Tests Report Nº B2014 LACUS IN 11 TG B Laboratory measurements of airborne sound insulation

Similar documents
Evidence of performance Reduction of impact sound pressure level by floor coverings

LABORATORY MEASUREMENTS OF THE REDUCTION OF TRANSMITTED IMPACT NOISE PANETTI OVERLAID BY LAMINATED FLOORING

CLIP-IN SILENCE. Glass partition and door system for acoustic insulation SYSTEMS

Evidence of Performance Airborne sound insulation of flat roofs

series RVV Variable flow rate controllers

Nº B26-14-CW-01E 4/LE148. SOFAMEL C/Tomas Edisson, Polígono industrial Plans de Arau La Pobla de Claramunt (Barcelona)

RIVERBANK ACOUSTICAL LABORATORIES

Steel Door Sound Transmission Tests

EMC Research Institute

MFPA Leipzig GmbH Test, monitoring and certification point for building materials, products and systems

Sound-absorbing spacer Sorp10

Sound transmission across plenum windows with non-parallel glass panes

series Silencers

WHITE PAPER. Flow Induced Noise Reduction Techniques for Microphones in Low Speed Wind Tunnels

Title: Fire Resistance Test In Accordance With BS EN : 1999 On A Glazed Screen Assembly. WF Report No: , Issue 2. Prepared for: Date:

Noise Resist. - you need to improve the noise reduction of your existing sound enclosure

BPF. Centrifugal Plug Fans

TECHNICAL SPECIFICATIONS. AD Retarder. OC442068/a 11/2000 1

New Technologies and Fuels Promotion in the Basque Country

Report Number BTC 12261F

Experimental investigation of high airflow rate ventilation system with improved noise performance by passive and active means

BS EN :2006. Windows and doors Product standard, performance characteristics. A Report To: Mila Hardware Ltd. Document Reference:

Combinations. Monolithic Glass: Standard thickness: 4mm and 6mm Substrate: SGG PLANILUX clear float. Toughened Glass:

TESTING LABORATORY FOR CIVIL ENGINEERING MATERIALS

Adelaide Wind Power Project Turbine T05 (AD117) IEC Edition 3.0 Measurement Report

Engineering Data Manual. New : available with EC motor. High Static Pressure Ductable Fan Coil Unit. Models 07 to to 4650 m 3 /h

Ingeteam Power Technology S.A. - Energy Avenida Ciudad De La Innovación, Sarriguren. Navarra. SPAIN

CASE STUDY. A World Leader in a Niche Market. PAPST Fans Testing and Development of Automotive Fans. Germany. Automotive, Industrial, Consumer

CER. Product Certificate Number Applicant

BS EN ISO :2006

INFOSHEET DATASHEET SONIC CLASSIC WALL SYSTEM. Measurement method. Test TNO Cepro Sonic Classic in accordance with EN-ISO 140-3

RE / STAR Tolerance Rings STAR Ball Knobs, Knob and Lever Type Handles

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. QC/T Translated English of Chinese Standard: QC/T

Acoustic design of the air transparent soundproofing wall

The complex analysis of tram noise in relation to changes in dynamic mobility of tram wheel

Report Number BTC 12024F

EU Mutual Recognition Technical Requirements

ROTT test on Novus Sealing "Uniflon 50" gasket

Product description. Glass of this type is commonly known as low emissivity glass, or low- E glass. Were can it be used?

GM Specification Annual Test Data

Multideck 60-V2. Contents

ATZAF DOUBLE INLET CENTRIFUGAL FANS WITH AIRFOIL BACKWARD CURVED BLADES

F LEXIBLE DUCT VERSIONS

LED STRIPS, PROFILES AND ACCESSORIES

ISO INTERNATIONAL STANDARD. Measurement of noise emitted by accelerating road vehicles Engineering method Part 2: L category

GENERAL EXPLANATION ABOUT CLASSIFICATIONS

CASE STUDY. History. Liebherr-Werk Ehingen GmbH EU Directive Compliance, R& D Testing. Germany. Automotive. PULSE, Transducers

Technical Information

Test report. The above described product sample is tested to measure his power performance

WF Report No: Prepared for: Rohden UK Ltd Unit 2, Hayleys Manor Farm Upland Road, Epping Upland, Essex, CM16 6PQ. Date: Notified Body No:

MECCANICA ECOLOGIA CERAMICA ALIMENTARE. Modena, 28/08/17 To FLORIM CERAMICHE SPA VIA CANALETTO FIORANO MODENESE MO. Attn. SIG. TURRINI D.

