O 2 CO CO 2 NO NO 2 NO x

Similar documents
Benefits of sulphuric acid. dewpoint temperature. monitoring

Online data sheet GMS800 FIDOR EXTRACTIVE GAS ANALYZERS

PRODUCT CONFORMITY CERTIFICATE

THC Heated FID 3-300A

AVL Particle Measurement System Aviation

Online data sheet S710 E S700 EXTRACTIVE GAS ANALYZERS

Zirconia Oxygen Probe

Physical Property Analyzer PPA4100 Series. On-Line RVP Analyzer

HHGA5A. Independent Hand Held 5 Gas Analyzer or use with MODIS TM Link & VERUS TM Bluetooth Link Features and Benefits

DUST ALERT BinMaster Price Book binmaster.com Subject to change without notice 1

SMARTLINK METER. Digital Self-checking Thermal Mass Flow Meter

DSL-220 MkIII Single Pass Opacity Monitor Measures 0-100% Opacity

ZMT & ZFG2 Zirconia Oxygen Analyzer Systems. Superior technology and quality from the world leader in oxygen measurement

Model Q45H/ Residual Chlorine Monitor...

Carbon Monoxide Transmitter

SMARTLINK METER. Digital Self-checking Thermal Mass Flow Meter

Flash Point Process Analyzer

DMT PERFORMING UNDER PRESSURE DMT. Pressure Scanner Features. Applications. Description 1/7

StackFlowMaster FPD581, FPD583 and FPD585 Stack gas metering systems

MEMFlo MFTV METAL BODIED FLOW METER WITH CLEAR TOP

Portable TOC Analyser for Stack Emissions

Pressure Transmitter

FurnaceDoctor -DPT Dewpoint Analyzer. User Manual Version 008

mass flowmeter for compressed air

DSL-240 MkIII Single Pass Dust Monitor Measures mg/m 3 using DDP

Inline Ultrasonic Flowmeter

Mobrey MLT100. Displacer Level Transmitter. Product Data Sheet February 2015 IP119, Rev CA. Level, contents or interface measurement transmitter

Optidew Vision Optical Dew-Point Meter

CEMTEK Instruments- NH3 Analyzer Quick Start Manual

9900 Series Oval Flowmeter/Transmitter with SMART METER MANAGER

Pursuing high precision, speed, and ease of use

Viscosense 3. Viscosity Measurement & Control Systems. Product Bulletin TO BE REALLY SURE

CHAPTER 9 : TYPE II TEST ON SI ENGINES (VERIFYING CARBON MONOXIDE EMISSION AT IDLING)

Mid-West Instrument. Series 700 "Wet/Wet" Installation and Operating Instructions. Differential Pressure Transmitter

MARINE APPROVED CEMS GREEN EFFICIENCY ON BOARD

Process Analyzer. Cold Filter Plugging Point Process Analyzer CFPP-4. Credible Solutions for the Oil and Gas Industry

display on the wall or in a panel away from the inline sensor SE30 for easy meter reading.

Monitoring Air Emissions on Ships. Restricted Siemens AG 2014 All rights reserved.

CAMS. Combustion Airflow Management System. Proven solutions for a tough industry. Precision Airflow Measurement An ONICON Brand

RCM. Direct Reading Flowmeter. for Liquids or Gases

Sarasota FD900 Sarasota ID900 Sarasota PD900 Gas Density Meters for Gas Metering and Control

OCX 8800 Oxygen/Combustibles Transmitter

mass flowmeter for compressed air

Wöhler A 450 Flue Gas Analyzer

2SGT. Electronic Pressure Instrument. Three Separate Functions in a Single Loop-Powered Device

ABB Instrumentation. Thermal Mass Flowmeter Sensyflow. Intelligent solutions for accurate gas mass flow measurement

User's Manual: Series 270I Model 270I Process Current Loop-Powered Isolator

INTERNATIONAL METAL ENGINEERING

DTC P20EE, P249D, P249E, or P2BAD

CHAPTER 3 EXPERIMENTAL SET-UP AND TECHNIQUES

Model DS1000/DT20 System

Section 3 Technical Information

Dissolved Oxygen Measurement System with Air Blast Cleaner

Combustion Control Problem Solution Combustion Process

KANEAUTO 4-4 & KANE AUTO 5-4

BOILER BLOWDOWN CONDUCTIVITY CONTROLLER (CONTINUOUS METHOD)

Dräger EM200-E Diesel Exhaust Measurement

Continuous Gas Analyzers, extractive

Accurate measurement of compressed air consumption and detection of leaks. Measuring the individual consumption per customer / cost centre

Lightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions

Silver Series Thermal Dispersion Airflow Measurement Technology

Sentinel Panametrics Custody Transfer Gas Ultrasonic Flowmeter

Mid-West Instrument. Piston Type Model 220. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

Low Cost, Low Maintenance Air, Compressed Air and Nitrogen Flow Measurement for Process and Plant Applications

BAS Construction Checklist

Digital ph transmitter

8000 Series Liquid Flow Meter

TYPE APPROVED CEMS GREEN EFFICIENCY ON BOARD

STEEMCO-MAS Flowmeter for Steam

ABB MEASUREMENT & ANALYTICS DATA SHEET Hydrazine monitor

LTX RF LEVEL SENSOR. Instruction Manual

973 Dew Point Mirror. Portable Industrial Chilled Mirror Hygrometer. Typical applications: REFLECTING YOUR STANDARDS

Sentinel. Panametrics Custody Transfer Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

Sentronic PLUS 614 Series

8000 Series Liquid Flow Meters

Digital ph transmitter

VariStroke II Electro hydraulic Actuator

better analysis counts

FPA4 DATASHEET JUNHO 2013

State-of-the-art viscosity monitoring

Online data sheet FLOWSIC100 VOLUME FLOW MEASURING DEVICES

INSERTION flowmeter with paddle wheel, ELEMENT design

Certificate: TNU112UML0348/ Test report: 112UML0348 / of 14 January 2013

Type Type 1001 Transducers. I/P & E/P Transducers

Portable pressure calibrator, Wally Box III Model CPH7600

HUMIDITY / TEMPERATURE TRANSMITTER

Output signal active note. Measuring range rel. pressure. Electrical Data Power supply DC V, ±10%, 1.1 W

VORTEX IN-LINE FLOW METERS

tekson TS Series Low Cost Ultrasonic Water Energy Flow Measurement

CHAPTER 4 VARIABLE COMPRESSION RATIO ENGINE WITH DATA ACQUISITION SYSTEM

Mid-West Instrument. Diaphragm Type Model 240. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

Technical Offer. Antek Model 6200 Analyzer Determine Total Sulfur and Total Nitrogen in a single analyzer

Electric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 inch NPT

Electric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 inch NPT

Flow VA 500/ 520. Flow sensors for compressed air and gases incl. temperature measurement. Verbrauch.

Rosemount TM OCX 8800 Oxygen and Combustibles Transmitter

Cabinet-built single drives, ACS880-07

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

NO ENTRY No entry for Models 605, 610 or 620. Enter maximum flow rate for Model 600 with external flow sensor

Vortex Eggs Delta Flowmeter

Transcription:

continuous emissions monitoring O 2 CO CO 2 NO NO 2 NO x FGA 900 Series Combustion & Environmental Monitoring

FGA Continuous Emissions & Combustion Efficiency Monitoring The FGA range of analyzers use dual sensor technology to measure the levels of Nitrogen Oxides, Carbon Monoxide and Oxygen in flue gas. Land s measurement technique ensures stable long-term operation with high accuracy and very low drift. Engineered for ease of maintenance and packaged for the industrial environment, FGA series analyzers are simple to install and trouble-free in operation. for stand-alone use or as part of a fully-integrated system - to meet the demands of modern environmental legislation. Features & Benefits Fully integrated system in a single compact box - no additional components required Suitable for a wide range of applications - up to 3 gases in a single analyzer Low maintenance - straightforward servicing without specialist skills Proven high performance - dual sensor measurement technique, TÜV & MCerts approved/certified to US EPA standards True measured Total NOx - separate NO + NO 2 sensors for true NOx monitoring, no converters necessary Simple installation - locate the analyzer anywhere, including outside locations Automatic calibration option - for continuous unattended operation in compliance monitoring applications Combustion Efficiency measurement option - for optimizing process efficiency where conditions are changing Compact Weatherproof Design FGA analyzers are very compact. The choice of installation location and access is therefore made much simpler. They are packaged in weatherproof cabinets, intended for mounting directly on to a convenient wall or structure, inside or outside. True NOx Measurement The analyzer measures both NO and NO 2 separately, these are combined to give a true NOx measurement output. The inherent problems with catalytic NO 2 converters are therefore completely avoided.

