EnLink Midstream Contractor Covered Task List Last updated 11/8/2017

Similar documents
Energy Transfer Partners LP Contractor Covered Task List Last updated 3/2/2018

Southern Star Central Gas Pipeline Contractor Covered Task List Last updated 8/15/2018

Williams Contractor Covered Task List Last updated 11/7/2017

Energy Transfer Partners LP Contractor Covered Task List Last updated 12/10/2018

Northern Natural Gas Contractor Covered Task List Last updated 4/26/2018

Enbridge Gas Transmission and Midstream and Enbridge Liquid Pipelines (Express-Platte) Contractor Covered Task List Last updated 8/30/2018

TransCanada US Contractor Covered Task List Last updated 9/27/2018

Howard Midstream Energy Partners LLC Contractor Covered Task List Last updated 10/11/2013

DCP Midstream Contractor Covered Task List Last updated 7/11/2018

Columbia Pipeline Group Contractor Covered Task List Last updated 1/8/2018

Noble Energy Contractor Covered Task List Last updated 2/20/2019

Saddle Butte Rockies Midstream LLC Contractor Covered Task List Last updated 12/6/2017

Dominion Energy Questar Pipeline LLC Contractor Covered Task List Last updated 10/3/2017

Boardwalk Pipeline Partners, LP Contractor Covered Task List Last updated 9/17/2018

Epic Consolidated Operations LLC Contractor Covered Task List Last updated 9/6/2018

Black Hills Energy Contractor Covered Task List Last updated 10/10/2018

Appendix B Kinder Morgan Operator Qualification Program List of Covered Tasks Hazardous Liquid Pipelines Part 195 revised 8/24/2018

Appendix B Kinder Morgan Operator Qualification Program List of Covered Tasks Hazardous Liquid Pipelines Part 195 revised 12/12/2017

Appendix A Kinder Morgan Operator Qualification Program List of Covered Tasks - Natural Gas - Part 192 Revised 12/13/2017

ASMECourseCatalog.

COVERED TASK Conduct Cathodic Protection Surveys 1 DESCRIPTION ELEMENTS OF TASK 4 PART QUESTION NOTES ABNORMAL OPERATING CONDITIONS

Operator Qualification (OQ) Report

Florida City Gas Contractor Covered Task List

PIGGING PRODUCTS. Capex supply. PIG LAUNCHER and RECEIVER

PHMSA Office of Pipeline Safety Dave Mulligan Western Region

PIPELINE CORROSION CONTROL

Highway Crossings - Cased or Uncased

PROCEDURE EXTRUDED HOT TAP & LINE STOP TEES DESIGN & MANUFACTURING VALIDATION

Inspector's Initials: Tank Owner or Agent Signature: Title: Date:

Pipe Support The Fast, Economical Solution for Low Pressure Pipeline Repair

No Infrared Refrigerant Leak Detector

New UST Installation Inspection Checklist

Official Journal of the European Union L 298/39

CHAPTER 115 LEAK DETECTION AND REPAIR (LDAR) PROGRAM CHANGES

SPCC Regulation Integrity and Leak Testing Methods

Broetje-Automation Company Standard Structural component specification for welded parts

The Implementation of a Storage Facility Inspection Program. Presented By: John R. Rueckel PCA Engineering, Inc.

GUIDELINE FOR GLOVEBOXES THIRD EDITION AGS-G001 February 2007

PIPELINE INSPECTION SURVEY QUESTIONNAIRE

Bolting QA/QC Bulletin

Client Success Story Sheri Baucom Senior Advisor II

ANNUAL UST SYSTEM INSPECTION CHECKLIST

Monthly Checklist For Depot

HDPE FUSIBLE VALVES EXPECT INNOVATION

CONTENTS. Foreword...iii. 1. Introduction...1

GF Piping Systems. SurTap System Operation with VersaTap Fittings Manual

An Introduction to Constructing and Maintaining Cathodic Protection Systems

Monitoring Cathodic Protection of Natural Gas Pipelines

Baumann Sanitary Diaphragm Angle and Inline Control Valve

PIPELINE PIGS types of mechanical pigs. Pig length (inches) = 1 and ½ pipeline diameters.

