R130/R135 TH-170 MANUAL MANUAL. Universal hardness tester. Roughness tester

Similar documents
MANUAL R-130 / R-135

ROUGHSCAN SURFACE ROUGHNESS TESTER OPERATIONAL MANUAL

MARSURF PS1 I ABSOLUTE MOBILITY FOR SURFACE ROUGHNESS MEASUREMENTS

ABS System. Inductive Digital Comparator µmaxµm. Features. Technical Data. The most valueable electronic indicator for high production measurements.

Installation Instructions

POCKET-TACH 100 MONARCH INSTRUMENT Rev 1.4. Instruction Manual. Printed in the U.S.A. Monarch Instrument 2001 all rights reserved

Instruction Manual. Coating Thickness Gauge. Optionally with Memory

PORTAGAUGE 4 USER MANUAL

Height Master Page 345. Check Master Page 349. Calibration Tools Page 354

PosiTest. Pull-Off Adhesion Tester. INSTRUCTION MANUAL v PosiTest AT-M (manual) PosiTest AT-A (automatic)

Installation Guide. Electronic Entry Device. LA GARD Basic & Gard Series

Hand Held Pull Tester Instruction Manual Order No

Installation Instructions

INSTRUCTION MANUAL VISCOTESTER VT-05 / VT-06 PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

Small Tool Instruments and Data Management

Operators Manual. True RMS Voltstik. Radio Linked Multiple Reading Voltmeter. SensorLink

Miniature resistance thermometer For sanitary applications Model TR21-A, with flange connection

225 CARTRIDGE DUAL SEAL

Installation Instructions Series

3. Operating instructions: Minor 200

1732-M2 Portable C-Frame Punch Driver

ELECTRONIC ENTRY DEVICE INSTALLATION INSTRUCTIONS FOR BASIC AND GARD SERIES

DC POWER SUPPLY ALIMENTATION C.C.

CALIBRATION SYSTEM CERTIFICATE

OPERATION MANUAL MODEL MODEL MODEL MODEL MODEL NON-CONDUCTIVE ARTICULATING FIBERSCOPE INSTRUMENT TECHNOLOGY, INC.

INSTALLATION INSTRUCTIONS STUDIO S

Small Tool Instruments and Data Management

Ohaus ES Series Bench Scale

Instruction Manual. Vibration Severity Meter VM12

Thermo-Anenometer Model Owner s Manual

Installation Instructions

Gauge Blocks - Reference for Precision

Standard Scales SERIES 182 Made of Low-Expansion Glass. Working Standard Scales SERIES 182 E-32

TABLE OF CONTENTS 11.0 WARRANTY

746 Wrist Strap Tester Installation, Operation and Maintenance

Installation Instructions

Megohmmeter Test Probe

20 TONNE HYDRAULIC PRESS MODEL NO: CSA20FBT

PosiTest. Pull-Off Adhesion Tester. INSTRUCTION MANUAL v PosiTest AT-M (manual) PosiTest AT-A (automatic)

USER GUIDE. Model RH10 Hygro Thermometer. Humidity and Temperature Meter

Operating manual. ZSK Automatic Bobbin Winder 230V 50Hz/60/Hz / Z

INSTALLATION INSTRUCTIONS PATIENCE

Check Points. for Measuring Instruments

Users Manual. Phase Rotation Indicator

Injector. General Information CAUTION. Use only the specified injector for the engine.

JUL 17 Rev M

Installation Instructions

255 Cartridge Dual Seal

NOTES TABLE OF CONTENTS

AXIAL FANS Axis / Tubo OPERATION MANUAL

SERIES OPERATION AND MAINTENANCE MANUAL

Coating Thickness Gauges

User's Manual. Earth Ground Resistance Tester. Model Introduction

TESA IMICRO capa µ system with Digital Display

OWNER S MANUAL. Model 9880 Intrinsically Safe Air Velocity Meter

LEM~flex RR3020 AC Current Probe Operating Instructions Mode d emploi Bedienungshandbuch Manuale Operativo Manual de uso