Flexible Configuration FGA analyzers are available in a range of configurations, as shown in the table. Automatic Calibration Each analyzer is fitted with manual calibration as standard. Automatic calibration is optional and enables the analyzer to perform a calibration without operator intervention. Efficiency A calculation of overall combustion efficiency can be made for process optimization. It is optional on analyzers fitted with Oxygen sensors. Gas Type Model CO O2 NO NO2 NOx 900 930 940 942 945 950 CO 2 A calculated CO 2 output can be provided on all models that measure O 2. 8 1 2 7 6 9 4 5 15 10 11 14 12 13 15 16 17 3 How the Analyzer Works FGA is an extractive sampling multi-gas analyzer system. The flue gas is extracted using a sample probe. The gas is then transported via a sample line, to the cooler unit fitted inside the analyzer, where the moisture is removed. The dry and cooled sample gas is then filtered to remove particulates before being directed into the measurement system. The measurement system is made up of pairs of sensors. Each sensor is fed alternately with sample gas and air. The sensors generate an electrical output in proportion to a specific gas component. Measured values are then displayed and output as analog signals (4-20 ma). Key 1. Flue Gas Stream 2. Sample Probe 3. Sample Line 4. Peltier Sample Cooler Unit 5. Catch Pot 6. Particulate Filter 7. Flow Indicator 8. Air Inlet 9. Solenoid Valves 10. Sample Pumps 11. Gas Sensor Pair #1 12. Gas Sensor Pair #2 13. Gas Sensor Pair #3 14. CO Sensor Purge Unit 15. Exhaust Hot Sample Gas Cooled/Cleaned Sample Gas Air Measurement Channel #1 Measurement Channel #2 Calibration Gas 16. Automatic Calibration Gas Module (optional) 17. Calibration Gas to Sample Probe (with automatic option)

FGA SYSTEMS CEM Systems - Tailored to your Needs FGA series analyzers are extremely compact, and are ideal for incorporation into custom-built systems. Land can create solutions which conform with the most exacting specifications. From sitespecific installation drawings to complete system engineering packages, has the experience to produce designs which perform to the highest standards. Special mounting arrangements Gas bottle cabinets and regulators Termination boxes and isolation relays Multiple probes with manual or automatic selection Explosion-proof systems Customer-specific drawings and manuals Probes and Sample Lines for all Applications Our experience will help determine which probe and type of sample line will give the best possible results in your application. A full range of heated and unheated probes, filters and sample lines is available to meet all requirements; and more importantly, to keep operating continuously and very efficiently, with the minimum of maintenance. Heated filter probes Ceramic probes for hot or acidic conditions Regulated and self-regulating heated sample lines Unheated sample lines Advanced Capability Systems The FGA II series of analyzers can measure up to six gases (CO, NO, NO 2, SO 2, O 2 and CO 2 ) in the same compact format. The ChillerProbe is a stack-mounted sampling system, which uniquely filters and cools the flue gas at the sampling point, before being transported to the FGA II for analysis. For further information please refer to data sheets for FGA II Analyzer (pds 195) and FGA II ChillerProbe (pds 199). Data Acquisition and Reporting Comprehensive data acquisition and analysis systems are available with all FGA analyzers. The PC-based software is a highly flexible and fully configurable data acquisition and reporting system for continuous emissions monitoring systems. This inherent flexibility enables it to meet the requirements of Environmental Regulation Authorities throughout the world.

Key Components of the Analyzer 1 2 4 3 5 6 7 18 8 9 17 16 10 11 15 14 13 12 5 Dual Sensor Technology Key FGA analyzers use Dual Sensor Technology to give high measurement accuracy and repeatability. The main advantage of this technology is the automatic zero drift correction the analyzer performs every 30 minutes. In addition, the analyzer performs a measurement verification during the drift correction cycle, ensuring a reliable, repeatable reading. Continuous emissions monitoring systems using dual sensor technology are in use worldwide and have been certified to US EPA standards PS-3, PS-4 and PS-4A; are MCerts certified; and TÜV approved to the 13 th and 17 th BImSchV and TA Lüft. 1. Power Switch & Fuse 2. LCD Display 3. Menu Operation Keys 4. Electronics Panel 5. Sample Line Connection Boot (optional heated/anti-freeze sample line) 6. Compressed Air Inlet 7. Sample Gas Inlet (standard sample line) 8. Peltier Sample Cooler Unit 9. Particulate Filter 10. Catchpot 11. Condensate Peristaltic Pump 12. Condensate Drain 13. Calibration Gases and Air Inlets # 14. Calibration Gas Flowmeter and Needle Valve # 15. Calibration Gas outlet to probe 16. Sensor Units 1, 2 and 3 17. Sample Pumps 18. Solenoid Valves # Fitted on Automatic Calibration models only

