!"Meets the Highest Standards in Sanitary Cleaning

Similar documents
kymeets the Highest Standards in Hygienic Cleaning

4.1 Tank Cleaning Equipment

Instruction Manual. Toftejorg TM SaniJet TM 20 Media Driven

kyalfa Laval Unique DV-ST UltraPure

Instruction Manual, Alfa Laval Toftejorg TM - SaniMidget SB - SaniMagnum SB - SaniMega SB

kythe Optimum Choice for Ultra-Clean Processes

kyproven Performance and Reliability

Alfa Laval Toftejorg Rotary Spray Heads MultiMidget & MultiMagnum

kyalfa Laval LeviMag UltraPure, Magnetic Mixer

Alfa Laval Toftejorg SaniMidget SB, SaniMagnum SB & SaniMega SB

kyalfa Laval LeviMag,MagneticMixer

Diaphragm seal with sterile connection With clamp connection (Tri-clamp) Models , and

kysimply Unique Diaphragm Valves

Unique RV-ST Regulating Valve

Instruction Manual. Toftejorg SaniJet 20 IM-TE91A595-EN041

kysimply Unique Regulating

In-line diaphragm seal with sterile connection For sanitary applications Model , aseptic connection per DIN 11864

Instruction Manual. Alfa Laval Toftejorg SaniMidget Retractor ESE01843-EN

Diaphragm seal with sterile connection With union nut (milk thread fitting) Models , , and

Diaphragm seal with sterile connection For sanitary applications Models , , and , threaded connection

Diaphragm pressure gauge, flush For sanitary applications Model PG43SA-S, NS 100

High-quality pressure sensor with mounted diaphragm seal With clamp connection Model DSS22T

Spare Parts. SMP-BCA Aseptic Mixproof Valve with PTFE Diaphragm SP70811-GB

Pressure gauge per EN with mounted diaphragm seal With clamp connection Model DSS22F

kyone Valve for All Solutions

Thermowell For sanitary applications Model TW61, for orbital welding

Thermowell For sanitary applications Model TW61, for orbital welding

Diaphragm seal with sterile connection For homogeniser machines Model

Diaphragm monitoring system with clamp connection For sanitary applications Model DMS-FP

Diaphragm pressure gauge, flush For sanitary applications, NS 100 Model PG43SA-D, with integrated diaphragm element monitoring

Sanitary Valves JSB Series Back Pressure Valves

Pressure transmitter UNIVERSAL CA

solids solutions group

Pressure gauge per EN with mounted diaphragm seal With SMS threaded connection Model DSS19F

Pressure gauge in hygienic design with mounted diaphragm seal With clamp connection Model DSS22P

Tank Equipment. A member of NEUMO Ehrenberg Group. Edition 1.1

Cleaning Technology DUNOS S DUNOS R DUNOS O SO EVERYTHING KEEPS FLOWING.

LKH UltraPure Centrifugal Pump

kysimply Unique Unique 7000 Series

kyalfa Laval Weighing Systems UltraPure with digital beam load cell

Instruction Manual Alfa Laval Toftejorg TM TJ20G

Kontrols & Industrial Weighing. IF flat-bed scales for use in the chemical, pharmaceutical and food industries.

Thermowell For sanitary applications Model TW61, for orbital welding

SensoGate WA 130 H. User Manual. Retractable Fitting

Pressure transmitter COMPACT ECOnomic

Cleanfit H CPA475. Technical Information. Retractable assembly for ph, ORP measurement under sterile conditions

LKH-90 4 poles = 1500/1800 rpm at 50/60 Hz.

The pumping action of the B series lobe displacement pump is achieved thanks to the counter-rotation of

Flow Measurement SITRANS F M. Flow sensor MAG 1100 F 4/57

SITRANS P measuring instruments for pressure

SUPRApak M Series Filter Housings SUPRApak Filtration For Medium Batch Depth Filtration

JSBLF Series Compact, High Purity Low Flow Back Pressure Regulating Valve

GEA Tuchenhagen VARIPURE Rotating Cleaner. for tank and vessel cleaning

IF flat-bed scales for use in the chemical, pharmaceutical and food industries.

GEA Tuchenhagen VARIPURE Orbital Cleaner. fortank and vessel cleaning. Tel: / Int'l: Fax: / Int'l:

The Proven Mixproof Range

Hovap series 8700 Hygienic Mixproof Process Valves Varioflow

Gas-actuated thermometer with switch contacts For sanitary applications, stainless steel version Model 74

Level sensor Magnetostrictive, high-resolution measurement principle Model FLM-H, for sanitary applications

bar. A) d = 8 mm A) d = 8 mm D) Cleaning Nozzles B) d = 7 mm Nozzles B) d = 7 mm E) Mixing C) d = 6 mm C) d = 6 mm.