Test Report No

PERFORMANCE TEST REPORT. Rendered to: AIR VENT, INC. SERIES/MODEL: Hip Ridge Vent PRODUCT TYPE: Ridge Vent

Alberta Innovates - Technology Futures ~ Fuels & Lubricants

Rated voltage: 100~277 VAC Frequency: 50/60Hz Wattage: 14 W

Contact person RISE Date Reference Page. Fredrik Öberg P02435B 1 (5) Building Technology

Pressure control damper ERPA

ADD: Room New Victory House, Wing Lok Street, Central, HONG KONG

Testing of Baier Plasterboard to AS/NZS (Electronic copy (PDF format) original signed by author) Materials Scientist.

Acoustical Benefits of Plenum Window as Facade Device A Parametric Study

TECHNICAL SPECIFICATIONS

CASE STUDY. 50 Years of Technological Innovation. Blachford Inc. Automotive NVH Testing. United States of America. Automotive

Report No: Test of: Reversible aluminium/timber window. Tested to: BS :2009 Performance of windows & doors Part 2: Operation & strength

People - Ideas - Solutions

PVHRU Max Quiet. Engineering Solutions. Packaged Void Heat Reclaim Unit. Acoustic Testing Laboratory College of Science & Technology

Content - Silencers. Silencers for spiral systems. Silencers for rectangular systems

APMP TCAUV Workshop The application of acoustics, vibration and ultrasound metrology in transportation industry

Mufflers. Absorptive, Reactive, Reactive Lined, Reactive Side Entry, Reactive Side Entry Lined

NFRC U-FACTOR, SHGC, VT, & CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: PARAMOUNT WINDOWS

DL /118 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT VERSION SUBPLATE MOUNTING ISO p max 280 bar Q max 50 l/min

Circular Silencer. Rigid and flexible construction Type CA CB CF CS. TROX GmbH Telephone +49/28 45/ Telefax +49/28 45/

Planning Manual Beauty Angel CVT 32. Beauty Angel CVT 32. Contents

BHW MEDIUM STATIC PRESSURE DUCTABLE TYPE TECHNICAL CATALOGUE

A quiet poroelastic road surface manufactured in a normal asphalt mixing plant

OPS Master Plan for Spanish Ports Project. Study of potential acoustic benefits of on-shore power supply at berth

ISO INTERNATIONAL STANDARD. Measurement of noise emitted by accelerating road vehicles Engineering method Part 2: L category

series KFD-KLD Linear slot diffusers

European Fire Pump Listing

People - Ideas - Solutions Marine

GM Specification Annual Test Data

ASTM E 1354 Caloric Content Determination of "3M Polyurethane Adhesive Sealant 540"

WINDER. Impellers with higher efficiency and less sound level

High Accuracy Bunker Blending / Bunker Control

Sample Description: Six (6) pairs of white nylon seamless knitted lining with acrylonitrile butadiene coating Standard : BS EN 420: 2003+A1: 2009

ANSI/AHRI Standard 880 (I-P) 2011 Standard for Performance Rating of Air Terminals

Ride-on lawnmowers (combustion engine powered)

The application of microperforated material to control axial fan noise

High Accuracy Bunker Blending / Bunker Control

BUSSMANN. Pre-production and sample electric vehicle power fuses 500 Vdc, A SERIES. Technical Data Effective December 2018.

Pistonphone Type 42AP

NFRC U-FACTOR, SHGC / VT, CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: EARTHWISE GROUP, L.L.C.

Rehabilitated PCC Surface Characteristics

NFRC U-FACTOR, SHGC / VT, CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: EARTHWISE GROUP, L.L.C. SERIES/MODEL: SS 145.

Method Implementation Document (MID)

FIPRO Fire Protection Panels For Shipbuilding and Offshore Interior Applications

NFRC U-FACTOR, SHGC / VT, CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: EARTHWISE GROUP, L.L.C.

Federal Railroad Administration, DOT CFR section Description Guideline PART 179

This document is a preview generated by EVS

Guidelines for the Noise Measurement of Homebuilt Aircraft

Sigma 2-7. Benchtop centrifuge.

Transcription:

