Test Report No. AJHL FB Date: OCT.26, 2016 Page 1 of 6

Similar documents
Test Report No. AJHL FB Date: JUN.21, 2016 Page 1 of 6

Test Report No. AJHL FB Date: APR.06, 2016 Page 1 of 5

Test Report No. AJHL FB-2 Date: OCT.24, 2016 Page 1 of 6

Test Report NO. AJHL FB Date: JUN.21, 2016 Page 1 of 6

TEST REPORT No. : SHCCM Date : May. 17, 2013 Page: 1 of 5

TEST REPORT No. : SHCCM Date : Mar. 12, 2013 Page: 1 of 5

TEST REPORT Reference No. : TRHZ _R1 Date : Nov. 27, 2012 Page No.: 1 of 5

Test report No

Test report No

European B1 Fire Rating. soft collection softwall + softblock Fire Retardant (FR) Treated textile products. molo design, ltd

Test report No

Germany B1 Fire Rating. kraft paper products. molo design, ltd Venables Street Vancouver, B.C. Canada V5L 2G7

Test report No

Test report No

Test Report No.: SDHGR FM Date: Jun.08, 2012 Page 1 of 3

Test report no

Test certificate General construction inspection test certificate Nr. 3666/4421 -a - Fe/Wi 1. Issue ( )

TESTING LABORATORY FOR CIVIL ENGINEERING MATERIALS

Test Report No.: AJHL FT Date: JUN.02, 2016 Page 1 of 5

Test Report No.: SZTY TS Date: DEC 04, 2012 Page 1 of 10

FIRE REGULATION IN FURNITURE WORLD OVERVIEW

FIRE TEST REPORT FH 5078

FIRE TEST REPORT FH 5728

FIRE TEST REPORT FH 5154

TEST REPORT UL Fire test for Heat and Visible Smoke Release for Discrete Products and Their Accessories Installed in Air-Handling Spaces

Test report No

Test Report No.: AJD Date: NOV.05, 2013 Page: 1 of 5

Test Report. CHTC JIAHUA NONWOVEN CO.,LTD No.99,WaGou New Village, Pengchang,Xiantao,Hubei, CHINA

REPORT NUMBER: MID-001 ORIGINAL ISSUE DATE: Sept 27, 2013 REVISED DATE: NA

Test Report No.: SHHG BC Date: JAN.31,2013 Page: 1 of 12

Test report no

Test Report No.: SDHL FT Date: Jun.15, 2017 Page 1 of 5

Technical Specification for 12kV and 24kV Powder Filled Current Limiting Fuse Links for Use in Switchgear (In Air)

MIRTA-KONTROL d.o.o. LABORATORY DEPARTMENT

Test Report No.: SDHL FT Date: May 15, 2017 Page 1 of 15

Technical Specification for 12kV Powder Filled Current Limiting Fuse-Links for Use in Switchgear (In Oil)

National Standard of People s Republic of China

Test report no

Determination Of Fire Effluents From Products On Railway Vehicles

MITRAS MATERIALS GMBH

BS EN :2006. Windows and doors Product standard, performance characteristics. A Report To: Mila Hardware Ltd. Document Reference:

PRODUCT EVALUATION REPORT

VAUTH ANALYSING. TESTING. CERTIFYING. aviation components

The Furniture Retail Quality Group Best Practice Guide

Title: WF Report No: Prepared for: Simonswerk UK Ltd. Burcott Works, Spring Street, Tipton, West Midlands, DY4 8TF. Date: 20 th April 2012

Title: Fire Resistance Test In Accordance With BS EN : 1999 On A Glazed Screen Assembly. WF Report No: , Issue 2. Prepared for: Date:

Technical Specification for 12kV and 24kV Powder Filled Fuse-Links and Fuse Holders

Technical Specification for 12kV and 24kV Current Limiting Fuse- Links for Overhead Applications

Test Report No.: SHHG MD Date: FEB. 26, 2016 Page: 1 of 17

Oxygen Bomb Calorimeter

TNO report. Centre for Fire Research Van Mourik Broekmanweg 6 P.O. Box AA Delft. T F

TERMINATION TECHNOLOGIES FOR HAZARDOUS AREAS A practical guide

Cast Resin Transformers

SFI SPECIFICATION 3.3 EFFECTIVE: AUGUST 26, 2016 *

Classification report No K1

Urban Wildfire Interface: Exterior Wall Wildfire Testing

INTERNATIONAL STANDARD. Download aus SNV-Livelink, Schweiz. Normen-Vereinigung SNV. Max Peter

Physical Scaling of Water Mist Protection of 260-m 3 Machinery Enclosure

Test Report. No. SHAHG A01 Date: 10 May Page 1 of 6.

