker - Class 2 Division 1-30 Amp 480VAC

Cutler-Hammer. Instructions for Installation, Operation, and Maintenance of the AMPGARD Reduced Voltage Soft Starter

Ampgard medium voltage motor control renewal parts

Cutler-Hammer INSTRUCTIONS FOR MAGNUM DS METAL-ENCLOSED LOW-VOLTAGE SWITCHGEAR ASSEMBLIES WITH MAGNUM DS BREAKERS IB E

www. ElectricalPartManuals. com Digitrip Retrofit System for the Westinghouse DA-50 IL 33-DAC-2 WARNING

VersaRupter 5-38 kv Load Interrupter Switch. Technical Guide

Digitrip Retrofit System for BBC LKD 8 Breakers

SIEMENS. Series 8100oT Vacuum Controllers. www. ElectricalPartManuals. com. Bulletin CC

Digitrip Retrofit System for General Electric AKR/AKRU-6D/7D-30S Series Breakers

www. ElectricalPartManuals. com Type AM Magne-Biast Circuit Breakers RENEWAL PARTS

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

Digitrip Retrofit System for Siemens-Allis RLX-1600 Breakers

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

UBC Technical Guidelines Section Edition Commissioning of Electrical Systems Page 1 of 5

DANGER. Instruction Bulletin WARNING. Shunt Trip Kit for Manual DS/DSL Circuit Breakers POWER ZONE III Low Voltage Switchgear Class 6035 INTRODUCTION

Magnum IEC Air Circuit Breakers and Drawout Cassette Engineering Data

www. ElectricalPartManuals. com GENERAL. ELECTRIC RENEWAL PARTS METAL-CLAD SWITCHGEAR TYPES M-26 AND M-36 GEF-4351C Supersedes GEF-4351B

Design Build Deliver. Metal Enclosed Switchgear, 5-35kV 1200 A Maximum Loadbreak, 4000 A Maximum Non-Loadbreak

Low-Peak 600V Class RK1

MASTERCLAD Metal-Clad Indoor Switchgear

GE 8000-Line Motor Control Centers Mains, Feeders, Incoming Lines C-1

SECTION MICROPROCESSOR TRIP UNITS FOR LV CIRCUIT BREAKERS. This section is organized as indicated below. Select desired Paragraphs.

DBR Receptacle Class II, Division 1 and 2, Groups F, G Class III NEMA 3, 3R, 4, 4X, 9FG

BBC. Renewal Parts. I-T-E Low-Voltage Power Circuit Breakers

with Vacuum Circuit Breaker HAF

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

SafeGear TM Motor Control Center Arc resistant metal-clad construction

Product Line Overview. The Most Logically Designed Contact Assembly

5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application

ADVAC - Advanced Design Vacuum Circuit Breakers Technical Guide

Digitrip Retrofit System for Allis-Chalmers LA-600 F Electrically Operated Fused Breakers

Transcription:

Supersedes PL.44B.04.P.E Dated September 1998 600 Volts AC Maximum 200 ka, RMS Sym. Short Circuit Maximum 800-5000 Amps Continuous Effective: October 1999 Page 1 Index Page Table Description/Application... 1... Erector Set Concept... 2-3... 1 Erector Set Parts... 4-7... 4 Glossary of Terms... 3... 2 High Resistance Ground... 8... 5 Ordering Information... 1... Pricing Instructions... 1... Substructures... 4... 3 Description and Application Switchgear Power Circuit Breakers are ideally suited to applications calling for service entrance switchgear, secondary equipment in coordinated secondary substations and auxiliary control and distribution switchgear by all types of industrial, commercial and utility users. These cell parts have a proven history of reliable circuit protection and control. offers a complete line of DSII breakers rated from 800 to 5,000 Amperes. These breakers come standard with the state-of-the-art true RMS sensing Digitrip trip units to provide specific tripping characteristics. Refer to PL.22B.01.P.E for breaker prices. Pricing Instructions This price list is to be used exclusively for pricing low voltage switchgear cell parts for use by an OEM in the completion of a total switchgear assembly. The price list is divided into tables which offer the OEM cell parts requiring varying levels of added value. The Substructure (Table 3) offering is suited to the customer that has the capability of some steel fabrication and an increased amount of engineering and assembly. The Erector Set Parts (Table 4) is most suited for the OEM with extensive capabilities of engineering, assembly and fabrication. Some style numbers in Table 4 have minimum order quantities as shown under the column headed Min Qty. The price listed in the List column is for style number only, not the price for the minimum quantity. All quotations from this price list will be per SP 25-000. Discount Symbol CE5D applies. Ordering Information When ordering Substructures, order by the appropriate style number from Table 3. Note that style number 2A89058G02 push to trip kit should be ordered separately. This kit is shown in the first section of Table 4. Note that for a complete DSLII-632 or DSLII-840 unit, you must order the breaker cell style number plus the style number for the corresponding fuse truck cell. For example, for a complete DSLII-632 with rear bus extensions, order style 567F960G02 for the breaker cell and style 568F200G11 for the fuse truck cell. In addition, note the requirements as given in footnotes 1 and 2 for DSLII cells. When ordering Erector Set Parts, order by the appropriate style number for the parts that are needed from Table 4. Table 1 gives a listing of the style numbers and quantities needed for a basic breaker cell of each of the DSII and DSLII frames. Note that some style numbers have minimum order quantities as shown under the column headed Min Qty. The price listed in the List column is for style number only, not the price for the minimum quantity. The order entry suffix is Q29 for all registered style numbers. FOR PRICES ON DSII and DSLII BREAKERS, REFER TO PRICE LIST PL.22B.01.P.E

