Quick Setup Guide for IntelliAg Model YP40 20 Air Pro

Similar documents
Quick Setup Guide for IntelliAg Model YP Air Pro

Quick Setup Guide for IntelliAg Model 3PYP 12 Row Single Row Air Pro

Quick Setup Guide for IntelliAg Model YP Twin Row

Quick Setup Guide for IntelliAg Model YP

Population pre-def ned Every Row Population. For other pre-def ned are made to the system or if options are added to the base planter.

Full screen alarms identify abnormal or failed operation on all enabled system components/controls

ROW PRO DOWN PRESSURE

CONTROL SYSTEMS FOR PRECISION FARMING. IntelliAg puts the future of application control in your cab providing state-ofthe-art

CONTENTS 1.0 INTRODUCTION SAFETY... 5

Installation Instructions ISOBUS Liquid ECU

Manufacturing, Inc.

CFX-750 Display with the Field-IQ System: Spraying /Strip Till/Anhydrous Application Quick Reference Card

Planting. Press to Highlight Configuration. Gauge Wheel Load Alarm. Value must be entered for your specific planter and parallel arm combination

Reference Manual /12

FOLD SEQUENCE VERSION 2 & 3 ISO 6. Operator s Manual FOLD 1 FOLD 2 FOLD 3 FOLD 4 FOLD 5 FOLD 6 FOLD 7 FOLD 8 IMP-LIFT DISC COULTER MARKER

SENTRY ISOBUS Tip Flow Monitor. Software Version 1.00

RAM Rail Mount Kit RAM 201UD 5 Arm RAM 2461U Base RAM 235U Base, Double U-Bolt

WIRELESS BLOCKAGE MONITOR OPERATOR S MANUAL

HARRISTON PICK POTATO PLANTER

Seed and Fertilizer Rate Charts for the YP1625IR Yield-Pro Planter with Individual Row Control Meters

ADJUSTMENTS BEFORE GOING TO THE FIELD

Raven RS1 Guidance and Steering Calibration & Operation Manual. P/N Rev. A 09/17 E29677

Calibration & Operation Manual

Seed and Fertilizer Rate Charts for the YP3025A, YP4025A and YP4425A 30, 40 and 44-Foot 3-Section Yield-Pro Planters with Air-Pro seed meters

Troubleshooting a Planter that applies above or below target rate

Clutch Control. PN: November 2013 Rev E 1

CS 420RC. Solid De-icer Controller Configuration and Set-up Manual

Seed-Squirter. Installation Guide. APPLICATION SYSTEMS FOR PROFESSIONALS. How Can We Help?

Setup Tabs. Basic Setup: Advanced Setup:

Flight Systems. Replacement for KASSEC DESCRIPTION

AgXcel GX5 Install Guide for Integration into Trimble. where precision meets the soil... PO Box 1611 Kearney, NE

AGRICULTURAL 2019 PARTS CATALOG

INSTALLATION GUIDE Table of Contents

PRESSURE GOVERNOR, ENGINE MONITORING, AND MASTER PRESSURE DISPLAY MODEL: TCA100

VC-4820 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

Instructions for Micro-Trak Seed Rate Control Systems Used with AgLeader INSIGHT, INTEGRA One, Two and Three Section

Level-Up Motorhome Leveling

KONGSKILDE KONNECT 1000

Operator s Manual. Wi-Fi Air Drill Rate and Blockage ECU. MNST08205 P a g e 1 Software Revision 2.3.0

Idle Timer Controller - ITC Freightliner MT45 Contact InterMotive for additional vehicle applications

Spray Height Controller

ITCEMS950 Idle Timer Controller - Engine Monitor Shutdown Isuzu NPR 6.0L Gasoline Engine

ECONOMISER SERIES E2T USER MANUAL

6R / 5-BUTTON SERIES VEHICLE SECURITY SYSTEM

CS 430RC. Solid De-icer Controller Configuration and Set-up Manual

An ISO 9001:2008 Registered Company

RADION Automatic sprayer control Software version 1.07

2 WAY REMOTE STARTER & ALARM SYSTEM INSTALLATION GUIDE FCC ID NOTICE

ECO3-601/602 EcoStar III * Chevy Express/GMC Savana Contact Intermotive for additional vehicle applications

Intelli-Feed Controller User s Manual Intelli-Feed Digital Tachometer and Hourmeter

Idle Timer Controller - ITC515-A Ford Transit Contact InterMotive for additional vehicle applications

OPERATOR S MANUAL DO NOT USE OR OPERATE THIS EQUIPMENT UNTIL THIS MANUAL HAS BEEN READ AND THOROUGHLY UNDERSTOOD. PART NUMBER Rev.

