DAMPERS WE CONTROL AIR

Similar documents
INDEX. Chapter1 6. air master. Volume Control Dampers

Model VCD-18. Ratings. Blade Operation. Size Limitations. Features & Options

WE GUIDE AIR LOUVERS

VCD-23. Flange Options. Size Limitations

VCD-23 Low Leakage CONTROL DAMPER

Baked Enamel, Epoxy, Hi Pro Polyester, Industrial Epoxy, Kynar/Hylar (70%) Permatector. Single or Reverse Flange 8 x 6 (203 x 178)

Model VCD-40. Extruded Airfoil Blade Control Damper Narrowline Frame Construction. Application. Ratings. Flange Options.

VCD-23. Low Leakage CONTROL DAMPER

AMD-33 Air Measuring Station with VCD-33 Control Damper

SMOKE DAMPER - CLASS F MODEL BMSD

AMD-33. Air Measuring Station with VCD-33 Control Damper. Application and Design. Features & Control Options

Model VCD-20. Control Damper. Application. 3V Blade. Ratings. Flange Options. Size Limitations. Blade Operation. Features and Options

SafidDampers SPK Standard Construction SPK Description SPK ( Flange Type )

COMBINATION FIRE/SMOKE DAMPER - CLASS F MODEL BMFSD (3 HR) / MODEL BEMFSD (1½ HR)

Thermal Isolation Break. Frame Type Channel Quick Connect Single or Reverse Flange Blade Action Parallel Opposed Parallel Opposed Parallel Opposed

SafidDampers SPK Description. Standard Construction SPK ( Flange Type )

DAMPERS FOR COMMERCIAL & INDUSTRIAL APPLICATIONS IN HEATING, VENTILATING & AIR CONDITIONING

AMD-42V Air Measuring Station with VCD-42V Control Damper

AMD-42 Air Measuring Station with VCD-42 Control Damper

Model VCD-43 Extruded Airfoil Blade Control Damper

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x 305) 5 in. (127mm) Parallel

Model VCD-34. Low Leakage Insulated Airfoil CONTROL DAMPER. Ratings (See page 3 for specific limitations) Flange Options.

Insulated Control Damper. 12 x 7 (305 x 178) 8 x 7 (203 x 178)

Model VCD-20 3V CONTROL DAMPER

Model VCD-33. Low Leakage Airfoil CONTROL DAMPER. Flange Options. Blade Operation. Size Limitations

Thermal Isolation. Break

BC 09. Pressure Relief Dampers PRD-GAB-12B LISTED

Model SEVCD-33. Low Leakage Airfoil Control Damper. Application and Design. Ratings (See page 3 for specific limitations) Blade Operation

AL-Maraj Central A/C Systems Accessories Mfg Co.

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x in. W x 120 in. H (3658mm x 3048mm) 5 in.

CONTROL DAMPERS. Model Model 1370CB. Model 1380CB. Model 1390CB B7

Control Dampers. Leakage Performance. Model FDNB (Opposed Blade) FDQB (Parallel Blade) Galvanized 3V Blade Control Dampers

AMD-23-TD. Thermal Dispersion Air Measuring Station with VCD-23 Control Damper. Application. Ratings. Features and Options

CONTROL DAMPERS. Models 1810 & Model Model Model 1370

Model SMD-302M. Modulating Smoke Damper. Application. Steel Airfoil Blades UL 555S Leakage Class II. Ratings. Size Limitations.

AMD-42-TD. Thermal Dispersion Air Measuring Station with VCD-42 Control Damper. Application and Design. Ratings. Features and Control Options

Model DFD-230 Multi-Blade Fire Damper Steel 3V Blades UL555 3 Hour Fire Resistance Rating

VCD-43V. Vertical Airfoil Blade Control Damper. Application and Design. Ratings. Size Limitations. Features and Options: Pressure:

HCD-230 Industrial Control Damper

Model CFSD-211. Corridor Ceiling FIRE SMOKE DAMPER Steel 3V Blades UL 555S Leakage Class I

Control Dampers and Fire Dampers. Volume 1 - March Insulated Control Dampers. Non-Insulated Control Dampers. Framing. Accessories.

FBV-43. Vertical Face & Bypass Control Damper Ultra Low Leakage Aluminum Frame Construction. Application and Design. Size Limitations.

TED50XT EXTREME TEMPERATURE THERMALLY EFFICIENT, INSULATED BLADE DAMPER

ARROW INDUSTRIAL PRODUCTS

HCD-135. Industrial Control Damper. Application and Design. Ratings (see page 2 and 3 for specific limitations) Standard Construction.

Model FSD-212. Combination FIRE SMOKE DAMPERS

When Time is Everything... We Manufacture in Days - Not Weeks!

