VISO Reference CALI-T50. User guide

Similar documents
USP s. 30 mm BEND RADIUS

KLED18STD. Product Overview. 18w LED DD Standard, 30000hrs

ELD DRIVER GUIDE June 21, 2018

Dreamer Series. LED bulb A60. Product benefits. Product features. Product datasheet

Adam Equipment DUNE DCT SERIES. (P.N. 9384, Revision B2, June 2013)

User's Guide. Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer. Introduction

Compact Scales. Software Revision V1.25 & above

362 Clamp Meter. Users Manual

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Instruction Manual Installation and Operation Guidelines for DWL5000XY and DWL5500XY Tilt Sensor Modules (Version 2.2)

MANUAL BAT/48342 IMPORTANT NOTE : BEFORE FIRST USE CHARGE THE JUMP STARTER WITH THE SUPPLIED CHARGER FOR AT LEAST 12 HOURS.

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Photometric Test Report

Digital Torque Wrench

233 True-rms Remote Display Digital Multimeter Safety Information

ECO Spot 2500 User Manual

ECO Spot 2500 User Manual

LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL LED Luminaires

Go to to register your product and find more information.

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Soraa Internal Report: IES LM79 08

Soraa Internal Report: IES LM79-08

Switching DC Power Supply

SI AT A22. English. Printed: Doc-Nr: PUB / / 000 / 01

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Model P772 Conductivity Meter. User Manual

Megohmmeter Test Probe

DC Master 24/ A

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Adjustable Adjustable Large Adjustable Deep. Deep / Deep IP44 / Deep Adjustable Deep Gold Deep Black Gold. IP44 Square Square Adjustable / 1-2-3

LED.Commercial 12W LED DD

Light & Motion. Urban 180, 300, & 500 Instruction Manual

LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL LED Luminaires

LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL LED Luminaires

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013.

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013.

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013.

LIGHT EFFICIENT DESIGN

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013.

SI AT A22. English. Printed: Doc-Nr: PUB / / 000 / 03

Contents Getting Started with PrePass ELD...4 Starting a Trip...7 During a Trip Co-Driver Features... 14

StarEye. 350 ma version. No control electronics on board

NVLAP LAB CODE LM Test Report. For. MaxLite Inc. (Brand Name: MaxLite) 12 York AveWest Caldwell NJ 07006

LED HANDHELD SLIT LAMP

Car Battery Charger Instructions for Use

Tester for Motor-Driven Relays Type Siemens SICO 1225 M A N U A L

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: N/A) 12 York Ave, West Caldwell, NJ 07006

LIGHT EFFICIENT DESIGN, LLC

EchoPod. UG06 & UG12 Series Quick Start Flowline, Inc. All Rights Reserved Made in USA. Ultrasonic Liquid Level Transmitter

BT508/BT510/BT520/BT521 Battery Analyzer Safety Sheet

NVLAP LAB CODE LM Test Report For. Model Different: All construction and rating are the same, except CCT

first issue : last change : MSD Platinum 15 R number of pages : 12 LE 2166

PRODUCT DESCRIPTION TECHNICAL DATA. Dimmable 0.1% - 100% Operating temperature - 30 C +45 C LED per meter 60 Pitch distance Cutting Length (C)

CONTENT 1 PICTURE GENERAL... 3

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

USER GUIDE 1 USER GUIDE

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

PAR38 Waterproof IP65

51 & 52 Series II. Users Manual. Thermometer. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

Wet Locations Use. RoHS. Model: VAC / 28 W PF LM 93 LM/W. Alluminium + Tempered Glass 24-45VDC 0.

Genesys 20 Calibration and Maintenance

Instruction Manual for Globe Price Computing Scale Models GS30 and GS30T

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

Issue 2.0 December EPAS Midi User Manual EPAS35

NVLAP LAB CODE LM Test Report. For. MLS CO., LTD (Brand Name: MLS) NO.1 MULINSEN RD XIAOLAN TOWNSHIP ZHONGSHAN, GUANGDONG CHINA

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

EPAS Desktop Pro Software User Manual

Instruction Manual. H.I.D Digital Ballasts 400W 600W 1000W. All our ballasts are compatible with Safe Grow Hydroponic Smart System.

