Accurate Labs, 311, 312 Govinda Complex, GIDC Char Rasta, Vapi, Valsad, Gujarat. Discipline Mechanical Calibration Issue Date

Similar documents
Institute for Design of Electrical Measuring Instruments, Swatantryaveer Tatya Tope Marg, Chunabhatti, Sion, Mumbai, Maharashtra

Discipline Mechanical Calibration Issue Date Certificate Number C-0393 Valid Until Last Amended on - Page 1 of 6

A.A. Calibration Pvt. Ltd., 13-C/18, Vasundhara Haat, Vasundhara, Ghaziabad, Uttar Pradesh. Discipline Mechanical Calibration Issue Date

Alcalab Private Limited, 3rd Floor, Ashiana Trade Centre, Adityapur, Jamshedpur, Jharkhand. Discipline Mechanical Calibration Issue Date

Calitron Calibration Laboratory, U1: 207, Kohinoor Arcade, Tilak Chowk, Nigdi, Pune, Maharashtra

Discipline Mechanical Calibration Issue Date Certificate Number C-0208 Valid Until Last Amended on

Discipline Mechanical Calibration Issue Date Certificate Number C-0752 Valid Until Last Amended on - Page 1 of 6

Hi-Tech Calibration, 307, 3rd Floor, Govinda Complex, Char Rasta, Vapi, Gujarat. Discipline Mechanical Calibration Issue Date

Accurate Measurements, Plot No.103, D Block, Meethapur Ext., Badarpur, New Delhi. Discipline Mechanical Calibration Issue Date

Central Mechanical Engineering Research Institute, Mahatma Gandhi Avenue, Durgapur, West Bengal

Discipline Mechanical Calibration Issue Date Certificate Number C-0751 Valid Until Last Amended on

Cal-Tech Calibration Services Pvt. Ltd., Flat No.8, Avadhut Heights, Anand Nagar, Sinhgad Road, Pune, Maharashtra

Caliber Gauges & Instruments Laboratory, S. No. 14/1, Dattadigamber Soc. B, Warje Jakat Naka, Pune, Maharashtra

Q-Tech Engineering Services, S-134, C/o, Precision Engineering Works, MIDC, Bhosari, Pune, Maharashtra

QA Tech (A Division of GMP Technical Solutions Pvt. Ltd.), L-73, Verna Industrial Estate, Verna Salcette, Goa

ICL Calibration And Testing Services, SCO - 37, Ground Floor, Sector-12, Panchkula, Haryana. Discipline Mechanical Calibration Issue Date

Autocal Solutions Pvt. Ltd., Plot No. BG-74, Gala No. 1 & 2, Jai Tulja Bhavani Indl. Premises, Telco Road, MIDC Bhosari, Pune, Maharashtra

CERTIFICATE OF ACCREDITATION

Shriram Institute For Industrial Research, 14-15, Sadarmangala Industrial Area, Whitefield Road, Bangalore, Karnataka

Schedule. 200 C to 400 C. 400 C to 660 C C to 800 C C to 1300 C C to 1200 C. 0 C to 1700 C. 0 C to 1700 C.

Page : 1 of 16. FIELD OF TESTING : Calibration and Measurement CALIBRATION & MEASUREMENT CAPABILITY EXPRESSED AS AN UNCERTAINITY *

Schedule. 300 mm to 600 mm 600 mm to 1000 mm inch to 12 inch

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Rev /07/2015 CATALOGUE - CALIBRATION SERVICES 1

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Metrology Laboratory, CMTI, Central Manufacturing Technology Institute, Tumkur Road, Bangalore, Karnataka Accreditation Standard ISO/IEC 17025: 2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

CERTIFICATE OF ACCREDITATION

Price List. Calibration Fee

Standard Scales SERIES 182 Made of Low-Expansion Glass. Working Standard Scales SERIES 182 E-32

Hellenic Accreditation System. Annex F2/17 to the Certificate No SCOPE of ACCREDITATION

Welcome to Garber C O R P O R AT E O V E R V I E W

Height Master Page 345. Check Master Page 349. Calibration Tools Page 354

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Certificate of Accreditation


Measuring. Affordable. Effective. Instruments

TEST AND CALIBRATION SERVICES Ensuring quality and reliability.