MOTORIZED VOLUME DAMPER

AIRODYNE CATALOGUE VOLUME CONTROL TAMPERS CONSTRUCTION / MATERIALS

ARROW UNITED INDUSTRIES

Model VCD-20V. 3V Vertical Control Damper. Application and Design. Ratings (See page 4 for specific limitations) Flange Options.

SMD-201M. Application. Modulating Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations.

Positive Seal Damper Blades with Vinyl Gaskets 2.5" SERIES 3000 SIDE MOUNT - NO FLANGE ORDERING METHOD FOR BACKDRAFT & MOTORIZED BACKDRAFT DAMPERS

WD-300 Series. Backdraft Damper Vertical Mount - Horizontal Airflow. Application and Design. Ratings. Frame Styles. Size Limitations.

Model FSD-211. Application. Combination Fire Smoke Damper Steel 3V Blades UL 555S Leakage Class I UL /2 Hour Fire Resistance Rating.

Model SMD-301. Smoke Damper Steel Airfoil Blades UL 555S Leakage Class I. Application. Ratings. Size Limitations. Features

Model FSD-331. Combination Fire Smoke Dampers. Application. Ratings. Features

EX C E L L E N C E ISO 9001 CERTIFIED COMPANY LINEAR BAR GRILLES.

Model FSD-331 Combination Fire Smoke Dampers

Dampers. Louvers. Caring for Human Life & Property (FIRE, SMOKE & HVAC) NAFFCOFlow.com

Series HCD Airfoil Control Damper

STATIONARY LOUVERS STATIONARY LOUVERS STATIONARY LOUVERS

SMD-201. Application. Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations.

LOW LEAKAGE VOLUME CONTROL DAMPER

VOLUME CONTROL & SHUT OFF DAMPERS SERIES 400

HVAC Control & Balancing Dampers

PC-125x Counter-Balanced Backdraft Damper

PRODUCTS BULLETIN PRODUCTS CATALOGUE

WD-200 Series. Model WD-220 Flange Opposite Motor. Model WD-210 Flange on Motor Side. Model WD-200 No Flange. Motorized Backdraft Damper.

Model SSFSD-211. Combination Fire Smoke Damper 304 Stainless Steel 3V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating

SP Standard Profile. In Duct or Flanged to Duct Install Types OPPOSED ACTION PARALLEL ACTION. Extended Rear Flange Install Type

Motorized Fire Dampers

INDEX. Chapter3. air master. Linear Bar Grilles

AMCA MEMBER. American Warming and Ventilating. A Mestek Company. Quality Air Control Dampers

FSD60/MFSD60 Multi-blade Fire Damper

SMOKE DAMPERS SMOKE DAMPERS SMOKE DAMPERS

Model FSD-211. Combination FIRE SMOKE DAMPERS Steel 3-V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating

EXHAUST AND AIR LOUVERS CHAPTER 5

Multileaf damper with actuator

ID-141x 12-Gauge Hat Channel Industrial Damper

A. Product Data: For each type of product. TLC ENGINEERING FOR ARCHITECTURE - PROJECT NO AIR DUCT ACCESSORIES

INDEX. Chapter2. air master. Grilles and Registers

AIR CONDITIONING PRODUCTS COMPANY

BD-1600 Balancing/Zone Control Damper

Air Measuring Products AMD AMS IAQ

XeteX, Inc. All Rights Reserved.

VOLUME CONTROL DAMPER

FSD36, FSD36LP COMBINATION FIRE AND SMOKE DAMPER 1 1 /2 HOUR UL555 RATED, UL555S LEAKAGE CLASS 2

L O U V E R S & D A M P E R S

VOLUME CONTROL DAMPERS

Air Louvers OFAL 300 SERIES

Inside Front cover White

SV-UNOBOX FAN. Mutassim Al-Daour factory for Metal Industries SV-7

FSD60, FSD60LP CoMBINAtIoN FIRe AND SMoKe DAMPeR

INDEX. SUPER VENT By Beta Industrial. pages INTRODUCTION CONSTRUCTION PERFORMANCE CHART ACOUSTIC DATA CHART DIMENSION SHEET - SINGLE CABINET FANS

HVAC Control & Balancing Dampers

CONTROL & BACKDRAFT DAMPERS. Nailor. Industries Inc.