SureFire Drives and Harnesses for use with John Deere Dry Rate Controller

Endeavor Fertilizer Controler" Electric Pump Fertilizer System for John Deere GS2 with Servo Control

Diagnostic Trouble Code (DTC) List

B-RAD Select USER MANUAL TABLE OF CONTENTS

SharpShooter With Rate Sync for Turf

Sprayer Control. Manual for SprayLink Cable Installations. Tank. Jet Agitator. Agitator Valve. Diaphragm Pump. Pressure Transducer.

CONTROLLER DIAGNOSTIC GUIDE

MODEL MCL-3212 SPEEDOMETER/TACHOMETER for 2012 up Dyna and Softail with 4 gauge

CurveMaker DFS v2.0 Dyna FS Ignition Programming Software

TOPCON APOLLO ISOBUS SEEDER CONTROLLER OPERATOR S MANUAL

IVTM Installation Manual

BLOCKAGE MONITOR. Proudly built in the U.S.A. by:

Model PRO-9675FT4 Owner's Manual

2007 Mercury Marine SmartCraft Gauges

Technical Training GEN I

Inlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

Vission 20/20 micro-controller. Operation and service manual

ADD-ON REMOTE STARTER TO AFTERMARKET SYSTEM

Section 55 Chapter 6

Product Overview. Shift light turns on when RPM is above programmed shift point. Stage 2 activation light turns on when Stage 2 is active.

International A26 (2017)

SmartFOAM. Electronic Foam Proportioning Systems. Models: Class A only 1.7AHP, 2.1A Class A/B 3.3, 5.0, 6.5 FOAM OPERATION QUICKSTART FSG-MNL-00179

TWO-WAY LCD AUTOMATIC TRANSMISSION REMOTE STARTER. User Guide

DICKEY-john Sales DICKEY-john Technical Support

R & D SPECIALTIES ROTROL I USER'S MANUAL

INSTALLATION GUIDE. FCC ID NOTICE

MONITOR INSTALLATION AND OPERATING INSTRUCTIONS VERSION

Operations Manual. Put the Pleasure Back into Boating! MANOP6000SEM01 Revision A

MaxxForce 11 and 13 ( )

TurfDefender Electronic Leak Detector Kit Reelmaster 5000, 6000 and 5010 Series Traction Units

Vehicle Security System

Installation. Part A, Section 3. This section covers the following unit configurations. Voltage 1, 2, 3. Vista Standard (V) A3EN-04-[3V-A-AAXV]-11

USERS MANUAL MCD REMOTE OPERATOR

QUICK INSTALLATION GUIDE

! WARNING To avoid risk of electrical shock, personal injury, or death, disconnect power to range before servicing, unless testing requires power.

e-ask electronic Access Security Keyless-entry

KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS

Wiring diagrams on page 29 are for reference only. For detailed vehicle wiring refer to Navistar documents.

AUTOMATIC AND MANUAL TRANSMISSION MODELS* *MUST USE M SERIES REMOTE STARTER!

with the AgGPS TrueGuide System Quick Reference Card

OPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets

Matrix Pro GS. Setup Guide. For use with software version 3.0x. TeeJet Aabybro Mølhavevej 2 DK 9440 Aabybro Danmark

Seed Rate Charts for the YP1225 or YP1625 Planters

Idle Timer Controller - A-ITC520-A Ford E Series Ford F250 - F Ford F250 - F550 (*B-ITC520-A) F650/F750

