Typical UL489 Application Power Circuit of a UL508A Panel

Similar documents
Typical UL1077 Application

Control Circuit of a UL508A Panel. Typical UL1077 Application

Quality Commitment UL 489 UL 508 UL Equipment Breakers. Earth Leakage. Circuit Breakers

E s h o r t c ir c u it Wit h s t AND r At ing s f o r r -s er ies s u ppl ement Ar y pr o t ec t o r

Jtec 489 UL489 Branch Circuit Breaker

Miniature Circuit Breakers

Altech UL508. Typical UL508 Application. Power Circuit of a UL508A Panel

Jtec 10kA Miniature Circuit Breaker

UMBW-UL489 and UL1077 Listed

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

S200 UL 489 Series. Miniature circuit breakers S200. Features. Description

LCIRCUIT BREAKERS. Jtec UL (Motor Disconnect) General Information...L2 Trip Curves & Dimensions...L3

max pole for t=15 ms

Control Circuit Protection

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)

Thermal-magnetic Miniature Circuit Breaker 4230-T...

S200 UL 1077 Series S200. Supplementary protective devices. UL 1077 Series. Miniature. circuit breakers. S200 Supplementary protective devices

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

Series L9 UL-489 Miniature Circuit Breakers

Series KTU7 UL489 Molded Case Circuit Breakers

S200-C, 480Y/277 VAC Supplemental protectors UL 1077, CSA 22.2

G-Series. Circuit Breaker.

Thermal-magnetic Miniature Circuit Breaker 4230-T...

Series KTU7 UL489 Molded Case Circuit Breakers

Technical Information

Bulletin 1489 Circuit Breakers. Selection Guide

F-Series. Circuit Breaker

F-Series. Circuit Breaker

Motors Automation Energy Transmission & Distribution Coatings. UMBW UL489 and UL1077 Thermal-Magnetic MCB

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS

Thermal Circuit Breaker 3120-F...

Series L9 UL489 Miniature Circuit Breakers

Table Types LD, HLD and LDC Thermal-Magnetic Circuit Breakers with Interchangeable Trip Units

Protection Equipment. 5/2 Introduction

TMC 91H is now TMC 60 C Series

MCBs and accessories are certified under CSA C22.2 No. 235 per File LR Tripping characteristics

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G V

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

Thermal-Magnetic Circuit Breaker 2210-S291-P9M A

S200 UL 489 Series. Miniature Circuit Breakers. Description. Features

IP20 degree of protection; IP40 degree of protection after installation in a distribution box

Thermal-Magnetic Circuit Breaker M1-...

ELFA E90S MINI BREAKERS

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F...

Technical Information

PB-Series. GFCI/ELCI & Panel Seal

Thermal Overcurrent Circuit Breaker 3120-F...

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077

Miniature Circuit Breaker

Magnetic and Hydraulic-Magnetic Circuit Breaker

Selection Guide. Control Circuit and Load Protection

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Magnetic and Hydraulic-Magnetic Circuit Breaker

Protection Equipment

PD-Series Ground Fault Circuit Protection

Thermal Overcurrent Circuit Breaker 3120-F...

22AF 40AF AF 150AF 225AF 400AF 800AF

Tmax Molded Case Circuit Breakers

1492-CB 1492-GH 1492-GS

Thermal Overcurrent Circuit Breaker 3120-F...

Altech UL1077/508 Busbar System

Product Line Overview. The Most Logically Designed Contact Assembly

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal-Magnetic Circuit Breaker M1-..

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A

Table Line and Load Terminals. Terminal Body Material. Wire Type. Aluminum Copper Aluminum. English English English.

Thermal Overcurrent Circuit Breaker 3120-F...

