Cavity Stop Socks & TCBs

Similar documents
RockLap H&V Pipe Sections

Flexible insulation to prevent condensation and energy losses

Circular Silencer. Rigid and flexible construction Type CA CB CF CS. TROX GmbH Telephone +49/28 45/ Telefax +49/28 45/

Spaceloft Insulation TECHNICAL GUIDE

Designed to prevent condensation and energy losses

Product Data Sheet. KS1100QCK Longspan. Applications

Environmental Product Declaration

Polycarbonate Multi-wall Glazing. July 2009

Circular silencers. Type CS. For the reduction of noise in circular ducts, aluminium construction PD CS 1. 02/2017 DE/en

Circular silencers. Type CA. For the reduction of noise in circular ducts, galvanised sheet steel construction. 02/2017 DE/en PD CA 1

polylam vertical baffle system Product data sheet durlum.us Your contact for North America

Polycarbonate Multiwall Glazing. September 2011

U Thermo datasheets May Manufactured in Springs according to ISO 9001 : 2008 South Africa

DECLARATION OF PERFORMANCE

Type CS FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, ALUMINIUM CONSTRUCTION

The highest possible standards. The best possible solutions.

Downlighters and fire safety

Infrastructure & Power. FP M c Cann. Tel: +44(0) Fax: +44(0)

Environmental Product Declaration

3 Panel Horizontal Sliders C03: Centre Opener

KVA POWERHOUSE RANGE 1250 KVA 1700 KVA

BOX BLB Centrifugal Box Fan

Product Benefits. COMPARATIVE WEIGHTS OF GLAZING MATERIALS kg/m 2. RELATIVE U-VALUES W/m 2 K. *16mm Triplewall with 20mm and 16mm rib spacing

FireFree ScandiBoard 850 Passive Fire Protection of Steel Constructions R30 - R180

FREEZSTOP MICRO SYSTEM

FDR - Fire Damper for Rectangular and Circular Ducts. Halton FDR. Fire Damper for Rectangular and Circular Ducts

RUBBER BELLOWS TYPE 1A & 1S SERIES

3.2 Spring diameter to height ratios are designed to ensure that spring will never buckle even when fully loaded.

Declaration of Performance

FIRE DAMPERS, FIRE PROTECTION VALVES, SMOKE DAMPERS

Type MSA. Splitter thickness 200 mm FOR INCREASED INSERTION LOSS AND BROADBAND ATTENUATION EVEN IN THE LOW FREQUENCY RANGE

Mixed Flow Roof Fans (RMH)

KAIFLEX PRODUCT BROCHURE

Environmental Product Declaration

Guangzhou Stadium Project TRADITIONAL

ARMASOUND INDUSTRIAL SYSTEMS THE FIRST SOUND CONTROL SYSTEMS TO MINIMISE THE RISK OF CORROSION UNDER INSULATION (CUI)

EN 1154:1997 / A1:2002

Heradesign fine Product Data & Certificates

Bulletin Wiring methods for Solar Photovoltaic Systems Rules, 2-034, , and , Tables 11 and 19

INT Multipoint Range. Tindall Engineering Limited is registered in England and Wales - Company Number

Inclined Platform Lifts SUPRA & SUPRA LINEA

MCCAIN FOODS (AUST) PTY LTD

CONTENTS. Ordering Information... Page 3. Cardrona, Monaco, Geneva, Vienna... Page 4 Offset & Extension Kits For Freestanding Fires...

High Performance Axial Fans

Uniclass L325:P4142 EPIC F631:X442. Cl/Sfb (31.9) Hh2. February Lintels. Trade price list. Effective 1 st February 2018

EWC-PC POWER CENTER FOR LOW VOLTAGE POWER DISTRIBUTION UP TO 6300A POWER CENTER

Vertical Balanced Flue Kit All Internal Grant Boilers

Mixed Flow Roof Fans (RMH)

Accessories Performance Standards Manual. Version 1 24/12/

HIGH CAPACITY POWER VENT KIT

Polycarbonate Multiwall Glazing

WIRES & WIRING CABLES

Radial roof fans - SMART-UL. Application. Stylistics. Structure. Efficiency adjustment. Acoustics