PRODUCT SERIES: DPG-2100

Operating Manual OBD Link Connector

Seed and Liquid Fertilizer Rate Charts for the YP2425 and YP2425F Planters

Transcription:

STEP 1: Pre-Programming Preparation: The Quick Guide assumes the Virtual Terminal, Master Switch, Working Set Master, Working Set Member, and all sensors have been connected and properly installed. Reference Operator s manual for installation instructions. NOTE: The master switch is only required for hydraulic control systems. Reference the manual for instructions to assign a master switch as an auxiliary input. Power on vehicle via ignition switch to activate Virtual Terminal (VT). Main menu will display pre-programmed default settings. If errors are detected (e.g., failed sensors, incorrect configuration) an alarm and code displays. Alarms are silenced by pressing the Alarm Cancel button. Refer to Operator s manual for troubleshooting assistance. The system has three user levels. The system loads in User Level 1 (operator level) at every power cycle. Access to User Level 2 and 3 screens to setup constants (system configuration) requires a password. STEP 2: Change User Level to Dealer Level To change the user level, a 6-digit password is required. Password includes the five-digit serial number found on the label of the Working Set Master or Information On the IntelliAg Main Work screen, press the Diagnostics button. TABLE A: Row At the Diagnostics screen, press the Information button. Status/Row At the Information screen, record serial number of WSMT. Width Press the Password button. Row Width 20 row width distance in inches to calculate seed rate correctly. NOTE: Using 15 planter in 30 mode should 5. On the Password screen, enter the 6 digit password as follows: enter the first digit as 2 for change On/Off Pattern to Every 2nd Row Off. User Level For the next five digits, enter the Working Set Master serial number taken Auto Update Width Enabled When enabled, implement width will automatically calculate. from the WSMT or Information If disabled, manually enter implement width. 6. Press the OK button. Dealer screens on appears at the bottom of screen confirming On/Off Pattern Every Row On On/Off Pattern indicates specific row patterns to be on the password and dealer screens are activated. or off. Select pre-defined planter All Row On pattern. For other pre-defined planter patterns or individual row 7. Press the Work Screen button to return to the Main Work settings, reference Operator s manual. STEP 3: Auto Configuration (Identifies sensors connected to each module) Pop/Block Pattern Every Row Determines which sensors are used to calculate population and those used only for blockage detection. Select Auto config is performed at the factory, but may need to be done in the field as changes Population pre-defined Every Row Population. For other pre-defined are made to the system or if options are added to the base planter. patterns, reference Operator s manual. Verify Auto Config results are correct. Check that the correct number of rows are assigned to the correct module and number of hopper sensors are assigned accurately. To Run Auto Config: Press the Next Page button until the Configuration button appears. Press the Configuration button. Press the AUTO CONFIG button. Hour glass will indicate system is being configured detecting the presence of seed or hopper sensors connected to each module and will be automatically assigned to the appropriate module. 5. When Auto Config completes, press the Row Assign button to display the Row Assignment screen to verify correct Row # is assigned to the correct module based on serial number. 6. # of rows assigned to each module. Configuration Screen Seed Sensor Configuration Screen STEP 4: Row Status/Row Width At the Row Assignment screen, press the Row I/O button. Begin entering desired values using Table A as reference. Press the Work Screen button when Row Status/Row Width configurations are complete to return to the Main Work STEP 5A: Material Configuration (Controlled Hydraulic Drive) 16 different materials can be configured for use as planter controls. Reference the System Configuration section in the Operator s manual for additional information. At the Main Menu screen, press the Control button. Select and press one of the Material buttons (Material 1-15. desired values from Table B 5. 6. (Optional) (Optional) SERIAL NUMBER 10001 10002 MODULE MODULE TYPE ADDR. -POM 1 -POM 2 10001-1R 3 10001 WSMT-GY 4 10002 10001-1R -POM 10001 -CFM MODULE ADDR. TYPE # OF ROWS Press the Control button to return to the Control Repeat steps 2-4 for additional materials. Press the Channel button to proceed to channel setup 5 6 7 1-1R 2 WSMT- GY ROW # s 1-9-16 3-1R 17-24 TABLE B1: Material Controlled Hydraulic Drive Matrl Label Matrl 1 Material Name can be customized to accurately define the material s type. Creating a name allows for quick identification at the Control Type Control Desired type of application control channel being used for a specific material. The Material Type must correctly match the Control Type to be able to select Material from the Material Summary screen and operate properly. Units Ks/Ac S/Sec Automatically changes with the type of material application selected. Changes units for target application. Preset Method Enable Enabled Preset Method allows 10 user-defined target rates to be adjusted from the Main Work screen using Inc or Dec buttons. A Disabled Preset Method increases/decreases the target rate based on the % values set at the Material Seeds per Rev See Manual Set to number of seeds per 1 disc revolution. Disc Low Limit 5 Set to desired min seed disc RPM. Disc High Limit 37 Set to desired max seed disc RPM. High Pop Alarm 15% This is the percentage above the target population of the planter channel if rows are assigned to the planter channel. If rows are not assigned to a planter, this is the percentage above average planter population for all unassigned rows. Low Pop Alarm 15% This is the percentage below the target population of the planter channel if rows are assigned to the planter channel. If rows are not assigned to a planter channel, this is the percentage below average planter population for all unassigned rows. Product Level Alarm Row Fail Rate 2/1 (2 seeds every 1 second) Sets the level to trigger an alarm alerting of low product levels. ed value is an estimate in volume. Set to desired number of seeds per second to trigger seed sensor failure alarm. 1

