Instruction, Use and Maintenance Manual CONTROL UNITS GIOTTO TOP

Similar documents
Instruction, Use and Maintenance Manual CONTROL UNITS GIOTTO TOP

Instruction, Use and Maintenance Manual CONTROL UNITS J-GIOTTO TOP

USE AND MAINTENANCE INSTRUCTIONS. Giotto-Top GB-IST-GIOT-1113

USE AND MAINTENANCE MANUAL. J-Giotto-Top GB-IST-JGIOT-0112

USE AND MAINTENANCE INSTRUCTIONS. Giotto-Top GB-IST-GIOT-0112

Instruction, Use and Maintenance Manual BBZS5 - BBYS5

Instruction, Use and Maintenance Manual ASEPTIC PNEUMATIC ON-OFF VALVE WITH BELLOWS

Instruction, Use and Maintenance Manual HIGH-PRESSURE PNEUMATIC VALVE BBZQ - BBYQ

Instruction, Use and Maintenance Manual MODULATING VALVES BBZPM - BBYPM

MIXPROOF Valve B925 - B925B

By-pass valve BBZS1 - BBYS1

INSTRUCTION MANUAL. MIXPROOF ZAW Valve GB-IST-ZAW-0312

BBZP Pneumatic Valve BBZR Long Stroke Pneumatic Valve BBZT Pneumatic Valve

MIXPROOF Valve B925 - B925B

VERYIMPOR TANT VALVE

CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080

Mod: KLD6-12/35XLAS-N

Tina 4A Connection block

MV Series Motors Operation & Parts Manual

TM SERIES MIXER TMS OPERATION & PARTS MANUAL

Tina 11A Connection block

TBP SERIES PUMPS OPERATION & PARTS MANUAL

EU TOY DIRECTIVE 2009/48/EC: OVERVIEW - REGULATORY CONTEXT AND MAJOR CHANGES

EF SERIES MOTORS OPERATION & PARTS MANUAL

CETOP POSITION PAPER PP 07

Instruction Manual. Ex-Time 40 / 50

StormPro BA Series Sump Pump

Rig Master Power by Mobile Thermo Systems Inc.

INTERNATIONAL WARRANTY PROCEDURE. AUTOCLIMA S.p.A. PG-01-05

Instruction Manual. ThinkTop D30 ESE02248-EN Patented Sensor System Registered Design Registered Trademark. Original manual _1

Printed: Doc-Nr: PUB / / 000 / 00

TB SERIES PUMPS TBS OPERATION & PARTS MANUAL

EF SERIES PUMPS OPERATION & PARTS MANUAL

Tina 10A/B/C Adaptor unit

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

StormPro BCV400 Sewage Ejector Pump

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

BYD B-Box Limited Warranty Letter

BMRX Series ROTARY LEVEL CONTROL

The information in this instruction manual is subject to modifications without prior notice and is the exclusive property of Zorzini.

Installation / Operation Instructions Sunnex ORION Series Exam Lights

AC 100. Operating instructions Pneumatic Crimper AC 100. Date of issue: 05/2010. Keep for future use!

Duris E5 PowerFlex LED Strips 7.5mm LED Pitch

EStrong-series Emergency Stop

END USER TERMS OF USE

DALI 650mA LED Driver

These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800

APCO ASR-400/450 SEWAGE AIR RELEASE VALVES

AIR CHAMP PRODUCTS. User Manual. Sheave & Pilot Mount Clutch-Brake Model BCB-275 FORM NO. L F-0414 FORM NO. L F-0414

Operating instructions

Automatic concealed bollards 275 H600 and 275 H800 with pit

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 07.15

Duris E5 PowerFlex LED Strips 7.5mm LED Pitch

Tension Meter. Edition FT 03.E. FT Series. Instruction Manual. Valid as of: Please keep the manual for future reference!

UNI EN ISO EN

A Member of the. Integrated Metering Technologies

Rotary Limit Switches Driver FRS Series

WELDING INVERTER. PEGAS 160 E Smart PEGAS 200 E Smart OPERATING MANUAL. ALFA IN a.s. PEGAS E Smart Manual EN 04

A Member of the. Integrated Metering Technologies

Translation of the Original operating instructions Lifting device Z 70 /...