Operation Manual FLG-G5 Transtech Gravity Spray Gun SB-E ISS.05

Users Manual. Accessories Motor and Phase Rotation Indicator ships with the following items: 3 test leads 3 test probes 3 alligator clips 9 V battery

Thermowell For sanitary applications Model TW22

Electric Hi Lo Screen lift Trolley Mount 8960

250L Cartridge Dual Seal

New. Swiss Promo. Shop Proof Technology. TESA-HITE Magna 400 and TESA-Cal. Validity : All prices with VAT excluded

Excellence in Level Measurement


362 Clamp Meter. Users Manual

MODEL 905V OPERATING INSTRUCTIONS

Model 8340 Intrinsically Safe VELOCICHECK Air Velocity Meter

Indoor Air Quality Meter

ELECTRICALLY OPERATED TORQUE WRENCH (VC-RAD) USER GUIDE

THE NEW JET METALFORMING LINE UP STAND BEHIND YOUR WORK 550+ SERVICE CENTERS NATIONWIDE INDUSTRY-LEADING WARRANTIES EXPERT TECHNICAL SERVICE

COATING THICKNESS GAGE NOVOTEST TP-1

Defender 3000 Series Base Instruction Manual

TIMKEN DEEP GROOVE BALL BEARINGS

SETTING ZERO S cont. IF THE ZERO REPEATS WITHIN +/- 1.0 LB THEN YOU ARE READY TO CHECK SPRINGS. PAGE 4 OF 9

Operators Manual. Qualstik PLUS. Live-Line Power Quality Survey Meter. SensorLink

Variable Regulated Voltage Power Supply Instruction Manual Model XP-605 / XP-752A

SAMPLES GAUGES. Tolerances OUR SPECIAL OFFER: PLUG GAUGES WITH REQUIRED FIT OR INDIVIDUAL TOLERANCES ACCORDING TO YOUR SPECIFICATIONS

Eaton. Repair Information. Model and Piston Motors Fixed Displacement, Valve Plate Design. Medium Duty Piston Pump NO.

EDGEMERE DUAL CONTROL WIDESPREAD LAVATORY FAUCET INSTALLATION INSTRUCTIONS

Thermowell For sanitary applications Model TW61, for orbital welding

MOdel No: MM19.V3 WARNING CAUTION 1. SAFETY INSTRUCTIONS

Solar Power Light Meter

Adam Equipment CPW COMPACT SCALE

Thermocouple Thermometer Models

OPERATING INSTRUCTION

INSTALLATION INSTRUCTIONS

OPERATING INSTRUCTIONS. HTL-DSX Dedicated Square Drive Wrench

UNISON CORPORATION. DedTru Centerless Grinding Product Line

Installation Instructions

Penetration. Test Methods

MultiCal. Operation Manual for MultiCal mmhga/psia Pressure Module

Thermistor Thermometer MODEL NO

Electronic Entry Device Installation Instructions

Alfa Laval Toftejorg Rotary Spray Heads MultiMidget & MultiMagnum

Pressure measurements can easily be taken any time, anywhere. POWER LIGHT

FSG-2A818/3A818 HIGH PRECISION SURFACE GRINDER

Lever Type Dial Indicators Dial Test Indicators

VQ400M SERIES CLASS A COMBINATION VALVES INSTRUCTION SHEET APPLICATION

Datasheet PDCSY-MW-CHM. Technical Overview. Features. Product warranty and total quality commitment. General Information.

This manual covers the following model:

Transcription:

MANUAL R130/R135 MANUAL TH-170 Roughness tester Universal hardness tester

Changes in products and/or product specifications can emerge due to new technologies and continuous development. We reserve the right to change or modify specifications of products without prior notice. We recommend you to contact our sales office for up-to-date information. All rights reserved 2 www.innovatest-europe.com