Further Information U.K. Dronfield, Derbyshire S18 1DJ Telephone: +44 (0) 1246 417691 Facsimile: +44 (0) 1246 290274 E-Mail: combustion.info@landinst.com Web: www.landinst.com U.S.A. 10 Friends Lane Newtown, PA 18940-1804 Telephone: +1 215 504 8000 Toll Free: (in USA) 800 523 8989 Facsimile: +1 215 504 0879 E-Mail: combsales@landinstruments.net Web: www.landinstruments.net Italy Via dell Industria, 2 20037 Paderno Dugnano, Milano Telephone: +39 02 91 08 0020 Facsimile: +39 02 99 04 0418 E-Mail: info@landinst.it Web: www.landinst.it France 7 Parc des Fontenelles 78870 Bailly Telephone: +33 (0)1 30 80 89 20 Facsimile: +33 (0)1 30 80 89 21 E-Mail: combustion@landinst.fr Web: www.landinst.fr Poland ul. Michalowskiego 5/2 31-126 Krakow Telephone: +48 (0) 12 632 82 62 Facsimile: +48 (0) 12 632 24 74 E-Mail: land@land.com.pl Web: www.land.com.pl Mexico Av. Horacio 1132 Planta Baja B Col. Polanco, D.F. 11550 Telephone: +52 (0) 55 5281 1165 Facsimile: +52 (0) 55 5281 5364 E-Mail: ventas@landinstruments.net Specifications Measurement Ranges CO Ranges: 0-50 ppm up to 0-2 000 ppm NO Ranges: 0-50 ppm up to 0-2 000 ppm NO 2 Ranges: 0-50 ppm up to 0-200 ppm Resolution: 1 ppm / 1 mg/m 3 Linearity: < 2 % of range Zero drift: < 2 % of range per month Span drift: < 2 % of range per month O 2 Ranges: 0-5 % to 0-25 % Resolution: 0.1 Vol % Linearity: < 0.2 Vol % Zero drift: < 0.2 Vol % per month Span drift: < 0.2 Vol % per month Calibration: Microprocessor controlled Standard Manual gas selection Display: LCD with backlight Indicators: External Power On and System OK LEDs Outputs/Inputs Analog outputs: Relay outputs: Relay rating: Inputs: Isolated current loop outputs One per gas measured plus NOx if NO & NO 2 measured Efficiency (on instruments with selected option) 0, 2 or 4 to 10 or 20mA. System OK, Maintenance/Calibration Isolated changeover S.P. 1 A @ 240 V a.c. 5 A @ 24 Vd.c. resistive for Alarm - one per gas measured Span and Zero Gas Relays for calibration gases Current loop inputs for ambient & process temperatures (only needed for efficiency calculation) Environmental Environmental rating: IP65 / NEMA 4 Operating (ambient) temperature: 0 to +35 C / 32 to 95 F standard to -20 C / -4 F with optional case heater to + 50 C / 122 F with optional air conditioner Compliance Measurement standards: Meets the requirements of ISO 12039, ISO 10849 & ISO 7935 Approvals: TÜV approved to the 13 th & 17 th BImSchV and TA Lüft MCerts certified Continuous Emissions Monitoring System USEPA certified to PS-3, PS-4 and PS-4A Electrical safety: Conforms to EN-61010-2 EMC: Conforms to EN-50 081 & EN-50 082 Power Power supply: 110 V a.c. or 230 V a.c. ±20%, 50-60 Hz Power consumption: 300 W Gas and Air Requirements Instrument air (zero calibration): 2 bar / 30 psi clean and dry, 5 l/min / 0.2 cfm Instrument air (cooling): 2-10 bar / 30-150 psi clean and dry, 90 l/min / 3 cfm Calibration gas (recommended): 2 bar /30 psi, 5 l/min / 0.2 cfm 20 litres / 0.7 cu.ft. per calibration approx. Calibration gas type: Specific to each gas type and measurement span Dimensions (H x W x D): 600 x 600 x 350 mm / 24 x 24 x 14 Weight: 53 kg / 117 lb Options Special Measurement Ranges Automatic Calibration Efficiency Measurement Probe Type Sample Line Type Case Heater Air Conditioner/Vortex Cooler Continuous product development may make it necessary to change these details without notice Copyright 2003-2006 has a comprehensive range of Combustion and Environmental Monitoring Instrumentation. TÜV approved www.landinst.com Approval applies to products designed and manufactured in the UK Approval applies in the USA Sira MC 040019/00 - MC 040026/00 PDS207/05/06