STEP 5B: Control Channel (Controlled Hydraulic Drive) Select Channel 1 and verify that the channel is set to Control. desired values using Table B2 as reference. After planter control setup, calibrate hydraulic valve by pressing the Valve Cal button. Ensure implement is raised. With brakes locked and transmission in PARK position, start engine. 5. Engage hydraulics and run engine at normal speed until hydraulic fluid is at operating temperature. 6. Verify point row clutches are turned ON. 7. Do NOT perform this step unless meters are installed in all locations across planter row units or drive damage will occur. Press the START button. Turn the master switch to the ON position. The valve calibration will immediately start. Keep the hydraulics engaged until the calibration completes. 9. When the screen indicates calibration is complete, press the Channel button to return to Channel 1 home 10. Turn the master switch OFF. 1 To set up additional control channels (planter or fertilizer control), press the Next Channel button. 1 Press the Work Screen button when channel configurations are complete to return to the Main Work Once a control channel has been established as Control, any new materials established as Control on the Material screen will automatically be added as optional materials for Control channels on the Control STEP 6A: Material Configuration (Split Air Regulation) It is recommended that when setting a control channel for split air, the material name be created as Air to eliminate confusion between the actual material and the control used. At the Main Work screen, press the Control button. Press Material button 16 for Split Air Control. Create Material Name as Air. desired values from Table C 5. Press the Channel button to proceed to the Channel TABLE B2: Control Type Control Set desired Channel Type as Control. Material Name Displays only materials that have been configured for the channel type. Control Mode AUTO Auto is used in normal operating conditions calculating the rate of how the system is running. Manual mode acts as an override if application rate sensors are inoperable allowing the use of increase/decrease buttons to set the flow rate for the control. Refer to System Configuration section of Operator s manual for additional information. Drive Type PWM A hydraulic valve varies the oil flow to the motor proportioned to the electric current supplied. Drive Frequency 100 Hz If not using a DICKEY-john supplied valve, see the manufacturer s specifications for drive frequency. Input Filter 50 Feedback frequency filter for the control channel. DO NOT CHANGE. Gear Ratio 900 Specifys the actual ratio from the feedback sensor to the seed meter shaft RPM. Number of revolutions the feedback sensor turns in relation to one revolution the seed meter turns. Sensor Constant 360 Sensor Constant establishes the number of pulses for one revolution of the feedback sensor. If a DICKEY-john application rate sensor is used, the value should be set to 360.0. # of Seed Rows 24 Entry of a specific number of seed rows for the control channel. Row assignment is given a priority based on the channel and will be assigned sequentially thereafter. Channel 1 is always assigned to the first set of rows, Channel 2 next set of rows, and so on. Channel Width 40 Manual entry of the channel width for rows assigned to a specific channel. Width calculation can be determined by # of planter rows assigned to the channel multipled by the row spacing. Precharge Time + 0.0 Typically used during startup conditions in the field, a Precharge time is a specified length of time a control channel will operate at the defined Precharge Ground Speed. Must be entered as a positive (+) number. Delay Time - 0.0 Length of time before the control channel will start after the master switch has been turned ON and the implement switch is in a lowered position. Must be entered as a negative (-) number. TABLE C1: Material Split Air Regulation Type Split Air Reg Desired type of application control channel being used for a specific material. CREATE MATERIAL NAME AS AIR. Units In H 2 0 Oz in 2 Automatically changes with the type of material application selected. Changes units for target application. Preset Method Disabled User-defined target rates can be configured and when enabled can be adjusted from the Main Work screen using the Increment/Decrement buttons. Target Rate 00 Establishes the desired rate of application in inches of H 2 0. Max Rate 5.00 Maximum application rate in inches of H 2 0. Min Rate 00 Minimum application rate in inches of H 2 0. Inc/Dec % 5% Percentage of change of the entered target rate applied each time the Increment/Decrement button is pressed on the Main Work 2