VD-1600 Series Volume Control Dampers

Blast Protection Damper

VC Series. Volume Control Dampers M A N U F A C T U R E R S O F A I R, F I R E A N D S M O K E C O N T R O L P R O D U C T S

Transcription:

WE CONTROL AIR Ver. 1 January 2017

index >> VOLUME CONTROL DAMPER - 3VCD SERIES >> VOLUME CONTROL DAMPER - AVCD SERIES >> LOW-LEAKAGE VOLUME CONTROL DAMPER - LVCD SERIES >> ROUND VOLUME CONTROL DAMPER - VDR SERIES >> BACK DRAFT DAMPER - NRD SERIES >> BACK DRAFT DAMPER - PRD SERIES >> ACCESS DOORS ACC2L, ACCH, ACCPHLK 1-4 5-7 8-10 11-13 14-15 16-17 18-19 Note: AMCA certified products are available at AMCA directory of listed products at http://www.amca.org/certified-listed/listedproducts.php

VOLUME CONTROL DAMPER 3VCD SERIES VOLUME CONTROL DAMPER - 3VCD SERIES 3V-SHAPED STEEL S STANDARD CONSTRUCTION Frame: 1.2mm thick galvanized steel sheet. Model 3VCDG2PLF Blades: 3 V-shaped 1.2mm thick roll-formed galvanized steel. Axles: ½ square galvanized steel rod. Linkage: made of galvanized steel. Concealed in frame. Bushing: Self lubricating plastic bushes. Quadrant: Plated steel with wing nut to lock the blades position. Marked to show the position of the blades. Fixing to duct: Flanged frame. Model 3VCDG2PLH Size: Single section up to: 1200X1200mm for Hat-shaped/flanged types. 1000X1000mm for slip & clip/box types. DIMENSIONS 133 10 210 192.4 180 20.0 133 133 25 10 10 25 23.2 Plastic Bushes 3VCD-Flange type 3VCD-Slip & Clip type 3VCD-Box type 3VCD-Hat type 3VCD with gear mechanism 1

VOLUME CONTROL DAMPER 3VCD SERIES VOLUME CONTROL DAMPER - 3VCD SERIES 3V-SHAPED STEEL S OPTIONS MANUAL QUADRANT MODELS FEATURE MODEL 3VCDG2PLH 3VCDG2BLH 3VCDG2PLF 3VCDG2BLF 3VCDG2PLS 3VCDG2BLS 3VCDG2PLB 3VCDG2BLB 3VCDG2PGH 3VCDG2BGH 3VCDG2PGF 3VCDG2BGF 3VCDG2PGS 3VCDG2BGS 3VCDG2PGB 3VCDG2BGB 3VCDS2SLH 3VCDS2SLF 3VCDS2SLS 3VCDS2BLB 3VCDS2SGH 3VCDS2SGF 3VCDS2SGS 3VCDS2SGB 3VCDG2-SMC 3VCDS2-SMC DRIVE MOVEMENT USE CONSTRUCTION BUSHING/ BEARING MECHANISM FIXING TO DUCT MANUAL QUADRANT ELECTRIC ACTUATOR G.I. 3V-SHAPED ALUMINUM AEROFOIL OPPOSED PARALLEL ABOVE MODELS (EXCEPT THE ONES WITH GEAR MECHANISM) CAN BE WITH PARALLEL S, PLS. WRITE PARALLEL ON YOUR ORDER CONTROL (AIR BALANCING) LOW LEAKAGE (AIR TIGHT SHUT OFF) GALVANIZED STEEL STAINLESS STEEL 304 PLASTIC BUSHES BRASS BUSHES S.S. BEARING G.I. LINKAGE PLASTIC GEARS HAT-SHAPED FLANGE SLIP & CLIP BOX (INSERTED INSIDE DUCT) **Other options of S.S. bushes "X" and S.S. bearing "S" are shown at the ordering key. MOTORIZED MODELS FEATURE MODEL M3VCDG2PLH M3VCDG2BLH M3VCDG2PLF M3VCDG2BLF M3VCDG2PLS M3VCDG2BLS M3VCDG2PLB M3VCDG2BLB M3VCDG2PGH M3VCDG2BGH M3VCDG2PGF M3VCDG2BGF M3VCDG2PGS M3VCDG2BGS M3VCDG2PGB M3VCDG2BGB M3VCDS2SLH M3VCDS2SLF M3VCDS2SLS M3VCDS2BLB M3VCDS2SGH M3VCDS2SGF M3VCDS2SGS M3VCDS2SGB M3VCDG2-SMC M3VCDS2-SMC DRIVE MOVEMENT USE CONSTRUCTION BUSHING/ BEARING MECHANISM FIXING TO DUCT MANUAL QUADRANT ELECTRIC ACTUATOR G.I. 3V-SHAPED ALUMINUM AEROFOIL OPPOSED PARALLEL ABOVE MODELS (EXCEPT THE ONES WITH GEAR MECHANISM) CAN BE WITH PARALLEL S, PLS. WRITE PARALLEL ON YOUR ORDER CONTROL (AIR BALANCING) LOW LEAKAGE (AIR TIGHT SHUT OFF) GALVANIZED STEEL STAINLESS STEEL 304 PLASTIC BUSHES BRASS BUSHES S.S. BEARING G.I. LINKAGE PLASTIC GEARS HAT-SHAPED FLANGE SLIP & CLIP BOX (INSERTED INSIDE DUCT) **Other options of S.S. bushes "X" and S.S. bearing "S" are shown at the ordering key. 2