Uponor TechCON TD 7.0. User manual Smart and easy planning of underfloor heating

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

User manual Temperature Calibrator JOFRA CTC-140/320/650 A/B JOFRA CTC-1200 A Copyright 2005 AMETEK DENMARK A/S ( UK)

MAINTENANCE SPECIFICATIONS LEGISLATION WARRANTY

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

Getting Started HONDA

LUMILUX T5 HO CONSTANT

NVLAP LAB CODE LM Test Report. For. MaxLite lnc. (Brand Name: MaxLED) 12 York Ave West Caldwell NJ 07006,USA

Important notice Upper supports for Z axis Pulley Corner for Y axis Right X axis and left X axis Chain coupling for left X axis

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

OWNER'S MANUAL AIR MOTION

MADMax Moisture and Density Interface: Quick Start Guide

How to get started. with. Kongsberg XP Auto systems. Serial number: Please Read This First

Osram Sylvania 200 Ballardvale Street Wilmington, Mass

INDEX. 1.Safety Precautions and Warnings...3

Inazuma Installation and Operating Instructions INAZUMA HD PRO UV-C. High-Performence Duo UVC Lamp

NANOPAC-300 & 500 Power Supply. Instruction manual NANOPAC-300 & NANOPAC-500

TL 700. Instruction Manual (Read before use!)

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDUCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)

Active Controlled Cooling System

323/324/325 Clamp Meter

BRAKE TESTER DECELEROMETER

Index 2. Content 2. Technical 3. Specifications 3. Installation 4

NVLAP LAB CODE LM Test Report. For REMPHOS TECHNOLOGIES LLC. (Brand Name: ) 90 Holten St, Danvers, MA 01923,USA.

EN. SKF Grease Spraying System For Large Open Gears. Extend the lifetime of large gear drives

NVLAP LAB CODE LM Test Report. For IGT LIGHTING INC Lincoln St. Suite B, Riverside, CA 92503

1000mA - 650mA Phase Dimmable LED Driver

User Manual. Solar Charge Controller 3KW

User Instruction Manual Oxford Classic Digital Weigh Scale. To avoid injury, read user manual prior to use.

Transcription:

VISO Reference CALI-T50 User guide Last edited 9 June 2017

Content Safety information... 3 Introduction... 4 Shipping Packages... 5 Contents... 6 Aligning the sensor... 7 Measuring distance... 8 Connect power... 8 Make reference measurement... 9 Calibrating sensor... 10 Download fixture file or PDF... 10 LabSensor calibration... 12 LightSpion Calibration... 14 Cali T50 User Manual 2

Safety information Warning! This product is not for household use. Read this manual before installing and operating the Cali T50, follow the safety warnings listed below, and study all the cautions in the manual. Preventing electric shocks Make sure the power supply is always grounded. Use a source of AC power that complies with the local building and electrical codes, that has both overload and ground-fault protection. If the controller or the power supply are in any way damaged, defective, wet, or show signs of overheating, disconnect the power supply from the AC power and contact Viso Service for assistance. Do not install or use the device outdoors. Do not spray with or immerse in water or any other liquid. Do not remove any covers or attempt to repair the controller or the power supply. Refer any service to Viso. Disposing of this product Viso products are supplied in compliance with Directive 2002/96/EC of the European Parliament and of the Council of the European Union on WEEE (Waste Electrical and Electronic Equipment), as amended by Directive 2003/108/EC, where applicable. Help preserve the environment! Ensure that this product is recycled at the end of its lifetime. Your supplier can give details of local arrangements for the disposal of Viso products. Cali T50 User Manual 3

Introduction About this document These guidelines describes how to use the Cali T50 as a reference light source and how to do custom calibrations on Viso Systems goniometer products. About the Cali T50 The CALI-T50 is and irradiance reference lamp which means it is a directional lamp with intensity and spectra defined in one point in front of the lamp as shown below.. 75 90 60 45 30 15 0 15 30 45 60 75 90 Intensity in candela, Color temperature, CRI and spectral distribution is 2007 Viso Systems ApS, Denmark All rights reserved. No part of this manual may be reproduced, in any form or by any means, without permission in writing from Viso Systems ApS, Denmark. Information subject to change without notice. Viso Systems ApS and all affiliated companies disclaim liability for any injury, damage, direct or indirect loss, consequential or economic loss or any other loss occasioned by the use of, inability to use or reliance on the information contained in this manual. Cali T50 User Manual 4

