MESSKO MTraB product line (see application table page 3) MESSKO MTraB connection requirements

Similar documents
MESSKO MTO Oil Level Indicator

Protective cover with powder coating. Protective cover with directed oil flow (OD cover)

MESSKO COMPACT SERIES OIL TEMPERATURE ORDERING SPECIFICATIONS.

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve

Step 1: Collection of required data

CONA -control Monitoring system for steam traps

Cast resin transformers

Field IT Actuators & Positioners Rotary Actuators - Rated Torque 100 Nm (80 ft-lbs) PME 120-AI/AN. Rotary Actuators Rated Torque 100 NM (80 ft-lbs)

Max. particle size 50 µm Max. oil content of compressed air

T 3965 EN Type 3965 Solenoid Valve Island To control pneumatic actuators

EPS/ELA-Series User Manual EPS/ELA 250W

VEO. V2TF01 Art.Nr.: V2TF01P Art.Nr.: TECHNICAL DATA

We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.

AC/DC Arc Furnace and Ladle Furnace Transformers

Contactors. CL1115/02, CL1215/02, CL1315/02 1, 2 and 3 pole AC and DC NO contactors for voltages up to 1,500 V Catalogue C25.en

Magnetic Overcurrent Circuit Breaker

SAV Electronic Valve Actuator

SD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches,

Max. oil content of compressed air

Valve series KN-05 acc. to NAMUR, 3/2-way G1/4 780 Nl/min (0.792 Cv)

Electronic Ballast EVG 2000-T

S10010 / S SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS 10/20 Nm (88/177 lb-in) FOR MODULATING AND FLOATING CONTROL SPECIFICATIONS GENERAL

4 x 0-10Vdc Channels Fused 24V o/p terminals for actuator power Direct or buffered output signals

Pressure regulators E/P pressure regulators Series ED05. Brochure

Solenoid Valve Island Type 3965

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

RSDE10 / RSDE20 (Contrac) Electrical Linear Actuator

Contactors. CH1130/02 Series Single pole high-voltage contactor up to 3 kv Catalogue C170.en. Connect - Contact - Control

Regenerative DC Common Bus Supply

GV-A Manufactured by Germany s Elster GmbH High-Performance Gas Solenoid Valve for Industrial Applications

Integrated Control modules

Compact Sheet-Steel Light Fittings Series 6114/1

Scheda prodotto Relè Series E

1291BL Series Technical Specification Single Axis Position and Rate Table System

Electronic Circuit Breaker ESS20-0..

MN-06. Standardized valve series 3/2-way acc. to NAMUR, 750 Nl/min (0.762 Cv) Technical data for series. Order code MN HN-142

Fieldbus Segment Protector F2-SP-IC* Features. Assembly. Function. Connection. Zone 2 Div. 2

Moving Coil Indicators with direct temperature sensor input

Buchholz Relay MBP Gas and Oil Actuated Relay

Heating oven with mechanical convection

Pressure regulators E/P pressure regulators Series ED02. Brochure

Chapter 06 Accessories ACCESSORIES

OPEN/CLOSE SERVICE ELECTRIC ACTUATORS OPERATION AND MAINTENANCE MANUAL COMMERCIAL AND INDUSTRIAL VALVES AND AUTOMATION

Product features & Overview. KA Linear actuators

MN-06. Standardized valve series 3/2-way acc. to NAMUR, 750 Nl/min (0.762 Cv) Technical data for series. Order code MN HN-142

Climate chambers with illumination

Direct Coupled Damper Actuator Model MY9050A1001

Proportional directional valve, pilot-operated, with integrated electronics (OBE)

Special voltages: Voltage >500 V AC are only permissible with external control box. 3-phase AC Voltages/frequencies. 1-phase AC Voltages/frequencies

Pressure regulators E/P pressure regulators Series EV07. Brochure

Compact Sheet-steel Emergency Light Fitting Series 6118/1

CAST RESIN TRANSFORMERS

S1024-2POS / S POS S2024-2POS / S POS

Differential pressure switches for air, flue and exhaust gases Pressure switch for gas