This article discusses a tank

Cathodic Protection for AST s. Why is Cathodic Protection Important?

Methodologies and practices for non-piggable lines Andreas Landsteiner Integrity Department - Transalpine Pipeline (TAL)

Type B (Extruded Branch) Sizes 4 through 30

Asset Protection Cathodic Protection Testing of Insulating Joints. Work Instruction No.:

INSTALLATION, OPERATION, & MAINTENANCE MANUAL Models # MM-30, MM-30HT, MM-50, MM-50HT, & MM-50 EXL with Special HP Tool and Special HP EXL Tool

THE APPLICATION OF LONG RANGE GUIDED ULTRASONICS FOR THE INSPECTION OF RISER PIPES

3-20 2FII & Groundhog Bonded Seat Butterfly Valve. Operation and Maintenance Manual. Job Name: Contractor: Date:

First Quality Solutions

Steel Tank Maintenance. Fluid Fertilizer Foundation December 4, 2012

Daikin Steam Coils. Installation and Maintenance Manual IM 901. Types HI-F5, HI-F8, & E-F5. Group: Applied Air. Part Number: IM 901

Rolls -Royce M250--C47M OPERATION AND MAINTENANCE

HOT TAPPING & PLUGGING SOLUTIONS

Atmos Energy DOT Report-Distribution Leaks Cause of Leak WTX LA MS CO KS KY M-TX TN VA Total

Inline Ultrasonic Flowmeter

FINAL REPORT CATHODIC PROTECTION EVALUATION. 42-Inch Water Transmission Pipeline Contract 1 Station 0+00 to South Texas Water Authority

LINE STOPPING. Extending and modifying your existing pressurized system while it s under full operating conditions.

PIPELINE INTEGRITY CONFERENCE BHR GROUP 5th-7th NOVEMBER 2008 SCHIPOL, THE NETHERLANDS PIPPELINE IN INDIA

The Gradient Control Mat (GCM)

Mass Tank Inspection Services, LLC 29 Abbey Lane Middleboro, MA masstankinspection.com

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER SAMPLE / INJECTION PUMP

This publication is copyrighted and intended for the sole use of General Industries - 07/07/2016

Hand Expansion Valves Built Stronger to Last Longer Sizes: 6mm (¼ ) to 305mm (4 )

LACT MEASUREMENT. Total Head = Or PSI = S.G. 2.31

Technical Offer. Antek Model 6200 Analyzer Determine Total Sulfur and Total Nitrogen in a single analyzer

EXPECT SUPREME PE BALL VALVES

INSTALLATION INSTRUCTIONS

GAS DISTRIBUTION PRODUCTS METER RISERS

SECTION FACILITY FUEL - NATURAL GAS PIPING AND SYSTEMS

SECTION PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER AUTOMATIC INSERTION PROBE

CASE STUDY ON PIPELINE UNDER-PROTECTION ALONG WITH MITIGATION METHODS. Vipul Vilas Sawant. Mahanagar Gas Ltd, Mumbai, India

24-48 HP250II Butterfly Valve. Operation and Maintenance Manual. Job Name: Contractor: Date: Document #: 2448HP250OOOM Revision Date: 1/10/11

Report of Inspection

RELIABLE AND EFFICIENT SYSTEMS

NOTICE: Section 1.22 Connecting Rod

ESTABLISHMENT OF ULTRASONIC TESTING IN UNIQUE DESIGNED PARTIAL PENETRATION END PLUG OF HEADER IN BOILERS.

Mitigation of External Corrosion on Buried Carbon Steel Pipeline Systems July/2018

Provides the perfect seal, protects flanges, valves and pipelines against corrosion whilst improving safety and reducing the risk of fire.