Durable Goods Labelling Compliance

WF Report No: Prepared for: Rohden UK Ltd Unit 2, Hayleys Manor Farm Upland Road, Epping Upland, Essex, CM16 6PQ. Date: Notified Body No:

NFPA 286 STANDARD METHODS OF FIRE TESTS FOR EVALUATING CONTRIBUTION OF WALL AND CEILING INTERIOR FINISH TO ROOM FIRE GROWTH

Verification/Report Number(s): HEARTWAY MEDICAL PRODUCTS Co., Ltd. Applicant Name/Address:

A Case Study: Review of Flammability Product Testing, the Similarities and Differences Ellen Roaldi Bureau Veritas Consumer Products Services

ASTM E 1354 Caloric Content Determination of "3M Polyurethane Adhesive Sealant 540"

IECEx Certificate of Conformity

ADDRESS : 5/F., NO NAIYAN RD, JIAOJIANG, TAIZHOU, ZHEJIANG, CHINA. TURN AROUND TIME : 19-Jun-2012 to 25-Jun-2012, 4 working days

EU Mutual Recognition Technical Requirements

IECEx Certificate of Conformity

TEST REPORT Report No.: HCO0127/2006 Page: 1 of 9 Date: November 1, 2006

SGS TEST REPORT. Page: 1 of 6 Date: April 20, itech Company LLC Christy Street, Fremont CA USA

NFPA 285 TEST REPORT. Report No.: H Test Date: June 1, Rendered to: ARCONIC ARCHITECTURAL PRODUCTS Eastman, Georgia

:... Test accortling to. ISO 4589 Part 2 : Client: Am Stadthafen Gelsenkirchen

Report No: Test of: Reversible aluminium/timber window. Tested to: BS :2009 Performance of windows & doors Part 2: Operation & strength

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

InnoBYG small scale demonstration tests - Part 2

Every manufacturer of an agricultural tractor shall meet the following requirements for the tractor model before granting the type approval.

Test Report. No. SHAHG Date: 07 Nov Page 1 of 9.

SFI SPECIFICATION 3.2A EFFECTIVE: APRIL 20, 2018 *

Laboratory Report. U. S. Department of Justice

Full extension concealed slide with soft closing and self-closing

ST/SG/AC.10/C.3/2017/3. Secretariat. United Nations. Stability tests for industrial nitrocellulose. Introduction

Comparison of Styropor and Neopor Expanded Polystyrene Foam Insulations HAI Project No. 1JJB

Test Report. No. SHAHG Date: 11 Nov Page 1 of 7.

Roofing Tests for European Roofing Products ENV 1187 Test 1, 2, 3 and 4

APPLICATION FOR CONSTRUCTION PRODUCTS DIRECTIVE. On Behalf of Shenzhen Changen Industry Co.,Ltd. 2 interactive pins 5 color cylinder.

ETHANOL 1100 FIREPLACE OWNER S MANUAL

Page 3 of 34 Report No Part I

PART X SUB PART (B): DETAILS OF STANDARDS OF VISIBLE AND GASEOUS POLLUTANTS FROM DIESEL ENGINES FOR CONSTRUCTION EQUIPMENT VEHICLES

THERMAL SHOCK TEST REPORT

Ignition Temperatures of R1234yf

Technical Specification

Report Number BTC 12024F

Title: Fire resistance test in accordance with BS EN : 2008 on an uninsulated, face fixed rolling shutter doorset. Report No: Prepared for:

DETAIL SPECIFICATION SHEET INSULATION SLEEVING, ELECTRICAL, HEAT SHRINKABLE, POLYOLEFIN, FLEXIBLE, CROSSLINKED

Hazardous areas, as found around a service station, are classified into three zones as follow: Table 1: Zone Classification for Vapours

CERTIFICATE of QUALITY TEST

Precision engineered to the highest Australian Standards, you ll find Ardent copper fittings and coils for just about every application. Ardent.

13 th December Title: The Fire Resistance Performance Of Doorsets When Fitted With Perko Powermatic R100 Jamb Mounted Concealed Door Closers

NovitaTech Engineering

Transcription:

Test Report No. AJHL1609010810FB Date: OCT.26, 2016 Page 1 of 6 SOYANG TECHNICAL TEXTILE (ZHEJIANG) CO., LTD NO.36 JINNIU ROAD, JIANSHAN DISTRICT, HAINING CITY, ZHEJIANG PR., CHINA The following sample(s) was / were submitted and identified on behalf of the client as: Sample Description: TERRIFIC STRETCH FABRIC Style/Item No.: ST-142 Supplier: SOYANG TECHNICAL TEXTILE (ZHEJIANG) CO., LTD Manufacturer: SOYANG TECHNICAL TEXTILE (ZHEJIANG) CO., LTD Test Requested: To determine the flammability (building materials class B1) in accordance with DIN 4102-1 (May 1998) Fire behaviour of building materials and elements Part 1: Classification of building materials, Requirements and testing Test Results: -- See attached sheet Classification: The tested sample meets class B1 building materials requirements of DIN 4102-1 (May 1998). Test Period: Sample Receiving Date : OCT.08, 2016 Test Performing Date : OCT.08, 2016 TO OCT.24, 2016 Signed for and on behalf of SGS-CSTC Co., Ltd. Anji Branch Allen Zou Technical Manager