IEC SYSTEM FOR CONFORMITY TESTING AND COMMITTEE OF TESTING LABORATORIES CERTIFICATION OF ELECTRICAL EQUIPMENT

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Annex to the Accreditation Certificate D-K according to DIN EN ISO/IEC 17025:2005

Certificate of Accreditation

CALIBRATION SYSTEM CERTIFICATE

Scope of Accreditation For Global Instrumentation Services, LLC 523 N. Sam Houston Parkway E, Suite 230 Houston, TX Gavin Lewis

PROMPT ENGINEERING P.O. BOX BARWA VILLAGE, WAKRA, BUILDING NO. 6 SHOP NO. 19 AND 20 DOHA QATAR

TopPette Mechanical Pipettes


Certificate of Accreditation

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Ref:CL/Mech./ Cal /BID-01(13-14) Date: 10 July 2013

ACCREDITATION FACILITY AUDIT CHECKLIST

Transferpette. Testing Instructions (SOP) 1. Introduction. May 2009


Rotary Positioning Stages Introduction

Carl Stuart Ltd. Tallaght Business Park, Whitestown, Dublin 24. Calibration Laboratory Registration number: 270C

UGANDA NATIONAL BUREAU OF STANDARDS NATIONAL METROLOGY LABORATORY

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

TRI-STATE INSTRUMENT SVC, INC

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017. Data Weighing Systems 255 Mittel Drive Wood Dale, IL Steven A. Thomas CALIBRATION

Page 1 of 5. United Testing Systems, Inc S. Acacia Avenue Fullerton, CA William Warner, Quality Manager

VITLAB Dispenser. Standard Operating Procedure (SOP)

SCOPE OF ACCREDITATION TO ISO/IEC & KS Q ISO/IEC

Small Tool Instruments and Data Management

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Certificate of Accreditation

Certificate of Accreditation

Small Tool Instruments and Data Management

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Faculty of Mechanical Engineering B.E. Mechanical Engineering (Sandwich) (R 2013) Semester III. Requirements for a batch of 30 students

Transferpette. Testing Instructions (SOP) 1. Introduction. October 2013

Certificate of Accreditation

Certificate of Accreditation

Certificate of Accreditation

Accredited Laboratory

Shawal CGC Calibration Profile

Catalog # Meeting Your Metrology Needs. A.A. Jansson, Inc. Precision Measuring Service and Equipment

DYNAMICS LABORATORY. AIM: To apply the knowledge gained in kinematics and dynamics of machines to real system.

CALIBRATION PRICE LIST

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

NADAR SARASWATHI COLLEGE OF ENGINEERING AND TECHNOLOGY VADAPUDUPATTI, THENI DEPARTMENT OF MECHANICAL ENGINEERING LAB FACILITIES

SVENSK STANDARD SS-EN ISO Volymetrisk mätapparatur med kolv Del 6: Gravimetriska metoder för bestämning av mätfel (ISO :2002)

Gear Measurement. Lecture (7) Mechanical Measurements

INSPECTION. (b) Using a wire brush, remove all the carbon from the combustion NOTICE:

III EC6362 ELECTRONIC CIRCUITS AND DIGITAL LABORATORY

ANAUM INTERNATIONAL ELECTRONICS LLC. Test and Measurement Calibration Services Test Bench.

Gauge Blocks - Reference for Precision

Calibration Laboratory Assessment Service CLAS Certificate Number Page 1 of 5

1P D 6681 Final Report Cover Sheet

P5510. Users Manual. Pneumatic Comparison Test Pump. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

INSPECTION. (b) Clean the combustion chambers. Using a wire brush, remove all the carbon from the combustion NOTICE:

BRAKE BOOSTER. Section 5. Brake Booster. Construction. Single Diaphragm Booster

HA Thickness Gauge IS:2386 (part 1)- 1963

SAMPLES GAUGES. Tolerances OUR SPECIAL OFFER: PLUG GAUGES WITH REQUIRED FIT OR INDIVIDUAL TOLERANCES ACCORDING TO YOUR SPECIFICATIONS

OVERHAUL. 1. INSPECT 1ST GEAR THRUST CLEARANCE (a) Using a feeler gauge, measure the 1st gear thrust clearance.

Lecture (7) on. Gear Measurement. By Dr. Emad M. Saad. Industrial Engineering Dept. Faculty of Engineering. Fayoum University.