EMPLEGU ETA GIZARTE POLITIKETAKO SAILA Etxebizitza, Zuzendaritza DEPARTAMENTO DE EMPLEO Y POLÍTICAS SOCIALES Dirección de Vivienda Tests Report Nº B2014 LACUS IN 11 TG B Laboratory measurements of airborne sound insulation AKUSTIKA ARLOA kudeatzailea: ACOUSTICS AREA managed by: TESTS SPECIMENS: 7 Saint Gobain Glazing Partition Systems with tesa ACX plus 7058. APPLICANT: SAINT GOBAIN GLASSOLUTIONS SAINT GOBAIN GLASS France 18 avenue d Alsace 92400 Courbevoie France PERSON OF CONTACT: Jean Francois Outin. TESTS STANDARD: EN ISO 10140 2:2010. DATES OF TESTS: 3 rd, 6 th, 7 th, 9 th, 17 th and 21 st October, 2014. 18 th November, 2014. DATE OF THE TESTS REPORT: 17 th December, 2014. Signature María José de Rozas López Acoustics Laboratory Manager The technical owned of the ENAC Nº4/LE456 accreditation fall to Fundación Tecnalia Research & Innovation, the same way as the technical signature of this report. The installations where are performed the measurements according ENAC Nº4/LE456 accreditation belong to the Acoustics Area of Laboratory for Quality Control in Buildings of the Basque Country Government. Notified Laboratory Nº 1292 for acoustic testing. THIS REPORT CONTAINS: Total number of pages: 26 + (4 of ANNEX A). 4 / L E 4 5 6 This document includes only and exclusively the tested specimens and the moment and conditions in which those measurements were made. It is expressly forbidden any total or partial reproduction of this document, except with a written conformity from TECNALIA. The test specimens have been subjected to the test asked by the applicant, following the specified procedures in the used standards. Test results are detailed in the inside pages. Uncertainties of measurements complies the recommendations of EN 20140 2:1994 and they are available to the applicant. This document is a copy in PDF of the original Report, for request of our client. Page 1 of 26 (+ Annex A)

INDEX 1. AIM... Page 2 2. DESCRIPTION OF TEST SPECIMENS... Page 3 3. RESULTS... Page 19 ANNEX A: Test arrangements and evaluation. 1. AIM This report presents the results of the laboratory measurements of airborne sound insulation of 7 Saint Gobain Glazing Partition Systems with tesa ACX plus 7058. The test specimens were selected and delivered by Tesa SE and Saint Gobain Glassolutions. The installation and sealing of the specimens into the test opening was made by Cristalería BELAGUA, S.L. under supervision of personnel of TECNALIA. Each test specimen stayed 24 hours in the same temperature conditions than the test rooms. The tests were performed by personnel of TECNALIA (Construction Area Technological Services Division) in the acoustics facilities of the Laboratory for Quality Control in Buildings of the Basque Country Government, located at Aguirrelanda, Nº 10, 01013 Vitoria Gasteiz (Alava Spain). The details of the test arrangements and test evaluation are described in Annex A. Report Nº B2014 LACUS IN 11 TG B Page 2 of 26 (+ Annex A)

2. DESCRIPTION OF TESTS SPECIMENS This report presents the acoustic results of the following tested specimens: TEST SPECIMEN Code Test Code: B2014 11 Description: Saint Gobain Glazing Partition Systems with tesa ACX plus 7058 acrylic core tape. Type of Glass/glasses Material between glass units Framework: Type of profiles and other components Details in Drawing Nº I M150 SGG Stadip 66.1 tesa ACX plus 7058 Click 25 aluminium 1 II M151 SGG Planilux 12mm toughened tesa ACX plus 7058 profiles 2 (Reynaers) III M152 SGG Planilux 10mm toughened tesa ACX plus 7058 3 IV M153 Double Skin: SGG Stadip 66.1 + SGG Stadip 55.1 tesa ACX plus 7058 Double Click 25 aluminium profiles (Reynaers) 4 V M161 Double Skin: SGG Stadip Silence 66.1 + SGG Stadip Silence 55.2 tesa ACX plus 7058 Double Click 25 aluminium profiles (Reynaers) 5 VI M185 SGG Stadip Silence 66.1 tesa ACX plus 7058 Click 25 aluminium profiles (Reynaers) 6 VII M154 Double Skin SGG Planilux 10mm + SGG Stadip Silence 55.2 tesa ACX plus 7058 Double profile Clipper (Coramine) 7 Table 1: Test specimens Specimens were mounted into a concrete frame 20 cm thick, with interior nominal dimensions of 2800 mm of height and 3600 mm of length. Report Nº B2014 LACUS IN 11 TG B Page 3 of 26 (+ Annex A)

1 2 Ref. B C D F G PROFILE Saint Gobain Glassolutions Clip in Light System Click 25 contra 4674.17 ALU Click 25 10 12mm 4674.17 ALU Click 25 glasrubber 10 12 17mm ZWART Click 25 spierubber 12 17mm ZWART Self adhesive tape polyethylene foam(close cell) 25x3mm Drawing 1: Test specimen I. Details Report Nº B2014 LACUS IN 11 TG B Page 4 of 26 (+ Annex A)

Photo 1 Photo 2 Photo 3 Photo 5 Photo 4 Photo 6 Photo 7 Photos 1 7: Test specimen I in acoustic rooms and details of installation Report Nº B2014 LACUS IN 11 TG B Page 5 of 26 (+ Annex A)