Page 2 Effective: October 1999 Table 1: Erector Set Concept The erector set concept allows an OEM maximum flexibility in his manufacturing process. It provides all the parts and pieces necessary to build a complete unit allowing the OEM to choose those which he would like to manufacture and those which he would like to purchase. For the total erector set styles and quantities needed for a basic breaker cell, select from section 1 plus section 2 or 3 depending upon the type molded stab support being used. All accessory items are not shown. THE FOLLOWING PARTS ARE COMMON FOR 1, 2, AND 3-PIECE MOLDED STAB SUPPORTS DSII Breaker Frame DSLII Breaker Frame Style # Description 308 508 608 516 616 620 632 FT32 840 FT40 850 308 516 620 ➂ 9247C71G02 Breaker Mounting Pan... 1... 9247C71G04 Breaker Mounting Pan... 1... 9247C71G06 Breaker Mounting Pan... 1... 9247C71G03 Breaker Mounting Pan... 1... 9247C71G05 Breaker Mounting Pan... 1... 1... 8650C01G01 Breaker Mounting Pan... 1... 8650C02G01 Breaker Mounting Pan... 1... 9247C72G02 Breaker Mounting Pan... 1... 9247C72G03 Breaker Mounting Pan... 1... 9246C77G01 Breaker Mounting Pan... 1 568F126G06 Breaker Mounting Pan Kit... 1... 568F211G07 Breaker Mounting Pan Kit... 1... 8649C21H01 Secondary Contact Mounting Pan... 1... 1... 1... 1... 1... 1... 1... 1... 1... 1... 1 2A89533G02 Secondary Contact Mounting Pan... 1... 1... 2A89641G01 Cell Secondary Contact Bloc k Kit... 1... 1... 1... 1... 1... 1... 1... 1... 1... 1... 1... 1... 1 2A89650G03 Communications and ZI Port.. ➁... ➁... ➁... ➁... ➁... ➁... ➁... ➁... ➁... ➁... ➁... ➁... ➁ 690C950H01 Arc Shield... 1... 1... 1... 1... 1... 1... 1... 1... 1... 1 795A386G02 Arc Shield... 1... 3583A90H01 Gas Shield, Horizontal... 1... 1... 1... 1... 1... 1... 1... 1... 1... 1 6469C96H01 Gas Shield, Horizontal... 1... 8294A65H01 Gas Shield, Vertical... 2... 2... 2... 2... 2... 2... 2... 2... 8294A66H01 Gas Shield, Vertical... 2... 2 8294A67H01 Gas Shield, Vertical... 2... 2A89058G02 Push to Trip Kit➃... 1... 1... 1... 1... 1... 1... 1... 1... 1... 1... 1 THE FOLLOWING PARTS ARE USED WITH 2 OR 3-PIECE MOLDED STAB SUPPORTS DSII Breaker Frame DSLII Breaker Frame Style # Description 308 508 608 516 616 620 632 FT32 840 FT40 850 308 516 620 ➂ 567F908G01 Molded Stab Support... 2... 2... 2... 2... 2... 2... 2... 2... 567F910G01 Molded Stab Support... 2... 2... 2 436B112H01 Molded Stab Support... 3... 3... 435B632H01 Cell Stabs... 6... 6... 809A476H01 Cell Stabs... 6... 6... 6... 6... 6... 6... 809A482H01 Cell Stabs... 6... 6... 6 114B453H01 Cell Stabs... 12... 12... 809A493H03 Bus Spacer Plate... 6... 6... 6... 6... 6... 6... 6... 6... 3582A07H01 Bus Spacer Plate... 6... 6... 6 1944C01H01 Runback Support... 1... 1... 114C738H01 Cell Stab (Riser Bus) Support Bracket... 6... 6... 436B057H01 Rear Bus Extension... 12... 12... 436B056H01 Rear Bus Extension... 12... 12... 12... 12... 12... 12... 588C948H01 Rear Bus Extension... 12... 12... 12 588C944H01 Rear Bus Extension Insulator.. 1... 1... 1... 1... 1... 1... 1... 1... 1... 1... 1 19D8888H02 Rear Bus Extension Insulator Mounting Bracket... 2... 2... 2... 2... 2... 2... 2... 2... 2... 2... 2 1 Number ordered must be the same as supplied on the breaker. ➁ One is required if communications or zone interloc king is needed. ➂ DSII-850 is available in Power Modules only. Refer to. ➃ Style number is for 10 kits