Report No.: Name of Ship: Plans referred during Initial Survey:

Baumann Mikroseal Control Valve

2" - 24" OS Series Butterfly Valves. Operation and Maintenance Manual. Job Name: Contractor: Date:

GUIDE FOR CERTIFICATION AND INSPECTION OF WHEEL SHOPS. Routine Special Shop Certification Follow up Inspection

PENNSYLVANIA ABOVE GROUND STORAGE TANKS

Application for Permit to Install Underground Storage Tanks (Petroleum or Hazardous Substances) 1. Owner Information 2. Installation Site Information

Underground Storage Tank Annual Compliance Inspection (Revised 1/2015)

PANASONIC FIRE ALARM SOLUTIONS ACCESSORIES LIST AE2010 Series

2200 North Main Street Washington, PA PH: FX:

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

VALVES, FIRE HYDRANTS, AND APPURTENANCES

Transcription:

003 Test Breakout Tank Overfill Protective Devices 195.428 Oral 004 Inspect and Calibrate Breakout Tank Overfill Protective Devices 195.428 005 Repair Breakout Tank Overfill Protective Devices 195.428 006 Inspection of Breakout Tanks 195.432 Oral and Certificate 007 Operate Valves 008 Measurement of Wall Thickness with Ultrasonic Device 009 Movement and/or Relocation of Liquid Pipelines 195.424 010 Routine Visual Inspection of Breakout Tanks 195.432 011 Inspect, Test and Maintain Computational Pipeline Monitoring (CPM Sensing Devices 012 Inspect, Test and Maintain Liquid Leak Detection Flow Computers 013 Inspect, maintain and Test Tank Gauges for CPM Hazardous Liquid Leak Detection 014 Maintain/Prove Flow Meters for CPM Hazardous Liquid Leak Detection 015 Inspect, Test and Maintain Gravitometers/Densitometers for CPM Hazardous Liquid Leak Detection 016 Purging - Hazardous Liquids 195.402(c(10 018 Inspect Navigable Waterway Crossing 195.412(b 020 Pump Stations/Units - Startup, Operation and Shutdown 195.402(c(7 195.402(c(8 021 Start-up/Shutdown of Liquid Pipeline to Assure Operation within MOP 026 Inspect/Test Pump Station Remote Shutdown Devices 195.402 195.406 195.262 040 Isolation of Pipe with Mud Plug 195.402(c(11 195.402(c(14 103 Non-destructive Testing (Other than testing of welds -- Mag Particle 195.452(h Page 1 Copyright 2019. Veriforce, LLC. All rights reserved. Rev. 10

201 Abnormal Operating Conditions Related to Welding on Pipelines 192.225 192.227 192.715 192.717 192.713 192.245 202 Monitoring of Welding Process 192.241(a 192.241(c 192.231 192.235 192.245 203 Visual Inspection of Welds not Non-Destructively Tested 192.241(b 192.241(c 204 Non-Destructive Testing (Dye Penetrant 192.243 205 Non-Destructive Testing (Mag Particle 192.243 206 Non-Destructive Testing (Ultrasonic 192.243 207 Non-Destructive Testing (X-Ray 192.243 208 Plastic Pipe Joining: Butt Fusion 192.281 192.283 192.285 192.287 209 Plastic Pipe Joining: Mechanical Joining 192.281 192.283 192.285 192.287 210 Plastic Pipe Joining: Electrofusion Joining 192.281 192.283 192.285 192.287 195.222 195.214 195.230 195.224 195.226 195.204 195.224 195.228 195.234 Oral 195.204 Oral 211 Perform Plastic Fusion Inspection 192.287 213 Joining of Metal Pipe and Components by means other than Welding - Threaded and Flanged Connections 214 Joining of Metal Pipe and Components by means other than Welding - Threaded Connections 215 Joining of Metal Pipe and Components by means other than Welding- Flanged Connections 192.271 192.271 192.271 216 Joining of Metal Pipe - Compression Couplings 192.271 195.126 195.126 No 1:0 1 No 1:0 1 No 1:0 1 Page 2 Copyright 2019. Veriforce, LLC. All rights reserved. Rev. 10