1 2 Ref. B C D F G PROFILE Saint Gobain Glassolutions Clip in Light System Click 25 contra 4674.17 ALU Click 25 10 12mm 4674.17 ALU Click 25 glasrubber 10 12 17mm ZWART Click 25 spierubber 12 17mm ZWART Self adhesive tape polyethylene foam(close cell) 25x3mm Drawing 2: Test specimen II. Details Report Nº B2014 LACUS IN 11 TG B Page 6 of 26 (+ Annex A)

Photo 8 Photo 9 Photo 11 Photo 10 Photo 12 Photo 13 Photos 8 13: Test specimen II in acoustic rooms and details of installation Report Nº B2014 LACUS IN 11 TG B Page 7 of 26 (+ Annex A)

1 2 Ref. B C D E G PROFILE Saint Gobain Glassolutions Clip in Light System Click 25 contra 4674.17 ALU Click 25 10 12mm 4674.17 ALU Click 25 glasrubber 10 12 17mm ZWART Click 25 spierubber 10mm ZWART Self adhesive tape polyethylene foam(close cell) 25x3mm Drawing 3: Test specimen III. Details Report Nº B2014 LACUS IN 11 TG B Page 8 of 26 (+ Annex A)

Photo 14 Photo 15 Photo 16 Photo 17 Photo 18 Photo 19 Photos 14 19: Test specimen III in acoustic rooms and details of installation Report Nº B2014 LACUS IN 11 TG B Page 9 of 26 (+ Annex A)

1 2 Ref. A B C D E F G PROFILE Saint Gobain Glassolutions Clip in Light System Click 25 double 10 12mm 100mm EV 1 Click 25 contra 4674.17 ALU Click 25 10 12mm 4674.17 ALU Click 25 glasrubber 10 12 17mm ZWART Click 25 spierubber 10mm ZWART Click 25 spierubber 12 17mm ZWART Self adhesive tape polyethylene foam(close cell) 25x3mm Drawing 4: Test specimen IV. Details Report Nº B2014 LACUS IN 11 TG B Page 10 of 26 (+ Annex A)

Photo 20 Photo 21 Photo 22 Photo 23 Photo 24 Photo 25 Photos 20 25: Test specimen IV in acoustic rooms and details of installation Report Nº B2014 LACUS IN 11 TG B Page 11 of 26 (+ Annex A)

Ref. A Ref. B Ref. D Ref. C Ref. E Ref. G Ref. F Figure 1: details of materials for test specimens (I to VI) Tesa ACXplus 7058 (6mm) Report Nº B2014 LACUS IN 11 TG B Page 12 of 26 (+ Annex A)

1 2 Ref. A B C D E F G PROFILE Saint Gobain Glassolutions Clip in Light System Click 25 double 10 12mm 100mm EV 1 Click 25 contra 4674.17 ALU Click 25 10 12mm 4674.17 ALU Click 25 glasrubber 10 12 17mm ZWART Click 25 spierubber 10mm ZWART Click 25 spierubber 12 17mm ZWART Self adhesive tape polyethylene foam(close cell) 25x3mm Drawing 5: Test specimen V. Details Report Nº B2014 LACUS IN 11 TG B Page 13 of 26 (+ Annex A)

Photo 36 Photo 28 Photo 29 Photo 27 Photo 30 Photo 31 Photos 26 31: Test specimen V in acoustic rooms and details of installation Report Nº B2014 LACUS IN 11 TG B Page 14 of 26 (+ Annex A)

1 2 Ref. B C D F G PROFILE Saint Gobain Glassolutions Clip in Light System Click 25 contra 4674.17 ALU Click 25 10 12mm 4674.17 ALU Click 25 glasrubber 10 12 17mm ZWART Click 25 spierubber 12 17mm ZWART Self adhesive tape polyethylene foam(close cell) 25x3mm Drawing 6: Test specimen VI. Details Report Nº B2014 LACUS IN 11 TG B Page 15 of 26 (+ Annex A)

Photo 32 Photo 33 Photo 34 Photo 35 Photo 36 Photo 38 Photo 37 Photos 32 38: Test specimen VI in acoustic rooms and details of installation Report Nº B2014 LACUS IN 11 TG B Page 16 of 26 (+ Annex A)

B B-B A 2788 B 3596 A-A 1 Flat cover strip Ref: 5 7900 9 Double glazing Ref: 5 1500 2 tesa ACX plus 7058 (6mm) 10 Upright Ref: 5 1350 3 Channel Ref: 5 7100 11 Clips S Ref: 1 020 4 Separator Ref: 1 030 12 Retaining gasket Ref: 9 840 5 Acoustic foam for channel Ref: 9 600 13 Glazing gasket Ref: 9 980 6 Acoustic foam for upright Ref: 9 620 14 Shim 7 Knock in Screw 15 Glass SGG STADIP 55.2 Silice 8 Glass SGG Planilux 10 mm Drawing 7: Test specimen VII. Details Report Nº B2014 LACUS IN 11 TG B Page 17 of 26 (+ Annex A)