Re: Extension for ISO/IEC 17025: 2005 accreditation Certificates #ACT-1997, ACT , ACT & AT

INSPECTION. (b) Using a wire brush, remove all the carbon from the combustion NOTICE:

ADJUSTING VALVE CLEARANCE

Transcription:

Last Amended on - Page 1 of 9 I. DIMENSION 1. CALIPER $ Vernier L.C. 0.01mm 7.5 µm 9.0 µm Using Caliper Checker & Slip Gauges L.C. 0.05mm 29.5 µm 30.0 µm Dial / Electronic L.C. 0.02mm 12.5 µm 13.5 µm 2. HEIGHT Vernier L.C. 0.01mm Dial / Electronic L.C. 0.02mm 7.5 µm 9.0 µm 12.5 µm 13.5 µm Using Caliper Checker & Slip Gauges 3. EXTERNAL MICROMETER $ 0 to 25 mm 0 to 150mm 0 to 150mm >150mm to 600 mm 1.8 µm 2.0 µm 6.1 µm 7.3 µm Using Mick Check Set & Slip Gauges

Last Amended on - Page 2 of 9 4. DIAL GAUGE PLUNGER $ 0 to 10 mm 0 to 50 mm 1.0 µm 6.0 µm Using Single Axis 5. DIAL GAUGE LEVER TYPE $ 0 to 0.8 mm 0 to 1.6 mm 1.0 µm 6.0 µm Using Single Axis 6. BORE (For Plunger Movement only) 0 to 1 mm 0 to 1 mm 1.0 µm 5.8 µm Using Single Axis 7. PLAIN PLUG Up to 225 mm 1.26 µm Using Single Axis 8. PLAIN RING Up to 200 mm 2.53 µm Using Single Axis 9. SNAP Up to 150 mm 1.0 µm Using Single Axis

Last Amended on - Page 3 of 9 10. DIAL SNAP Up to 150 mm 6.0 µm Using Slip Gauge 11. PISTOL CALIPER $ L.C. 0.05 mm Up to 150 mm 29.0 µm Using Slip Gauge 12. DIAL THICKNESS Up to 20 mm 5. 8 µm Using Slip Gauge 0 to 1 mm 1.0 µm 13. FEELER Up to 3 mm 2.15 µm Using Micrometer 14. MEASURING PIN Up to 20 mm 2.15 µm Using Micrometer 15. FOILS $ Up to 2 mm 2.15 µm Using Micrometer 16. LENGTH MEASURING MACHINE $ (Horizontal) L.C. 0.001mm/0.0001 mm Upto 300 mm 1.3 µm Using O Grade Slip Gauge Set & Long Gauge Blocks

Last Amended on - Page 4 of 9 17. STEEL SCALE $ Upto 1 mtr 32.0 µm Using Std Scale with DRO 18. MEASURING TAPE $ Upto 50 mtr 19. BEVEL PROTRACTOR $ L.C. 1' L.C. 5' 0 to 90 to 0 to 90 0 to 90 to 0 to 90 31.5 L m 1000 Where L is in m 0.8 min 0.8 min Using Std Scale with DRO Using Angle Gauge 20. COATING THICKNESS Upto 1 mm 6.12 µm Using Standard Foils 21. THREAD PLUG Up to 225 mm 2.1 µm Using Single Axis as per IS: 2334:2001 IS:4218(part 1 to 5) 22. THREAD RING Up to 100 mm 1.4 µm Using Single Axis as per IS: 2334:2001 IS:4218(part 1 to 5)

Last Amended on - Page 5 of 9 23. DEGREE PROTRACTOR $ 0 to 90 to 0 35 min Using Angle Gauge As per IS: 4239:1970 24. COMBINATION SET $ 0 to 90 to 0 35 min Using Angle Gauge As per IS: 4239:1970 25. PROFILE PROJECTOR/ OPTICAL MICROSCOPE VISION MEASURING MACHINE Linear X & Y Axis L.C.0.0001/0.001/0.005mm Upto 200 mm 3.4 µm Using Slip Gauge Upto 200 mm 7.0 µm Angular L.C. 1 min of arc L.C. 5 min of arc 0 to 360 0 to 360 3.0 min of arc 5.0 min of arc Using Angle Gauge Block Magnification 10x to 100x 0.6% Using Glass Scale II. ACCELERATION & SPEED $ 1. SPEED (RPM) (Contact Type) 200 rpm to 5000 rpm 0.10 % rdg to 0.02 % rdg Using Photo Type Tachometer (Non Contact Type) 100 rpm to 10000 rpm 0.11 % rdg to 0.06% rdg Using Stroboscope By Direct Method