2.7. IT system floor-standing distribution cabinet Series -IPS-F

OIL LEVEL GAUGES FOR DISTRIBUTION TRANSFORMERS

DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Contents. Part no.: MLC510R Safety light curtain receiver

Linear Valve Electric Actuator

Level Limit Switch soliphant FTM 930/931/932/ Z

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

1291BL Series Technical Specification Single-Axis Rate and Positioning Table System

SentronicPLUS IO-Link CLASS A Electronic Pressure Regulator. Installation Manual

THERMOMETERS For distribution transformers

Climate chamber with illumination

Heating chamber with mechanical convection

Direct Coupled Damper Actuator Model MY6050A1001

EX Series. Electric Actuators for Ball and Butterfly Valves

RSD100 (Contrac) Electrical Linear Actuator

Rittal TopTherm Filter Fans

Process controller. for pneumatic and electric actuators. Process controller V. Process controller

Model ED 720 Drying and heating chambers Classic.Line with natural convection

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

Linear actuator. Product features. Overview. Wide range of force outputs. Wide selection of column adapters. Wide selection of flanges

XMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO.

Features. Type List. Enclosure style. Terminal style. Contact. Sealed type washable. form Dust cover Flux tight

Contactors. C110B/80, C110B/120 C110B/200, C110B/300 Single pole DC NO contactors for industrial trucks Catalogue B71.en

Twin relays. Twin coil relays TCR and TCR-F. Convenience. Powertrain Systems. Safety Security Body Driver Information.

3RT14 Contactors with 3 Main Contacts

EAS822 (Contrac) Power Electronic Unit

Current transformers. Current transformers

THYRO-A DIGITAL THYRISTOR SCR POWER CONTROLLERS 8 TO 1500 AMPS

better measurement Simply a question of

3/2 Directional Control Valves Direct solenoid operated poppet valves Internal thread G1/4, 1/4-18 NPT or flanged with NAMUR interface

Low voltage AC drives. ABB component drives ACS to 2.2 kw / 0.25 to 3 hp Catalog

Electrically operated valves Series KM-09, 5/2- and 5/3-way G1/8 680 to 950 Nl/min (0.691 to Cv)

Heating chamber with mechanical convection

ENYSTAR Load Centers up to 250 A

M Series 010.D Data Sheet. Analog Meters with Moving-Coil Movement, 90 Dial PSQ 48 PQ 72 RS PQ 96 RS PQ 144 RS

Integrated Control modules

JUMO MIDAS Pressure transmitter

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

4 pole insulated conductor rails UNILIFT-ULA 35A, 50A, 80A, 100A

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G V

EX Series. Electric Actuators for Ball and Butterfly Valves

5-Phase Stepper Motor

TRANSPORT. Take all the necessary precautions to prevent the load from knocking against the vehicle during transport. - 1/5 -

MOTOR DRIVE UNITS FOR TAP CHANGERS... 2 [ MOTOR DRIVE UNIT MZ 4.4 WITH SINGLE-PHASE EL. MOTOR ]... 3 DRIVE UNITS FOR REPLACEMENT...

LINE CONDITIONERS USER'S GUIDE

Transcription:

