Broadband PowerShield. CP27U Models. User Manual

Similar documents
BroadBand PowerShield. 20 AHr Battery. User Manual

Installation Power Management Unit Battery Cables and Battery Harness

Broadband PowerShield. External Battery Pack 20 Ah 12 V Battery. User Manual

Installation Guide Smart-UPS On-Line External Battery Pack XBP48RM1U-LI

Installation Guide. Marine Filter SURT023M SURT024M

Smart-UPS RT External Battery Pack Stack/Rack-Mount 6U

Smart-UPS RC External Battery Pack Tower/Rack-Mount 4U

Installation and Operation

Smart-UPS RC External Battery Pack Tower/Rack-Mount 4U

User Manual. Smart-UPS. Uninterruptible Power Supply 750/1000 VA. 100/120/230 Vac. Rack Mount 1U

User Manual. Smart-UPS. Uninterruptible Power Supply. 1000/1500 VA 100/120/230 Vac. 750XL/1000XL VA 120/230 Vac. Tower

CTFRP Series Power Supplies

Operation Manual. Smart-UPS C. Uninterruptible Power Supply 1000/1500/2000/3000 VA. 120/230 Vac. Tower. su0813a

SUA1000I-IN / SUA1500I-IN 230 VAC

User Manual Easy UPS On-Line SRV Series 1000VA, 2000VA, 3000VA

User Manual Easy UPS On-Line SRVS Series Rack-Mount 1000VA, 2000VA, 3000VA

Installation and Operation

Operation Manual. Smart-UPS. Uninterruptible Power Supply. Rack-Mount 1U. 1200/1500 VA 100/120/230 Vac

APC Smart-UPS 2200/3000 VA 230 VAC. Uninterruptible Power Supply

! "! User Manual Myers Power Products CTEP/G Manual 6/2009

Installation and Operation

Technical Specifications. Symmetra PX kw 208 V

Installation and Operation

Operation Manual. Smart-UPS. Uninterruptible Power Supply. 750/1000/1500/2200/3000 VA Tower 100/120/230 Vac. 500 VA Tower 100 Vac

Installation and Operation

Installation and Operation Manual Back-UPS BR1000-CH

Power Distribution Units

Power Distribution Units AP9560 & AP9561

Installation and Operation

Installation and Operation Manual Back-UPS BX1100CI-CN

Technical Specifications

Safety and General Information

Installation and Operation Manual Smart-UPS Tower 220/230/240 Vac SRC1000ICCIND; SRC1000UXIND

Operation Manual. Smart-UPS Uninterruptible Power Supply. 1000/1500/2200/3000 VA 220 Vac. Rack-Mount 2U

10 Year Limited Warranty

Electrical Installation

Installation and Operation

Operation Manual. Smart-UPS Uninterruptible Power Supply. Rack-Mount 2U. 750/1000/1500 VA 120/230 Vac VA 120 Vac. 100/120/208/230 Vac

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

Installation and Operation

XPC-EBP64 External Battery Pack User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

Operation Manual. Smart-UPS. Uninterruptible Power Supply VA Short-depth Rack-Mount with Lithium-ion batteries. 120 Vac

Installation and Operation Back-UPS BX550CI-CN

Power. On Your Terms.

Operation Manual. Smart-UPS Uninterruptible Power Supply. 750/1000/1500/2200/3000 VA 100/120/230 Vac. 500 VA 100 Vac. Tower

Start UP Guide. Symmetra LX Tower Rack-Mount. UPS Models 200 V, 4-8 kva 208/240 V, 4-8 kva 220/230/240 V, 4-8 kva

Operation Manual. Smart-UPS. Uninterruptible Power Supply. 750/1000/1500 VA Short-depth Rack-Mount with Lithium-ion batteries.