MINIATURE CIRCUIT BREAKER

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489

1489-M Circuit Breakers

www. ElectricalPartManuals. com Miniature Circuit Breakers Section 7

NB1 Miniature Circuit Breaker

DRX 125 Circuit breaker (not adjustable)

MCBs S260 S290. Pro M Miniature Circuit Breakers S260, S270, S280, S290. System Pro M. Description. Features

Data Sheet DIN Rail Miniature Circuit Breakers Ex9 Series - B1NQ

Circuit breakers for power distribution A1 Ordering information

LOW VOLTAGE SWITCHGEAR

cor Long Run Experience

Magnetic Overcurrent Circuit Breaker

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

RESIDUAL CURRENT CIRCUIT BREAKERS WITH OVERCURRENT PROTECTION OLE

Instantaneous tripping TYPE B, C, D TYPE B, C TYPE B, C, D TYPE B, C IEC RCCB TYPE C IEC61008 RCBO 25, 40, 63A. IEC61009 Isolating Switch

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

NRBM Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute

DPX moulded case circuit breakers

209/219/229/249/279 Series Magnetic Circuit Protectors

Thermal Overcurrent Circuit Breaker 3120-F...

Selection Guide Motor Control Device Solutions

DPX Magnetic only

Essential equipment for all your requirements

UTS400 SELECTION GUIDE CATALOG NUMBERING [PRODUCT SELECTION] UTS400 NT ATU 400A 3P LL LSIS UL MCCB

DPX Thermal magnetic and trip-free switches DPX 3 -I 250

Basic function. Rated current. Appropriate for three-phase motors of output 2) [kw] I n. = 400 V a.c. 2) Appropriate for three-phase motors

Q and M-Frame Circuit Breaker Instruction Leaflet for Installation and Operation for Thermal Magnetic Trip Units

Magnetic and Hydraulic-Magnetic Circuit Breaker

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

AC Relays. Type IC5182. Ordering Information. Control Power Requirements. Contact Ratings (Amperes)

Circuit Protection. Circiut Protection

Transcription:

Altech UL489 Typical UL489 Application Power Circuit of a UL508A Panel Disclaimer: This is an application example. Installation should be done by a qualified electrician under the guidance of UL specifications.. 38

L-Series AC or DC Miniature Molded Case Circuit Breakers UL489 Listed Circuit Breakers Available in AC and DC models DIN Rail Mounted 7.5mm width Thermal Magnetic 2V, 480Y/277V AC, 50/60Hz 25VDC ( pole); 250VDC (2pole) ka Short Circuit Interrupting Capacity Positive Trip indicator (Green - off/tripped, Red - on) HACR Type C Line/Load reversible / Voltage Rating Calibration Temperature Terminal Size Acceptability - min/max Terminal Torque - min/max Terminal Protection Degree Electrical Life Mechanical Life Wire Connection AC - SHORT CIRCUIT INTERRUPTING RATING No. Poles Type 0.2-33- AC ka@20, 2, 277V ka@20, 2V 2-4 AC ka@20, 2V, 480Y/277V ka@20, 2V 0.2-/2VAC, 0.2-/480Y/277VAC 0.2-/25/250VDC C (4 F) 2.5mm 2 (2 AWG) / 25mm 2 (3 AWG).5 Nm (3 lbs. in.) / 2 Nm (7.5 lb. in.) IP20 6000 cycles on/off 0000 cycles on/off copper wire only 60/75 C DC - SHORT CIRCUIT INTERRUPTING RATING No. Poles Type 0.2-33- DC ka@25v ka@25v 2 DC ka@250v ka@250v 39Altech UL489

Altech UL489 Seconds Time t Minutes 60 4 4 0.4-4x -2-2 4x -3 C D Time versus Trip Curve For the exact trip curve, please refer to page 48. Dimensions in mm side view 45mm (.77 in.) -3 2 3 4 6 8 6 20 Multiple of 6.5mm (0.26 in.) 44mm (.73 in.) 60mm (2.36 in.) POLE 4.5mm (0.57 in.) 2 POLE 4.5mm (0.57 in.) 3 POLE 4.5mm (0.57 in.) 9mm (4.29 in.) 69mm (2.72 in.) 9mm (4.29 in.) 69mm (2.72 in.) 9mm (4.29 in.) 69mm (2.72 in.) 7.5mm (0.69 in.) 7.5mm (0.69 in.) 35mm (.38 in.) 7.5mm (0.69 in.) 35mm (.38 in.) 52.5mm (2.07 in.) Trip-Characteristics* Type Applications Characteristic Trip Boundaries Thermal Trip Must not Trip>0ms Must Trip <hr Magnetic Trip Must not Trip>0ms Must Trip at 0ms Lighting Wiring Protection Control Circuits Business Equipment Appliances Transformers Power Supplies Heaters Low Inrush Motors High Inrush Reactive Load C-Characteristics.05xRC.3xRC 5xRC xrc.05xrc.3xrc 5xRC xrc AC DC D-Characteristics.05xRC.3xRC xrc 6xRC.05xRC.3xRC xrc 6xRC AC DC *The value of each characteristic is shown vertically beneath its corresponding heading. Warning! This information should only be used as a selection guide. The use of a Miniature Circuit Breaker in an application with a certain Trip-Characteristic always requires prototype testing! It is the responsibility of the circuit design engineer to select the appropriate Miniature Circuit Breaker for his specific application.