Contents 1. Description 2 2. Specification 3 3. Measurement parameters 4 4. Features 5 5. Battery installation/replacement 6 5.1 Controls and digital display 6 6. Calibration 8 7. Operation 10 8. Probes 11 8.1 General purpose probe 11 8.2 Transverse chisel probe 11 8.3 Parallel chisel probe 11 8.4 Small bore probe 12 8.5 Groove bottom probe 12 9. Probe replacement 13 10. Analog signals output 14 11. Maintenance 15 11.1 Protection & storage 15 11.2 Cleaning 15 11.3 Repairs 15 12. Accessory: height stand 16 www.innovatest-europe.com 1

1. Description The R130 tester is a portable, battery-powered instrument for checking surface roughness with the measured values displayed on a digital readout. The instrument can be used in the laboratory, an inspection area, in the shop, or wherever on-site surface roughnesss testing is required. NOTE: Even though this instrument is designed and built to withstand the rigors of handling and use,it is a precision instrument and should be treated with care to assure measurement accuracy and reliable performance. R130 standard kit is furnished in a fitted case and includes: - R130 unit with a general purpose probe (R130-2002) - reference specimen - 9-volt alkaline battery - riser plate for calibrating the gage with the reference specimen - screwdriver. 2 www.innovatest-europe.com

2. Specification - Measuring ranges : Ra--0.03µm~6.3µm/1µ ~250µ Rz--0.2µm ~18.5µm/8µ ~999µ - Display Resolution: 0.01µm /1µ - Cut-off: 0.25mm/0.8mm/2.5mm, ANSI 2RC Filter - Display: 3-digital LCD - Measure Accuracy: Meets ISO and DIN standards Traverse lengths and evaluation lengths: Cut-off = 0.25mm Traverse length Evaluation length Numbers of cutoff 0.75mm 0.25mm 1 1.25mm 0.75mm 3 1.75mm 1.25mm 5 Cut-off = 0.8mm Traverse length Evaluation length Numbers of cutoff 1.2mm 0.8mm 1 3.0mm 2.4mm 3 4.5mm 4.0mm 5 Cut-off = 2.5mm Traverse length Evaluation length Numbers of cutoff 3.0mm 2.5mm 1 - Probe type : Piezoelectric - Maximum stylus force: 15.0mN / 1500mgf - Power: 9-volt consume-type alkaline battery - Battery capacity: Approx. 3000 measurements - Operating temperature:10 ~45 C / 50 ~113 F - Storage temperature : 0 ~60 C / 32 ~147 F www.innovatest-europe.com 3

3. Measurement parameters - Ra Roughness Average---the arithmetic average height of roughness irregularities measured from a mean line within the evaluation length (L) - Rz Maximum Roughness Depth ---The largest of the peak_to_valley roughness depths in the evaluation length. 4 www.innovatest-europe.com

4. Features 1 Digital display 2 Start button 3 Parameter selection button 4 Cut-off selection switch 5 Traverse length switch 6 Meter/inch switch 7 Output connector (accessory) 9 Battery (alkaline) 10 Battery compartment cover 11 Protective cover 12 2 V feet 13 Probe holding block 14 Probe www.innovatest-europe.com 5

5. Battery installation /replacement (Alkaline only) 1. Remove protective cover from the gage base and slide battery compartment cover off end of the gage. 2. Install/replace alkaline battery and replace battery compartment cover. 3. Set On/Off, push START to check battery condition (see next section) 5.1 Controls and digital display Cut-off selection switch Traverse length switch Digital display Start button Metric/Inch switch Parameter selection button 1. Set power switch for START, it should display 1-000. If it no display or display 8-888, it indicating weak battery, and must remove and replace the battery. 2. Set Metric/Inch switch for metric (µm) or inch (µ ). Set Cut-off selection switch for 0.25mm, 0.8mm, 2.5mm, base on the roughness value be estimated. Refer to Table 1. Set traverse length switch for 1, 3 or 5. Refer to specification section s traverse length for detail. 3. Press and release start button, the readout should display 1-X.XX (Ra). If the readout display 8-888, it indicating a low battery, and need to replace the battery. 4. If the Ra or Rz value displayed is out of the measuring rang which accordance with the selected Cut-off, then re-select the cut-off. Refer to table 1. 5. The digital readout also can display 2-X.XX (Rz) in circularly by press and release the parameter selection button. 6 www.innovatest-europe.com