TSLC 6 UV LED 24v Strips

Rotary Limit Switches Driver FRM Series

Installation manual ASTER AUTOMATION FOR SWING GATES 11_16

Operation Key D4BS - K Head Mounting Direction F: Four mounting directions possible (front-side mounting at shipping)

Battery Charger User Manual

Type MZ15. Operating Instructions. Bedienungsanleitung Manuel d utilisation

Operator Instructions for Tension Links

VAPORIX-PCM. Technical Documentation. Corrective control module for connection to VAPORIX-Control. Version: 3 Edition: Art.

MICRO SWITCH INSTALLATION SHEET

How to get started. with. Kongsberg XP Auto systems. Serial number: Please Read This First

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES

OFFICINE OROBICHE S.p.A. 1/7 INSTRUCTION MANUAL FOR FLOW SWITCHES PL SERIES

The MCS III system can only be assembled on Nolan helmets pre-set for N-Com.

PF SERIES PUMPS PFS OPERATION & PARTS MANUAL

PVI 60KW, PVI 82KW, PVI 95KW

FMC-1/2 Tina Muting unit

Sense7-series Non-contact coded safety switch

DeZURIK 2 20" BOS BUTTERFLY VALVES

Stanley 3J 1 PowerStar Whites

Scania Used Vehicle Extended Driveline Warranty

1000mA - 650mA Phase Dimmable LED Driver

650mA Phase Dimmable LED Driver

Harley Davidson FL Touring Current Xtreme

Dual Phase Extraction Inlet. Patent No Installation Manual. P/N Rev

PNEUMATIC PUMP Series

USER s MANUAL 1. GENERAL INFORMATION 2. PRODUCT IDENTIFICATION

Armon Edero. User manual

Automatic concealed bollards 275 H600 and 275 H800 Control station

OPERATING INSTRUCTIONS PLEASE READ CAREFULLY

USER INSTRUCTIONS FOR SLIDING DOORS

HST -LS Interlocking device (Translation of Original Manual)

2019 EMISSION WARRANTIES BiFuel Kit

Mod. SC Man09. Manual sliding door USER AND MAINTENANCE MANUAL

INSTRUCTION AND USE MANUAL

Operating instructions Solenoid interlock AZM 161../.. 1. About this document. Content

Fifth Wheel Power Hitch Operations Manual

INSTALLATION, SERVICE AND MAINTENANCE INSTRUCTIONS Y-FILTER 83700

INSTALLATION, SERVICE AND MAINTENANCE INSTRUCTIONS Y-FILTER 83700

OSLONeye Powerstar LED Modules

Transcription:

CONTROL UNITS GIOTTO TOP Bardiani Valvole S.p.A. via G. di Vittorio, 50/52-43045 Fornovo di Taro (PR) - Italy tel. +39 0525 - Fax 0525 3408 bardiani@bardiani.com - www.bardiani.com

MANUAL REVISION DATE 2

INDEX 1 Safety,Warning and Mandatory Signs 5 2 General safety warnings 6 3 Technical Data 8 4 Giotto Top Control unit 9 5 Giotto Top Assembly / Disassembly 10 6 Giotto Top Installation 14 7 Giotto Top Pneumatic connections 17 8 Giotto Top Electrical connections 20 9 Troubleshooting 23 10 Maintenance and Cleaning 24 11 Ce Certificate 25 12 Warranty 26 13 Recommendations 27 3

INTRODUCTION This has been drawn up expressly for expert technical personnel. Consequently any information which can easily be deducted from reading the text and/or examining the illustrations and/or drawings provided herein shall not be the object of further explanation. It forms an integral part of the Products supplied and must be read prior to any installation, operation and/or maintenance of all types of control unit provided. This manual must be saved for future reference and be kept readily available at the unit. With regards to the use of valves compliant with EU Directive 2014/34/UE (ATEX), consultation of a specific manual is mandatory. The essential characteristics of all types of control unit described herein being consistent, the Manufacturer reserves the right to alter and or complement and or update at any time and with no obligation to notify so in writing, the data and or information relevant to the use of the control unit described in this "". A constantly updated version of this "" is available at the Manufacturer's website www.bardianivalvole.it. Under no circumstance shall the Manufacturer be held liable for consequences resulting from failure and or improper use of the instructions contained in this Manual and relating to the installation, operating, maintenance and storage of the products. All rights reserved. Full or part reproduction, transfer and or recording of any part of this "Instruction, Use and Maintenance Manual" by all means, whether it be electronic, on hard copy, mechanical or any other means or recording or reuse is strictly prohibited without the prior written consent of the Manufacturer and for any use other than that of the Buyer. (Translation of the Original Instructions in the italian Language) 4