User Manual Easy UPS BV Series 500VA, 650VA, 800VA, 1000VA Safety and General Information

PVI 60KW, PVI 82KW, PVI 95KW

User Manual. English. APC Smart-UPS. 750/1000/1500 VA 100/120/230 Vac 2U Rack-Mount Uninterruptible Power Supply

Installation and Operation Manual Back-UPS BX800CI-ZA/BX1100CI-ZA

SUNTURA SOLAR TRACKER

User Manual Back-UPS BX650CI-MS 230 Vac with AVR

WARRANTY POLICY. Grid-Tied Photovoltaic Inverters. Revision D. 2014, Solectria Renewables, LLC DOCIN

SUNTURA HD SOLAR TRACKER

MM-AVR UPS Series User s Manual

User Manual Smart-UPS On-Line SRC1KI-IN, SRC1KUXI

AC/DC Powered Peak Detection Fast Charger for 4- to 8-Cell Ni-Cd & Ni-MH Batteries

DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL

Cabling for power, control, and video must be run to the installation site before the mount is installed.

Installation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount

EQUIPMENT Instructions. Loctite Pneumatic 300 ml Cartridge Dispenser Part Number

Installation and Operation Manual Back-UPS BR800/1100CI-IN

Outdoor Nema Enclosure For Dotworkz CoolDome Power Supply Product Code: NM-CDPS. User Manual

n Operator s Manual n Redundant Control Unit FOR CFR UNINTERRUPTIBLE POWER SUPPLIES FROM ALPHA TECHNOLOGIES

VANGUARD A EZ INSTALL OPERATOR S MANUAL

APC Smart-UPS RT UX. User s Manual. Models SURT1000UXI and SURT2000UXI 220/230/240 Tower/Rack Mount Uninterruptible Power Supply.

Reach ins, Freeezers & Refrigerators Installation & Operation Manual

II DISTRIBUTION & SUBSTATION TYPE C

7.3L POWERSTROKE BANJO BOLT KIT Fits L Powerstroke Diesel. Installation Guide

Operation Manual. English. APC Smart-UPS VA 3U Rack and Stack Uninterruptible Power Supply 230 Vac , Revision 1 12/00

User s Manual. English. APC Smart-UPS RT. 3000/5000 VA VAC 3U Tower/Rack Mount Uninterruptible Power Supply

DUAL WIDEBAND AIR/FUEL RATIO GAUGE Product Numbers: GS-W702W_Dual, GS-C702W_Dual, GS-T702W_Dual

ActuLink ABS Module - ABS-MOD-400

Installation / Operation Instructions Sunnex ORION Series Exam Lights

Operation Manual. Smart-UPS C. Uninterruptible Power Supply. 1000/1500 VA Tower / Rack-Mount 2U. 120 Vac/230 Vac

Operation Manual. Smart-UPS. Uninterruptible Power Supply. 750/1000/1500/2200/3000 VA Tower / Rack-Mount 2U. 120 Vac/230 Vac

Manufacturing Facility is ISO9001:2000. Welded Steel Pipe Conform to ASTM A53. Threads Conform to ASME B1.20.1

Operation and Maintenance

Kit INSTALLATION GUIDE. For maximum effectiveness and safety, please read these instructions completely before proceeding with installation.

3000VA 120/208/230VAC

This document describes:

Operating and Installation Instructions

Model AS-RC3260 TV Cart. Rolling Cart for Audio Mount System & Flat Panel TVs

EPS Technical Specifications 06/2015.

END USER TERMS OF USE

TRACKS BUILT TO LAST. AGRICULTURAL MADE FOR AGRICULTURE. PROVEN TO PERFORM. FOR HIGH-HORSEPOWER TRACTORS

User s Manual. ClipperCreek, Inc. Innovative Infrastructure for Electric and Hybrid Vehicles. Model PCS-15

IAQ-CALC INDOOR AIR QUALITY METER MODEL 7515

Model T2642 Wall Mount. Television Wall Mount with Tilt Option

Installation Guide Smart-UPS On-Line SRT1000/SRT1500 XLA Tower/Rack-Mount

Type Maxi Mix III Rotary Shaker

60 PSI Boost Gauge. For Product Numbers: MT-DV01_60, MT-WDV01_60

INSTALLATION/OWNER'S MANUAL DP " Woofer in Enclosure

Installation and Operation Guide for PD5100 Automatic Transfer Switch

USER GUIDE. PowerRite XT UPS. 400 VA, and 600 VA.

ml Dual Cartridge Dispenser 10:1 B Style Cartridge ml Dual Cartridge Dispenser 1:1 & 2:1 B Style Cartridge

STAINLESS STEEL FORGED FITTINGS 3000lb 304/304L & 316/316L Forged Stainless Steel Fittings Product Specifications

Do not install and/or operate this safety product unless you have read and understand the safety information contained in this manual.