Photo 40 Photo 39 Photo 41 Photo 42 Photo 44 Photo 43 Report Nº B2014 LACUS IN 11 TG B Page 18 of 26 (+ Annex A)

Photo 45 Photos 39 45: Test specimen VII in acoustic rooms and details of installation 3. RESULTS For each test sample, the following airborne sound insulation results are featured: Sound reduction index, R, in third octave frequency bands from 100 to 5000 Hz, in table and graph. The Weighted sound reduction index, R w, calculated according to EN ISO 717 1, from the sound reduction index, R. The spectrum adaptation terms between 100 and 3150 Hz, C and C tr, calculated according to EN ISO 717 1, which are the values, expressed in decibels, to be added to the global magnitude value (R w, for example) to consider the characteristics of a particular noise spectrum, such as pink noise (C) and traffic noise (C tr ). Report Nº B2014 LACUS IN 11 TG B Page 19 of 26 (+ Annex A)

EMPLEGU ETA GIZARTE POLITIKETAKO SAILA Etxebizitza Zuzendaritza Eraikuntzaren Kalitate Kontrolerako Laborategia DEPARTAMENTO DE EMPLEO Y POLÍTICAS SOCIALES Dirección de Vivienda Laboratorio de Control de Calidad de la Edificación Airborne Sound Insulation according to EN ISO 10140 2:2010 (*) Laboratory Measurements Applicant: SAINT GOBAIN GLASSOLUTIONS. Test date: October 3 rd, 2.014. Test specimen: Saint Gobain Glass Solution Clip in Light System with SGG Stadip 66.1 and tesa ACX plus 7058. Receiving room volume: 56,26 m 3 Source room volume: 65,50 m 3 Estimated superficial mass: 30 kg/m 2 Test specimen area: 10,08 m 2 (2,8x3,6 m) T rooms: 19,7 ºC HR rooms: 64 % P rooms: 964 mbar R (db) f (Hz) R (db) 100 22,8 125 22,0 160 26,3 200 28,2 250 28,5 315 31,5 400 33,0 500 33,2 630 34,2 800 33,9 1000 29,1 1250 28,2 1600 33,2 2000 37,7 2500 41,3 3150 45,1 4000 48,0 5000 51,5 Sound reduction index R (db) 50 40 30 20 10 100 125 Curve of reference values for the evaluation of the weighted sound reduction Index, Rw 34 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 Frequencies (Hz) 4000 5000 Rating according to EN ISO 717 1: R w (C;C tr ): 34 ( 2; 3) db Evaluation based on laboratory measurement results obtained by an engineering method. 4 / L E 4 5 6 (*) It annuls, replaces and complies with cancelled standard norme EN ISO 140 3:1995 Nº of result: B2014 11 M150 Signature: Acoustics Area Managed by Date of report: 17 th December, 2.014. Report Nº B2014 LACUS IN 11 TG B Page 20 of 26 (+ Annex A)

EMPLEGU ETA GIZARTE POLITIKETAKO SAILA Etxebizitza Zuzendaritza Eraikuntzaren Kalitate Kontrolerako Laborategia DEPARTAMENTO DE EMPLEO Y POLÍTICAS SOCIALES Dirección de Vivienda Laboratorio de Control de Calidad de la Edificación Airborne Sound Insulation according to EN ISO 10140 2:2010 (*) Laboratory Measurements Applicant: SAINT GOBAIN GLASSOLUTIONS. Test date: 6 th October, 2.014. Test specimen: Saint Gobain Glass Solution Clip in Light System with SGG Planilux 12mm toughened and tesa ACX plus 7058. Receiving room volume: 56,26 m 3 Source room volume: 65,50 m 3 Estimated superficial mass: 30 kg/m 2 Test specimen area: 10,08 m 2 (2,8x3,6 m) T rooms: 19,6 ºC HR rooms: 65 % P rooms: 953 mbar f (Hz) R (db) 100 22,2 125 23,7 160 26,7 200 28,3 250 28,7 315 30,8 400 33,3 500 33,8 630 34,6 800 33,3 1000 26,2 1250 26,4 1600 31,3 2000 35,6 2500 38,5 3150 41,6 4000 44,6 5000 45,8 Sound reduction index R (db) 50 40 30 20 10 100 125 R (db) Curve of reference values for the evaluation of the weighted sound reduction Index, Rw 33 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 Frequencies (Hz) 4000 5000 Rating according to EN ISO 717 1: R w (C;C tr ): 33 ( 2; 4) db Evaluation based on laboratory measurement results obtained by an engineering method. 4 / L E 4 5 6 (*) It annuls, replaces and complies with cancelled standard norme EN ISO 140 3:1995 Nº of result: B2014 11 M151 Signature: Acoustics Area Managed by Date of report: 17 th December, 2.014. Report Nº B2014 LACUS IN 11 TG B Page 21 of 26 (+ Annex A)