Bevent Rasch BSK Fire /04/2017

CYCLONE F 400 smoke extraction casing

NOVENCO FAN CATALOGUE

Direct Vent Top Exit Vertical Flue Kit

Stradaflair. Strada Trench Convectors. Strada Flat Panel Range. Strada Radiant Skirting. Strada Heated & Chilled Ceilings. Strada Electrical Products

Evidence of Performance Airborne sound insulation of flat roofs

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

EXTERNAL SCREEN CLASSIC SATINÉ 5500

Bevent Rasch BSK6. - Fire /04/2017

1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide

PVHRU Max Quiet. Engineering Solutions. Packaged Void Heat Reclaim Unit. Acoustic Testing Laboratory College of Science & Technology

Crastin PBT Thermoplastic polyester resins

SCREEN VISION. SCREEN VISION SV 1 % -3 % -5 % - 10 % INTELLIGENT FABRICS FOR SOLAR PROTECTION INTERNAL APPLICATION

More than lifts worldwide with GMV technology HOME LIFTY MRL.

Fire/smoke damper EKO-SRBG1

Insulation Colours: Orange (Standard) Natural Natural. Sheath Colours: Orange (Standard) Orange (Standard) Bedding: Black

LPCB LPS 1175 APPROVED PRODUCTS

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

THE PRE-INSULATED COPPER PIPES FOR DURABLE AND EASY CONNECTION OF AIR CONDITIONING UNITS

PRINETO Price List Prineto

Heradesign superfine Product Data & Certificates

PLAY AREA SAFETY INSPECTION REPORT

CERTIFICATE OF APPROVAL No CF 209 ROYDE & TUCKER LIMITED

Mufflers. Absorptive, Reactive, Reactive Lined, Reactive Side Entry, Reactive Side Entry Lined

VEHICLE AND PEDESTRIAN CONTROL

Sarnafil TS E. Polymeric membrane for roof waterproofing. Product Description

NEW: quality. DuoSolar. DuoSolar. ARMAFLEX DUOSOLAR the easy-to-install pre-insulated tubing system for reducing the energy loss.

VERSO-CF H-PM/IE5/2/2-F7-M5-HW/4R/2.6-X-R1-C5.1-X

ISO 3934 INTERNATIONAL STANDARD

NEW AND EXTREME HIGH QUALITY CABLE GUARDS RED LINE USE WITH HIGH VOLUME VEHICULAR TRAFFIC

EXPLOSION PROOF. Diesel Engines For Hazardous Areas

DIN EN General

Mining and Petrochemical Tray-Rated Fiber Optic Cables

CLASSIC, CONTEMPORARY

UniPack compact secondary substations (CSS) upto 36 kv For safe, reliable and space saving power distribution solutions

TPM 075/09-DK VALID FROM: 15/1/2012 FIRE DAMPER AND FIRE DAMPER-SMOKE FDMB, FDMB-SRD

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

VARYCONTROL VAV Dual Duct Terminal Boxes

Slim profile steel system for doors and windows

Title: WF Report No: Prepared for: Simonswerk UK Ltd. Burcott Works, Spring Street, Tipton, West Midlands, DY4 8TF. Date: 20 th April 2012

Steel Spline Joint Bulkheads Junction: B-0 Class FIPRO MS 16 mm steel spline No x3 mm Construction: free-standing Sound reduction: 29 db (estima

Fire Block and Pressed Steel Grilles

SSDC overhead closer

600/1000V, PVC Insulated Cables according to IEC

ULTRA LOW ENERGY. VHR Void Series W/I/s TOTAL SFP Typical. Made in the UK. VHR Void Mounted Heat Recovery Units VHR PERFORMANCE OVERVIEW:

is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire.