Last Amended on - Page 6 of 9 III. ACCOUSTIC $ 1. SOUND LEVEL METER 94 db & 114 db 0.7 db Using Sound Calibrator 2. SOUND CALIBRATOR 94 db 0.91 db Using Sound Level Meter IV. MASS 1. WEIGHTS $ (Conventional Mass) 1 mg 0.01 mg Using Standard Weights 2 mg 0.01 mg of E 2 (1mg to 200 g), F 1 5 mg 0.01 mg class (500 g to 10kg), 10 mg 0.01 mg M 1 Class (20kg) & 20 mg 0.01 mg weighing balance(s) 50 mg 0.01 mg with resolution of 100 mg 0.02 mg 0.01 mg (1mg to 50 g), 200 mg 0.02 mg 0.1 mg (100g & 200 g ), 500 mg 0.02 mg 1 mg ( 500 g & 1 kg), 1 g 0.02 mg 0.01 g (2 kg & 5 kg), & 2 g 0.02 mg 0.1g (10kg & 20 kg) 5 g 0.03 mg as per 10 g 0.03 mg OIML R 111:2004 20 g 0.03 mg 50 g 0.04 mg 100 g 0.2 mg 200 g 0.2 mg 500 g 2 mg 1 kg 2 mg 2 kg 0.01 g 5 kg 0.02 g 10 kg 0.1 g 20 kg 0.4 g

Last Amended on - Page 7 of 9 2. WEIGHING BALANCE # (Electronic) 1 mg to 500 mg 0.09 mg Using Standard Weights 500 mg to 50 g 0.10 mg of E 2 (1mg to 200 g), F 1 50 g to 200 g 0.4 mg class (500 g to 10kg), 200 g to 1 kg 0.005 g M 1 Class (20kg) 1 kg to 5 kg 0.05 g as per OIML R 76:2006 5 kg to 10 kg 0.6 g 10 kg to 20 kg 0.8 g V. VOLUME $ 1. MICROPIPETTE (Piston Operated Pipette) 10 µl to 100 µl 100 µl to 1000 µl 0.02 µl 0.02 µl Using Standard weights of E 2 Class, weighing balance with resolution of 0.01mg & distilled water By Gravimetric Method as per ISO 8655-6 : 2002 2. LABORATORY GLASSWARE 1ml to 10 ml 0.04 µl Using Standard Weights o 10 ml to 50 ml 0.20 µl E 2 (1g to 200 g), 50 ml to 200 ml 0.3 µl F 1 class (500 g to 10kg), 200 ml to 1 L 0.014 ml M 1 Class (20kg) & 1 L to 5 L 0.03 ml weighing balance(s) with 5 L to 20 L 0.4 ml resolution of 0.01 mg (1ml to 50 ml), 0.1 mg(>50 ml to 200 ml) 1 mg( >200 ml& 1 L), 0.01 g (>1L to 5 L), & 0.1g (>5 L to 20L) By Gravimetric method as per IS/ ISO 4787: 2010

Last Amended on - Page 8 of 9 VI. PRESSURE 1. PNEUMATIC DIAL PRESSURE GAUGES & DIGITAL PRESSURE GAUGES # 0 to 30 bar 0 to 560 mmwc 0.075 bar 0.45 mmwc Using Digital pressure gauge with pneumatic pump By Comparison method as per DKD-R-6-1 2. HYDRAULIC DIAL PRESSURE GAUGES & DIGITAL PRESSURE GAUGES $ 0 to 60 bar 0 to 1000 bar 0.12% rdg 0.15% rdg Using Hydraulic Dead Weight Tester By Direct method as per DKD-R-6-1 30 bar to 200 bar 0.12 bar Using Digital pressure gauge with hydraulic pump By Comparison method as per DKD-R-6-1 3. HYDRAULIC DIAL PRESSURE GAUGES & DIGITAL PRESSURE GAUGES 30 bar to 300 bar 0.27 bar Using Digital pressure gauge with hydraulic pump By Comparison method as per DKD-R-6-1

Last Amended on - Page 9 of 9 VII. VACUUM # 1. DIAL GAUGES & DIGITAL VACUUM GAUGES -0.9bar to 0 bar 0.006 bar Using Digital Vacuum gauge with hydraulic pump By Comparison method as per DKD-R-6-1 * Measurement Capability is expressed as an uncertainty ( ) at a confidence probability of 95% $ Only in Permanent Only for Site Calibration # The laboratory is also capable for site calibration however, the uncertainty at site depends on the prevailing actual environmental conditions and master equipment used.