STEP 6B: Control Channel (Split Air Regulation) NOTE: Split Air Regulation must be configured as Control Channel 2 only. At the Control screen, press the Next Channel button. At Channel 2 screen, select Split Air Regulation as the Type. desired values from Table C Press the Work Screen button to return to the Main Work STEP 7: Row Monitor At the Main Work screen, press the Row Monitor button. desired values using Table D as reference. Press the Work Screen button to return to the Main Work STEP : Speed Set Calibration At the Main Work screen, press the Speed Set button. desired values using Table E as reference. Press the Work Screen button when ground speed calibration configurations are complete to return to the Main Work TABLE C2: Control Type Split Air Regulation Split Air Regulation Configure Control Channel 2 as Split Air Regulation. Material name Air Create Material Name Air. Control Mode Auto Control channel feedback based on air pressure sensor. Drive Type Air Reg 2 Automatically selects Air Reg 2 as drive type. Input Filter 79% Amount of filtering applied to the control channel feedback frequency. Pressure Drop 0 Difference in pressure sensor mounting location to the seed disk in inches of H 2 0. Pressure Slope 447.2269 The change in pressure sensor voltage to a frequency readable by the IntelliAg system and measured in inches of H20. Should only be adjusted by qualified personnel. Pressure Offset 00 Takes a zero point reading that provides a frequency when the fan is off. Press the Zero Pressure button to calculate frequency. Selection YP40 Select Selection of YP40 to automatically adjust to the appropriate calibration settings. Sensitivity Adjust 0 Increases or decreases the calibration parameters in the ranges of -10 to +10. Increasing response time makes the system respond quicker. TABLE D: Row Monitor Material Name See Instructions Material Name only appears on the Row Monitor screen when all control channels are disabled and material is set for Monitor Only. This is only used for ground drive/nonhydraulic applications to monitor population with high and low alarms. A material must be configured and selected to activate alarms. High Alarm Delay 5 Desired number of seconds that high population can be above high alarm point before alarm will sound. Low Alarm Delay 5 Desired number of seconds that low population can be below low alarm point before alarm will sound. Population Adjust 100 a % to allow for seed sensor population inaccuracies to achieve the desired population display. 100% represents true calculation. Population Filter 50 Set filter value to stabilize the monitored population display. Number can be set to 0% for no filtering and 99% for high level filtering. Row Fail Rate 2/1 (2 seeds every 1 second) Set to desired number of seeds per second to trigger seed sensor failure alarm. TABLE E: Speed Set Source Digital Frequency Select CAN Ground if radar is connected to ISO tractor cab harness. Select Digital Frequency if radar or hall-effect is connected to WSMT actuator harness. Gspd Constant 12192 Input based on pulse count produced by the ground speed sensor over 400 distance. See Operator s manual for calibration instructions. Shutoff Speed 0.5 mph Set desired minimum ground speed allowed before the system shuts off. Minimum Override Master Sw Timeout Gspd Fail Alarm Delay Precharge Ground Speed 0 mph Set to operate when actual ground speed falls below the designated value. Control will operate at this speed until actual ground speed rises above minimum override speed or actual speed drops below shutoff. 10 Set to desired number of seconds system shuts off if the master switch is turned on and there is no ground speed. Toggle master switch to restart the system and turn off alarm. 5 Set to desired number of seconds alarm sounds after the ground speed is zero and seed flow continues. (Monitor only) 0 Set to the desired speed the system will use when a precharge time has been enabled for a control channel. Refer to Table C1: Control for Precharge Time. This setting will only display when a Precharge Time has been entered. Implement Lift Enabled Implement lift switch, when enabled, displays an implement lift indicator on the Main Work screen indicating implement lift position as up or down. Control channels can be turned on and off without using the master switch. 3

