SECTION 08316 WTERTIGHT IRTIGHT SPECIL CCESS DOORS & HTCHES, PRT 1 GENERL HIGHLIGHTED RES TO BE INSERTED BY SPECIFYING ENGINEER. 1.1 WORK OF THIS SECTION. THE WORK OF THIS SECTION INCLUDES PROVIDING LL LBOR MTERILS, TOOLS, EQUIPMENT ND LL PPURTENNT WORK NECESSRY TO FURNISH DELIVER & INSTLL SPECIL DOORS S OUTLINED IN THE CONTRCT DRWINGS. B. TYPES OF SPECIL DOORS REQUIRED SHLL INCLUDE WTERTIGHT CLOSURES S IDENTIFIED IN THE PROJECT SPECIFICTIONS ND PROJECT DRWINGS. C. SIZE & LOCTION OF SPECIL DOORS SHLL CONSIST OF (INSERT PROPER RES) S INDICTED BY THE CONTRCT DRWINGS. 1.2 RELTED SECTIONS THE WORK OF THE FOLLOWING SECTIONS PPLIES TO THE WORK OF THIS SECTION. OTHER SECTIONS OF THE SPECIFICTIONS, NOT REFERENCED BELOW, SHLL LSO PPLY TO THE EXTENT REQUIRED FOR PROPER PERFORMNCE OF THIS WORK 1. SECTION (INSERT PROPER SECTION #) 1.3 CODES CST-LN-PLCE CONCRETE DOPTED BY (INSERT PROPER JURISDICTION) THE WORK OF THIS SECTION SHLL COMPLY WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES S 1. UNIFORM BUILDING CODE 1.4 SHOP DRWINGS ND SMPLES. THE FOLLOWING SHLL BE SUBMITTED IN COMPLINCE WITH SECTION (INSERT PROPER SECTION) 1. PRODUCT DT: CONTRCTOR SHLL SUBMIT MNUFCTURER'S PRODUCT SPECIFICTIONS, STNDRD DETILS, CERTIFIED PRODUCT TEST RESULTS, INSTLLTION INSTRUCTIONS ND GENERL THE RECOMMENDTIONS, S -PPLICBLE TO MTERILS ND FINISHES FOR ECH COMPONENT ND FOR TOTL SYSTEM 2. SMPLES: CONTRCTOR SHLL SUBMIT THE FOLLOWING SMPLES ND CCOMPNYING DESCRIPTIVE DT: specifications watertight closures 11-2008last saved Wednesday, November 25, 2009 Page 1 of 6
. FSTENERS: TWO OF ECH TYPE TO BE USED, WITH STTEMENT REGRDING INTENDED USE. B. CLOSURES: GSKET SEL. 2. SHOP DRWINGS: CONTRCTOR SHLL SUBMIT SMLL SCLE LYOUTS OF DOORS ND LRGE SCLE details of edge conditions, joints, comers, custom profiles, support, anchorage, trim sections, closures and special details. Distinction shall be made between factory & field assembly work. 4. ENGINEERING DT: DESIGN CLCULTIONS, CERTIFIED BY STRUCTURL ENGINEER LICENSED THT THE PROPOSED SPECIL DOORS WILL MEET THE SPECIFIED DESIGN CRITERI. 1. 5 EXPERIENCE & QULIFICTIONS. MNUFCTURER'S QULIFICTIONS: THE MNUFCTURER SHLL HVE HD T LEST FIVE YERS EXPERIENCE IN PRODUCING THE SPECIFIC SPECIL DOORS INDICTED. 