Transcription:

MANAGEMENT V3 27.04.2015 Cavity Stop Socks & TCBs Key Features Up to four hours fire integrity Specified in semi-detached, apartments and major projects Complies to Robust Detail Part E and Building Regulations Available without flanges (CSS) or with flanges (TCB) Can be manufactured to suit cavity widths up to 300mm ARC Cavity Stop Socks and TCBs have been designed to restrict the spread of smoke and flames within external masonry and timber frame walls, and to further minimise the effect of flanking noise pollution at wall junctions. They are produced from low resin, non-combustible rockfibre mineral wool and are sleeved in 50 micron polythene for on-site weather protection. Installation ARC Cavity Stop Socks and TCBs are designed to be compression fitted within the cavity and are easily installed both vertically and horizontally during construction. Care should be taken to ensure butt joints are tightly fitted to maintain fire integrity. The cavity barrier must fully fill the cavity from the inner to outer leaf and any cavity insulation must be cut back. When using ARC TCBs for timber frame construction, the flanges are fixed to the frame using clout nails at 150mm centres. In vertical applications, both flanges are fixed, in horizontal applications only the top flange should be fixed. At door and window openings it is recommended the horizontal barrier should overlap the vertical barrier to ensure a close butted fit can be achieved. Fire Properties ARC Cavity Stop Socks and TCBs are manufactured using rockfibre mineral wool which achieves a fire classification of Euroclass A1 as defined in BS EN 13501-1. Don t take our word for it, see our accreditation... SYSTEMS Assessed to ISO 9001 & ISO 14001 BRE Certificate No. 1227 ARC Cavity Stop Socks and TCBs are tested at Warrington Fire Research and Chiltern International Fire, achieving up to four hours fire integrity with traditional masonry construction and up to one hour in a timber frame construction. These tests comply with BS 476: Part 20: 1987 and BSEN 1366-4: 2006, using the test method stated EGOLF TC2 N421 (fire resistance for cavity barriers). Warrington Fire Research certificate number: 169804 Chiltern International Fire certificate number: 10039

Thermal Properties ARC s rockfibre mineral wool insulation has a thermal conductivity of 0.037W/mK. Acoustic Properties The rockfibre mineral wool insulation used in the manufacture of ARC has the following acoustic absorption properties. Figures quoted were achieved with a solid backing. Party Wall Junction ARC s PWCSS and PWTCB fire barriers should be fitted with a minimum 50mm overlap with the party wall leaf either side of the party wall cavity. At 250mm wide, PWCSS and PWTCB will suit up to a 150mm party wall cavity. Thickness 125Hz 250Hz 500Hz 1000Hz 2000Hz 4000Hz 40mm 0.19 0.46 0.79 0.92 1.00 1.00 100mm 0.57 1.00 1.00 1.00 1.00 1.00 Part E Robust Details compliance: Separating Wall/ Party Wall Masonry E-WM 1-21 N/A Timber Frame E-WT 1-4 E-FT 1-6 Separating Floor Concrete N/A E-FC 1-14 Standards The rockfibre mineral wool used in the manufacture of ARC Cavity Stop Socks and TCBs conforms to BS EN 13162 and EN16001 Energy Management Systems. Storage and Packaging ARC Cavity Stop Socks and TCBs are supplied in polythene packs which are designed for transporting and protecting the products. It is not recommended that the packs are stored in direct sunlight as the polythene which encapsulates the barriers can be damaged. When storing the barriers for longer periods of time it is recommended the product should be stored indoors, or under cover. Environment Outer leaf Minimum 50mm overlap with party wall leaf Inner leaf Party wall cavity Party wall leaf No CFCs or HCFCs are involved in the manufacturing process of ARC s rockfibre mineral wool insulation. The material presents no known threat to the environment and is classed as ODP and GWP zero. ARC have a Green Guide rating of A+. Above: Cavity Stop Sock installed vertically in traditional masonry construction You might also be interested in... ARC T-Barrier System: Fire, Thermal and Acoustic Requirements at the Party Wall and Pitched Roof Above: TCB installed horizontally in timber frame construction