VOLUME CONTROL DAMPER 3VCD SERIES VOLUME CONTROL DAMPER - 3VCD SERIES 3V-SHAPED STEEL S PERFORMANCE DATA Beta Industrial LLC certifies that the 3VCD shown hereon is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to Air Leakage and Air Performance ratings only. Test Information * Air leakage is based on operation between 32 F and 120 F * Tested for air leakage at standard air density in accordance with ANSI/AMCA Standard 500-D, Figure 5.4 * Tested for air performance at standard air density in accordance with ANSI/AMCA 500-D, Figure 5.3 * Data are based on a torque of 21 in-lb/ft2 applied to close and seat the damper during the test. PRESSURE DROP DATA AIR LEAKAGE DATA Bulletin No. 8, January 2017 3

VOLUME CONTROL DAMPER 3VCD SERIES VOLUME CONTROL DAMPER - 3VCD SERIES 3V-SHAPED STEEL S PERFORMANCE DATA FLANGED HAT-SHAPED SLIP & CLIP BOX Ordering Key: M 3 VCD G2 P L F SIZE - - : QUADRANT DRIVED M: MOTORIZED 3: 3V-SHAPED G.I. S VCD: VOLUME CONTROL DAMPER G1: 0.9MM G.I.CONSTRUCTION G2: 1.2MM G.I.CONSTRUCTION G3: 1.5MM G.I.CONSTRUCTION G4: 1.7MM G.I.CONSTRUCTION S1: 1.0MM S.S. 304 CONSTRUCTION S2: 1.2MM S.S. 304 CONSTRUCTION S3 1.5MM S.S. 304 CONSTRUCTION S4: 1.7MM S.S. 304 CONSTRUCTION P: PLASTIC BUSHES B: BRASS BUSHES X: S.S. BUSHES S: S.S. BEARINGS L: G.I. LINKAGE MECHANISM G: PLASTIC GEARS MECHANISM H: HAT-SHAPED FRAME F: FLANGED TO DUCT S: SLIP & CLIP WITH DUCT B: BOX (INSERTED INSIDE DUCT) SIZE: WIDTH X HEIGHT Single section up to: 1200X1200mm for flanged types/ Hat-Shaped 1000X1000mm for slip & clip / box types. 4

VOLUME CONTROL DAMPER AVCD SERIES VOLUME CONTROL DAMPER - AVCD SERIES AEROFOIL ALUMINUM S STANDARD CONSTRUCTION Frame: 1.2mm thick galvanized steel sheet. Blades: Aerofoil 1.0mm double skin extruded Aluminum profiles. Axles: ½ square galvanized steel rod. Linkage: Made of galvanized steel. Concealed in frame. Bushing: Self lubricating plastic bushes. Quadrant: Plated steel with wing nut to lock the blades position. Marked to show the position of the blades. Fixing to duct: Flanged frame. Size: Single section up to: 1200X1200mm for hat-shaped / flanged types. 1000X1000mm for slip & clip / box types. Model AVCDG2PLF Model MAVCDG2PLF BOX S&C FLANGED HAT-SHAPE DIMENSIONS 133 10 210 192.4 180 20.0 133 133 25 10 10 23.2 25 Plastic Bushes AVCD-Flange type AVCD-Slip & Clip type AVCD-Box type AVCD-Hat type AVCD with gear mechanism 5