EMPLEGU ETA GIZARTE POLITIKETAKO SAILA Etxebizitza Zuzendaritza Eraikuntzaren Kalitate Kontrolerako Laborategia DEPARTAMENTO DE EMPLEO Y POLÍTICAS SOCIALES Dirección de Vivienda Laboratorio de Control de Calidad de la Edificación Airborne Sound Insulation according to EN ISO 10140 2:2010 (*) Laboratory Measurements Applicant: SAINT GOBAIN GLASSOLUTIONS. Test date: 7 th October, 2.014. Test specimen: Saint Gobain Glass Solution Clip in Light System with SGG Planilux 10mm toughened and tesa ACX plus 7058. Receiving room volume: 56,26 m 3 Source room volume: 65,50 m 3 Estimated superficial mass: 25 kg/m 2 Test specimen area: 10,08 m 2 (2,8x3,6 m) T rooms: 19,5 ºC HR rooms: 64 % P rooms: 951 mbar R (db) f (Hz) R (db) 100 21,9 125 21,0 160 24,9 200 26,4 250 27,7 315 30,1 400 31,1 500 32,5 630 33,7 800 34,2 1000 33,5 1250 23,9 1600 26,7 2000 32,3 2500 35,3 3150 38,9 4000 42,3 5000 43,6 Sound reduction index R (db) 50 40 30 20 10 100 125 Curve of reference values for the evaluation of the weighted sound reduction Index, Rw 32 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 Frequencies (Hz) 4000 5000 Rating according to EN ISO 717 1: R w (C;C tr ): 32 ( 3; 3) db Evaluation based on laboratory measurement results obtained by an engineering method. 4 / L E 4 5 6 (*) It annuls, replaces and complies with cancelled standard norme EN ISO 140 3:1995 Nº of result: B2014 11 M152 Signature: Acoustics Area Managed by Date of report: 17 th December, 2.014. Report Nº B2014 LACUS IN 11 TG B Page 22 of 26 (+ Annex A)

EMPLEGU ETA GIZARTE POLITIKETAKO SAILA Etxebizitza Zuzendaritza Eraikuntzaren Kalitate Kontrolerako Laborategia DEPARTAMENTO DE EMPLEO Y POLÍTICAS SOCIALES Dirección de Vivienda Laboratorio de Control de Calidad de la Edificación Airborne Sound Insulation according to EN ISO 10140 2:2010 (*) Laboratory Measurements Applicant: SAINT GOBAIN GLASSOLUTIONS. Test date: 9 th October, 2.014. Test specimen: Saint Gobain Glass Solution Clip in Light System with SGG Stadip 66.1 / SGG Stadip 55.1 and tesa ACX plus 7058. Receiving room volume: 55,50 m 3 Estimated superficial mass: 55 kg/m 2 T rooms: 19,6 ºC P rooms: 951 mbar Source room volume: 65,50 m 3 Test specimen area: 10,08 m 2 (2,8x3,6 m) HR rooms: 68 % 70 R (db) Curve of reference values for the evaluation of the weighted sound reduction Index, Rw 60 f (Hz) R (db) 100 26,4 125 24,8 160 29,1 200 31,2 250 30,0 315 33,4 400 35,9 500 38,5 630 40,5 800 42,4 1000 40,7 1250 39,5 1600 45,1 2000 51,9 2500 59,3 3150 61,4 4000 66,9 5000 74,1 Sound reduction index R (db) 50 40 30 20 100 125 160 41 200 250 315 400 500 630 800 1000 1250 1600 Frequencies (Hz) 2000 2500 3150 4000 5000 Rating according to EN ISO 717 1: R w (C;C tr ): 41 ( 1; 4) db Evaluation based on laboratory measurement results obtained by an engineering method. 4 / L E 4 5 6 (*) It annuls, replaces and complies with cancelled standard norme EN ISO 140 3:1995 Nº of result: B2014 11 M153 Signature: Acoustics Area Managed by Date of report: 17 th December, 2.014. Report Nº B2014 LACUS IN 11 TG B Page 23 of 26 (+ Annex A)