1 Safety,Warning and Mandatory Signs SIGNALS Pictogram Description Notes WARNING! General This tells the person in question that the operation described involves (when not performed in accordance with the relative safety regulations) the risk of personal injury. OBLIGATION General PERSONAL PERSONNEL Special instructions must be followed to avoid injury to persons. Dismantling/Assembling and maintenance operations must be carried out by expert technicians only. NOTE Follow the indicated note with care ELECTRICAL CONNECTION Electrical connection to the control unit ELECTRICAL DISCONNECTION Electrical disconnection from the control unit PNEUMATIC CONNECTION Compressed air connection to the control unit PNEUMATIC DISCONNECTION Compressed air disconnection from the control unit 5

2 General safety warnings The control unit has been designed to control the pneumatically controlled process valves manufactured by Bardiani Valvole S.p.A.. It is possible to fit the Giotto Top with a maximum of three solenoid valves for controlling the process valve and up to a maximum of four inductive sensors, including an external one for controlling the position. For the electrical connections inside the control unit, there are three different configurations: LED terminal block and AS-i card: the LEDs indicate, in the presence of the relative inductive sensor, the status of the valve: green light = valve open; yellow light = valve closed; white light = bottom or top lift activated. 10-pole terminal block: no LEDs. General warnings Always read the technical data carefully before machine installation, operation and maintenance. The Giotto Top must always be installed, operated and maintained by authorized personnel. Said personnel must know and understand both the unit and the contents of the manual. Take care over any separate parts of the Giotto Top when removing it from its packaging. Always connect the air supply carefully and disconnect it after use. Always connect the power supply carefully and disconnect it after use. Never touch the moving parts in the Giotto Top or valves. Always handle detergents with care. Prohibited use Use of the control unit is not envisaged: for any operations other than those for which it was designed. WARNING The machine may not he used inside premises where there is a potentially explosive atmosphere or risk of fire unless otherwise stated by the manufacturer (in the case of valves certified in accordance with Directive 2014/34/EU please refer to the ATEX Manual). WARNING The control unit contains circuits classified as LOW VOLTAGE LIMITED ENERGY CIRCUIT. For correct use in North America dimension the protection circuits in accordance with Standard UL508A. 6

WARNING ALWAYS make sure the electrical and pneumatic connections are NOT active when executing operations on the Giotto Top and that the power supply voltage is only 24 Vdc. WARNING Under normal circumstance (exposure time, eye pupils, observation distance) it is assumed that no endangerment to the eye exists from the LEDs. As a matter of principle, however, it has to be mentioned that intense light sources have high secondary exposure potential due to their blinding effect. As is also true when viewing other bright light sources (e.g. headlights), temporary reduction in visual acuity and afterimages may occur, leading to irritation, annoyance, visual impairment, and even accidents, depending on the situation BARDIANI VALVOLE S.p.A. declines all liability for installation, use or maintenance which fails to comply with the indications provided in this manual! 7

3 Technical Data CONTROL UNIT TECHNICAL DATA Weight from 0.55 Kg to 0.65 Kg depending on the configuration Casing material PA66 + PA6-GF30 (glass fibre reinforced nylon) Gaskets material NBR Protection class IP67 Air supply and vent connections 1/8 BSP Air line connections 6 mm / 1/4 (ON REQUEST) Electrical connections 7-pole connector or M12 5- or 8-pole connector Threaded fitting for cable gland PG11 or M20x1.5 Field bus connections Actuator interface (AS-i). Vibrations 1mm amplitude f=10..55hz Storage temperature -25..+70 C Operating temperature -10...+50 C Air supply Class 2,4,3 according to ISO 8573-1 Single Acting Valves SOLENOID APPLICATION CRITERIA Double Acting Valves (1 normally open and 1 normally closed), Mixproof and Twin-Stop valves (2 normally closed) Mixproof valves with air supply for opening, top and bottom lift (3 normally closed) 1 Solenoid valve 2 Solenoid valves 3 Solenoid valves Electrical power supply Air pressure supply Electrical power supply SOLENOID TECHNICAL DATA 24 Vdc max. 7bar min. 6bar INDUCTIVE SENSOR TECHNICAL DATA 24 Vdc AS-i BOARD TECHNICAL DATA Inputs N / type 4 / PNP Output N / type 3 / PNP MAX current consumption 220 ma Total MAX current (IN+OUT) 150 ma AS-interface Profile S-7.A.7.F As-interface specification V 3.0 AS-interface IC ASI4U Extended addressing mode Type B solenoid valves Type S solenoid valves In the event of any doubt, please contact Bardiani Valvole S.p.A. ü ü ü 8