STEP 9: Accessory Sensor Hopper Assignment At the Main Work screen, press the Next Page button. Press the Configuration button to display the Configuration At the Configuration screen, press the Hopper Assign button. Press Hopper Set button. 5. desired values using Table F as reference. RPM Assignment STEP 12: Clutch Folding Operation The planter section controls turn the left, center, and right clutch controls on and off. The master switch must be in the ON position to activate any planter section. When a clutch control is ON, a green light will illuminate. Marker/Fold Switch should be in the UP (Marker) position during planting. In the DOWN (Fold) position, the switch controls the fold of the main frame. The fertilizer pump switch is turned ON when in the UP position. Press the switch in the DOWN position to turn OFF. 5. Lift/Hitch switch should be in the UP (Lift) position during normal operation. In the hitch position, the switch should be in the DOWN (Hitch) position to unlock and extend the telescoping tongue in preparation of folding the implement for transport. Lift/Hitch switch MUST be in the hitch position and hydraulic circuit in FLOAT when transporting planter equipped with hydraulic-operated tongue hitch. NOTE: Lift/Hitch switch has no function if planter has standard 3-point hitch operated tongue hitch. STEP 13: 5 Revolution Test Press the Control button. Press the Channel button. Press the Next Page button. 5. 6. Ensure implement is raised before starting 5 Rev Test. With brakes locked and transmission in PARK position, start tractor engine. Engage hydraulics and run engine at normal speed until hydraulic fluid is at operating 7. temperature. Press the 5 Rev button.. 9. Test Ground Speed and Row data must be entered to perform test. Press and hold remote test button to initiate 5 Rev Test. STEP 14: Summary Screen The Summary screen provides an overview of setup constants for active control channels. 6. MASTER Left Center Right Marker Fert. Pump Lift At the Configuration screen, press the Acc Assign button. Press the RPM button. # of RPMs, if required.note: There must be at least 1 RPM sensor configured before the RPM button appears on the desired values using Table F as reference. STEP 10: Clutch Folding (CFM) The CFM is installed in the cab to control row clutches, marker, fold, fertilizer on/off, lift and hitch. At the Main Work screen, press the Clutch CFG button to access the Clutch Configuration screen and verify that the correct # of clutches are configured for the system. The Clutch CFG button only appears as a top level button when a planter output module and clutch folding module are installed. # of Clutches 3 OUTPUT LEFT CENTER RIGHT # OF ROWS ROW # s 1-9-16 17-24 At the Main Work screen, press the Next Page button. Press the Summary button To view specific control channel configurations, press the respective control channel box 1- Press inside a yellow highlighted box to open a specific screen for editing. 5. Press the Work Screen button to return to the Main Work Summary Screen TABLE F: Accessory Hopper # of Hoppers 1 (base unit) 1 more (optional) Master CFM Switch # of hopper sensors connected to each module (4 sensors maximum). # of hopper data items for each listed module and the Hopp # s value will automatically populate if Auto Config is used to configure installed sensors. Logic Level Active Lo Sets the active state to low signifying that an alarm is generated if the sensor s output is in a low state. Use this setting if the connected sensor outputs a low condition when empty similar to the DICKEY-john hopper sensor. Alarm Delay 5 sec Controls the delay time between the detection of a high/low hopper alarm condition and the generation of the resulting alarm. The value is entered in seconds. Channel Assigns hopper sensor to channel. RPM High Alarm (fan speed) Low Alarm (fan speed) 3000 rpm Sets the RPM value at which a high RPM warning error is generated. 100 rpm Sets the RPM value at which a low RPM warning error is generated. High Alarm Delay 10 sec Establishes the delay between the detection of a high RPM alarm condition and the resulting alarm display. The value is entered in seconds. Low Alarm Delay 10 sec Establishes the delay between the detection of a low RPM alarm condition and the resulting alarm display. The value is entered in seconds. RPM Constant 3 pulses/rev Number of pulses per sensor revolution. RPM Filter 0 Filters the signal out of the RPM sensor. Disable Control on Low Alarm Disabled Allows for disabling of all control channels if the RPM value of the selected sensor falls below the low alarm level setting. Marker or Fold Fertilizer Pump On/Off Lift or Hitch CLUTCH Fold Hitch 4