1.6 QULITY SSURNCE. THE MNUFCTURER SHLL OBSERVE ND PPROVE THE INSTLLTION OF THE SPECIL DOORS. PRT 2 - PRODUCTS 2.1 GENERL. PERFORMNCE TEST STNDRDS: CONTRCTOR SHLL PROVIDE SPECIL DOORS HVE BEEN PRE TESTED ND CERTIFIED BY THE MNUFCTURER TO PROVIDE THE INDICTED RESISTNCE TO IR ND WTER INFILTRTION ND STRUCTURL DEFLECTION ND FILURE WHEN INSTLLED S INDICTED ND WHEN TESTED IN CCORDNCE WITH TEST PROCEDURES DESCRIBED HEREIN. B. THE SPECIL DOORS SHLL BE MODEL (PLESE SELECT & INSERT PROPER MODEL #) MODEL # DESCRIPTION OPERTION GSKET TYPE MTERIL WTD2004-I2 H-LM WTD2004-DC H-LM WTD2004-DC H- STL WTD2004-DC - H- SS WTD2004-I2- Q H-LM WTD2004-DC- Q H-LM WTD2004-DC- Q H- STL (VERTICL PLIN) (VERTICL PLIN) (VERTICL PLIN) (VERTICL PLIN) (VERTICL PLIN) QUICK CTING WHEEL / LEVER OPERTED (VERTICL PLIN) QUICK CTING WHEEL / LEVER OPERTED (VERTICL PLIN) QUICK CTING WHEEL / MNUL SWING DUL INFLTBLE LUMINUM MNUL SWING MNUL SWING MNUL SWING LUMINUM STINLESS MNUL SWING DUL INFLTBLE LUMINUM MNUL SWING MNUL SWING MULTIPLE COMPRESSION MULTIPLE COMPRESSION LUMINUM specifications watertight closures 11-2008last saved Wednesday, November 25, 2009 Page 2 of 6
WTD2004- DC-Q -H- SS -RH-LM -RH- STL -RH- SS -FH-LM -FH- STL -FH-SS WT2004-DC- SLD - LM WT2004-DC SLD STL WT2004-DC SLD - SS WT2004-I2 SLD - LM LEVER OPERTED (VERTICL PLIN) QUICK CTING WHEEL / LEVER OPERTED HINGED HTCH (HORIZONTL RISED PLIN) HINGED HTCH (HORIZONTL RISED PLIN) HINGED HTCH (HORIZONTL RISED PLIN) HINGED HTCH (HORIZONTL FLUSH PLIN) HINGED HTCH (HORIZONTL FLUSH PLIN) HINGED HTCH (HORIZONTL FLUSH PLIN) MNUL SWING MULTIPLE COMPRESSION MNUL SWING MNUL SWING MNUL SWING MNUL SWING MNUL SWING MNUL SWING SLIDE DOOR SLIDE IN TRCK SLIDE DOOR SLIDE IN TRCK SLIDE DOOR SLIDE IN TRCK STINLESS LUMINUM STINLESS LUMINUM STINLESS LUMINUM STINLESS SLIDE DOOR SLIDE IN TRCK DUL INFLTBLE LUMINUM C. DISSIMILR MTERILS SHLL BE SEPRTED FROM ECH OTHER THROUGH THE USE OF PPROVED GSKETS OR COTINGS. 2.2 MTERILS SELECT PPROPRITE MTERIL PNELS ND FRMES STM 36 SHEET PNELS ND FRMES STINLESS STM 240 SHEET SELECT GRDES 304, 304L, 316, 316L PNELS ND FRMES LUMINUM STM B209 SELECT 5052 H32, 5086, 6061 T-6. B. SELECT PPROPRITE MTERIL EXTRUSIONS & SHPES: STM 36 EXTRUSIONS & SHPES: STINLESS STM 276. SELECT GRDES 304, 304L, 316, 316L specifications watertight closures 11-2008last saved Wednesday, November 25, 2009 Page 3 of 6