VOLUME CONTROL DAMPER AVCD SERIES VOLUME CONTROL DAMPER - AVCD SERIES AEROFOIL ALUMINUM S OPTIONS MANUAL QUADRANT MODELS FEATURE MODEL AVCDG2PLH AVCDG2BLH AVCDG2PLF AVCDG2BLF AVCDG2PLS AVCDG2BLS AVCDG2PLB AVCDG2BLB AVCDG2PGH AVCDG2BGH AVCDG2PGF AVCDG2BGF AVCDG2PGS AVCDG2BGS AVCDG2PGB AVCDG2BGB AVCDS2SLH AVCDS2SLF AVCDS2SLS AVCDS2BLB AVCDS2SGH AVCDS2SGF AVCDS2SGS AVCDS2SGB AVCDG2-SMC AVCDS2-SMC DRIVE MOVEMENT USE CONSTRUCTION BUSHING/ BEARING MECHANISM FIXING TO DUCT MANUAL QUADRANT ELECTRIC ACTUATOR G.I. 3V-SHAPED ALUMINUM AEROFOIL OPPOSED PARALLEL ABOVE MODELS (EXCEPT THE ONES WITH GEAR MECHANISM) CAN BE WITH PARALLEL S, PLS. WRITE PARALLEL ON YOUR ORDER CONTROL (AIR BALANCING) LOW LEAKAGE (AIR TIGHT SHUT OFF) GALVANIZED STEEL STAINLESS STEEL 304 PLASTIC BUSHES BRASS BUSHES S.S. BEARING G.I. LINKAGE PLASTIC GEARS HAT-SHAPED FLANGE SLIP & CLIP BOX (INSERTED INSIDE DUCT) **Other options of S.S. bushes "X" and S.S. bearing "S" are shown at the ordering key. MOTORIZED MODELS FEATURE MODEL MAVCDG2PLH MAVCDG2BLH MAVCDG2PLF MAVCDG2BLF MAVCDG2PLS MAVCDG2BLS MAVCDG2PLB MAVCDG2BLB MAVCDG2PGH MAVCDG2BGH MAVCDG2PGF MAVCDG2BGF MAVCDG2PGS MAVCDG2BGS MAVCDG2PGB MAVCDG2BGB MAVCDS2SLH MAVCDS2SLF MAVCDS2SLS MAVCDS2BLB MAVCDS2SGH MAVCDS2SGF MAVCDS2SGS MAVCDS2SGB MAVCDG2-SMC MAVCDS2-SMC DRIVE MOVEMENT USE CONSTRUCTION BUSHING/ BEARING MECHANISM FIXING TO DUCT MANUAL QUADRANT ELECTRIC ACTUATOR G.I. 3V-SHAPED ALUMINUM AEROFOIL OPPOSED PARALLEL ABOVE MODELS (EXCEPT THE ONES WITH GEAR MECHANISM) CAN BE WITH PARALLEL S, PLS. WRITE PARALLEL ON YOUR ORDER CONTROL (AIR BALANCING) LOW LEAKAGE (AIR TIGHT SHUT OFF) GALVANIZED STEEL STAINLESS STEEL 304 PLASTIC BUSHES BRASS BUSHES S.S. BEARING G.I. LINKAGE PLASTIC GEARS HAT-SHAPED FLANGE SLIP & CLIP BOX (INSERTED INSIDE DUCT) **Other options of S.S. bushes "X" and S.S. bearing "S" are shown at the ordering key. 6

VOLUME CONTROL DAMPER AVCD SERIES VOLUME CONTROL DAMPER - AVCD SERIES AEROFOIL ALUMINUM S PERFORMANCE DATA 0.300 OPPOSED S 40 PARALLEL S PRESSURE DROP, IWG 0.030 10 0.003 5.0 1.0 0.5 4,000 2,400 1,500 900 FACE VELOCITY, FPM Ordering Key: M A VCD G2 P L F SIZE - - : QUADRANT DRIVED M: MOTORIZED A: AEROFOIL ALUMINUM S VCD: VOLUME CONTROL DAMPER G1: 0.9MM G.I.CONSTRUCTION G2: 1.2MM G.I.CONSTRUCTION (STANDARD) G3: 1.5MM G.I.CONSTRUCTION G4: 1.7MM G.I.CONSTRUCTION S1: 1.0MM S.S. 304 CONSTRUCTION S2: 1.2MM S.S. 304 CONSTRUCTION S3 1.5MM S.S. 304 CONSTRUCTION S4: 1.7MM S.S. 304 CONSTRUCTION P: PLASTIC BUSHES (STANDARD) B: BRASS BUSHES X: S.S. BUSHES S: S.S. BEARINGS L: G.I. LINKAGE MECHANISM (STANDARD) G: PLASTIC GEARS MECHANISM H: HAT-SHAPED FRAME F: FLANGED TO DUCT (STANDARD) S: SLIP & CLIP WITH DUCT B: BOX (INSERTED INSIDE DUCT) SIZE: WIDTH X HEIGHT 7

LOW-LEAKAGE VOLUME CONTROL DAMPER LVCD SERIES LOW-LEAKAGE VOLUME CONTROL DAMPER - LVCD SERIES 3V-SHAPED STEEL S STANDARD CONSTRUCTION Frame: Blades: Bushes: Axles: 133mm Roll formed hat-shaped made of 1.2mm thick galvanized steel with reinforced corners, having integral bracing and 90º perpendicular overlap at a corner. Roll formed 3 V-shaped made of 1.2mm thick galvanized steel. Brass bushes. 1/2" Square axles made of galvanized steel. Model LVCDG2BLH Linkage: Mechanical and concealed in frame. Jamb Seals: Stainless steel jamb seals. Blades Seal: Silicone blades edges seal/gasket. Leakage: Class 1 Air Flow Rating: 2000 FPM / 4 IWG. Model MLVCDG2BLH Sizes: Single Section: Max. 36" X 36" Multiple Section: Max. 72" X 72" DIMENSIONS 133 20.0 133 25 23.2 LVCD-Flange type LVCD-Hat type 8