Effective: October 1999 Page 3 Table 1: Erector Set Concept, Continued THE FOLLOWING PARTS ARE COMMON FOR 1-PIECE MOLDED STAB SUPPORTS DSII Breaker Frame DSLII Breaker Frame Style # Description 308 508 608 516 616 620 632 FT32 840 FT40 850 308 516 620 1 449D395G01 Molded Stab Support... 1... 1... 1... 1... 1... 1... 1... 1... 567F384G01 Molded Stab Support... 1... 1... 1 449D465H01 Runback Support... 1... 1... 1... 1... 1... 1... 1... 1... 449D371H01 Runback Support... 1... 1... 1 5501A17G01 Riser Bus Stab... 3... 3... 750A035G02 Riser Bus Stab... 3... 3... 3... 3... 3... 3... 750A040H01 Riser Bus Stab... 3... 3... 3 8644C76G02 Load Runback... 3... 3... 3 8644C76G06 Load Runback... 3... 3... 3... 3... 3... 3... 8644C77G01 Load Runback... 3... 3... Table 2: Glossary of Terms Arc Shield Horizontal insulating barrier located above each breaker to prevent the propagation of ionized gases. Breaker Levering Tool Used to engage the breaker into the cell. Breaker Lifter Assembly Mounted on top of switchgear assembly to lift breaker on or off the rail extensions of the Breaker Mounting Pan. Breaker Mounting Pan Mechanism to position the breaker in the cell. Bus Spacer Plate Current carrying part that mounts on the 2-piece Molded Stab Support. Cell Stabs and Rear Bus Extensions are mounted to this piece, also. Cable Interlock Kit For mechanically interlocking 2 adjacent breakers in the same structure. Breakers must be specially ordered to accept this feature. Cell Secondary Contact Block Kit Interface between the cell and breaker control wiring. Kit includes one 12-finger control block and hardware to mount the block. Four is maximum number of blocks allowed per cell. Cell Stabs Power interface between the cell and breakers. The breaker finger clusters mate with these stabs to complete the power circuit. With the 2-piece Molded Stab Support system, these stabs mount to the bus spacer plate. With the 1 and 3-piece Molded Stab Support system, these protrude through the Molded Stab Support and connect directly to the assembly bus system. Cell Switch Kit Switch that is operated by the movement of the breaker in the cell. Communications and ZI Port Interface between the cell wiring and the breaker for communication of ground fault, breaker, trip unit and other system information. Digitrip/Amptector Test Kit Adapter Used for testing the breaker trip unit functions. Gas Shield, Horizontal/Vertical Located in the breaker cell to mate with the breaker dead front cover in the connected position. Restricts the ionized gases from exiting the cell. Insulating Boots Used to cover the Cell Stabs or Riser Bus Stabs in a cell provision to prevent accidental contact. For use in Substructures or Erector Set Parts. Key Interlock Provision There are 3 types of interlocks. Locks breaker out prevents the breaker from being in any position except the remove position. Trip Free allows the breaker to be in any position in the cell but the breaker cannot be closed. Finally, an interlock is required on the fuse truck door keyed with its associated breaker to prevent the fuse truck door from being opened when its associated breaker is closed. Lifter Rail Guide Assembly Front and rear track assembly for the Breaker Lifter Assembly. Lifting Yoke for Portable Lift Truck Mechanism to attach the cable to the breaker. Provided as standard on the Breaker Lifter Assembly. Load Runback Used only with the 1 or 2-piece Molded Stab Support. Interfaces between the breaker load finger cluster and the customer cables. Can also be used on the line side for incoming cable. Molded Stab Support Molded glass polyester piece that mounts in the rear of the cell and supports the line and load power bus interface to the breaker. There are three different Molded Stab Support types 1, 2 and 3-piece. Portable Lift Truck Accomplishes the same function as the Breaker Lift Assembly except that it rolls on the floor. Push to Trip Kit Consists of a flapper, hinge and label. Mounted on the cell door and interfaces with the push to trip mechanism. Rail Stop Mounts on extreme left and right end of Lifter Rail Guide Assembly to provide a stop point for the breaker lifter. Rear Bus Extension Used with the 2-piece Molded Stab Support. Connects to the Bus Spacer Plate mounted on the Molded Stab Support. Rear Bus Extension Insulator Electrically isolates the line and load Bus Spacer Plates. Used and required with the 2- piece Molded Stab Support. Rear Bus Extension Insulator Mounting Bracket Bracket for Rear Bus Extension Insulator. Riser Bus Stab Used on the line side of the breaker as the interface between the breaker finger cluster and the vertical riser bus. Can also be used on the load side of a tie breaker. Used with the 1 and 3-piece Molded Stab Support. Riser Bus Support Mounted on the rear of the cell back plate to support the riser bus. Riser Bus Support Bracket Bracket for the Riser Bus Support. Runback Support Support for the Load Runbacks. Secondary Contact Mounting Pan Cell Secondary Contact Block is mounted to this pan which in turn is mounted to the cell back plate. Supplied as standard in Substructures. Shutter Isolates line and load Cell Stabs from incidental contact when the breaker is removed from the cell. Test Cabinet Used for testing the breaker when it is removed from the cell. 1 DSII-850 is available in Power modules only. Refer to.