EXTRUSIONS & SHPES: LUMINUM STM B209 SELECT 6061 T-6. C. FSTENERS: 300 SERIES STINLESS. D. GSKETS: NEOPRENE HYPLON, OR EQUL. E. EXPNSION NCHOR BOLTS: SERIES 300 STINLESS. F. SELECT PPROPRITE MTERIL STIFFENER NGLES: STM 36 STIFFENER NGLES EXTRUSIONS & SHPES: STINLESS STM 276. STIFFENER NGLES EXTRUSIONS & SHPES: LUMINUM STM B209 SELECT GRDES 304, 304L, 316, 316L SELECT 6061 T-6. STRUCTURL NGLES S REQUIRED BY THE MNUFCTURER. 2.3 METL FINISHES SELECT PPROPRITE FINISH. (FOR FLUSH ND WLKED ON SURFCE) INTEGRL NON-SKID FINISH SHLL BE PROVIDED TO LL SURFCES THT MY BE SUBJECT TO FOOT TRFFIC. THE NON-SKID SURFCE SHLL NOT BE CHIEVED BY THE USE OF PINT OR DHESIVE TPES B. (FOR LL PRODUCTS) BRUSH OFF BLST CLEN PER SSPC-SP7. PRIME WITH ONE COT RUST INHIBITIVE, LED FREE PRIMER. PPLY FIELD FINL COT FTER INSTLLTION IN CCORDNCE WITH PINT ND FINISH SCHEDULE SEE SEC (INSERT PPROPRITE SECTION...) C. (FOR STINLESS ND LUMINUM PRODUCTS) BRSIVE CLEN, OR CID WSH T THE OPTION OF THE MNUFCTURER. OR/ BRUSH OFF BLST CLEN PER SSPC-SP7. WITH USE OF SND / GLSS BEDS 2.4 DESIGN CRITERI. THE SPECIL DOORS FRME ND SKIN SHLL BE DESIGNED IN CCORDNCE WITH THE SPECIFICTIONS S PUBLISHED BY THE STM SSOCITION ND DESIGNED FOR FULL DED LOD PLUS LIVE LOD IN CCORDNCE WITH THE UNIFORM BUILDING CODE LTEST EDITION S PPLICBLE FOR THIS LOCTION. SPECIL DOOR DEFLECTION SHLL BE LESS THN OR EQUL TO L/360 UNDER TOTL DED ND LIVE LOD CONDITION. B. WTERTIGHT DOORS SHLL BE DESIGNED WITH MINIMUM 2:1 FCTOR OF SFETY BSED ON MTERIL YIELD STRENGTH. C. STIFFENER NGLES SHLL BE WELDED TO PNEL UNDERSIDE ND CONCELED FROM VIEW. BOLTED OR RIVETED CONSTRUCTION IS NOT CCEPTBLE. D. THE DIRECT TTCHMENT OF PNELS TO THE SURFCE OF FRME MEMBERS BY MENS OFF BOLTS, SCREWS OR SELF DRILLING FSTENERS EXTENDING THROUGH THE PNELS, OTHER TOP FLNGES, OR OUTER EDGES OF THE PNEL WILL NOT BE CCEPTBLE E. SPECIL DOORS SHLL BE HINGED TO SSURE PROPER ND SMOOTH SWING OF THE COVER UP TO 180 DEGREES OR TO THE EXTENT THT HOLD BCK OR RESTRICTIVE MECHNISMS MY PPLY. HINGES SHLL HVE SLOTTED HOLES TO PROTECT THEM FROM SEL PRESSURE LODS. SEL LODS SHLL NOT BE TRNSMITTED TO THE HINGES. HINGE PINS ND WSHERS SHLL BE OF 304 STINLESS, UNLESS OTHERWISE SPECIFIED. F. THE SPECIL DOORS SHLL BE EQUIPPED WITH STINLESS DOGS. (LTCHING DEVICES). THE NUMBER SIZE ND LOCTION WILL BE DICTTED BY THE SPECIL DOOR SIZE S WELL S THE SPECIFIED DESIGN CONDITIONS. DOGS RE SPCED TO TRNSMIT THE SELING LOD EQULLY TO THE SURROUNDING FRME ND GRDE. DOGS SHLL BE FLUSH TO VOID INTERFERENCE WITH PERSONNEL, EQUIPMENT ND VEHICLE TRFFIC. G. SPECIL DOORS SHLL BE DESIGNED TO CONFORM TO THE -FOLLOWING CRITERI FOR WTER specifications watertight closures 11-2008last saved Wednesday, November 25, 2009 Page 4 of 6