LOW-LEAKAGE VOLUME CONTROL DAMPER LVCD SERIES LOW-LEAKAGE VOLUME CONTROL DAMPER - LVCD SERIES 3V-SHAPED STEEL S OPTIONS MANUAL QUADRANT MODELS FEATURE MODEL LVCDG2BLH LVCDG2XLH LVCDG2BLF LVCDG2XLF LVCDS2SLH LVCDS2SLF LVCDG2-SCM LVCDS2-SMC DRIVE MANUAL QUADRANT ELECTRIC ACTUATOR G.I. 3V-SHAPED ALUMINUM AEROFOIL OPPOSED MOVEMENT PARALLEL USE CONSTRUCTION BUSHING/ BEARING MECHANISM FIXING TO DUCT CONTROL (AIR BALANCING) LOW LEAKAGE APPLICATIONS GALVANIZED STEEL STAINLESS STEEL 304 PLASTIC BUSHES BRASS BUSHES S.S. BUSHES S.S. BEARING G.I. LINKAGE PLASTIC GEARS HAT-SHAPED FLANGE SLIP & CLIP BOX (INSERTED INSIDE DUCT) MOTORIZED MODELS FEATURE MODEL MLVCDG2BLH MLVCDG2XLH MLVCDG2BLF MLVCDG2XLF MLVCDS2SLH MLVCDS2SLF MLVCDG2-SMC MLVCDS2-SMC DRIVE MANUAL QUADRANT ELECTRIC ACTUATOR G.I. 3V-SHAPED ALUMINUM AEROFOIL OPPOSED MOVEMENT PARALLEL USE CONSTRUCTION BUSHING/ BEARING MECHANISM FIXING TO DUCT CONTROL (AIR BALANCING) LOW LEAKAGE APPLICATIONS GALVANIZED STEEL STAINLESS STEEL 304 PLASTIC BUSHES BRASS BUSHES S.S. BUSHES S.S. BEARING G.I. LINKAGE PLASTIC GEARS HAT-SHAPED FLANGE SLIP & CLIP BOX (INSERTED INSIDE DUCT) 9

LOW-LEAKAGE VOLUME CONTROL DAMPER LVCD SERIES LOW-LEAKAGE VOLUME CONTROL DAMPER - LVCD SERIES 3V-SHAPED STEEL S PERFORMANCE DATA Ordering Key: --: QUADRANT- DRIVED M: MOTORIZED M L VCD G2 B L H SIZE L: 3V-SHAPED G.I. S LOW-LEAKAGE VCD: CONTROL DAMPER G1: 0.9MM G.I. CONSTRUCTION G2: 1.2MM G.I. CONSTRUCTION (STANDARD) G3: 1.5MM G.I. CONSTRUCTION G4: 1.7MM G.I. CONSTRUCTION S1: 1.0MM S.S. 304 CONSTRUCTION S2: 1.2MM S.S 304 CONSTRUCTION S3: 1.5MM S.S 304 CONSTRUCTION S4: 1.7MM S.S 304 CONSTRUCTION B: BRASS BUSHES (STANDARD) X: S.S. BUSHES S: S.S. BEARINGS L: G.I LINKAGE MECHANISM (STANDARD) H: HAT-SHAPED FRAME (STANDARD) F: FLANGED TO DUCT SIZE: WIDTH X HEIGHT 10

ROUND VOLUME CONTROL DAMPER VDR SERIES ROUND VOLUME CONTROL DAMPER - VDR MODEL STEEL STANDARD CONSTRUCTION Frame: 0.9mm thick galvanized steel sheet. Blades: 0.9mm thick galvanized steel sheet. Axles: ½ square hollow Aluminum extruded profile. Bushing: Self lubricating plastic bushes. Model VDRG2P Quadrant: Plated steel with wing nut to lock the blades position. Marked to show the position of the blades. Seal: Foam gasket. Sizes: 4, 5, 6, 8, 10, 12, 14, 16, 18, 20, 22 & 24 inch diameter. Model MVDRG2P Plastic Bushes DIMENSIONS 30 mm dia L 30 mm L = dia. + 60mm 11

