Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Similar documents
Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Application Mini Contactors for Motors and Resistive Loads

Application Mini Contactors for Motors and Resistive Loads

Deliveryprogramme. Overloadrelay,6-9A,1N/O+1N/C. Articleno CatalogNo. XTOM009AC1. Settingrange. Auxiliarycontacts. Short-circuitprotection

Deliveryprogramme. Overloadrelay,24-40A,1N/O+1N/C. Articleno CatalogNo. XTOB040DC1. Auxiliarycontacts. Short-circuitprotection

Contactelement,1N/C,frontmount,6.contact,screwconnection. Product range RMQ-Titan (drilling dimensions 22.5 mm)

Motor-protectivecircuit-breaker,3p,Ir=2.5-4A. Product range PKZM01 motor protective circuit-breakers up to 16 A with pushbutton actuation

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.

DATASHEET - ZB Delivery program. Overload relay, 50-65A, 1N/O+1N/C. Catalog No Eaton Catalog No. XTOB065DC1 EL-Nummer

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC mm

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking

Product range Overload relay ZB up to 150 A. Phase-failure sensitivity IEC/EN 60947, VDE 0660 Part 102

Miniaturecircuitbreaker(MCB),6A,1Np,C-Char,AC. Application Switchgear for industrial and advanced commercial applications.

Overloadrelay,10-16A,1N/O+1N/C. Articleno

Approvals UL 508; CSA-C22.2 No ; CSA-C22.2 No. 94; IEC/EN ; CE marking

Product range RMQ-Titan (drilling dimensions 22.5 mm) Description Cage Clamp is a registered trademark of Wago Kontakttechnik GmbH/ Minden, Germany

Approvals UL 508; CSA-C22.2 No ; IEC/EN ; CE marking

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Emergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0

Product range RMQ-Titan (drilling dimensions 22.5 mm) Description Cage Clamp is a registered trademark of Wago Kontakttechnik GmbH/ Minden, Germany

Industrial Switchgear New Products Catalogue Pole Switching with the DILMP Contactors

CA Z-EN Overload relays, CT-operated overload relays

Subrange SmartWire-DT electronic motor starters. Basic function Reversing starters (complete devices)

TAE pole Contactors

AF40... AF96 3-pole contactors Technical data

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

PKZ and PKE motor-protective circuit-breakers

06/001. Overload Relays, Motor-Protective Relays Overview. Overload / Motor-Protective Relays. Moeller HPL /2002

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

Contactors. 1.1 E Line contactors. 1.2 xstart series contactors. 1.3 xstart C series contactors. 1.4 D Line contactors.

IEC CONTACTORS AND OVERLOAD RELAYS

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

Electronic overload relay EF65, EF96 and EF146

Contactors. 1.1 E Line contactors Control relays XTRG... 1 Contactors XTCG... 4

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated

Bulletin 193-T1 Bimetallic Overload Relays

AE 9... AE 40 Contactors NE... Contactor Relays

Contactors KNL A 68 KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30. Dimensional drawing of KNL KNL6, KNL9, KNL12, KNL16, KNL18 KNL22, KNL30

Approved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1

1.1. Safety Products. Contents. LS-Titan Safety Interlock Switches. LS-Titan Safety Interlock Switches

ASL09..S 3-pole Contactors - Spring Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

Installation Contactors RIC, RAC

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

Industrial Contactors CTX 3 3P 185A - 800A

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals

Description. Positive safety relays

Flexible. Intelligent. Trendsetting.

Micro Contactor MA Series

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

B Mini Contactor V Hz

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated

Thermal Overload Relays

Thermal overload relay TF65 and TF96

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

Solid State Relays, 3-phase

DIN EN UL 508 / CSA 3RF A A 0 2

Protection Equipment

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

Electrical sector solutions E Line family. Industry leading design in a compact package

Thermal overload relay TF140DU and TF140DU-V1000

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals

AF series contactors (9 2650)

Electrical sector solutions E Line family. Industry leading design in a compact package

Mini contactors, relays, contactors

Electronic overload relays EF205 and EF370

Scheda prodotto Relè Series B

BC Mini Contactor VDC

Technical Information

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

4 - Miniature controls

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

Auxiliary contact blocks - with spring terminals Accessories

AF series contactors (9 2650)

CI-TI Contactors and motor starters Types CI 61 - CI 98

UL/CSA Non-fused Disconnect Switches

249.1 m3/h m3/h 7.23 MW m3/h 50.0 m3/h

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

Switches Unlimited Phone: * Fax:

MS25, MST25, MS20, MST20

MS General Information Extended Product Type: MS

Add-on blocks and accessories For BG series mini-contactors For BF series contactors For B series contactors...