Table 1: Measuring ranges Measuring ranges (Ra) (Rz) Cut-off (lc) 0.03µm Ra 0.1µm 0.1µm Rz 0.5µm 0.25mm 0.1µm<Ra<2.0µm 0.5µm<Rz<10.0µm 0.8mm 2.0µm Ra 6.3µm 10.0µm Rz 50.0µm 2.5mm The tester can be switch on with the > (start) key and be turned off automatically after 2 minutes. If the tester is auto switched off, the last measuring result can t be shown on the screen when re-start the tester as this auto-off is the real off (power cut-off). www.innovatest-europe.com 7

6. Calibration Prior to operating the tester, its calibration should be checked. 1. The tester is calibrated using the reference specimen. Set cut-off selection switch to position 0.8mm, set the traverse length switch to position 5, and set the metric/ inch switch to position metric. Place the specimen into the groove of the calibration plate, place the tester on the calibration plate. Make sure that the probe stylus was in the middle of the specimen. Probe Calibration control Calibration plate 2. Press and release the start button, and take a reading from the center of the specimen. If the reading is within ±0.1µm of the value stated on the report of calibration certificate, calibration is within tolerance. If the reading differs from the value stated on the report of calibration certificate by more than ±0.1µm, take additional readings around the central area of the specimen. If the reading still differ by more than the allowable tolerance, recalibrate the tester following the procedure below. 3. Using a screwdriver, carefully adjust the calibration control. Clockwise to increase the displayed Ra value, or Counter clockwise to decrease the displayed Ra value. 4. After adjusting the calibration control, remeasure the reference specimen to assure that the tester is within the calibration tolerance. 8 www.innovatest-europe.com

5. When calibrating with a Small Bore Probe or Groove Bottom Probe, the probe should be in the 180 position. And make sure that the tester base is on the same height as the surface of the calibration specimen. calibration plate or height stand www.innovatest-europe.com 9

7. Operation The tester will operate in any one of four probe positions. Selection of the proper probe position depends on the application. When changing probe positions, gently grasp the probe by its body; never handle the probe by its skid and stylus end. During the measuring cycle, the probe stylus and skid should be in contact with a surface, and the setup should be properly aligned. Otherwise, any readings obtained are not valid and are not to be used for measurement or tester performance evaluation purposes. The tester can be hand held or placed on a surface in any attitude, it will operate in virtually any position ---horizontally, vertically, at any angle in between, even upside-down. With the probe positioned on the workpiece surface to be measured, carefully adjust the tester and workpiece setup, so that the Reference Line (the upside of the Probe Mounting Block) is parallel to the bottom of the tester housing and parallel to the workpiece s surface (see below).this ensures that the probe skid and stylus are flush on the work surface, even though the probe body will be at an angle to the work surface. 10 www.innovatest-europe.com

8. Probes 8.1 General purpose probe (R130-2001 or R130-2002) For most surface roughness applications. R130-2001 has a 90 conical diamond stylus,.0004 /10µm radius per ISO specifications. R130-2002 has a 90 conical diamond stylus,.0002 /5µm radius per DIN standards. 8.2 Transverse chisel probe (R130-2003) For gaging sharp edges or small O.D. s where probe is aligned with (in 180 or closed position) to axis of traverse. 90 diamond chisel stylus,.0004 /10µm radius. 8.3 Parallel chisel probe (R130-2004) For gaging sharp edges or small O.D. s where probe is perpendicular(in 90 or 270 position) to axis of traverse. 90 diamond chisel stylus,.0004 /10µm radius. www.innovatest-europe.com 11

8.4 Small bore probe (R130-2005 or R130-2006) For measuring small bores (min. inside diameter of 5.0mm,up to a depth of 15.0mm). 90 conical diamond stylus,.0004 /10µm radius for R130-2005;.0002/5µm radius for R130-2006. 8.5 Groove bottom probe (R130-2007) For measuring the bottoms of O ring grooves, recesses and holes to depth of 6.0mm. Also used for short lands and shoulders. 90 conical diamond stylus,.0004 /10µm radius. 12 www.innovatest-europe.com