Dehydrating Breather Technical data Product variants This technical document contains detailed information about the technical properties of the product. If you would like to place an order, please use the MESSKO inquiry and order specification, which you can also find on our website http://www.reinhausen.com below the respective product. 1 2 3 4 product line (see application table page 3) DB100 DB100T DB200T DB200D-T (duplicate) DB200G γ-controller (duplicate) Protective coating color Offshore model RAL 7033 standard cement gray RAL 7038 standard agate gray connection requirements Not available in offshore model Includes: Flange with offshore finish Connection box with offshore finish and with C5-M coating Cable screw connection with stainless steel finish (1.4404) Further designs available upon request Cable screw connections 3x M20x1.5 Nickel-plated brass 3x 1/2-14 NPT Nickel-plated brass Analog output 4...20 ma 40...+80 C 0...20 ma 40...+80 C 0...1 ma 40...+80 C Mounting flange DIN flange; similar to DIN 42 562-3; see [ 5] No. 1 RM flange; in accordance with DIN 2558; only for type DB100; see [ 5] No. 2 5 Flange for 1/2" screws; see [ 5] No. 3 6 7 8 Customer-specific flanges by request Supply voltage 120 V ± 10% DC 120 V ± 10% AC, 50/60 Hz Accessories Data logger 230 V ± 10% DC 230 V ± 10% AC, 50/60 Hz Additional overvoltage protection for 230 V AC Insect protective grate for stainless steel filters Recommended in the case of known overvoltage problems outside of the specification of up to 400 V (e.g. voltage spikes during switching procedures). With or without software (CD) and USB cable; see [ 4] See [ 11]; not together with filter heater Spiral coiled hose for protection of electric lines against damage (e.g. animal biting) Filter heater (in High Temperature (HT) version for applications in cold regions, see [ 2]) Test button Only for AC variant; see [ 4] Fastening to the side See [ 6] and [ 7] Protective grate See [ 11] Messko GmbH 2018 TD5787543-00 EN 1

Dehydrating Breather Operating conditions Site of operation Technical data Indoors and outdoors Ambient temperature DB100/200/200D: 0...+80 C / as HT version* 50...+80 C DB200G: 0...+70 C / as HT version* 20...+70 C *) HT version for applications in cold regions, e.g. ambient temperature is continuously below 0 C over a time period of 20 days. Degree of protection IP 55 in accordance with DIN EN 60 529 IP 66 in accordance with DIN EN 60 529 for offshore model Contamination level General Materials Color Weight 4 under outdoor conditions 2 inside of the connection box Dimensions See [ 6] and [ 7] Flange connection See [ 5] Desiccant Power supply All exterior parts weather-proof, oil-resistant and UV proof transformers; saltwater-proof model (offshore) by request Flange and metal parts: anodized (aluminum); connection box: powder-coated RAL7033 (cement gray) or RAL7038 (agate gray) DB100(T): approx. 8 kg; DB200T: approx. 12 kg; DB200D-T: approx. 23 kg; DB200G: approx. 31 kg Colorless, nontoxic silica gel; Quantity according to the following Application table [ 3] Nominal voltage 230 V AC 50/60 Hz or 230 V DC; tolerance ± 10% Power consumption External fuse protection RM version*: 120 V AC 50/60 Hz or 120 V DC; tolerance ± 10% *) Version for the US market Max. 100 ma (in normal operation); Increased power consumption during regeneration; 2 ) Heat current corresponds to the following Application table [ 3] 16 A miniature circuit breaker, C-characteristic; takes into account the switch-on current of the heater Rated insulation voltage 500 V DC (L to PE, N to PE, see [ 4]) Max. heat output 1 ) Values in accordance with the following Application table [ 3] Terminal box Cable screw connection Connection terminals Status display Fuse Signaling contacts Type of contact Contact load Utilization category Analog output Output Output signal Load resistance Options Offshore Data logger Ventilated and heated for the prevention of water condensation M20x1.5 or 1/2" 14 NPT nickel-plated brass M20x1.5 also available in stainless-steel for offshore applications 2.5...4 mm 2 ; AWG 24 10; rigid or flexible 3 LEDs visible from outside; 2 LEDs inside the connection box for service purposes 250 V/1 A/5x20/fast-acting; not included for the pre-transformer option 1 x changeover contact, silica gel regeneration signaling relay 1 x normally closed contact, device error signaling relay (fail safe) Max. 5 A/230 V AC or 5 A/24 V DC (for ohmic load) IEC 60947-5-1 AC-15/DC-13 40...+80 C (temperature in the pipe nozzle) 4...20 ma (0...1 ma or 0...20 ma are optional); Error signal < 3.6 ma (for 4...20 ma output signal) Maximum: R LMax =850 Ω Load influence: 0.01%/100 Ω As per the requirements in accordance with DIN EN ISO 12944 part 5 with corrosion-protection class C5-M Recording important MTraB results; analysis by means of visualization software; data connection via USB jack, type B 2 TD5787543-00 EN Messko GmbH 2018