Page 4 Effective: October 1999 Table 3: Substructures for DSII Each substructure includes the stationary primary disconnecting contacts, secondary contact mounting pan, alignment bracket, ground contact, set of rails for drawout mechanism, push to trip mechanism (Style #2A89058G02 push to trip kit from Table 5 is needed for door) for tripping the breaker with the door closed and arc barrier (shipped loose and unmounted). The DSII-840, DSLII-632, DSLII-840, DSII-FT32 and DSII-FT40 also includes a hinged front door. The DSII-FT32 and DSII-FT40 includes a key interlock provision for Type D opposite hand key with zero projection. Breaker Frame Without Rear Bus Extensions With Rear Bus Extensions Style # List Style # List DSII-308... 568F044G13... 1,706... 568F044F11... 2,111 DSII-508... 568F046G27... 1,785... 568F046G26... 2,205 DSII-608... 568F046G29... 1,864... 568F046G28... 2,310 DSII-516... 568F046G24... 1,916... 568F046G21... 2,368 DSII-616... 568F046G25... 2,006... 568F046G23... 2,489 DSII-620... 568F046G25... 2,006... 568F046G23... 2,489 DSII-632... 568F123G12... 3,581... 568F123G11... 3,785 DSII-840... Not Available... N/A... 568F126G04... 6,237 DSII-850... Not Available... N/A... Not Available... N/A DSLII-308...568F045G13... 1,822... 568F045G11... 2,247 DSLII-516...568F047G13... 2,189... 568F047G11... 2,714 DSLII-620...6733D03G14... 2,788... 6733D03G13... 3,470 DSLII-632...Not Available... N/A... 567F960G021➁... 5,056 DSLII-840...Not Available... N/A... 568F126G041➁... 6,237 DSLII-FT32...Not Available... N/A... 568F200G11➁... 4,195 DSLII-FT40...Not Available... N/A... 568F211G05➁... 5,156 Table 4: Erector Set Parts for DSII Description Breaker Style # Min List Qty Each THE FOLLOWING PARTS ARE USED WITH 1, 2, AND 3-PIECE MOLDED STAB SUPPORTS Breaker Mounting Pan... DSII-308... 9247C71G02... 609 Breaker Mounting Pan... DSII-508... 9247C71G04... 646 Breaker Mounting Pan... DSII-608... 9247C71G06... 677 Breaker Mounting Pan... DSII-516... 9247C71G03... 683 Breaker Mounting Pan... DSII-616, DSII-620... 9247C71G05... 730 Breaker Mounting Pan... DSII-632... 8650C01G01... 971 Breaker Mounting Pan Kit➃... DSII-840... 568F126G06... 1,255 Breaker Mounting Pan Kit➃... DSII-FT40... 568F211G07... 1,160 Breaker Mounting Pan... DSII-850... ➂... ➂ Breaker Mounting Pan... DSLII-308... 9247C72G02... 651 Breaker Mounting Pan... DSLII-516... 9247C72G03... 735 Breaker Mounting Pan... DSLII-620... 9246C77G01... 756 Breaker Mounting Pan... DSLII-632... 8650C01G02... 971 Breaker Mounting Pan... DSII-FT32... 8650C02G01... 998 Secondary Contact Mounting Pan... DSII-308, DSLII-308... 8649C21H01... 12... 100 Secondary Contact Mounting Pan... DSII-508, DSII-608... 8649C21H01... 12... 100 Secondary Contact Mounting Pan... DSII-516, DSII-616, DSLII-516... 8649C21H01... 12... 100 Secondary Contact Mounting Pan... DSII-620, DSLII-620... 8649C21H01... 12... 100 Secondary Contact Mounting Pan... DSII-632, DSII-FT32... 8649C21H01... 12... 100 Secondary Contact Mounting Pan... DSII-840, DSII-FT40... 2A89533G02... 3... 100 Secondary Contact Mounting Pan... DSII-850... ➂... ➂ Cell Switch Kit (3 Pole)... ALL... 2A89010G12... 394 Cell Switch Kit (6 Pole)... ALL... 2A89010G13... 436 Cell Secondary Contact Block Kit... ALL... 2A89641G01... 12... 121 1 ➁ Fuse Truck is not included. Price and order this as a separate item. Requires a key interlock on the fuse truck and the breaker to prevent the fuse truck from being withdrawn when the breaker is closed. Requires a shunt trip on the breaker and requires secondary contacts in the fuse truck and the breaker in order to indicate and operate blown limiter protection. ➂ ➃ DSII-850 is available in Power Modules only. Refer to. Includes left and right rail, bottom pan and push to trip mechanism (on DSII-840).