Flow Measurement SITRANS F M

kyhygienic and reliable weighing solutions for your process

Thermowell For sanitary applications Model TW22

OPTISWITCH 6500 C Technical Datasheet

Sanitary Valves Mark 978LF Sanitary Control Valves. Sanitary Low Flow Control Valves. 3L/T-2R/S33 Series Mark 978LF Series. Features.

SITRANS F M. Flow sensor MAG 1100 F 3/59

Automatic sensor lock-gate for extreme applications with ceramic sealing to the proces

kymanual or Automatic - it s your Choice

Pneumatic operated 2/2-way Diaphragm Valve

ProCam. Metering Pumps

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

OPTIFLUX 6000 Technical Datasheet

kyin all shapes, sizes and standards

Automatic sensor lock-gate for extreme applications with ceramic sealing to the proces

Welding All assembly welds are full penetration. All welds are crevice and undercut free. Weld finish & detail drawings available upon request.

Instruction Manual. Alfa Laval Rotary Jet Mixer IM 10 ESE02265-EN Covering: Standard Machines TE91I600. Original manual

Air Operated Diaphragm Pumps for Sterile Applications within Pharmaceutical, Biotechnical and Food Industry

kyproven Performance and Reliability

Alfa Laval three-screw pump

Instruction Manual. SSB Retractor Stroke 60/120 Media-to-Spring

LINEAR AND ROTATING TYPE AUTOMATIC SELF-CLEANING LIQUID FILTERS

kyfor Smooth Operation of Your HTST System

EDELSTAHL. Kämmer Series Aseptic and Sanitary Valves

Technical Information Cleanfit CPA875

Instruction Manual. Unique Single Seat Valve - Manually Operated ESE00523-EN Original manual TD TD

GEA Tuchenhagen VARIPURE Static Cleaners

JUMO PEKA Process Connection Adapter

kysmall, Yet Flexible

kythe Premium Pump LKH Centrifugal Pump

Thermowell For sanitary applications Model TW61, for orbital welding

SVC/SHC Series. Sanitary Check Valves. NEW - SVC for vertical down process outflow and drain installations. Features

SMP-BCA Aseptic Mixproof Valve with PTFE Diaphragm

Instruction Manual. SSB Retractor Stroke 60/120 Air-to-Spring

The Cleanest Design. SRC Sanitary Remote-Controlled Valve PD US

kythe Compact Pump LKH-110 and LKH-120/P Multi-Stage Centrifugal Pump

Application: Sanitary Solutions

Resistance thermometer For sanitary applications Model TR22-B, for orbital welding

Magnetic-Inductive Flow Meter FMI

Series 240 Type and Type Pneumatic Control Valves Type 3347 Hygienic Angle Valve

Instruction Manual. SSB Retractor Stroke 60/120 Air-to-Air

Transcription:

.!"Meets the Highest Standards in Sanitary Cleaning Toftejorg SaniJet 0 Rotary Jet Head Application The device is designed for use in pharmaceutical, biotechnological, food and dairy processing applications and is suitable for tanks and vessels between 0. and 0 m.itisespeciallywell-suitedto processing highly viscous, foaming or thixotropic products and to chemical processing applications where product cross-contamination is unacceptable. Working principle The Toftejorg SaniJet 0 is a sanitary, rotary jet head device that cleans in a D indexed Golden Section pattern. It has an integrated self-cleaning (patentpending)andself-drainingdownpipe.thedrive mechanism is located outside the tank, leaving a minimum of parts inside the vessel or to be submerged into the product. The distance between the tracks of the jets ensures efficient removal of residual product from the tank surface, from the start of the cleaning sequence, allowing for quickjeteffectivecleaning. TECHNICAL. DATA Lubricant:................... Machine: Self-lubricating with the cleaning fluid Air motor: Can operate non-lubricated Surface finish:................ Product contact parts Ra 0.µm Impact throw length:............ 1. - m Min. tank opening:............. clamp Pressure Air supply pressure:............ bar Working pressure:............. -1 bar Recommended pressure:......... - bar Air driven Air quality:................... Clean, filtered max. 0µm Dry, dew point max. C Non-lubricated possible Free air consumption:........... Max. l/sec. ( m /h) Adjustable speed:.............. - 1 RPM Cleaning time:................ - 10 min PHYSICAL DATA Materials 1L (UNS S10), PEEK*, E-CFTE* Sealing: EPDM* (standard), FPM* FFKM* *FDAcompliance1CFR 1 Temperature Max. working temperature:........ 90 C Max. ambient temperature:........ 10 C Weight Media-driven machine:........... 9. - 1 kg Air-driven machine:............. 10. -1.kg Connections Inlet connection:............... Clamp: 1 ISO ) Tank connection:.............. Clamp: ISO ) Caution Avoid hard and abrasive particles in the cleaning liquid, as this can cause increased wear and/or damage of internal mechanisms. In general, it is recommended to place a filter in the supply line. Certificates. material certificate, Q-doc, Q-doc incl. FAT & SAT and ATEX.