Dehydrating Breather Options Insect grille Use in the dust protection tube, not shared with filter heater, see [ 11] Cable protection Filter heater Protects the cable against damage such as animal biting, designed as a spiral coiled hose (stainless steel, suitable for offshore applications) HT version: With heated stainless-steel filter; recommended for cold regions with an ambient temperature that is continuously below 0 C for more than 20 days in order to guarantee proper functioning Switching point: < 5 C (switch on) Test button Only for AC variant: To start the device self-test and to test the silica gel heater, see [ 4] Fastening to the side See [ 6] and [ 7] Protective grate See [ 11] Application table Application MTraB type Max. heating power 1 with Heat current 2 with U V = 120 V U V = 230 V U V = 120 V U V = 230 V Tap changer DB100 480 W 960 W 1.2 A 0.6 A 1.1 kg α Arc suppression coil (Petersen coil) DB100 480 W 960 W 1.2 A 0.6 A 1.1 kg α Air-filled cable boxes DB100 480 W 960 W 1.2 A 0.6 A 1.1 kg α Vehicle transformers DB100 480 W 960 W 1.2 A 0.6 A 1.1 kg α Network transformers 40 MVA DB100T 480 W 960 W 1.2 A 0.6 A 1.1 kg β Network transformers and step-up transformers > 40 MVA 200 MVA Silica gel Control 3 DB200T 960 W 1780 W 2.3 A 1.2 A 2.2 kg β Network shell transformers > 200 MVA DB200D-T or 2 x DB200T 4 1920 W 3680 W 4.7 A 2.4 A 4.4 kg β Phase shifter 40 MVA DB100T 480 W 920 W 1.2 A 0.6 A 1.1 kg β Phase shifter > 40 MVA 200 MVA DB200T 960 W 1780 W 2.3 A 1.2 A 2.2 kg β Phase shifter > 200 MVA DB200D-T or 2 x DB200T 4 1920 W 3680 W 4.7 A 2.4 A 4.4 kg β Reactors 40 Mvar DB100T 480 W 920 W 1.2 A 0.6 A 1.1 kg β Reactors > 40 Mvar 200 Mvar DB200T 960 W 1780 W 2.3 A 1.2 A 2.2 kg β Reactors > 200 Mvar DB200D-T or 2 x DB200T 4 1920 W 3680 W 4.7 A 2.4 A 4.4 kg β High voltage DC transmission (HVDCT) transformers DB200D-T or 2 1920 W 3680 W 4.7 A 2.4 A 4.4 kg β x DB200T 4 Furnace transformers DB200G 960 W 1780 W 2.3 A 1.2 A 4.4 kg γ Underground hall transformers DB200G 960 W 1780 W 2.3 A 1.2 A 4.4 kg γ GSU machine transformers DB200G 960 W 1780 W 2.3 A 1.2 A 4.4 kg γ 1 ) Temporary maximum heat performance (peak) at the beginning of the regeneration process. The power consumption drops quickly after heating activation. 2 ) Heating current during the heating process (approx. 1-2 min. After heating activation). 3 ) α-control: State-dependent control of the heating process by monitoring the humidity. β-control: Self-learning system with state-dependent control of the heating procedure through humidity monitoring and temperaturedepend-ent determination of the most advantageous time to perform heating. γ-control: System for applications with non-periodic breathing behavior. By monitoring the air humidity, the dehydrating chambers are regen-erated in alternation based on the status. 4 ) Mount individually on the conservator tank, no parallel mounting, see the Dehydrating Breather operating instructions. Messko GmbH 2018 TD5787543-00 EN 3