9. Probe replacement 1. Turn the tester upside down and swivel the Probe to its 90 position. 2. Loosen the knurled locking collar by turning it counter-clockwise approximately 3 turns, until the access solt is aligned with the probe pin solt in the probe mounting block. Grasp the probe by its body section, carefully withdraw the probe from its mounting blockand the knurled locking collar. Do not grasp the probe by its skid and stylus end. Do not remove the knurled locking collar from the probe mounting block,loosen it only enough to slide the probe out easily. 3. Reverse the procedure to install a probe, aligning the pin on the bottom of the probe body with the acess solt in the locking collar. Make sure that the probe is fully inserted into the probe mounting block(so that the electrical connector is completely engaged) before tightening the locking collar. Finger tighten only. 4. Check the tester s calibration after changing probes. www.innovatest-europe.com 13

10. Analog signals output The tester digital signals output feature permits measurement results to be transmitted to an external device such as a printer, computer or data collection system. For further information concerning the signals output, please contact the supplier. Printer settings TA-220 settings TA-230 settings 1 + 3 + 5 = on 2 + 3 + 6 + 7 = on 14 www.innovatest-europe.com

11. Maintenance 11.1 Protection & storage To protect the tester when not in use, always return the probe to its closed position and replace the protective cover on the tester unit. Also, when not in use, always keep the tester and its accessories in the fitted case. 11.2 Cleaning To clean the tester unit, use a soft, lint-free cloth moistened with a mild, non-abrasive, liquid or foam cleaning agent. Using a magnifier, periodically inspect the probe skid and stylus area for dust, dirt or other contamination. To clean the probe skid and stylus, use a soft (camel s hair), artist s brush moistened with denatured alcohol. 11.3 Repairs When finded any trouble in using the tester, contact the suppliers. Do not disassemble the unit or attempt any further remedies. www.innovatest-europe.com 15

12. Accessory: height stand The height stand is intended to be used on a surface plate or other suitably flat surface to measure workpiece surfaces ranging in height from flush with the work surface to a maximum height of approximately 175mm. The tester probe can be in either its 90 or 180 position. 1. Mount the tester in the bracket on the height stand using the captive screw in the base of the bracket. The screw mates with the tapped hole in the bottom of the tester housing. Tighten the screw by finger. 2. Position the height Stand so that the probe is above the workpiece surface to be measured. Use the coarse height adjustment to bring the probe skid and stylus barely in contact with the surface. Use the fine adjustment to make the reference line (the upside of the mounting block) parallel to the bottom of the tester housing. 3. Once the setup is correctly adjusted, and the probe is properly positioned on the workpiece surface, gently press and release the start button on the tester to make the measurement. Fine adjustment Coarse adjustment Captive screw Bracket 16 www.innovatest-europe.com

EC-Declaration of Conformity This certifies that the following designated product R130/R135 (Portable roughness tester) complies with the essential protection requirements of Council Directive 89/336/EWG approximation of the laws of the Member States relating to electromagnetic companies. This declaration applies to all specimens manufactured in accordance with the manufacturing drawings which form part of this declaration. Assessment of compliance of the product with the requirements relating to the compatibility was based on the following standards: EN55022, EN60555-2, EN60555-3, EN50082-1 This declaration is the responsibility of the manufacturer/importer: Company name: INNOVATEST Europe BV Address: Borgharenweg 140 Telephone / Telefax: +31-43-3520060 / +31-43-3631168 Name of the subscriber: Nicole Paulissen-Schiffer Position: General Manager Maastricht City Authorised representative signature www.innovatest-europe.com 17

IN09-115 060715 CORPORATE HEAD OFFICE INNOVATEST Europe BV MANUFACTURING, DISTRIBUTION & SERVICE Borgharenweg 140 6222 AA Maastricht (The Netherlands) Phone: +31 43 3520060 Fax: +31 43 3631168 E-mail: info@innovatest-europe.com Website: www.innovatest-europe.com