ROUND VOLUME CONTROL DAMPER VDR SERIES ROUND VOLUME CONTROL DAMPER - VDR MODEL STEEL OPTIONS FEATURE MODEL VDRG2P VDRG2B MANUAL QUADRANT MODELS VDR G 2X VDR G 2S VDRS2X VDRS2S VDRG2-SMC VDRS2-SMC MVDRG2P MVDRG2B MOTORIZED MODELS MVDRG2X MVDRG2S MVDRS2X MVDRS2S MVDRG2-SMC MVDRS2-SMC DRIVE USE CONSTRUCTION BUSHING/ BEARING MANUAL QUADRANT ELECTRIC ACTUATOR SINGLE SKIN CONTROL (AIR BALANCING) LOW LEAKAGE (AIR TIGHT SHUTT OFF) GALVANIZED STEEL STAINLESS STEEL 304 PLASTIC BUSHES BRASS BUSHES S.S. BUSHES S.S. BEARING **Other options of S.S. bushes "X" and S.S. bearing "S" are shown at the ordering key. Ordering Key: M V DR G2 P SIZE - -: QUADRANT- DRIVED M: MOTORIZED V: SINGLE SKIN DR: CONTROL DAMPER ROUND G1: 0.7MM G.I. CONSTRUCTION G2: 0.9MM G.I. CONSTRUCTION (STANDARD) G3: 1.2MM G.I. CONSTRUCTION G4: 1.5MM G.I. CONSTRUCTION S1: 0.8MM S.S. 304 CONSTRUCTION S2: 1.0MM S.S 304 CONSTRUCTION S3: 1.2MM S.S 304 CONSTRUCTION P: PLASTIC BUSHES (STANDARD) B: BRASS BUSHES X: S.S. BUSHES S: S.S. BEARINGS SIZE: DIAMETER OF 4, 5, 6, 8, 10, 12, 14, 16, 18, 20, 22 or 24 12

ROUND VOLUME CONTROL DAMPER VDR SERIES ROUND VOLUME CONTROL DAMPER - VDR MODEL STEEL PERFORMANCE DATA Beta Industrial LLCcertifies that the VDR shown hereon is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to Air Leakage and Air Performance ratings. Test Information * Air leakage is based on operation between 32 F and 120 F * Tested for air leakage at standard air density in accordance with ANSI/AMCA Standard 500-D, Figure 5.4 * Tested for air performanceat standard air density in accordance with ANSI/AMCA 500-D, Figure 5.3 * Data are based on a torque of 117 in-lb/ft² applied to close and seat the damper during the test. AIR PERFORMANCE DATA AIR LEAKAGE DATA Bulletin No. 8, January 2017 13

BACKDRAFT DAMPER - NRD SERIES NON-RETURN DAMPER - MODEL NRD STANDARD CONSTRUCTION Frame: 0.9mm thick galvanized steel. Blades: 1.0mm thick extruded Aluminum profiles. Bushing: Brass bushes. Axles: Round extruded Aluminum profiles. Seal: Foam blades seals. Size: Single section up to 600 X 600mm. OPTIONS Model NRD-CR FEATURE MODEL NRD NRD-CR NRDE NRD E -CR BRASS BUSHES S- CONNECTING ROD COUNTERWEIGHT YES NO YES NO NO FLANGES 2 SIDES FINISH MILL FINISH INSTALLATIO N 2-SIDES DUCTED APPLICATION DISCHARGE & INTAKE DUCTED NON RETURN DAMPER NRD MODEL: 100 mm Brass Bush DIMENSIONS 25 mm Blade 100 mm B -10mm CLOSED A -10mm OPEN 14

BACKDRAFT DAMPER - NRD SERIES NON-RETURN DAMPER - MODEL NRD PERFORMANCE DATA Beta Industrial LLC certifies that the NRD-CR shown hereon is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to Air Leakage and Air Perfomance ratings. Test Information Air leakage is based on operation between 32 F and 120 F Tests were conducted at standard air density in accordance with ANSI/AMCA Standard 500-D, Figure 5.4, on a 24 in. x 24 in. sample Air Performance testing conducted in accordance with ANSI/AMCA Standard 500-D, Figure 5.4 AIR LEAKAGE DATA AIR PERFORMANCE DATA Ordering Key: N R D E CR W X H NRD: NON-RETURN DAMPER WITH BRASS BUSHES NRD-CR: NON-RETURN DAMPER WITH BRASS BUSHES & CONNECTING ROD NRDE: NON-RETURN DAMPER WITHOUT BRASS BUSHES NRDE-CR: NON-RETURN DAMPER WITHOUT BRASS BUSHES WITH CONNECTING ROD SIZE: WIDTH X HEIGHT Bulletin No. 8, January 2017 15