- Hydraulic Tongue Option 46790134 Battery + Tractor 46792000S1 46793502 CFM 46794220S1 2 Hitch B1 2 Hitch B2 1 Lift 46420517 Left Section 46791724 Rows 1-46790144 46790134 or Hydraulic Tongue Option 4679046 Tractor Cab 46790455 46790452 (5 Terminal) or 46790451A (10 Terminal) CFM 46790330 CAN 46790126 Chassis Ground Virtual Terminal Seed Monitor 46791100S1 Note: Connect the WSMT Actuator and the Dj to the mating connectors of the WSMT Middle Section 46791707 Rows 9-16 WSMT II 4679015S1 Hopper Level Sensors 46790410 Actuator 46790160 46791201A 46790143 WSMT 46790151 46790143 1 Marker 2 Fold 46420517S1 46792000S1 4642051S1 46790473 Right Clutch 1 46420511S1 1 Left Clutch 46790471 2 Center Clutch 46790471 46793504 2 to Fold Lock Valve Clutch Control Connect Cab to Implement Can Tractor ECU Controller (46795060S1) Implement CAN Breakaway 46790134 Optional Hydraulic Tongue or to Application Rate Sensor (Channel 1-4 Feedback) Labeled FB1-FB4 Ignition switched +12VDC. NOTE: This wire must be connected to switched +12VDC Master Switch (46790124S1) Radar Speed Sensor 46733000S1 (Radar connected to either tractor harness or WSMT as shown below) ACTUATOR HARNESS 46790160 PWM Solenoid Valves 4662032S1 20 45790115 RS232 GPS (46790451 ) Adapter 46790172 Accessory Sensors connection to WSMT Actuator 46790160 Pressure Sensor 46790496 Right Section 46791724 Rows 17-24 Seed Monitor 46791100S1 46791201A Can 46790144 46790361 Rear Hitch 2 Pump Clutch 4642051S1 466790470 46790136 46792000S1 Boom 3 and Bypass 46790430 Fertilizer Pump Option 1 (Not Used) Boom 1 and 2 46790430 Can 46793503 Hopper Level Sensor 46620720S3 Implement Lift 46620713 Actuator 467096050 Implement Lift Sensor 46420520S1 If no implement lift sensor is used, connect the IMP LIFT leads together Fan/Shaft RPM Sensor 466970014S1 5 45790126 Hopper 46620714 Fan 45960922 System Component Installation Servo Valves (Labeled Servo 1 and Servo 2) Test Switch Radar Speed Sensor 4673300S1 (Radar connected to either tractor harness or WSMT as shown below) Locate and install system components as shown in the diagram. Note how the modules are identifi ed and which modules are located on which sections in this system. Connect module harnesses together with included extensions. s connect to the WSMT harness connection. Plug all unused connectors with included dust plugs. Secure any excess wires with tie-wraps. See Operator s Manual for additional installation information. 5. Power on monitor and program with correct constants as described on this Quick Start Guide. 5