Siemens AG Price groups PG 14O, 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J

Cat. No. 194R-J Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.

TeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30

Transcription:

Deliveryprogramme Contactorrelay,3N/O+1N/C,DCcurrent Partno. DILER-31-G-C(110VDC) Articleno. 231831 CatalogNo. XTRMC10A31E0 Product range DILER Mini-contactors Application Contactor relays Description with interlocked opposing contacts Connection technique Spring-loaded terminals Ratedoperationalcurrent Conventional free air thermal current, 3 pole, 50-60 Hz AC-15 Open Contacts at 50 C I th =I e A 10 220 V 230 V 240 V I e A 6 380 V 400 V 415 V I e A 3 N/O = Normally open 3 N/O N/C = Normally closed 1 NC Contact sequence Codenumberandversionofcombination Distinctive number 31E For use with DILE-C Actuating voltage 110 V DC Voltage AC/DC DC operation Instructions Contact numbers to EN 50011 Coil terminal markings to EN 50005 Integrated diode-resistor combination Coil rating 2.6 W Technicaldata General Standards IEC/EN 60947, VDE 0660, UL, CSA Lifespan, mechanical DC operated Operations x 10 6 20 Maximum operating frequency Operations/h 9000 Climatic proofing Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 Ambient temperature C Open C -25 - +50 Enclosed C - 25-40 Mounting position Mounting position As required, except vertical with terminals A1/A2 at the bottom 10/06/2015 231831 - HPL-ED2015 V15.0 EN 1 / 7

Mounting position Mechanical shock resistance (IEC/EN 60068-2-27) Half-sinusoidal shock, 10 ms Basic unit with auxiliary contact module g N/O contact g 10 N/C contact g 8 Degree of Protection IP20 Protection against direct contact when actuated from front (EN 50274) Finger and back-of-hand proof Weight DC operated kg 0.2 Terminal capacities mm 2 Spring-loaded terminals Solid 2 mm 1 x (1-2.5) 2 x (1-2.5) Flexible with or without ferrule DIN 46228 2 mm 1 x (1-2.5) 2 x (1-2.5) Solid or stranded AWG 1 x (16-14) 2 x (16-14) Standard screwdriver mm 0.6 x 3.5 Contacts Positive operating contacts to EN 60947-5-1 appendix L, including auxiliary contact module Rated impulse withstand voltage U imp V AC 6000 Overvoltage category/pollution degree III/3 Rated insulation voltage U i V AC 690 Rated operational voltage U e V AC 600 Safe isolation to EN 61140 between coil and auxiliary contacts V AC 300 between the auxiliary contacts V AC 300 Rated operational current A Conventional free air thermal current, 3 pole, 50-60 Hz AC-15 Open at 50 C I th =I e A 10 220 V 230 V 240 V I e A 6 380 V 400 V 415 V I e A 3 500 V I e A 1.5 DC current Notes Switch-on and switch-off conditions based on DC-13, time constant as specified. DC-13 L/R - 15 ms Contacts in series: A 1 24 V A 2.5 2 60 V A 2.5 3 110 V A 1.5 3 220 V A 0.5 Control circuit reliability Failure rate λ <10-8, < one failure at 100 million operations (at U e = 24 V DC, U min = 17 V, I min = 5.4 ma) Short-circuit rating without welding Yes 10/06/2015 231831 - HPL-ED2015 V15.0 EN 2 / 7