4 Giotto Top Control unit NO. DESCRIPTION 21 Base 21a Sealing ring 21b Sealing ring 21d Double guide 21e Vent plug 21f Air coupling 21g Air coupling 21i Cap 21k Terminal block with support 22 Cam 25 Screw 26 Bardiani case 27a 27d Micro-size inductive sensors holder slide 114a Sleeve for cable gland 114b 7-pole connector 114c 5-pole connector 114d 8-pole connector 192 Solenoid valve 192b Solenoid valve support 192c Cap 192d Solenoid valve board 192e Sealing ring 283 AS-i board 9

5 Giotto Top Assembly / Disassembly 21 114a 114c 114d 21f 21g 21i 21e 114b 21d 27d 27a 21 10

x 4 192b 192 x 5 192e 21 Solenoid valve sequence NC NC NO NO NO NO 192 11

192b x 2 192 192e x 5 21 Solenoid valve sequence NC NC NO NC NC NC NC NC NA NC NC NC 192 12

TYPE B - TYPE S 21k 21k 21 21 21k 21b 21 21 21a 13

6 Giotto Top Installation 1 22 2 114a 25 114b 114c 114d 3 4 26 WARNING Always make sure that all wires are connected and securely fastened to the terminals and that the solenoid valves, solenoid valves support, AS-i card and LED terminal block (when present) and any other parts inside the Giotto Top are well assembled and secured. WARNING Always make sure that the electrical and pneumatic connections are disconnected when carrying out operations on the Giotto Top. 14

External inductive sensor installation 1 2 Ø 12,5 мм 3 PG7 (M12x1,5) 4 Pages 13-16 5 Ø 1,5 мм 15

Cilynder configuration Normally closed Normally open closed open upper lift lower lift 16

7 Giotto Top Pneumatic connections 6 Compressed Air inlet 1/8 (BSP) Connections for air fitting 1/8 Air vent 1/8 (BSP) WARNING Use only pipes with an external diameter of 6 mm. Cut these pipes with a suitable cutter to avoid damaging the pipe which could lead to Giotto Top malfunctions. Select a suitable length of pipe which allows the Giotto Top to be removed without unscrewing the anchoring. 17

Valve with single acting actuator BBZP - BBYP - BBWP ZVF Valve with double acting actuator BBZP - BBYP - BBZQ ZVF 18

Valve with single acting actuator with Twin Stop BBZT Mixproof valve B925 - B935 19

8 Giotto Top Electrical connections 1,2 PNP sensors with 1,2,3 normally closed solenoid valves and 7-pole connector OPEN CLOSED Solenoid valve 1 Solenoid valve 2 CLOSED signal OPEN signal Solenoid valve 1 Solenoid valve 2 Solenoid valve 3 s PIN Connector (7) (6) (4) (3) (2) (1) (5) COLOR Wire (White) (Blue) (Brown) (Purple) (Black) (Red) (Gray) Solenoid valve 2 Solenoid valve 1 Solenoid valve 3 s signal OPEN signal CLOSED Solenoid valve 3 1,2 PNP sensors with 2 solenoid valves (1 N.C. and 1 N.O.) for double acting 7-pole connector OPEN CLOSED Solenoid valve 1 N.C. Solenoid valve 2 N.O. CLOSED signal OPEN signal Solenoid valves PIN Connector (1) (2) (7) (6) (4) (3) COLOR Wire (Red) (Black) (Blue) (White) (Brown) (Purple) Solenoid valves s s (5) (Gray) signal OPEN signal CLOSED 1,2 PNP sensors with 1 normally closed solenoid valves and 5-pole connector OPEN CLOSED Solenoid valve CLOSED signal OPEN signal Solenoid valve PIN Connector (2) (4) (3) (5) COLOR Wire (White) (Black) (Blue) (Gray) signal OPEN s (1) (Brown) s signal CLOSED Solenoid valve 1,2 PNP sensors with 2 solenoid valves (1 N.C. and 1 N.O.) for double acting 5-pole connector OPEN CLOSED Solenoid valve 1 N.C. Solenoid valve 2 N.O. CLOSED signal OPEN signal Solenoid valves PIN Connector (2) (4) (3) (5) COLOR Wire (White) (Black) (Blue) (Gray) signal OPEN s (1) (Brown) s signal CLOSED Solenoid valves 20