Users Guide for Ac-sync

Transcription:

Broadband PowerShield CP27U Models User Manual 990-2366C 04/2016

Chapter 1: General Information The PowerShield provides a power source for broadband telephony, Fiber-to-the-Home/Premise (FTTH/P), and other direct current (DC) equipment/applications. Safety This manual contains important instructions that should be followed during installation and maintenance of the APC equipment and batteries. It is intended for APC customers that set up, install, relocate, or maintain APC equipment. Changes and modifications to this unit not expressly approved by APC could void the warranty. Failure to observe this warning may result in serious injury, death, or damage to the equipment. Electrical Warnings Do not work alone under hazardous conditions. Servicing the PowerShield may require the removal of protective covers, as well as connected utility power. Use extreme caution during these procedures. Check that the power cord(s), plug(s), and sockets are in good condition. Replacement of fuses or other parts must be with identical types and ratings. Substitution of nonidentical parts may cause safety and fire hazards. Battery Warning Danger of explosion if the battery is incorrectly connected or replaced. Use only APC replacement batteries. Unpacking Inspect the unit upon receipt. Notify the shipping carrier or product supplier if there is damage. The packaging is recyclable; save it for reuse or dispose of it properly. Check the package contents. The package contains the enclosure, the battery (to be installed), one power cord, and the product documentation. 1

Specifications General Model Number CP27U13 Input Output Maximum Signal Voltage 100-240 V 50/60 Hz 1.0 A 27 W 13 VDC 12VDC nominal Maximum Signal Current Battery Type 30 V 5 ma 12 V, 7.2 AHr Spill-Proof, Maintenance Free, Sealed Lead Acid Environmental Operating Temperature -4º F to 122º F (-20º C to 50º C) Operating Humidity Maximum Operating Elevation 10,000 ft (3,000 m) Maximum Storage Elevation 50,000 ft (15,000 m) 5 to 95% noncondensing within enclosure Storage Temperature -4º F to 122º F (-20º C to 50º C) Battery lifetime is reduced with prolonged storage in high temperatures (>25º C). Physical Height x Width x Depth PowerShield PowerShield carton Weight PowerShield PowerShield with package materials 7.5 x 9.5 x 3 in (19 x 24 x 7.6 cm) 13.5 x 13.5 x 4.5 in (34 x 34 x 11 cm) 7.15 lbs (3.25 kg) 9 lbs (4 kg) 2

Chapter 2: Installation Enclosure Installation Indoor Use Only Install the PowerShield in a protected area that is free of excessive dust and has adequate airflow. Do not operate the PowerShield where the temperature and humidity are outside the specified limits. See Specifications. Use screws that are appropriate for the weight of this unit and the mounting surface material. See Specifications. Battery Cover Release Tabs 3

Battery Installation Red Cable Positive Terminal Black Cable Negative Terminal Battery Cover Release Tabs 4

Connect Equipment and Power The PowerShield battery charges when it is connected to utility power. The battery charges fully during the first eight hours of normal operation. Do not expect full battery run capability during this initial charge period. Utility Power Cord Inlet Output Power and Communication Signals Optional Runtime Extension Connector 1. Connect the PowerShield to the application equipment (example: FTTH/P Optical Network Terminal) via the seven-pin output connector, using the appropriate cable (must be ordered separately). See www.apc.com for a list of available output cables. 2. Plug the PowerShield power cord into the utility power cord inlet and then into the wall outlet. Do not overload the wall outlet or circuit. Cold Start Feature: Upon installation of a charged battery, power will immediately be applied to the unit even when utility power is not present. Attention: To disconnect from utility power, remove the plug from the wall outlet. Optional Runtime Extension The runtime may be extended by adding the external battery CP20B12BP. 5