PENETRTION ND IR INFILTRTION: 1. WTER PENETRTION: NO LEKGE T XX FT OF WTER HED STNDING WTER. H. THE SPECIL DOORS SHLL HVE COMPRESSION STOPS TO SSURE THT TRFFIC ND WTER PRESSURE WILL NOT DMGE THE GSKET SEL. LL SELS RE OF CONTINUOUS MTERIL S SPECIFIED ND DETERMINED BY THE CONDITIONS. SELS RE SECURELY EMBEDDED IN SEL GROOVE. I. LIFT POCKETS OR HNDLES WITHOUT THE PENETRTION OF HTCH / DOOR COVER SHLL BE PROVIDED WITH ECH PNEL. J. STRP NCHOR DEVICES MY BE FIELD WELDED TO THE FRME IN ORDER TO ENSURE THEY RE PROPERLY EMBEDDED IN CONCRETE. OTHER OPTIONS INCLUDE SURFCE GSKETS, BOLTS ND WEDGE NCHORS. 2.5 INSPECTION & TESTS LL WELDS IN THE POTENTIL "LEK PTH" SHLL BE LIQUID PENETRNT INSPECTED IN CCORDNCE WITH PPENDIX VIII OF SECTION VIII DIV. 1 OF SME CODE. B. FINISHED SSEMBLY, OR SSEMBLY SIMILR IN DESIGN SHLL BE FCTORY LEK TESTED IN CCORDNCE WITH STM E283. 2.6 MNUFCTURERS. PRODUCTS OF THE TYPE INDICTED SHLL BE PROVIDED BY THE FOLLOWING MNUFCTURERS: 1. VR CONTINMENT 176-25 UNION TURNPIKE SUITE 175 FRESH MEDOWS NY 11366 TEL (516) 673 4961 FX (866) 286 5616 E-MIL: VR_CONTINMENT@YMIL.COM / WEB SITE WWW.VRCONTINMENT.COM 2. OR PRE PPROVED EQUL. 3.1 INSTLLTION. GENERL: CONTRCTOR SHLL COMPLY WITH SPECIL DOOR MNUFCTURER'S INSTRUCTIONS ND RECOMMENDTIONS FOR INSTLLTION, S PPLICBLE TO PROJECT CONDITIONS ND SUPPORTING SUBSTRTES. MNUFCTURER'S BE PRESENT TO SUPERVISE, INSPECT ND SSIST IN THE INSTLLTION T THE STRT UP STGE ND "ON N S NEEDED BSIS" THEREFTER S DETERMINED BY THE ENGINEER. 1. EXCESS SCRP SHLL BE REMOVED ND WORKING SURFCES SHLL BE KEPT FROM DEBRIS ON REGULR DILY BSIS. 2. FILINGS CUSED BY DRILLING OR CUTTING SHLL BE REMOVED IMMEDITELY FROM FINISHED SURFCES. B. INSTLLTION TOLERNCES: SPECIL DOORS SHLL BE PLUMB, LEVEL, ND LIGNED WITHIN N INSTLLED TOLERNCE OF 1/4-INCH IN 20 FEET ND WITHIN 1/8-INCH ONSET OF DJOINING FCES ND OF LIGNMENT OF MTCHING PROFILES. C. T THE COMPLETION OF THE INSTLLTION, CHLK TEST IS TO BE PERFORMED TO DETERMINE THE CTUL CONDITIONS OF THE SPECIL DOORS. END OF SECTION specifications watertight closures 11-2008last saved Wednesday, November 25, 2009 Page 5 of 6