1,2,3 PNP sensors with 1,2,3 normally closed solenoid valves and 8-pole connector OPEN CLOSED Solenoid valve 1 Solenoid valve 2 UPPER LIFT signal CLOSED signal OPEN signal Solenoid valve 1 Solenoid valve 2 Solenoid valve 3 s PIN Connector (8) (1) (6) (7) (5) (3) (4) (2) COLOR Wire (Red) (White) (Pink) (Blue) (Gray) (Green) (Yellow) (Brown) signal OPEN signal CLOSED Solenoid valve 1 External signal UPPER LIFT Solenoid valve 3 Solenoid valve 2 s UPPER LIFT (external) (brown) signal (black) Solenoid valve 3 1,2,3 PNP sensors with 1,2,3 normally closed solenoid valves and 8-pole connector OPEN CLOSED LOWER LIFT Solenoid valve 1 Solenoid valve 2 LOWER LIFT signal CLOSED signal OPEN signal Solenoid valve 1 Solenoid valve 2 Solenoid valve 3 s PIN Connector (8) (1) (6) (7) (5) (3) (4) (2) COLOR Wire (Red) (White) (Pink) (Blue) (Gray) (Green) (Yellow) (Brown) signal OPEN Solenoid valve 1 Solenoid valve 2 Solenoid valve 3 s signal CLOSED signal LOWER LIFT Solenoid valve 3 1,2,3,4 PNP sensors with 1,2,3 normally closed solenoid valves OPEN CLOSED LOWER LIFT Solenoid valve 1 Solenoid valve 2 UPPER LIFT signal LOWER LIFT signal CLOSED signal OPEN signal Solenoid valve 1 Solenoid valve 2 Solenoid valve 3 s (brown) UPPER LIFT (external) signal (black) Solenoid valve 3 1,2 PNP sensors with 2 solenoid valves (1 N.C. and 1 N.O.) for double acting OPEN CLOSED Solenoid valve 1 Solenoid valve 2 UPPER LIFT signal LOWER LIFT signal CLOSED signal OPEN signal Solenoid valves s 21

AS-i 360 Board 1,2,3,4 PNP sensors with 1,2,3 normally closed solenoid valves OPEN (DI0) CLOSED (DI1) LOWER LIFT (DI3) AS-i - (Blue) AS-i + (Brown) UPPER LIFT (DI2) AS-i Network Solenoid valve 1 (DO0) Solenoid valve 2 (DO1) Solenoid valve 3 (DO2) AS-i 360 Board 1,2 PNP sensors with 2 solenoid valves (1 N.C. and 1 N.O.) for double acting OPEN (DI0) CLOSED (DI1) LOWER LIFT (DI3) AS-i - (Blue) AS-i + (Brown) UPPER LIFT (DI2) AS-i Network Solenoid valve 1 (DO0) Solenoid valve 2 (DO1) 1,2,3 normally closed solenoid valves and 7-pole connector Solenoid valve 3 (Red) Solenoid valve 2 (Red) Solenoid valve 1 (Red) Solenoid valve 3 (Black) Solenoid valve 2 (Black) Solenoid valve 1 (Black) HIGH (Blue) LOW (Blue) HIGH (Brown) LOW (Brown) HIGH signal (Black) LOW signal (Black) Solenoid valve 3 Solenoid valve 2 Solenoid valve 1 s HIGH signal LOW signal PIN Connector (1) (2) (3) (4) (5) (6) (7) COLOR Wire (Red) (Black) (Purple) (Brown) (Gray) (White) (Blue) Solenoid valve 1 Solenoid valve 2 Solenoid valve 3 signal LOW +24V Senso sign HIGH 1,2,3 normally closed solenoid valves and 5-pole connector Solenoid valve (Red) Solenoid valve (Black) HIGH (Blue) LOW (Blue) HIGH (Brown) LOW (Brown) HIGH signal (Black) LOW signal (Black) Solenoid valve s HIGH signal LOW signal PIN Connector (5) (3) (1) (4) (2) COLOR Wire (Gray) (Blue) (Brown) (Black) (White) signal HIGH s Solenoid valve sig LOW 22