Chapter 3: Operation Status Indicators and Features Front Panel Status Indicators Indicator Utility Output Replace Battery/ Alarm Silence / Description Solid green indicates the unit is on utility power. Solid yellow indicates that utility power is not present and the unit is on battery power. Flashing green LED indicates the unit is fast charging. Green indicates the unit is working properly and DC output power is provided by the battery or the utility power. Red indicates that the battery must be replaced or that the battery is disconnected. See Battery Replacement. Pressing this button will silence the audible alarm. See Alarm Silence Button. Automatic Self-Test The unit automatically performs a self-test 31 hours after initial installation. Following this, a battery self-test will occur every 30 days. See Alarm Silence Button for manual self-test information. Audible Alarm Explanation On Battery Low Battery Voltage Replace Battery Description Four beeps in four seconds will be emitted one time only. This alarm will sound when the utility power is lost and the unit goes on battery power. Every five minutes, four beeps in four seconds will be emitted. This alarm will sound when operating on battery and the battery voltage has dropped below threshold, indicating that less than 20% of available runtime remains. Every fifteen minutes, there will be a quarter-second beep when the battery fails the automatic self-test. 6

Alarm Silence Button The audible alarms may be silenced by utilizing the dual function Replace Battery/Alarm Silence LED/button /. Function Replace Battery Temporarily Enable/Disable Replace Battery Permanently Enable/Disable Battery Self-Test Enable/Disable Button Operation (Press and hold for:) Description <4 seconds If the alarm has been silenced, the unit will emit one quick beep. If the alarm has been enabled, two quick beeps will be emitted. 8-12 seconds If the alarm has been silenced, the unit will emit one quick beep. If the alarm has been enabled, two quick beeps will be emitted. 4-8 seconds If the self-test has been enabled, three beeps will be emitted. If the self-test cannot be enabled, a single beep will be emitted.* If the battery self-test has been canceled, the unit will emit four beeps. *A battery self-test cannot be enabled unless the following conditions have been met. 1. Battery has been charged for at least 31 hours. 2. The unit has been on utility power for more than 12 hours. 3. Temperature is between 0 and 50 C. Output Power and Communication Signals The PowerShield communication signals are isolated from its internal circuitry via by open collector opto-coupled transistors. The connection labeled Signal Return is a common return point for all communication signals. In the typical application, the attached equipment digital ground connects to Signal Return, and pull-up resistors turn the open collector signals into logic levels. +Voltage output Voltage output Signal return. Low when operating from utility line. Open when operating from battery. Low when battery is charged. Open when battery fails the Self-Test. Low when battery is present. Open when battery is missing. Low when battery is near full charge capacity. Open when operating from a battery with less than 20% of available runtime remaining. 7

Chapter 4: Maintenance, Service, Contact Information, and Warranty Battery Replacement This unit has an easy to replace battery. Battery replacement can be performed while the unit and connected equipment are operating. During a self-test, battery removal and replacement are not recommended. For self-test disabling, see Alarm Silence Button. Replace the used battery with APC replacement battery RBC2. See your dealer or refer to the APC Web site, www.apc.com, for information on replacement batteries. For battery replacement, see Battery Installation. Once the battery is disconnected, the connected equipment is not protected from power outages. Be sure to deliver used batteries to a recycling facility found on the Used Battery Return Facilities list included with RBC2. Service If the unit requires service, do not return it to the dealer. Follow these steps: 1. Contact APC Customer Support through the APC web site at www.apc.com. a) Note the product model number, the serial number, and the date of purchase. b) Call APC Customer Support and a technician will attempt to solve it over the phone. If this is not possible, the technician will issue a Returned Material Authorization Number (RMA#). c) If the product is under warranty, repairs are free. If not, there is a repair charge. d) Service procedures and returns may vary internationally. Refer to the APC web site for country specific instructions. 2. Pack the unit properly to avoid damage in transit. Never use Styrofoam beads for packaging. Damage sustained in transit is not covered under warranty. 3. Before shipping, always disconnect all battery modules. 4. Write the RMA# provided by Customer Support on the outside of the package. 5. Return the unit by insured, prepaid carrier to the address provided by Customer Support. 8