217 Small Diameter Metal Tubing and Fitting Installation 192.271 301 Install Tracer (electrically conductive Wire 192.321(e NA 401 of Buried Pipelines When Exposed 192.459 404 Protection of Coating When Backfilling and From Below Ground Supports 192.461(d 192.614(c(6 192.461( c 192.319(b 195.569 195.252 195.422 405 Protection of Coatings From Above Ground Structures 192.461(d 406 Conduct Test to Determine Cathodic Protection Current Requirements 192.465(a 407 Perform Cathodic Protection Survey 192.465(a 192.465(e 192.328(e 195.571 195.573(a 408 Inspect Cathodic Protection Rectifier 192.465(b 195.573( c 409 Inspect Interference Bonds 192.465(c 195.573( c 410 Clear Shorted Casing 192.467(c 195.401(b(1 195.575(a 411 Inspect/Test to Assure Electrical Isolation is Adequate 192.467(d 195.575 412 Install CP Leads on Pipeline Using Exothermic Weld 192.471 195.567 413 Anode Installation on Submerged Pipeline or Facilities 192.471 414 Inspect for Internal Corrosion Whenever Pipe is Removed 192.475(b(1 415 Monitoring for Internal Corrosion with Probes and Coupons 192.477 192.620(d(5 416 Monitoring for Internal Corrosion with Gas Samples 192.477 195.579(c 195.579(b 417 Atmospheric Corrosion Monitoring 192.481 195.581 418 General and Localized Corrosion Measurement (Remedial Measures 192.485(a(b 419 Cathodic Protection Potential Measurement 192.465(a 192.620(d(8 195.585(b 195.587 195.573(a 421 Measurement of Depth of Pitting with Pit Gage 192.485 195.569 195.585 Page 3 Copyright 2019. Veriforce, LLC. All rights reserved. Rev. 10

422 Assessment of Pipeline Segments Using Long Range Guided Wave UT 423 Perform Direct Current Voltage Gradient (DCVG Survey 192.490 192.620(d(7 424 Perform AC Current Attenuation (ACCA Survey 192.490 192.328(e 192.620(d(7 425 Perform Alternating Current Voltage Gradient (ACVG Survey 192.112(h(3 192.620(d(7 426 Inspect Pipe Coating with Holiday Detector 192.455(a 192.457(a 192.461 192.479 427 Inspection of Coating Application 192.461(a 192.461(c 195.588 195.588 195.588 195.561 195.569 195.561(a Oral 428 Pin Brazing to Install CP Leads on Pipeline 192.471 195.567 429 Monitoring for corrosion - bacteria testing - serial dilution method (MIC 436 Perform Close Survey 192.328(e 192.465(e & (7 195.573(a 437 Perform Hot Spot Survey 192.465(e 195.573(a 480 Apply Approved Coating by Hand Application 192.461(a 195.557 195.559 195.581 482 Apply Approved Coatings by Mechanical Spray and Hand Application Methods 192.461(a 195.557 195.559 195.581 484 Apply Approved Coatings by Wrap Application 192.461(a 195.557 195.559 195.581 501 Conduct a Pressure Test 192.505 192.507 192.513 192.328(d 502 Conduct Pressure Test on Pipe that is to be Operated at a Pressure <100 psig 601 Start-up/Shut-down of Pipeline to Assure Operation Within MAOP / MOP 192.509 192.511 192.513(b 192.605(b(5 602 Monitoring Pipeline Pressure 192.605(b(5 192.619 195.304 195.305 195.306 195.402 195.406 195.402( c (9 195.406 Oral Page 4 Copyright 2019. Veriforce, LLC. All rights reserved. Rev. 10