Dimensions Shipping Packages Shipping packages Shipping dimensions Weight 1. Cali T50 40 x 30 x 25 cm 2 Kg Total shipping weight: 2 kg. The shipment is done in 1 package. Cali T50 User Manual 5

Contents The Viso reference lamp is delivered in a smart suitcase along with two cables. The CALI-T50 comes with a certificate as shown below. Light efficiency: Light quality: Color temperature: Beam angle 75 90 60 CRI of the CALI-T50 CRI: 99,8 2869 K Color temperature of the CALI-T50 45 30 15 0 15 Output: 0,000 lm Peak: 715 cd Power: 56,4 W PF: 0,57 30 45 Serial number of 60 sensor used to Intensity in candela of the CALI-T50 Serial number of the CALI-T50 Product name: Ref LAB 16101102 Date and time: 13-02-2017 12:58:02 75 Additional information: measure CALI-T50 For sensor 0712586340 90 Sensor distance of 200,1 cm 105 105 120 135 150 165 180 165 120 135 150 Measurement distance used to measure the CALI-T50 Color CIE1931 x: 0,447 y: 0,408 Spectral power distribution of the CALI-T50 Spectra Power Voltage: 231 V Current: 0,427 A 400 450 500 550 600 650 700 750 800 Light measurement was created using the Viso Systems - Light Inspector. www.visosystems.com Cali T50 User Manual 6

Aligning the sensor The very first step is to mount the reference lamp into the setup as shown in the pictures. Then place the sensor approximately two meters away (recommended to use approximate same distance as defined on certificate) from the setup with the reference lamp. Make sure the sensor is aligned with the lamp. Shoot the laser towards the lamp glass and catch the reflected beam in the same area of its origin, or within a 4 cm area. Such a procedure puts both the sensor and the lamp in alignment. The pictures below explain the process: Incorrect alignment Ok alignment Cali T50 User Manual 7

Measuring distance When the sensor is aligned relative to the lamp, you can measure the precise distance between the two components. It should be between 190 and 210 cm (refering to the certificate). Activate the by pressing the Laser on button on the back of the sensor and target the laser beam towards the little white point above the lamp area and press the Measure distance as shown below. The glass surface of the lamp produces a lot of internal reflections of the laser beam, and it complicates the exact distance calculation. The precise distance determination is essential in achieving the best results. That is why a fixed white target point was designed above the lamp luminous area. After the distance has been measured to the point the laser back to the centre of the glass. Connect power To turn on the lamp simply plug in the lamp to the box socket, and then connect the box to the power supply, as shown in the pictures below. The lamp needs to ramp up, and there is an indicator with a mini instruction on the box. The blue flashing indicator means the lamp is ramping up, a constant blue colour defines the lamp is ramped up, whereas the red colour of the indicator means there is an error. Then the lamp needs to stabilise for at least 30 minutes, after which it is ready for measurement. Cali T50 User Manual 8

Make reference measurement The most typical is to make a reference measurement where you simply test the if the measured data matches the certificate to verify that sensors calibration is intact. When the lamp is warmed up simply turn on the spectrometer by clicking on the spectra icon. If the spectra is over saturated just click on the red oversaturation label to get the system readjust the spectrometer to remove the saturation. The CALI-T50 is an irradiance lamp and does not have a lumen value but only candela and photometric values at one point, so you cannot make a complete measurement where the lamp is moved. Just turn on the spectrometer and check if the live values matches those of the certificate that came with the Viso Cali T50. To save a live measurement, simply click the save button and save it to the log. Remember, most likely there will be some fluctuation in values and accuracy which can be seen below. Candela accuracy +/- 4% (including sensor) for example for 700 cd (672-728) Color temperature accuracy +/- 35K Check the spectra is relative smooth as on the certificate. GOOD BUMBY Cali T50 User Manual 9

Calibrating sensor The main purpose of the CALI-T50 is to check if your calibration is intact, as CALI-T50 was measured using your sensor before the sensor was shipped. But the CALI-T50 can also be used to re-calibrate your sensor. All the Viso products has two memory areas where calibration data can be stored. The first memory area contains the factory calibration and cannot be edited. But second area contains the custom calibration and can be changed by the user as many times as desired. Before a calibration can be made you must have a lamp file (.lmp) for the CALI-T50 lamp. This lamp file is normally not included with the CALI-T50 but by sending an email to Viso with the serial number can you get the file. The lamp file specifies the CALI-T50 in uw/cm2/nm at 0.5m for each wavelength, making it possible to make a full spectral and intensity calibration of the sensor. Download fixture file or PDF To do a calibration it is necessary to use the correct fixture file for the Viso Cali. After the Cali T50 has been measured by Viso Systems, all the data are uploaded to our server, so it is always available to download. To download the fixture file or report, go to: Visosystems.com Support Reference lamp database Serial number: 15010705 Cali T50 User Manual 10