Effective: October 1999 Page 5 Table 4: Erector Set Parts for DSII, Continued Description Breaker Style # Min List Qty Each THE FOLLOWING PARTS ARE USED WITH 1, 2, AND 3-PIECE MOLDED STAB SUPPORTS Communications and Zone Interlock Port... ALL... 2A89650G03... 12... 84 Gas Shield, Horizontal... ALL Except DSII-840, DSII-850... 3583A90H01... 12... 21 Gas Shield, Horizontal... DSII-840, DSII-850... 6469C96H01... 3... 32 Gas Shield, Vertical... DSII-308, DSII-508, DSII-608... 8294A65H01... 24... 21 Gas Shield, Vertical... DSII-516, DSII-616, DSII-620... 8294A65H01... 24... 21 Gas Shield, Vertical... DSLII-308, DSLII-516... 8294A65H01... 24... 21 Gas Shield, Vertical... DSII-632, DSLII-620... 8294A66H01... 6... 26 Gas Shield, Vertical... DSII-840, DSII-850➁... 8294A67H01... 6... 32 Arc Shield (Not Used on Fuse Trucks)... ALL Except DSII-840... 690C950H01... 12... 68 Arc Shield (Not Used on Fuse Trucks)... DSII-840, DSII-850➁... 795A386G02... 3... 89 Push to Trip Kit➂... ALL... 2A89058G02... 3... 42 Cable Interlock Kit for One-High Cell and Erector Sets➀... DSII-308, DSLII-308... 568F201G01... 861 Cable Interlock Kit for One-High Cell and Erector Sets➀... DSII-508, DSII-608, DSII-620... 568F201G01... 861 Cable Interlock Kit for One-High Cell and Erector Sets➀... DSII-516, DSII-616, DSLII-516... 568F201G01... 861 Cable Interlock Kit for One-High Cell and Erector Sets➀... ALL OTHER... Not Available➁...N/A Cable Interlock Kit For Substructures➀... DSII-308, DSLII-308... 437B248G01... 782 Cable Interlock Kit For Substructures➀... DSII-508, DSII-608,DSII-620... 437B248G01... 782 Cable Interlock Kit for Substructures➀... DSII-516, DSII-616, DSLII-516... 437B248G01... 782 Cable Interlock Kit for Substructures➀... ALL OTHER... Not Available➁...N/A Key Interlock Provision for One-High Cell (Locks Breaker Out)➃... DSII-308, DSLII-308... 449D480G11... 467 Key Interlock Provision for One-High Cell (Locks Breaker Out)➃... DSII-508, DSII-608, DSII-620... 449D480G11... 467 Key Interlock Provision for One-High Cell (Locks Breaker Out)➃... DSII-516, DSII-616, DSLII-516... 449D480G11... 467 Key Interlock Provision for One-High Cell (Locks Breaker Out)➃... DSII-632... 449D480G12... 494 Key Interlock Provision for One-High Cell (Locks Breaker Out)➃... DSII-840... 449D480G13... 