EMPLEGU ETA GIZARTE POLITIKETAKO SAILA Etxebizitza Zuzendaritza Eraikuntzaren Kalitate Kontrolerako Laborategia DEPARTAMENTO DE EMPLEO Y POLÍTICAS SOCIALES Dirección de Vivienda Laboratorio de Control de Calidad de la Edificación Airborne Sound Insulation according to EN ISO 10140 2:2010 (*) Laboratory Measurements Applicant: SAINT GOBAIN GLASSOLUTIONS. Test date: 21 st October 2.014. Test specimen: Saint Gobain Glass Solution Clip in Light System with SGG Stadip Silence 66.1 / SGG Stadip Silence 55.2 and tesa ACX plus 7058. Receiving room volume: 55,50 m 3 Source room volume: 65,50 m 3 Estimated superficial mass: 55 kg/m 2 Test specimen area: 10,08 m 2 (2,8x3,6 m) T rooms: 19,7 ºC HR rooms: 56 % P rooms: 964 mbar R (db) 70 Curve of reference values for the evaluation of the weighted sound reduction Index, Rw f (Hz) R (db) 100 27,1 125 25,5 160 28,2 200 30,4 250 30,0 315 33,1 400 36,0 500 38,9 630 41,9 800 46,3 1000 49,7 1250 52,6 1600 54,6 2000 57,7 2500 63,5 3150 66,0 4000 68,2 5000 73,2 Sound reduction index R (db) 60 50 40 30 20 100 125 160 200 250 315 43 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000 Frequencies (Hz) Rating according to EN ISO 717 1: R w (C;C tr ): 43 ( 1; 5) db Evaluation based on laboratory measurement results obtained by an engineering method. (*) It annuls, replaces and complies with cancelled standard norme EN ISO 140 3:1995 Nº of result: B2014 11 M161 Signature: Acoustics Area Managed Date of report: 17 th December, 2.014. 4 / L E 4 5 6 Report Nº B2014 LACUS IN 11 TG B Page 24 of 26 (+ Annex A)

EMPLEGU ETA GIZARTE POLITIKETAKO SAILA Etxebizitza Zuzendaritza Eraikuntzaren Kalitate Kontrolerako Laborategia DEPARTAMENTO DE EMPLEO Y POLÍTICAS SOCIALES Dirección de Vivienda Laboratorio de Control de Calidad de la Edificación Airborne Sound Insulation according to EN ISO 10140 2:2010 (*) Laboratory Measurements Applicant: SAINT GOBAIN GLASSOLUTIONS. Test date: 18 th November, 2.014. Test specimen: Saint Gobain Glass Solution Clip in Light System with SGG Stadip Silence 66.1 and tesa ACX plus 7058. Receiving room volume: 56,26 m 3 Estimated superficial mass: 30 kg/m 2 T rooms: 20,0 ºC P rooms: 950 mbar Source room volume: 65,50 m 3 Test specimen area: 10,08 m 2 (2,8x3,6 m) HR rooms: 43 % 60 R (db) 50 Curve of reference values for the evaluation of the weighted sound reduction Index, Rw f (Hz) R (db) 100 23,9 125 23,4 160 27,1 200 28,5 250 28,9 315 31,6 400 33,0 500 34,4 630 36,0 800 36,9 1000 37,9 1250 38,3 1600 37,8 2000 39,1 2500 43,1 3150 47,3 4000 50,2 5000 54,0 Sound reduction index R (db) 40 30 20 10 100 125 160 200 37 250 315 400 500 630 800 1000 Frequencies (Hz) 1250 1600 2000 2500 3150 4000 5000 Rating according to EN ISO 717 1: R w (C;C tr ): 37 (0; 3) db Evaluation based on laboratory measurement results obtained by an engineering method. 4 / L E 4 5 6 (*) It annuls, replaces and complies with cancelled standard norme EN ISO 140 3:1995 Nº of result: B2014 11 M185 Signature: Acoustics Area Managed by Date of report: 17 th December, 2.014. Report Nº B2014 LACUS IN 11 TG B Page 25 of 26 (+ Annex A)