AC C-Trip Characteristics Application Examples: Low inrush motors, resistive loads, wiring protection, receptacles, lighting, and control circuit applications. Relatively short thermal trip delay and medium magnetic trip point. One Pole 0.2A CU02L 0.5A CU05L.0A CUL.6A CU.6L 2.0A CU2L 3.0A CU3L 4.0A CU4L 5.0A CU5L 6.0A CU6L 8.0A CU8L A CUL 2A CU2L 3A CU3L 5A CU5L 6A CU6L CU20L CU25L CU30L CU32L A CUL CU50L CU60L CU63L Two Pole 0.2A 2CU02L 0.5A 2CU05L.0A 2CUL.6A 2CU.6L 2.0A 2CU2L 3.0A 2CU3L 4.0A 2CU4L 5.0A 2CU5L 6.0A 2CU6L 8.0A 2CU8L A 2CUL 2A 2CU2L 3A 2CU3L 5A 2CU5L 6A 2CU6L 2CU20L 2CU25L 2CU30L 2CU32L A 2CUL 2CU50L 2CU60L 2CU63L Standard Pack: 2 Standard Pack: 6 Weight:.7kg (3.74 lb.) Weight:.7kg (3.74 lb.) Three Pole 0.2A 3CU02L 0.5A 3CU05L.0A 3CUL.6A 3CU.6L 2.0A 3CU2L 3.0A 3CU3L 4.0A 3CU4L 5.0A 3CU5L 6.0A 3CU6L 8.0A 3CU8L A 3CUL 2A 3CU2L 3A 3CU3L 5A 3CU5L 6A 3CU6L 3CU20L 3CU25L 3CU30L 3CU32L A 3CUL 3CU50L 3CU60L 3CU63L Standard Pack: 4 Weight:.7kg (3.74 lb.) Four Pole Please contact Altech. 4Altech UL489

Altech UL489 AC D-Trip Characteristics One Pole Application Examples: Low inrush motors, resistive loads, wiring protection, receptacles, lighting, and control circuit applications. Relatively short thermal trip delay and medium magnetic trip point. 0.2A DU02L 0.5A DU05L.0A DUL.6A DU.6L 2.0A DU2L 3.0A DU3L 4.0A DU4L 5.0A DU5L 6.0A DU6L 8.0A DU8L A DUL 2A DU2L 3A DU3L 5A DU5L 6A DU6L DU20L DU25L DU30L DU32L A DUL DU50L DU60L DU63L Two Pole 0.2A 2DU02L 0.5A 2DU05L.0A 2DUL.6A 2DU.6L 2.0A 2DU2L 3.0A 2DU3L 4.0A 2DU4L 5.0A 2DU5L 6.0A 2DU6L 8.0A 2DU8L A 2DUL 2A 2DU2L 3A 2DU3L 5A 2DU5L 6A 2DU6L 2DU20L 2DU25L 2DU30L 2DU32L A 2DUL 2DU50L 2DU60L 2DU63L Standard Pack: 2 Weight:.7kg (3.74 lb.) Standard Pack: 6 Weight:.7kg (3.74 lb.) Three Pole 0.2A 3DU02L 0.5A 3DU05L.0A 3DUL.6A 3DU.6L 2.0A 3DU2L 3.0A 3DU3L 4.0A 3DU4L 5.0A 3DU5L 6.0A 3DU6L 8.0A 3DU8L A 3DUL 2A 3DU2L 3A 3DU3L 5A 3DU5L 6A 3DU6L 3DU20L 3DU25L 3DU30L 3DU32L A 3DUL 3DU50L 3DU60L 3DU63L Standard Pack: 4 Weight:.7kg (3.74 lb.) Four Pole Please contact Altech. 42