504 Key Interlock Provision for One-High Cell (Locks Breaker Out)➃... DSII-850... ➁... ➁ Key Interlock Provision for Substructures (Locks Breaker Out)➃.. DSII-308, DSLII-308... 449D480G17... 478 Key Interlock Provision for Substructures (Locks Breaker Out)➃.. DSII-508, DSII-608... 449D480G17... 478 Key Interlock Provision for Substructures (Locks Breaker Out)➃.. DSII-516, DSII-616, DSLII-516... 449D480G17... 478 Key Interlock Provision for Substructures (Locks Breaker Out)➃.. DSII-620... 449D480G17... 478 Key Interlock Provision for Substructures (Locks Breaker Out)➃.. DSII-632... 449D480G18... 551 Key Interlock Provision for Substructures (Locks Breaker Out)➃.. ALL OTHER... Not Available➁...N/A Key Interlock Provision for Erector Sets (Locks Breaker Out)➃... DSII-308, DSLII-308... 449D480G19... 478 Key Interlock Provision for Erector Sets (Locks Breaker Out)➃... DSII-508, DSII-608... 449D480G19... 478 Key Interlock Provision for Erector Sets (Locks Breaker Out)➃... DSII-516, DSII-616, DSLII-516... 449D480G19... 478 Key Interlock Provision for Erector Sets (Locks Breaker Out)➃... DSII-620... 449D480G19... 478 Key Interlock Provision for Erector Sets (Locks Breaker Out)➃... DSII-632... 449D480G20... 551 Key Interlock Provision for Erector Sets (Locks Breaker Out)➃... DSII-840... 449D480G20... 551 Key Interlock Provision for Erector Sets (Locks Breaker Out)➃... ALL OTHER... Not Available➁...N/A Key Interlock Provision (Trip Free)➄... DSII-308, DSLII-308... 9119D85G01... 121 Key Interlock Provision (Trip Free)➄... DSII-508, DSII-608, DSII-620... 9119D85G01... 121 Key Interlock Provision (Trip Free)➄... DSII-516, DSII-616, DSLII-516... 9119D85G01... 121 Key Interlock Provision (Trip Free)➄... DSII-632... 9119D85G02... 142 Key Interlock Provision (Trip Free)➄... ALL OTHER... Not Available...N/A Test Cabinet (120 Vac/125 Vdc)... ALL... 6500C57G03... 2,541 Test Cabinet (240 Vac/250 Vdc)... ALL... 6500C57G04... 2,541 1 For interlocking 2 adjacent breakers in the same structure. ➁ DSII-850 is avialable in Power Modules only. Refer to. ➂ Style number is for 10 kits in one box. Each kit includes one push-to-trip plate, one pushto-trip label, one hinge bracket and two rivets. ➃ For Type F zero projection key. ➄ For Type F opposite hand zero projection key.