Maximum overcurrent protective device 220 V 230 V 240 V PKZM0 4 380 V 400 V 415 V PKZM0 4 Short-circuit protection maximum fuse 500 V A gg/gl 6 500 V A fast 10 Current heat loss at I th DC operated W 0.3 Magnetsystems Voltage tolerance DC operated Notes Smoothed DC, three-phase bridge rectifiers or smoothed double-wave rectification Pick-up voltage 0.85 1.3 at 24 V: without auxiliary contact component (40 C) Pick-up x U c 0.7-1.3 Power consumption DC operation Power consumption Pick-up = Sealing VA/W 2.6 duty factor % DF 100 Switching times at 100 % U c (approximate values) DC operated closing delay ms 26-35 DC operated N/O contact opening delay ms 15-25 DC operated With auxiliary contact module Max. closing delay ms 70 DesignverificationasperIEC/EN61439 Technical data for design verification Rated operational current for specified heat dissipation I n A 6 Heat dissipation per pole, current-dependent P vid W 0.4 Equipment heat dissipation, current-dependent P vid W 0 Static heat dissipation, non-current-dependent P vs W 2.3 Heat dissipation capacity P diss W 0 Operating ambient temperature min. C -25 Operating ambient temperature max. C 50 IEC/EN 61439 design verification 10.2 Strength of materials and parts 10.2.2 Corrosion resistance Meets the product standard's requirements. 10.2.3.1 Verification of thermal stability of enclosures Meets the product standard's requirements. 10.2.3.2 Verification of resistance of insulating materials to normal heat Meets the product standard's requirements. 10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects Meets the product standard's requirements. 10.2.4 Resistance to ultra-violet (UV) radiation Meets the product standard's requirements. 10.2.5 Lifting Does not apply, since the entire switchgear needs to be evaluated. 10.2.6 Mechanical impact Does not apply, since the entire switchgear needs to be evaluated. 10.2.7 Inscriptions Meets the product standard's requirements. 10.3 Degree of protection of ASSEMBLIES Does not apply, since the entire switchgear needs to be evaluated. 10.4 Clearances and creepage distances Meets the product standard's requirements. 10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated. 10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated. 10.7 Internal electrical circuits and connections Is the panel builder's responsibility. 10.8 Connections for external conductors Is the panel builder's responsibility. 10.9 Insulation properties 10.9.2 Power-frequency electric strength Is the panel builder's responsibility. 10.9.3 Impulse withstand voltage Is the panel builder's responsibility. 10.9.4 Testing of enclosures made of insulating material Is the panel builder's responsibility. 10.10 Temperature rise The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. 10/06/2015 231831 - HPL-ED2015 V15.0 EN 3 / 7

10.11 Short-circuit rating Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.12 Electromagnetic compatibility Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.13 Mechanical function The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. TechnicaldataETIM6.0 Low-voltage industrial components (EG000017) / Contactor relay (EC000196) Electric engineering, automation, process control engineering / Low-voltage switch technology / Contactor (LV) / Contactor relay (ecl@ss8.1-27-37-10-01 [AAB716011]) Rated control supply voltage Us at AC 50HZ V 0-0 Rated control supply voltage Us at AC 60HZ V 0-0 Rated control supply voltage Us at DC V 110-110 Voltage type for actuating DC Rated operation current Ie, 400 V A 3 Connection type auxiliary circuit Federzuganschluss Mounting method DIN-Schiene/Schraube Interface Nein Number of auxiliary contacts as normally closed contact 1 Number of auxiliary contacts as normally open contact 3 Number of auxiliary contacts as normally closed contact, delayed switching 0 Number of auxiliary contacts as normally open contact, leading 0 With LED indication Nein Number of auxiliary contacts as change-over contact 0 Manual operation possible Nein Approvals Product Standards IEC/EN 60947-4-1; UL 508; CSA-C22.2 No. 14-05; CE marking UL File No. E29184 UL Category Control No. NKCR CSA File No. 012528 CSA Class No. 3211-03 North America Certification UL listed, CSA certified Specially designed for North America No 10/06/2015 231831 - HPL-ED2015 V15.0 EN 4 / 7

Characteristics 1: Suppressor 2: Auxiliary contact module 10/06/2015 231831 - HPL-ED2015 V15.0 EN 5 / 7

Component lifespan (operations) Ie = Rated operational current Dimensions DILER- DILER- -G(-C) 10/06/2015 231831 - HPL-ED2015 V15.0 EN 6 / 7

DILER- (-C) + DILE(-C) DILER- -G(-C) + DILE(-C) Additionalproductinformation(links) IL03407009Z(AWA2100-0882)Minicontactorrelay IL03407009Z (AWA2100-0882) Mini contactor relay UL/CSA: Approved rating data ftp://ftp.moeller.net/documentation/awa_instructions/il03407009z2010_10.pdf http://de.ecat.moeller.net/flip-cat/?edition=hplte&startpage=5.84 10/06/2015 Eaton Industries GmbH http://www.eaton.eu 09/2015 by Eaton Industries GmbH 231831 - HPL-ED2015 V15.0 EN 7 / 7