9 Troubleshooting PROBLEM POSSIBLE CAUSE POSSIBLE SOLUTION Air leak from solenoid valve support Air leaks in safety valve The LED do not come on The solenoid valve does not activate The inductive sensors are not working No gaskets or loose fitting Circuit board damaged Damaged LEDs Inductive sensors not working Damaged solenoid valve Circuit board damaged Air supply pressure incorrect Solenoid valve support damaged Electrical connections not made properly Inductive sensors damaged Electrical connections not made properly Distance between the cam and the inductive sensors greater than 1.5 mm. Check the sealing capacity of the gaskets and tighten the screws Replace the circuit board Check the sensor connections in the terminal block and restore if necessary Replace solenoid valve Replace the circuit board Consult the Technical Data section in the Manual Replace solenoid valve support Check the connections in the terminal block on the electrical board and tighten the screws. Replace inductive sensors Check the connections in the terminal block on the electrical board and tighten the screws. Check the centring of the Giotto and the fastening to the double guide 23

10 Maintenance and Cleaning When used correctly the Giotto Top does not need any special maintenance. Any repair work must be carried out by authorized personnel only, making sure that the electrical and pneumatic power supplies have been disconnected before carrying out any operation inside the Giotto Top. WARNING Before using cleaning products make sure they are compatible with the materials used to construct the Giotto Top, both the casing and the gaskets. If solvents or cleaning agents containing acids or alkaline substances are used, always make sure the Giotto Top is immediately rinsed with clean water. When so doing, pay particular attention to those areas where there are orifices or openings. WARNING Each time the casing is open, make sure that the various cables inside it are repositioned where they do not interfere with cam movement. WARNING Should it be necessary to replace any component of the Giotto Top, contact Bardiani Valvole S.p.A. to purchase the necessary spare part as the use of any products not supplied by us may compromise correct valve operation or constitute a hazard for personnel. 24

11 Ce Certificate GB - EC Declaration of conformity - A3-P-PRG-GB EC DECLARATION OF CONFORMITY OF THE MACHINERY (EC) 2006/42, Annex. II, p. 1 A BARDIANI VALVOLE S.p.A. Via G. di Vittorio 50/52 43045 Fornovo di Taro (Pr) Italy Declares under its own responsibility that the machine: Type: PNEUMATIC S Model: Serial number: Function: Fluid handling Year of construction: 2016 Reference complies with all relevant provisions of the following EC directives: (EC) 2006/42 MACHINERY and also comply with the following EC Directives and Regulations: (EU) 2014/30 ELECTROMAGNETIC COMPATIBILITY DIRECTIVE (EMC) and the following harmonized standards, rules and / or technical specifications applied: EN ISO 12100:2010 REGULATION (EC) 1935/2004 and subsequent amendments and additions with regard to steel and elastomers in contact with the product REGULATION (EC) 10/2011 and subsequent amendments and additions with regard to PTFE in contact with the product FACSIMILE Fornovo di Taro 10/10/2016 Emanuela Bardiani Legal representative A3-P-PRG-GB Ed. 1. Rev. 0 BARDIANI VALVOLE S.p.A.. Via G. di Vittorio 50/52 43045 Fornovo di Taro (Pr) 25