Page 6 Effective: October 1999 Table 4: Erector Set Parts for DSII, Continued Description Breaker Style # Min List Qty Each THE FOLLOWING PARTS ARE USED WITH 1, 2, AND 3-PIECE MOLDED STAB SUPPORTS Portable Lift Truck (Floor Running)... ALL... 6727D63H20... 4,998 Lifting Yoke for Portable Lift Truck... ALL... 694C614G02... 215 Breaker Lifter Assembly (Top Rail Mounted)... ALL... 694C616G01... 4,326 Lifter Rail Guide Assembly for 12" Wide Structure... ALL... 694C616G05... 5... 42 Lifter Rail Guide Assembly for 21" Wide Structure... ALL... 694C616G02... 5... 68 Lifter Rail Guide Assembly for 30" Wide Structure... ALL... 694C616G14... 5... 100 Lifter Rail Guide Assembly for 34" Wide Structure... ALL... 694C616G03... 5... 105 Rail Stop... ALL... 694C616G04... 10... 21 Digitrip/Amptector Test Kit... ALL... 8779C02G02... 8,689 Digitrip/Amptector Test Kit Adapter... ALL... 8779C02G01... 704 Breaker Levering Tool... ALL... 8644C73G01... 168 Breaker Levering Tool with Storage Bracket... ALL... 8644C73G02... 184 Insulating Boots... Through 2000 Amp... 140D294H02... 30... 37 Insulating Boots... 3200 Amp Phase A & C... 140D768H01... 6... 68 Insulating Boots... 3200 Amp Phase B... 140D769H01... 3... 100 Insulating Boots... All Other... Not Available... N/A THE FOLLOWING PARTS ARE USED WITH 1-PIECE MOLDED STAB SUPPORTS Molded Stab Support (1-Piece) (1 required)... DSII-308, DSLII-308... 449D395G01... 152 Molded Stab Support (1-Piece) (1 required)... DSII-508, DSII-608, DSII-620... 449D395G01... 152 Molded Stab Support (1-Piece) (1 required)... DSII-516, DSII-616, DSLII-516... 449D395G01... 152 Molded Stab Support (1-Piece) (1 required)... DSII-632, DSII-FT32, DSLII-620... 567F384G01... 194 Riser Bus Stabs for 1-Piece Molded Stab Supports... DSII-308, DSLII-308... 5501A17G01... 152 Riser Bus Stabs for 1-Piece Molded Stab Supports... DSII-508, DSII-608, DSII-620... 750A035G02... 184 Riser Bus Stabs for 1-Piece Molded Stab Supports... DSII-516, DSII-616, DSLII-516... 750A035G02... 184 Riser Bus Stabs for 1-Piece Molded Stab Supports... DSII-632, DSII-FT32, DSLII-620... 750A040H01... 226 Load Runback... DSII-308, DSLII-308... 8644C77G01... 257 Load Runback... DSII-508, DSII-608, DSII-620... 8644C76G06... 389 Load Runback... DSII-516, DSII-616, DSLII-516... 8644C76G06... 389 Load Runback... DSII-632, DSII-FT32, DSLII-620... 8644C76G02... 893 Runback Support... DSII-308, DSLII-308... 449D465H01... 105 Runback Support... DSII-508, DSII-608, DSII-620... 449D465H01... 105 Runback Support... DSII-516, DSII-616, DSLII-516... 449D465H01... 105 Runback Support... DSII-632, DSII-FT32, DSLII-620... 449D371H01... 173 Riser Bus Supports... ALL Except DSII-840, DSII-FT40.. 591C357G01... 20... 53 Shutter for 1-Piece Molded Stab Support... DSII-308, DSII-508, DSII-608... 6435C06G01... 557 Shutter for 1-Piece Molded Stab Support... DSII-516, DSII-616, DSII-620... 6435C06G01... 557 Shutter for 1-Piece Molded Stab Support... DSLII-620... 3A76647G01... 557 Shutter for 1-Piece Molded Stab Support... DSII-632... 6435C10G01... 620 Shutter for 1-Piece Molded Stab Support... DSLII-308, DSLII-516... 6435C06G02... 557 Shutter for 1-Piece Molded Stab Support... DSII-FT32... 6501C45G01... 809