Test Report No. AJHL1609010810FB Date: OCT.26, 2016 Page 2 of 6 I. Test conducted This test was conducted as per DIN 4102-15:1990 DIN 4102-16:1998 and DIN 4102-1:1998 Clause 6.2, and Classification in according to DIN 4102-1 (May 1998) Clause 6.1-Class B1 materials. II. Sample details General description / Color TERRIFIC STRETCH FABRIC / White Density About 250 g/m 2 Size of sample 1000mm 190mm & 190mm 90mm Conditioning Prior to testing, the sample was conditioned at least 14 days to constant mass at a temperature of 23 ± 2 C, and a relative humidity of 50 ± 6 %. III. Test results 1) Brandschacht Test according to DIN 4102-15 &16 Exposed surface: The front face Line No. 1 Results of Brandschacht Test (part 1) Specimen fixings according to DIN 4102 part 15, table Unit Test assemblies No. Widthwise / / / 2 Max. flame height above lower sample edge; cm 40 40 3 Time 1) min:s 0:10 0:08 Melting/burning through 4 Time 1) min:s 0:03 0:04 Back of specimen 5 Flaming/glowing, Time 1) min:s 0:05 0:07 6 Discolouring, Time 1) min:s 0:02 0:02 Burning droplets / / 7 Begin 1) min:s 0:18 0:21 Amount / / 8 Specimen material falling off in separate droplets 9 Specimen material falling off continuously / /

Line No. Test Report No. AJHL1609010810FB Date: OCT.26, 2016 Page 3 of 6 Results of Brandschacht Test (part 2) Unit Test assemblies No. Widthwise Burning parts No No 10 Begin 1) min:s / / 11 Parts of sample falling off separately / / 12 Parts of sample falling off continuously / / 13 Duration of continued combustion on mesh base (max.) Burner flame impairment by dripping/falling material min:s No No 14 Time 1) min:s / / Premature ending of test / / 15 End of burning at specimen 1) min:s / / 16 Time when test terminated (if applicable) 1) min:s / / Burning after end of test No No 17 Duration min:s / / 18 Number of specimens / / 19 Front of specimen / / 20 Back of specimen / / 21 Height of flame cm / / Glowing after end of test No No 22 Duration min:s / / 23 Number of specimens / / 24 Front of specimen / / 25 Back of specimen / / 26 Top half of specimen / / 27 Bottom half of specimen / / No No

Test Report No. AJHL1609010810FB Date: OCT.26, 2016 Page 4 of 6 Results of Brandschacht Test (part 3) Line No. Unit Test assemblies No. Widthwise Residual length 28 Single results cm 68 62 68 66 65 70 62 65 29 Average of the single results cm 66.3 65.3 Smoke temperature 30 Max. of average 131.8 129.7 31 Time 1) min:s 06:56 07:02 Note: 1) time from start of testing *Reduction in number of test (DIN 4102 Part 16, clause 5.2) Class B1 materials: If the residual length measured after the first test is 45cm or greater, further tests are not required. 2) Normal Flammability Test according to DIN 4102-1 Clause 6.2 Flame application: [ ] bottom edge ignition, [ ] surface ignition Parameter Reaching the measuring mark within 20 seconds(yes/no) Crosswise 1 2 3 4 5 6 7 8 9 10 No No No No No No No No No No Self extinguishing of the flame (s) 15 15 15 15 15 15 15 15 15 15 Max. flame height (cm) 2 1 2 2 3 3 4 3 4 4 End of afterflaming (s) 15 15 15 15 15 15 15 15 15 15 End of afterglowing (s) 15 15 15 15 15 15 15 15 15 15 Molten dripping(yes/no) No No No No No No No No No No Smoke developments (visual impression) All timings are from start of testing. Slight Slight

Test Report No. AJHL1609010810FB Date: OCT.26, 2016 Page 5 of 6 IV. DIN 4102-1:1998 Criteria for classification 1) All materials, except flooring, may be classed as B1 materials if they meet the following requirements a) and b): a) The test using the Brandschacht apparatus described in DIN 4102-15 (cf. subclause 6.1.3.1) shall be deemed passed if The mean value for the residual length (portion of specimen that has not burned or charred; cf. subclause 9.1 of DIN 4102-16) of each specimen is at least 15 cm and no individual values are lower than 0 cm, The mean effluent temperature does not exceed 200 C in any test, The requirement for the residual length of each specimen is met even where there is afterflame, afterglow, or smouldering. b) Pass DIN 4102-1: 1998 sub-clause 6.2.3 Ignitability Test if For each specimen, flaming doesn t reach the gage mark within 20s after flame application. 2) Materials may be classed as B2 materials if they pass the ignitibility test specified in DIN 4102-1: 1998 subclause 6.2.5. For each specimen, flaming doesn t reach the gage mark (150mm marks) within 20s after flame application. 3) Combustible materials which cannot be classed as B1 or B2 materials shall be classed as B3 materials. STATEMENTS: This test report does not replace any mandatory certification of the product that may be required. The test results relate to the behaviour of the test specimens of a product under the particular conditions of the test; they are not intended to be the sole criterion for assessing the potential fire and smoke hazard of the product in use.

Test Report No. AJHL1609010810FB Date: OCT.26, 2016 Page 6 of 6 Photo Appendix: SGS authenticate the photo on original report only *** End of Report ***