EMPLEGU ETA GIZARTE POLITIKETAKO SAILA Etxebizitza Zuzendaritza Eraikuntzaren Kalitate Kontrolerako Laborategia DEPARTAMENTO DE EMPLEO Y POLÍTICAS SOCIALES Dirección de Vivienda Laboratorio de Control de Calidad de la Edificación Airborne Sound Insulation according to EN ISO 10140 2:2010 (*) Laboratory Measurements Applicant: SAINT GOBAIN GLASSOLUTIONS. Test date: 17 th October, 2.014. Test specimen: Saint Gobain Glass Solution Clip in Light System (Coramine) with SGG Planilux 10mm / SGG Stadip Silence 55.2 and tesa ACX plus 7058. A-A Receiving room volume: 55,60 m 3 Source room volume: 65,60 m 3 Estimated superficial mass: 50 kg/m 2 Test specimen area: 10,08 m 2 (2,8x3,6 m) T rooms: 19,2 ºC HR rooms: 62 % P rooms: 957 mbar 55 R (db) Curve of reference values for the evaluation of the weighted sound reduction Index, Rw f (Hz) R (db) 100 25,4 125 20,9 160 22,3 200 25,2 250 25,8 315 30,7 400 33,6 500 35,3 630 37,3 800 37,7 1000 37,7 1250 35,5 1600 36,7 2000 40,9 2500 42,9 3150 47,7 4000 50,0 5000 53,2 Sound reduction index R (db) 45 35 25 15 100 125 160 200 37 250 315 400 500 630 800 1000 Frequencies (Hz) 1250 1600 2000 2500 3150 4000 5000 Rating according to EN ISO 717 1: R w (C;C tr ): 37 ( 1; 5) db Evaluation based on laboratory measurement results obtained by an engineering method. 4 / L E 4 5 6 (*) It annuls, replaces and complies with cancelled standard norme EN ISO 140 3:1995 Nº of result: B2014 11 M154 Signature: Acoustics Area Managed by Date of report: 17 th December, 2.014. Report Nº B2014 LACUS IN 11 TG B Page 26 of 26 (+ Annex A)

Annex A - Test arrangements and evaluation A.1 Test standards and procedures EN ISO 10140 2:2010: Acoustics. Laboratory measurement of sound insulation for building elements. Measurement of airborne insulation. EN ISO 717 1:2013: Rating of sound insulation in buildings and of building elements. Airborne sound insulation. TECNALIA internal procedures. According to ENAC accreditation No 4/LE456 (ENAC: Spanish National Accreditation Body). Standard EN ISO 10140 2:2010, together with the other EN ISO 10140 1:2010, EN ISO 10140 3:2010, EN ISO 10140 4:2010 and EN ISO 10140 5:2010, cancels and replaces standard EN ISO 140 3:1994. A.2 Laboratory test facilities The sound insulation tests were performed in the horizontal transmission rooms, composed of a source and a receiving room. The reception room is composed of a double concrete box of twenty and ten centimetres of thickness each one, acoustically disconnected. The horizontal transmission rooms comply with the requirements of the EN ISO 10140 5:2010. A sketch of each room is included in Drawing 1. Annex A to Report Nº B2014 LACUS IN 11 TG B Page 1 of 4

Drawing 1: Sketch of the horizontal transmission rooms A.3 Equipment Source room Receiving room Microphones Brüel & Kjær 4943; Nº 2534064 Brüel & Kjær 4943; Nº 2534065 Preamplifiers Brüel & Kjær 2669; Nº 1948764 Brüel & Kjær 2669; Nº 2025844 Sound sources Brüel & Kjær 4296; Nº 2071420 CERWIN VEGA; Nº 012446 Booms Brüel & Kjær 3923; Nº 2036586 Brüel & Kjær 3923; Nº 2036591 Control room Analyser Brüel & Kjær 2144; Nº 1893979 Amplifier LAB Gruppen;LAB 300; Nº 970 967 Equalizer Sony, SRP E100; Nº 400238 Calibrator Brüel & Kjær 4231; Nº 2061476 Atmospheric conditions meter Ahlborn Almemo 2590 3S; Nº H09121017 Annex A to Report Nº B2014 LACUS IN 11 TG B Page 2 of 4

A.4 Test procedures The sound reduction index (R) for the one third octave band 100 Hz to 5 KHz is calculated according to EN ISO 10140 2 standard using the following formula: R=L 1 L 2 +10 Log S/A where, L 1 : Average sound pressure level in the source room. L 2 : Average sound pressure level in the receiving room. S: Test specimen area. A: Equivalent sound absorption area in the receiving room. The measurement of the average sound pressure levels L 1 and L 2 is performed emitting an equalized white noise (between 100 Hz and 5 khz) with a moving omnidirectional sound source. The sound field in the source and receiving rooms is sampled using moving microphone with a sweep radius of 1 m and a traverse period of 16 s during 32 s of measure. Background noise is measured in the receiving room in the one third octave band 100 Hz to 5 khz according to the same measurement process of sound field in the receiving room. The equivalent sound absorption area is evaluated from the reverberation time measured in the receiving room, using Sabine s formula: A=0.16 V/T where, A: Equivalent sound absorption area in the receiving room. T: Reverberation time in the receiving room. V: Receiving room volume. Reverberation time in the receiving room is determined using two positions of the sound source and three fixed microphone positions for each source position, at 120º in the microphone path. Measuring instruments are verified just before and after the execution of the test. Annex A to Report Nº B2014 LACUS IN 11 TG B Page 3 of 4

The measurement and evaluation process applied to the test specimen described in this report is according to the standard in force EN ISO 10140 2:2010, and complies with cancelled standard EN ISO 140 3:1994. Annex A to Report Nº B2014 LACUS IN 11 TG B Page 4 of 4