12 Warranty 1. VALIDITY Bardiani Valvole s Products are manufactured in compliance with the technical specifications laid out in their and are fully compliant with the directives specifically mentioned in these manuals. Bardiani Valvole S.p.A. guarantees its own Products against any design and/or construction and/or material defects and/or faults for a period of 12 (twelve) months from the date of delivery. Notification of any Product defects and/or faults must be sent in writing to Bardiani Valvole S.p.A. within 8 (eight) days from their detection, providing adequate documentation of the defect/fault encountered as evidence. Services provided in the warranty period shall not result in an extension of the warranty beyond the stipulated 12 (twelve)-month period, as this warranty validity period is to be considered mandatory. 2. CONTENTS OF THE WARRANTY Notwithstanding and without prejudice to the rights of the Buyer, which may be acknowledged by applicable law, this warranty it to be intended as limited, at the discretion of Bardiani Valvole S.p.A., to the repair and/or replacement of the Product and/or part of the Product and/or its components which is/are found to be defective due to design and/or manufacturing and/or material faults. In the event of repair and/or replacement of the Product and/or any one of its parts and/or components, any returned item/s shall become the property of Bardiani Valvole S.p.A. and the relative shipping costs shall charged to Bardiani Valvole S.p.A. Bardiani Valvole S.p.A., shall be under no obligation to compensate for any immaterial and/or indirect damages and shall in no way be held liable for consequential damages and/or losses, such as (by way of example only), damages due to loss of business, contracts, opportunities, time, production, profits, goodwill, image etc. No retailer or distributor or dealer or agent or representative or employee or person appointed by Bardiani Valvole S.p.A. is authorized to make any amendments and/or integrations and/or extensions to this warranty. 3. WARRANTY EXCLUSIONS -- Elastomers and electrical components are expressly excluded from this warranty. -- This warranty does not cover design faults emerging whenever a Product is manufactured by Bardiani Valvole S.p.A. based on designs and/or technical specifications provided by the Buyer. -- Moreover this warranty excludes the following: -- faults and/or defects resulting from incorrect and/or unsuitable and/or inadequate transportation of the Product; -- faults and/or defects resulting from failure to comply with the indications laid out in the Instruction, Use and Maintenance Manual with regards to installation of the Product or in any event caused by incorrect and/or unsuitable and/or improper installation; -- faults and/or defects resulting from failure to comply with indications laid out in the Instruction, Use and Maintenance Manual with regards to use and/or maintenance operations and/or storage of the Product or in any event caused by incorrect and/or unsuitable and/or improper use and/or maintenance operations and/or storage; -- faults and/or defects due to normal wear and tear of the Product and/or its parts and/or its components; -- faults and/or defects in the Product and/or its parts and/or its components for work and/or repairs being carried out by unskilled staff or staff that has not been authorised by Bardiani Valvole S.p.A.; -- faults and/or defects in the Product and/or its parts and/or its components caused by its being dropped and/or banged and/or dented and/or misused and/or tampering and/or breakage and/or accidents and/or any other event caused by negligence and/or carelessness and/or neglect by the Buyer and in general for any causes not ascribable to design and/or manufacturing and/or material defects; -- faults and/or defects in the Product and/or its parts and/or its components caused by other events beyond the control of Bardiani Valvole S.p.A., such as force majeure or unforseeable circumstances. 26

13 Recommendations 1.Consultation of the " is mandatory prior to the installation, use and maintenance of the products of all Products. All the information, indications, specifications, technical details provided herein are based on test data which the Manufacturer Bardiani Valvole S.p.A. holds to be reliable nevertheless the above is not deemed to be assumed as fully exhaustive inasmuch as not every possible use has been envisaged. 2.All the illustrations and drawings provided are to be intended as indicative and therefore not binding, the Products illustrations being for presentation purposes only. 3.It is the Buyer's duty to assess the suitability of the products for the use he intends to make of the same prior to placing the order as he/she will take the risks and accept liability in case of incorrect choice and use of the Products. 4.The Manufacturer strongly recommends the Buyer to contact their sales team and request any information that might be needed in relation to the specifications and uses of the Products. 5.The information provided in this manual refers to the standard products manufactured by Bardiani Valvole S.p.A. and therefore cannot be assumed to apply to customized products as well. 6.Bardiani Valvole S.p.A. reserves the right to amend and/or integrate and/or update the data and/ or information and/or technical details relative to Products at any time and without prior notice. Please visit the website www.bardiani.com, where the latest updated of the "Instruction, Use and Maintenance Manual" can be found". 7.The content and validity of the warranty covering the Products of Bardiani Valvole S.p.A are dealt with in the relevant section in the which constitutes an integral part of the Products themselves. 8.Bardiani Valvole S.p.A., shall not in any way be held liable for immaterial, indirect and consequential damages, such as (by way of example only), damages or loss of business, contracts, opportunities, time, production, profits, goodwill, image etc.. 27

NOTES 28

NOTES 29

Bardiani Valvole S.p.A. via G. di Vittorio, 50/52-43045 Fornovo di Taro (PR) - Italy tel. +39 0525 - Fax 0525 3408 bardiani@bardiani.com - www.bardiani.com