Dimensions & Packaging Specification: Cavity Stop Socks (No flange) Product Code Suitable for Cavity Width CSS Colour Masonry Fire Rating Dimensions Pieces per pack Packs per pallet CSS75 75mm Green 4 hrs 90 x 75 x 1200mm 35 12 CSS80 80mm Green 4 hrs 95 x 75 x 1200mm 35 12 CSS85 85mm Green 4 hrs 100 x 100 x 1200mm 24 10 CSS90 90mm Green 4 hrs 110 x 100 x 1200mm 20 10 CSS95 95mm Green 4 hrs 110 x 100 x 1200mm 20 10 CSS100 100mm Green 4 hrs 120 x 100 x 1200mm 20 10 CSS105 105mm Green 4 hrs 120 x 120 x 1200mm 15 10 CSS110 110mm Lt Blue 4 hrs 125 x 120 x 1200mm 15 10 CSS115 115mm Lt Blue 4 hrs 130 x 120 x 1200mm 15 10 CSS120 120mm Lt Blue 4 hrs 135 x 120 x 1200mm 15 10 CSS125 125mm Lt Blue 4 hrs 135 x 120 x 1200mm 15 10 CSS130 130mm Lt Blue 4 hrs 140 x 120 x 1200mm 15 10 CSS135 135mm Lt Blue 4 hrs 145 x 120 x 1200mm 15 10 CSS140 140mm Lt Blue 4 hrs 150 x 120 x 1200mm 15 10 CSS145 145mm Lt Blue 4 hrs 155 x 120 x 1200mm 15 8 CSS150 150mm Lt Blue 4 hrs 160 x 120 x 1200mm 15 8 CSS155 155mm Lt Blue 2 hrs 165 x 140 x 1200mm 12 10 CSS160 160mm Lt Blue 2 hrs 170 x 140 x 1200mm 12 10 CSS165 165mm Lt Blue 2 hrs 175 x 140 x 1200mm 10 10 CSS170 170mm Lt Blue 2 hrs 180 x 140 x 1200mm 10 10 CSS175 175mm Lt Blue 2 hrs 185 x 140 x 1200mm 9 10 CSS180 180mm Lt Blue 2 hrs 190 x 140 x 1200mm 9 10 CSS185 185mm Red 2 hrs 195 x 140 x 1200mm 9 10 CSS190 190mm Red 2 hrs 200 x 140 x 1200mm 9 10 CSS195 195mm Red 2 hrs 205 x 140 x 1200mm 9 10 CSS200 200mm Red 2 hrs 210 x 140 x 1200mm 8 10 ARC Party Wall Cavity Fire Barriers PWCSS75 75mm Red 4 hrs 80 x 250 x 1200mm 10 10 PWCSS100 100mm Red 4 hrs 105 x 250 x 1200mm 8 10 PWCSS120 120mm Red 4 hrs 125 x 250 x 1200mm 8 10 PWCSS125 125mm Red 4 hrs 130 x 250 x 1200mm 6 10 PWCSS140 140mm Red 4 hrs 145 x 250 x 1200mm 6 10 PWCSS150 150mm Red 4 hrs 155 x 250 x 1200mm 6 10 PWCSS200 200mm Red 4 hrs 205 x 250 x 1200mm 4 10 CSS300/65 65mm Red 4 hrs 300 x 65 x 1200mm 12 10 CSS300/75 75mm Red 4 hrs 300 x 75 x 1200mm 12 10 CSS300/100 100mm Red 4 hrs 300 x 100 x 1200mm 8 10 CSS300/115 115mm Red 4 hrs 300 x 115 x 1200mm 8 10 CSS300/120 120mm Red 4 hrs 300 x 120 x 1200mm 8 10 CSS300/140 140mm Red 4 hrs 300 x 140 x 1200mm 6 10 CSS300/150 150mm Red 4 hrs 300 x 150 x 1200mm 6 10