603 Compressor Units: Startup, Operation, Shutdown and Purging Before Returning to Service 192.605(b(7 192.605(b(6 605 Locate Line/Install Temporary Marking of Buried Pipeline 192.614(c(5 195.442(c(5 606 Locate and Mark Submerged Pipelines 192.614(c(5 607 Damage Prevention: Observation of Excavating and Backfilling 192.614(c(6 192.319(b 195.252 195.442(c(6 608 Damage Prevention for Blasting Near a Pipeline 192.614(c(6 195.442(c(6 Oral 609 Inspect and Maintain Odorization Equipment 192.625(e 610 Monitor Odorant Concentration 192.625(f 611 Hot Tap (Steel Pipe 192.627 612 Hot Tap (Plastic Pipe 192.627 613 Purge Pipeline Facilities With Gas 192.629(a 614 Purge Pipeline Facilities With Air or Inert Gas 192.629(b 195.422 195.402(c(10 Oral 616 Atmospheric Monitoring during Hot Work Operations 195.402( c (11 619 Damage Prevention during Vacuum Excavation and Backfilling Activities 661 Launching and/or Receiving Internal Devices (Pigs 192.937(c 192.476 192.620(d(5(iv 192.620(d(9 701 Patrolling Pipeline and Leakage Survey without Instrument 192.705 192.613 192.706 192.620(d(4 192.721 192.614(c(6 195.442(c(6 Oral 195.426 195.412(a Oral 702 Leakage Survey with Leak Detection Device 192.706 703 Placing/Maintaining Line Markers 192.707 195.410(a 195.410(c 704 Permanent Field Repair by Grinding 192.713 195.226 195.230 707 Permanent Field Repair Using Bolt-On Clamp/Sleeve 192.717 195.422(a 195.585(a(2 Oral Page 5 Copyright 2019. Veriforce, LLC. All rights reserved. Rev. 10

708 Permanent Field Repair Using Full Encirclement Weld Sleeve 709 Inspection and Testing of Relief Devices (Compressor Stations, Meter Stations, Regulating Stations 710 Inspect/Test Compressor Station Remote Shutdown Devices (ESD/EBD 192.717 195.585(a(2 195.422(a 192.731(a 192.731(b 192.739 192.743 195.428 192.731(c 711 Inspect, Test, and Maintain Systems 192.731(c 195.408(b(1 195.408(b(1 712 Programmable Logic lers 192.731(c 195.408(b(1 195.428(a 713 Test/Maintain Gas Detection and Alarm Systems 192.736(c 714 Inspect and Maintain Pressure ing and Regulating Devices 715 Test and Maintain Pressure Switches and Transmitters in Pressure ing and Regulating Service 192.739 192.743(a 192.619(b 192.739 192.743(a 192.619(b 716 Inspect, Maintain, and Operate Valves 192.745 192.747 717 Maintaining Vaults With Pressure Regulating and Pressure ing Equipment 718 Monitoring for Internal Corrosion with Liquid Samples 192.477 192.620 195.428 195.428 195.420(a 195.420(b 192.749 195.579 723 Leakage Survey with Remote Laser Leak Detection Device 192.706 195.412(a 724 Permanent Field Repair Using Composite Materials (PipeWrap A+ / Atlas CFP 192.713 195.422( a 195.585(a(2 Certificate and Oral 725 Aerial Leakage Survey: Transmission 192.706 728 Aerial Leakage Survey: Transmission (UV/IR 192.706 762 Line Stopping Utilizing a Hot Tap Fitting 763 Squeeze Off Plastic Pipe 192.703(b 765 Inspection and Repair of Rupture Pin Devices 192.619(b 192.621(b 192.623 195.428 Yes 1:0 1 900 ROW Observance (Identifying Foreign Facilities 192.620(c(6 Oral 902 Field Bending of Pipe 192.313 Page 6 Copyright 2019. Veriforce, LLC. All rights reserved. Rev. 10

903 Directional Drilling and/or Boring 192.307 192.319 192.325 192.461 192.620(c(6 905 Lowering/Installation of Steel Pipe into Ditch 192.328(a 192.319 907 AC Mitigation 192.328(e 192.473(a 908 Installation of Cathodic Protection 192.453 192.620(c(6 910 Inspection of Construction Activities 192.305 192.620(c(6 921 Operate/Test/Maintain Sulfur (H2S Analyzers 192.620(d(5(iii 922 Operate/Test/Maintain Moisture Analyzers 192.620(d(5(iii 923 Operate/Test/Maintain Gas Chromatograph Analyzers 192.620(d(5(iii Oral 195.246 Oral NA NA NA Page 7 Copyright 2019. Veriforce, LLC. All rights reserved. Rev. 10