Type in the serial number from the Cali T50 case or lamp, in the reference lamp database and press submit. When your lamp is found you can download the.fixture file by pressing the link. Here you also find the certificate document in pdf for the Cali T50 Cali T50 User Manual 11

LabSensor calibration ATT Before recalibrating the LabSensor the CALI-T50 must be aligned, distance measured and warmed up as described in previous chapters, and make sure you have you lamp file ready (.lmp) Follow the 5 steps to make a correct calibration: Step 1. Open the Viso Light Inspector software connected to the LabSpion via USB and select Setup -> Spectrometer calibration. Then select custom calibration and click on the new button. Note: The primary factory calibration will not be lost, and you can always return it. Step 2. Select Load lamp file to load the calibration source spectrum. The system will automatically calculate the intensity of the source in candela based on the lamp file at a distance of 0.5m. If the measurements are done at a different distance, then click on the recalculate button. If you don t know the lamp distance but know the intensity value in candela simply insert it directly into the candela box. Step 3. Make sure the calibration source has been turned on for at least 30 min so the output is stable. Step 4. Click next and set the integration time to a maximum possible value to ensure the highest resolution and thereby the best calibration quality. Click next. Cali T50 User Manual 12

Step 5. To make a dark measurement cover the sensor or turn off the calibration source so the dark reference spectra can be measured. Click next and the calibration is finished. When you close the calibration dialog you will be asked if you want to save the calibration to the device. When selecting yes the custom calibration will be saved inside the device. You can always switch back to the factory calibration at any time. Restart the Viso Light Inspector software and check the new calibration is stored correctly by going into Setup-Calibration. Cali T50 User Manual 13

LightSpion Calibration The LightSpion is delivered pre-calibrated but it is possible to make a custom calibration of the photo spectrometer if desired. This could be necessary if the LightSpion is to be certified by an official agency, which will perform its own calibration and afterwards issue certification documents. To make a custom calibration a calibration source must be used, the spectrum of which in a directional point at a certain distance is known. Such a spectrum is usually specified as power in uw/cm2/nm, as shown below. Calibration sources can be obtained from a number of suppliers, in this example will we use the CALI-T50 from Viso Systems which is a tungsten irradiance lamp. The spectrum of the calibration source is usually provided in a.lmp file (lamp file). NOTE! Making a custom calibration does not delete the Viso factory calibration. You can always switch between factory and custom calibration at any time.these steps shows how to make a custom calibration. IMPORTANT: Calibration must be made in a dark environment, with non-reflective surfaces. Step 1. Place the calibration lamp at the centre of the rotation motor and make sure it is lifted to the right height by using the alignment tool. The lamp must be pointed directly towards the sensor. Sometime is might be necessary to unplug RJ45 cable to the motor to enabling precise alignment. Cali T50 User Manual 14

Step 2. Open the Viso Light Inspector software connected to the LightSpion via USB and select Setup -> Spectrometer calibration. Then select custom calibration and click on the new button. Note: The primary factory calibration will not be lost, and you can always return it. Step 3. Select Load lamp file to load the calibration source spectrum. The system will automatically calculate the intensity of the source in candela based on the lamp file at a distance of 0.5m. If the measurements are done at a different distance, then click on the re-calculate button. If you don t know the lamp distance but know the intensity value in candela, simply insert it directly into the candela box. Step 4. Make sure the calibration source has been turned on for at least 30 min, so the output is stable. Cali T50 User Manual 15

Step 5. Click next and set the integration time to a maximum possible value to ensure the highest resolution, and thereby the best calibration quality. Step 6. Click next and cover the sensor or turn off the calibration source, so the dark reference spectra can be measured and click next and the calibration is then finished. When you close the calibration dialog will you be asked if you want to save the calibration to the device. When selecting yes the custom calibration will be saved inside the device. You can switch back to the factory calibration at any time. Restart the Viso Light Inspector software and check the new calibration is stored correctly by going into Setup->Calibration. Cali T50 User Manual 16