BACKDRAFT DAMPER - PRD SERIES PRESSURE RELIEF DAMPER - MODEL PRD STANDARD CONSTRUCTION PRD: Frame: 0.9mm thick galvanized steel. Blades: 1.0mm thick extruded Aluminum profiles with adjustable counterweight for fine-tune operation. Axles: Round extruded Aluminum profiles. Bushing: Brass bushes. Seal: Foam blades seals. Size: Single section up to 1200 X 1200mm. DPRD & IPRD: Frame: 1.2mm thick extruded Aluminum profiles. Blades: 1.0mm thick extruded Aluminum profiles with adjustable counterweight for fine-tune operation. Axles: Round extruded Aluminum profiles. Bushing: Brass bushes. Seal: Foam blades seals. Size: Single section up to 1200 X 1200mm. Model PRD OPTIONS Model DPRD FEATURE MODEL PRD DPRD IPRD BRASS BUSHES YES S- CONNECTING ROD YES COUNTERWEIGHT YES FLANGES FINISH INSTALLATION APPLICATION 1 SIDE 2 SIDES MILL FINISH POWDER COATED TO RAL9010/9016 2-SIDES DUCTED WALL-MOUNTED DISCHARGE INTAKE DIMENSIONS DUCTED PRESSURE RELIEF DAMPER PRD MODEL: fixing hole 100 100 fixing hole B -10mm 25 fixing hole fixing hole CLOSED A -10mm OPEN 16

BACKDRAFT DAMPER - PRD SERIES DISCHARGE/INTAKE WALL-MOUNTED PRESSURE Adjustable RELIEF DAMPER DPRD MODEL: counterweight Adjustable Counterweight 45 fixing hole DIMENSIONS 30 Adjustable counterweight B P 30 B -10mm fixing hole CLOSED A -10mm INTAKE OPEN DISCHARGE FOR PRD MODELS: 100 PRESSURE, Pa 10 1 0.5 1.0 AIR VELOCITY, m/s 5.0 10.0 20.0 Ordering Key: D P R D W X H PRD: DUCTED PRESSURE RELIEF DAMPER DPRD: DISCHARGE WALL-MOUNTED PRESSURE RELIEF DAMPER IPRD: INTAKE WALL-MOUNTED PRESSURE RELIEF DAMPER SIZE: WIDTH X HEIGHT 17

ACCESS DOORS ACC2L, ACCPH & ACCPHLK Description: Made of 1.2mm thick galvanized steel. ACC2L ACCPH ACCPHLK 3. - 2 cam locks (standard) - 1 cam lock & Piano-hinge. - Piano-hinge & handle operated lock with key. Dimensions : ACCESS DOOR WITH 2 CAM LOCKS ACCESS DOOR WITH A CAM LOCK & PIANO HINGE ACCESS DOOR WITH A HANDLE OPERATED LOCK & PIANO HINGE WIDTH + 2X25 WIDTH + 2X25 HEIGHT - 5 HEIGHT - 2X25 HEIGHT - 5 HEIGHT - 2X25 HEIGHT - 5 WIDTH - 5 WIDTH - 5 WIDTH - 5 Cam Lock Cam Lock Cam Lock Hinge Handle Operated lock Hinge WIDTH - 5 WIDTH - 5 WIDTH - 5 Handle Operated lock Door panel - A Door panel - B 20 25 HEIGHT - 5 25 20 25 HEIGHT - 5 25 37 HEIGHT - 5 18

ACCESS DOORS ACC2L, ACCPH & ACCPHLK OPTIONS ACC2LD ACCSHD ACCPHLK A C C P H L K W X H ACCESS DOOR 2L : WITH 2 CAM LOCKS ( STANDARD ) 2LD : WITH 2 CAM LOCKS & DRAWER- HANDLE PH : WITH PIANO HINGE & A CAM LOCK PHD : WITH PIANO HINGE, A CAM LOCK & DRAWER- HANDLE SH : WITH SEPARATE HINGES & A CAM LOCK SHD : WITH SEPARATE HINGES, A CAM LOCK & DRAWER- HANDLE PHLK : WITH PIANO HINGES & HANDLE OPERATED LOCK WITH A KEY SHLK : WITH SEPARATE BUTT HINGES & HANDLE OPERATED LOCK / KEY SIZE : WIDTH X HEIGHT 19

Dubai Head Office: Tel: +971 4 706 9777 Fax: +971 4 706 9787 Abu Dhabi Branch: Tel: +971 2 645 0107 Fax: +971 2 645 0167 Saudi Arabia: Tel: +966 1 265 4551 Fax: +966 1 265 4550 Email: betai@betag.com P.O.Box 50708, Dubai United Arab Emirates