DC C- & D-Trip Characteristics Application Examples: Telecommunication equipment, computer equipment, uniterruptable power supplies. One Pole 0.2A DCCU02L 0.5A DCCU05L.0A DCCUL.6A DCCU.6L 2.0A DCCU2L 3.0A DCCU3L 4.0A DCCU4L 5.0A DCCU5L 6.0A DCCU6L 8.0A DCCU8L A DCCUL 2A DCCU2L 3A DCCU3L 5A DCCU5L 6A DCCU6L DCCU20L DCCU25L DCCU30L DCCU32L A DCCUL DCCU50L DCCU60L DCCU63L Two Pole 0.2A DC2CU02L 0.5A DC2CU05L.0A DC2CUL.6A DC2CU.6L 2.0A DC2CU2L 3.0A DC2CU3L 4.0A DC2CU4L 5.0A DC2CU5L 6.0A DC2CU6L 8.0A DC2CU8L A DC2CUL 2A DC2CU2L 3A DC2CU3L 5A DC2CU5L 6A DC2CU6L DC2CU20L DC2CU25L DC2CU30L DC2CU32L A DC2CUL DC2CU50L DC2CU60L DC2CU63L Standard Pack: 2 Standard Pack: 6 Weight:.7kg (3.74 lb.) Weight:.7kg (3.74 lb.) One Pole 0.2A DCDU02L 0.5A DCDU05L.0A DCDUL.6A DCDU.6L 2.0A DCDU2L 3.0A DCDU3L 4.0A DCDU4L 5.0A DCDU5L 6.0A DCDU6L 8.0A DCDU8L A DCDUL 2A DCDU2L 3A DCDU3L 5A DCDU5L 6A DCDU6L DCDU20L DCDU25L DCDU30L DCDU32L A DCDUL DCDU50L DCDU60L DCDU63L Standard Pack: 2 Weight:.7kg (3.74 lb.) Two Pole 0.2A DC2DU02L 0.5A DC2DU05L.0A DC2DUL.6A DC2DU.6L 2.0A DC2DU2L 3.0A DC2DU3L 4.0A DC2DU4L 5.0A DC2DU5L 6.0A DC2DU6L 8.0A DC2DU8L A DC2DUL 2A DC2DU2L 3A DC2DU3L 5A DC2DU5L 6A DC2DU6L DC2DU20L DC2DU25L DC2DU30L DC2DU32L A DC2DUL DC2DU50L DC2DU60L DC2DU63L Standard Pack: 6 Weight:.7kg (3.74 lb.) 43Altech UL489