Dehydrating Breather MTraB connection box with data logger and cable screw connections Figure 1: MTraB connection box 1 Regeneration signaling relay (contacts 6, 7, 8) 2 Device error signaling relay (fail safe; contacts 4, 5) 3 Supply voltage connection (contacts 1, 2, 3; 2a only for optional overvoltage protection) 4 Microfuse for control electronics 5 Spare fuse (250 V/1 A/5x20/fast acting) 6 Device error red LED (outdoors) 7 Regeneration heater yellow LED (indoors) 8 Operating status green LED (outdoors) 9 Connection box anti-condensation heater yellow LED (indoors) 10 Filter heater yellow LED (indoors) 11 Data interface USB jack, type B (for data loggers) 12 Test button (optional; only for AC variant) 13 Data logger (optional) 14 Analog output (contacts 9+, 10 ) and shield (contact 11) 15 Grounding connection between housing and cover 16 Cable screw connection for M20x1.5 or 1/2" 14NPT supply lines 4 TD5787543-00 EN Messko GmbH 2018

Dehydrating Breather Dimensions for flange connection with DIN flange, RM flange or circular flange for 1/2" screws Figure 2: MTraB flange connections (customer-specific flanges by request) 1 DIN flange similar to DIN 42 562-3 2 RM flange in accordance with DIN 2558 3 Circular flange for 1/2" screws Messko GmbH 2018 TD5787543-00 EN 5

Dehydrating Breather MTraB DB100/DB200 dimensions with additional fastening points (optional) Figure 3: MTraB DB100/DB200 with additional fastening points on the side 1 Additional fastening points on the side (optional) 2 M8x20 DIN 933 hex head bolt MTraB dimensions with flange Model type DB100 Model type DB200 L H* L H* DIN flange 459 mm / 18.06" 634 mm / 24.96" 689 mm / 27.11" 781 mm / 30.75" RM flange 463 mm /18.22" 638 mm / 25.12" 1/2" screws 459 mm /18.06" 634 mm / 24.96" 689 mm / 27.11" 781 mm / 30.75" 6 TD5787543-00 EN Messko GmbH 2018

Dehydrating Breather MTraB DB200D-T dimensions with additional fastening points (optional) Figure 4: MTraB DB200D-T with additional fastening points on the side 1 Additional fastening points on the side (optional) 2 M8x20 DIN 933 hex head bolt Messko GmbH 2018 TD5787543-00 EN 7

Dehydrating Breather MTraB DB100/DB200 with cable protection (optional) Figure 5: MTraB DB100/DB200 with cable protection; the dash-dot line indicates the cable routing. 1 Cable protection (optional) 2 Separation distance for cable protection MTraB dimensions with flange Overall height L DB100 DB200 DIN flange 459 mm / 18.06" 689 mm / 27.11" RM flange 463 mm / 18.22" 1/2" screws 459 mm / 18.06" 689 mm / 27.11" 8 TD5787543-00 EN Messko GmbH 2018

Dehydrating Breather MTraB DB200D-T with cable protection (optional) Figure 6: MTraB DB200D-T with cable protection; the dash-dot line indicates the cable routing. 1 Cable protection (optional) 2 Separation distance for cable protection 3 Wall fastening for cable Messko GmbH 2018 TD5787543-00 EN 9

Dehydrating Breather MTraB DB200G with gamma control Figure 7: MTraB with gamma control 1 Electric ball valve 2 Connection cable for supply unit and ball valve limit switch 10 TD5787543-00 EN Messko GmbH 2018

Dehydrating Breather MTraB with protective grate and insect protective grate (both optional) Figure 8: MTraB with protective grate and insect protective grate 1 Protective grate for MTraB DB100 2 Protective grate for MTraB DB200 3 M6x20 hexagon socket 4 Insect protective grate 5 Dust protection tube Messko GmbH 2018 TD5787543-00 EN 11

Messko GmbH Gewerbegebiet An den Drei Hasen Messko-Platz 1 61440 Oberursel, Germany +49 (0)6171 6398 0 +49 (0)6171 6398 98 messko-info@reinhausen.com www.reinhausen.com/messko TD5787543-00 EN - - F0357700-02/18 - Messko GmbH 2018 THE POWER BEHIND POWER.