Options with FFKM sealing Standard Design The Toftejorg SaniJet 0 is available in media-driven or air-driven version. Air-driven versions are equipped with a magnetic clutch for leakage-proof transmission. The air motor provides an effective drive for low flow machines in rough environments and for use in explosive hazard zones, provided it is installed according to safety instructions. The air motor has variable speed to adjust cleaning intensity. The sanitary construction of the Toftejorg SaniJet 0 is designed, with the aim to meet both European and American standards and regulations, such as EHEDG, USDA, FDA, A etc. As standard documentation, it can be supplied with a "Declaration of Conformity" for material specifications. ATEX approved, Category 1 for installation in zone 0/0. Qualification Documentation (Q-doc) Designed for the BioPharm and Personal Care industry for qualification of hygienic Tank Cleaning Machines. Developed in according to the ISPE V-model and GDP, Good Documentation Practice, and includes: RS (Requirement Specification); DS (Design Specification incl. Traceability Matrix); FAT (Factory Acceptance Test incl. IQ & OQ);.1 and USP Class VI Certificates; FDA Declaration of Conformity; TSE Declaration; QC Declaration of Conformity; SAT (Site Acceptance Test Protocol incl. IQ &); OQ for End-User Execution. Cleaning Pattern Example - xø.ls 0. min.. min..0 min. Flow Rate (Media & Air driven) Flow Rate Impact Throw Length, Media Driven m/h 10-0000 xø. 9 10-0001 m Flow rate xø. HS xø. LS Throw length xø. xø.ls xø.hs xø.0 xø 1 1 9 10 11 1 1 Recommended operating pressure: - bar bar 9 10 11 1 1 bar

Dimensions (mm), Media Driven M F Cleaning Time, Complete Pattern, Media driven Min. RPM of machine body min. RPM 10-000 1 D E N P 10 G A B 9 10 11 1 1 bar K L C H xø. xø.ls xø.hs xø J 10-000 A B C D E F G H J K L M,, 11, 0, 00, 00, 0 1 1 10. Ø90.9 Ø 11 Ø9 1 Clamp IO 1, 1 1000, 100, 100

Dimensions (mm), Air Driven F Impact Throw Length, Air Driven m Throw length M (RPM) xø. C A D (RPM) xø. N (1RPM) xø. (RPM) xø E (1RPM) xø. P 1 (1RPM) xø G 9 10 11 1 1 bar L H J K B 10-000 10-000 A B C D E F G H J K L M, 10, 1, 00, 00, 1000, 1.1 11..9.1... 0.91.0 1 Clamp IO 1, 1 100, 100

Options A. Electronic rotation sensor to verify D coverage B. Improved surface finish C..1 certification for metallic parts by request D. Adaptor " < " TRAX simulation tool TRAX is a unique software that simulates how the Toftejorg SaniJet 0 performs in a specific tank or vessel. The simulation gives information on wetting intensity, pattern mesh width and cleaning jet velocity. This information is used to determine the best location of the tank cleaning machine and the correct combination of flow, time and pressure to implement. A TRAX demo containing different cleaning simulations covering a variety of applications can be used as reference and documentation for tank cleaning applications. The TRAX demo is free and available upon request. Wetting Intensity (US gallon/ft ) 0.0 0.0 0.0 0.09 0.11 0.1 0.1 0.1 0.0 0. 0. 0. 0...9..9...1.1. 9. 11 1 1 SaniJet 0 SaniJet 0 TD -0 Dm Hm, Toftejorg SaniJet 0, x ø. mm, Time = 1. min., Water consumption = 11 l Dm Hm, Toftejorg SaniJet 0, x ø. mm, Time =. min., Water consumption = l

Cleaning Pattern, the Golden Section Toftejorg SaniJet 0 operates according to the patented Golden Section cleaning pattern (EP-Patent No.: 09, US-Patent No.:,9,), which is unique in building up a uniform pattern. The pattern starts very coarse and refines itself in a step-less way by laying out the tracks approximately in the middle of the two most distant tracks already made. This means that the jets always clean the areas Golden Section Cleaning Pattern containing the most remaining product, and thereby remove as much deposit as possible in the shortest possible time. In some instances, this method of cleaning can even render a complete cleaning pattern unnecessary. The Golden Section is the most suitable cleaning pattern for an effective pre-rinse. Traditional Cleaning Pattern

. ESE00EN 101 Alfa Laval reserves the right to change specifications without prior notification. ALFA LAVAL is a trademark registered and owned by Alfa Laval Corporate AB. AlfaLaval How to contact Alfa Laval Contact details for all countries are continually updated on our website. Please visit www.alfalaval.com to access the information direct.