Effective: October 1999 Page 7 Table 4: Erector Set Parts for DSII, Continued Description Breaker Style # Min List Qty Each THE FOLLOWING PARTS ARE USED WITH 2-PIECE MOLDED STAB SUPPORTS Molded Stab Support (2-Piece) (2 required)... DSII-308, DSLII-308... 567F908G01... 2... 100 Molded Stab Support (2-Piece) (2 required)... DSII-508, DSII-608... 567F908G01... 2... 100 Molded Stab Support (2-Piece) (2 required)... DSII-516, DSII-616, DSLII-516... 567F908G01... 2... 100 Molded Stab Support (2-Piece) (2 required)... DSII-620... 567F908G01... 2... 100 Molded Stab Support (2-Piece) (2 required)... DSII-632, DSII-FT32, DSLII-620... 567F910G01... 2... 126 Cell Stabs for 2-Piece Molded Stab Supports... DSII-308, DSLII-308... 435B632H01... 158 Cell Stabs for 2-Piece Molded Stab Supports... DSII-508, DSII-608... 809A476H01... 158 Cell Stabs for 2-Piece Molded Stab Supports... DSII-516, DSII-616, DSLII-516... 809A476H01... 158 Cell Stabs for 2-Piece Molded Stab Supports... DSII-620... 809A476H01... 158 Cell Stabs for 2-Piece Molded Stab Supports... DSII-632, DSII-FT32, DSLII-620... 809A482H01... 231 Bus Spacer Plate for Use With 2-Piece Molded Stab Support... DSII-308, DSLII-308... 809A493H03... 72... 26 Bus Spacer Plate for Use With 2-Piece Molded Stab Support... DSII-508, DSII-608... 809A493H03... 72... 26 Bus Spacer Plate for Use With 2-Piece Molded Stab Support... DSII-516, DSII-616, DSLII-516... 809A493H03... 72... 26 Bus Spacer Plate for Use With 2-Piece Molded Stab Support... DSII-620... 809A493H03... 72... 26 Bus Spacer Plate for Use With 2-Piece Molded Stab Support... DSII-632, DSII-FT32, DSLII-620... 3582A07H01... 36... 37 Rear Bus Extension➀... DSII-308, DSLII-308... 436B057H01... 144... 37 Rear Bus Extension➀... DSII-508, DSII-608... 436B056H01... 144... 42 Rear Bus Extension➀... DSII-516, DSII-616, DSLII-516... 436B056H01... 144... 42 Rear Bux Extension➀... DSII-620... 436B056H01... 144... 42 Rear Bux Extension➀... DSII-632, DSII-FT32, DSLII-620... 588C948H01... 72... 84 Rear Bus Extension Insulator for 2-Piece Molded Stab Support... ALL except DSII-840, 850... 588C944H01... 12... 26 Rear Bus Extension Insulator Mounting Bracket... ALL except DSII-840, 850... 19D8888H02... 24... 21 Shutter for 2-Piece Molded Stab Support and Substructures... DSII-308, DSII-508, DSII-608... 6435C11G01... 557 Shutter for 2-Piece Molded Stab Support and Substructures... DSII-516, DSII-616... 6435C11G01... 557 Shutter for 2-Piece Molded Stab Support and Substructures... DSII-620... 6435C11G01... 557 Shutter for 2-Piece Molded Stab Support and Substructures... DSLII-620... 3A76647G01... 557 Shutter for 2-Piece Molded Stab Support and Substructures... DSII-632... 6435C10G01... 620 Shutter for 2-Piece Molded Stab Support and Substructures... DSII-FT32... 6501C45G01... 814 Shutter for 2-Piece Molded Stab Support and Substructures... DSII-308, DSLII-516... 6435C11G02... 641 THE FOLLOWING PARTS ARE USED WITH 3-PIECE MOLDED STAB SUPPORTS Molded Stab Support (3-Piece) (3 Required)... DSII-840, DSII-FT40... 436B112H01... 3... 152 Cell Stabs for 3-Piece Molded Stab Supports... DSII-840, DSII-FT40... 114B453H01... 389 Cell Stab (Riser Bus) Support Bracket... DSII-840, DSII-FT40... 114C738H01... 18... 21 Load Runback... DSII-840, DSII-FT40... 114C764G01... 919 Runback Support... DSII-840, DSII-FT40... 1944C01H01... 378 Shutter for 3-Piece Molded Stab Support and One-High... DSII-840, DSII-FT40... 6435C17G01... 950 Copyright Inc., 1999. All Rights Reserved. 1 Requires Rear Bus Extension Insulator S#588C944H01

Page 8 Effective: October 1999 PL44B04APE Printed in U.S.A.