Altech UL489 L-Series Trip Curves C and D Trip Less than A Tripping time t Seconds Minutes 20 60 20 8 6 4 2 20 5 0.5 0. 0.05 0.0.05.3 C and D Trip A and higher Tripping time t Seconds Minutes 7200 3600 20 200 600 480 360 2 20 0. C D 0.05 C D 0.0 2 3 4 5 6 7 8 9 2 46 20 2 3 4 5 6 7 8 9 2 46.05.3 Multiple of Multiple of 60 20 5 0.5 20 Temperature and Power Loss Specifications current In (A) rated current allowing for ambient temperature I cor (A) Internal impedance Z(mΩ) char. B, C, D, K Power Loss B, C, D, K P (W) -20-0 20 30 50 60 0.2 0.24 0.24 0.23 0.22 0.2 0.2 0.9 0.8 0.7 450.0.80 0.5 0.6 0.59 0.57 0.55 0.53 0.5 0.47 0.44 0.42 8000.0 2.00.2.8.4..05.0 0.93 0.88 0.83 2000.0 2.00 2 2.42 2.36 2.28 2.2 2. 2.0.86.76.67 490.0.96 3 3.63 3.54 3.42 3.3 3.5 3.0 2.79 2.64 2.5 230.0 2.07 4 4.84 4.72 4.56 4.4 4.2 4.0 3.72 3.52 3.33 50.0 2. 5 6. 5.9 5.7 5.5 5.3 5.0 4.7 4.4 4.2 95.0 2.38 6 7.3 7. 6.8 6.6 6.3 6.0 5.6 5.3 5.0 69.0 2.48 7 8.5 8.2 8.0 7.7 7.4 7.0 6.5 6.2 5.8 52.0 2.55 8 9.7 9.4 9. 8.8 8.4 8.0 7.4 7.0 6.7 35.0 2.24 2..8.4.0.5.0 9.3 8.8 8.3 23.5 2.35 2 4.5 4.2 3.7 3.2 2.6 2.0.2.6.0 8.7 2.69 3 5.7 5.3 4.8 4.3 3.7 3.0 2..5.8 4.3 2.42 4 6.9 6.5 6.0 5.4 4.7 4.0 3.0 2.3.7 2.4 2.43 5 8.2 7.7 7. 6.5 5.8 5.0 4.0 3.2 2.5. 2.27 6 9.4 8.9 8.2 7.6 6.8 6.0 4.9 4. 3.3 7.5.92 20 24.2 23.6 22.8 22.0 2.0 20.0 8.6 7.6 6.7 6.3 2.52 25 30.3 29.5 28.5 27.5 26.3 25.0 23.3 22.0 20.8 4.6 2.88 30 36.3 35.4 34.2 33.0 3.5 30.0 27.9 26.5 25.0 3.6 3.24 32 38.7 37.8 36.5 35.2 33.6 32.0 29.8 28.2 26.7 3.6 3.69 35 42.3 4.3 39.9 38.5 36.8 35.0 32.6 30.8 29.2 3.6 4.4 48.4 47.2 45.6 44.0 42.0.0 37.2 35.2 33.3 3.0 4.80 50 60.5 59.0 57.0 55.0 52.5 50.0 46.5 44. 4.7 2.4 6.00 60 72.6 70.9 68.4 66.0 63.0 60.0 55.9 52.9 50..8 6.48 44

Accessories L-Series Circuit Breakers Shunt Trip Undervoltage Trip Accessories can be factory or field mounted on L-Series miniature molded case circuit breakers for enhanced control and monitoring capabilities. Field mounting kits include all necessary parts and instructions. Accessories can be gang mounted on a single controller (the Auxiliary Switch in the outside position). The mounting arrangement links the internal latch-pins for the tripping mechanisms, ensuring simultaneous trips. Handles are linked to simplify manual resetting. Neutral Pole (/2VAC; /480Y/277VAC) Description Cable Cable Torque Torque Max Min Max Min Neutral ALTN2L 25mm 2 2.5mm 2 2Nm.5Nm 3 AWG 2 AWG 7.5 lb-in 2 lb-in Standard Pack: Weight:.2kg (2.64 lb.) Shunt Trip and Undervoltage Trip Description Shunt Trip Undervoltage Trip Cable Cable Torque Torque Max Min Max Min AC Coil: 2V AC FA2ACL UV2ACL 24V AC FA24ACL UV24ACL 48V AC FA48ACL UV48ACL 60V AC FACL UVCL V AC FAACL UVACL 20V AC FACL UVCL 230V AC FA2CL UV2CL 277V AC FA277ACL UV277ACL 0V AC FA0ACL UV0ACL DC Coil: 2V DC FA2DCL UV2DCL 24V DC FA24DCL UV24DCL 48V DC FA48DCL UV48DCL V DC FADCL UVDCL 25mm 2 2.5mm 2 2Nm.5Nm 3 AWG 2 AWG 7.5 lb-in 2 lb-in 25mm 2 2.5mm 2 2Nm.5Nm 3 AWG 2 AWG 7.5 lb-in 2 lb-in Standard Pack: Weight:.kg (2.43 lb.) Auxiliary Contact Description Cable Cable Torque Torque Max Min Max Min x CO HCOL 2 x CO H2COL x CO, Signal HSTCOL & Test Button Standard Pack: 5 Weight: 0.5kg (.32 lb.) Lock-out Adaptor Description Yellow Standard Pack: Weight: 50g (.76 oz.) (6A/20VAC; 3A/2VAC) EASS2L 2.5mm 2 0.5mm 2 0.5Nm 0.33Nm 2 AWG 20 AWG 4 lb-in 3 lb-in 45Altech UL489