Dimensions & Packaging Specification: TCBs (Flanged) Product Code Suitable for Cavity Width TCB Colour Masonry Fire Rating Timber Frame Fire Rating Dimensions Pieces per pack TCB50 50mm Red 4 hrs 1 hr 65 x 65 x 1200mm 40 12 TCB75 75mm Green 4 hrs 1 hr 90 x 75 x 1200mm 35 12 TCB80 80mm Green 4 hrs 1 hr 95 x 75 x 1200mm 35 12 TCB85 85mm Orange 4 hrs 1 hr 100 x 100 x 1200mm 24 10 TCB90 90mm Orange 4 hrs 1 hr 110 x 100 x 1200mm 20 10 TCB95 95mm Orange 4 hrs 1 hr 110 x 100 x 1200mm 20 10 TCB100 100mm Orange 4 hrs 1 hr 120 x 100 x 1200mm 20 10 TCB105 105mm Yellow 4 hrs 1 hr 120 x 120 x 1200mm 15 10 TCB110 110mm Yellow 4 hrs 1 hr 125 x 120 x 1200mm 15 10 TCB115 115mm Yellow 4 hrs 1 hr 130 x 120 x 1200mm 15 10 TCB120 120mm Yellow 4 hrs 1 hr 135 x 120 x 1200mm 15 10 TCB125 125mm Yellow 4 hrs 1 hr 135 x 120 x 1200mm 15 10 TCB130 130mm Yellow 4 hrs 1 hr 140 x 120 x 1200mm 15 10 TCB135 135mm Yellow 4 hrs 1 hr 145 x 120 x 1200mm 15 10 TCB140 140mm Yellow 4 hrs 1 hr 150 x 120 x 1200mm 15 10 TCB145 145mm Yellow 4 hrs 1 hr 155 x 120 x 1200mm 15 8 TCB150 150mm Yellow 4 hrs 1 hr 160 x 120 x 1200mm 15 8 TCB155 155mm Yellow 2 hrs N/A 165 x 140 x 1200mm 12 10 TCB160 160mm Yellow 2 hrs N/A 170 x 140 x 1200mm 12 10 TCB165 165mm Yellow 2 hrs N/A 175 x 140 x 1200mm 10 10 TCB170 170mm Yellow 2 hrs N/A 180 x 140 x 1200mm 10 10 TCB175 175mm Yellow 2 hrs N/A 185 x 140 x 1200mm 9 10 TCB180 180mm Yellow 2 hrs N/A 190 x 140 x 1200mm 9 10 TCB185 185mm White 2 hrs N/A 195 x 140 x 1200mm 9 10 TCB190 190mm White 2 hrs N/A 200 x 140 x 1200mm 9 10 TCB195 195mm White 2 hrs N/A 205 x 140 x 1200mm 9 10 TCB200 200mm White 2 hrs N/A 210 x 140 x 1200mm 8 10 ARC Party Wall Cavity Fire Barriers PWTCB75 75mm White 4 hrs 1 hr 80 x 250 x 1200mm 10 10 PWTCB100 100mm White 4 hrs 1 hr 105 x 250 x 1200mm 8 10 PWTCB120 120mm White 4 hrs 1 hr 125 x 250 x 1200mm 8 10 PWTCB125 125mm White 4 hrs 1 hr 130 x 250 x 1200mm 6 10 PWTCB140 140mm White 4 hrs 1 hr 145 x 250 x 1200mm 6 10 PWTCB150 150mm White 4 hrs 1 hr 155 x 250 x 1200mm 6 10 PWTCB200 200mm White 4 hrs 1 hr 205 x 250 x 1200mm 4 10 TCB300/65 65mm White 4 hrs 1 hr 300 x 65 x 1200mm 12 10 TCB300/75 75mm White 4 hrs 1 hr 300 x 75 x 1200mm 12 10 TCB300/100 100mm White 4 hrs 1 hr 300 x 100 x 1200mm 8 10 TCB300/115 115mm White 4 hrs 1 hr 300 x 115 x 1200mm 8 10 TCB300/120 120mm White 4 hrs 1 hr 300 x 120 x 1200mm 8 10 TCB300/140 140mm White 4 hrs 1 hr 300 x 140 x 1200mm 6 10 TCB300/150 150mm White 4 hrs 1 hr 300 x 150 x 1200mm 6 10 Packs per pallet

Health and Safety ARC Building Solutions has an approved Health and Safety Policy and is committed to working and supplying products safely. ARC s rockfibre mineral wool is not classed as a possible human carcinogen. We have assessed products as required by Substances Hazardous to Health Regulations (COSHH). An ARC COSHH data sheet is available and can be downloaded from ARC s website. 2015 ARC Building Solutions Ltd. ARC and T-Barrier are registered trademarks of ARC Building Solutions Ltd.