Limited Factory Warranty Schneider Electric IT Corporation (SEIT), warrants its products to be free from defects in materials and workmanship for a period of two (2) years from the date of purchase. The SEIT obligation under this warranty is limited to repairing or replacing, at its sole discretion, any such defective products. Repair or replacement of a defective product or parts thereof does not extend the original warranty period. This warranty applies only to the original purchaser who must have properly registered the product within 10 days of purchase. Products may be registered online at warranty.apc.com. SEIT shall not be liable under the warranty if its testing and examination disclose that the alleged defect in the product does not exist or was caused by end user or any third person misuse, negligence, improper installation, testing, operation or use of the product contrary to SEIT recommendations or specifications. Further, SEIT shall not be liable for defects resulting from: 1) unauthorized attempts to repair or modify the product, 2) incorrect or inadequate electrical voltage or connection, 3) inappropriate on site operation conditions, 4) Acts of God, 5) exposure to the elements, or 6) theft. In no event shall SEIT have any liability under this warranty for any product where the serial number has been altered, defaced, or removed. EXCEPT AS SET FORTH ABOVE, THERE ARE NO WARRANTIES, EXPRESS OR IMPLIED, BY OPERATION OF LAW OR OTHERWISE, APPLICABLE TO PRODUCTS SOLD, SERVICED OR FURNISHED UNDER THIS AGREEMENT OR IN CONNECTION HEREWITH. SEIT DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY, SATISFACTION AND FITNESS FOR A PARTICULAR PURPOSE. SEIT EXPRESS WARRANTIES WILL NOT BE ENLARGED, DIMINISHED, OR AFFECTED BY AND NO OBLIGATION OR LIABILITY WILL ARISE OUT OF, SEIT RENDERING OF TECHNICAL OR OTHER ADVICE OR SERVICE IN CONNECTION WITH THE PRODUCTS. THE FOREGOING WARRANTIES AND REMEDIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES AND REMEDIES. THE WARRANTIES SET FORTH ABOVE CONSTITUTE SEIT SOLE LIABILITY AND PURCHASER EXCLUSIVE REMEDY FOR ANY BREACH OF SUCH WARRANTIES. SEIT WARRANTIES EXTEND ONLY TO ORIGINAL PURCHASER AND ARE NOT EXTENDED TO ANY THIRD PARTIES. IN NO EVENT SHALL SEIT, ITS OFFICERS, DIRECTORS, AFFILIATES OR EMPLOYEES BE LIABLE FOR ANY FORM OF INDIRECT, SPECIAL, CONSEQUENTIAL OR PUNITIVE DAMAGES, ARISING OUT OF THE USE, SERVICE OR INSTALLATION OF THE PRODUCTS, WHETHER SUCH DAMAGES ARISE IN CONTRACT OR TORT, IRRESPECTIVE OF FAULT, NEGLIGENCE OR STRICT LIABILITY OR WHETHER SEIT HAS BEEN ADVISED IN ADVANCE OF THE POSSIBILITY OF SUCH DAMAGES. SPECIFICALLY, SEIT IS NOT LIABLE FOR ANY COSTS, SUCH AS LOST PROFITS OR REVENUE, WHETHER DIRECT OR INDIRECT, LOSS OF EQUIPMENT, LOSS OF USE OF EQUIPMENT, LOSS OF SOFTWARE, LOSS OF DATA, COSTS OF SUBSTITUANTS, CLAIMS BY THIRD PARTIES, OR OTHERWISE. 9

NOTHING IN THIS LIMITED WARRANTY SHALL SEEK TO EXCLUDE OR LIMIT SEIT LIABILITY FOR DEATH OR PERSONAL INJURY RESULTING FROM ITS NEGLIGENCE OR ITS FRAUDULENT MISREPRESENTATION OF TO THE EXTENT THAT IT CANNOT BE EXCLUDED OR LIMITED BY APPLICABLE LAW. To obtain service under warranty you must obtain a Returned Material Authorization (RMA) number from customer support. Customers with warranty claims issues may access the SEIT worldwide customer support network through the APC web site: www.apc.com. Select your country from the country selection drop down menu. Open the Support tab at the top of the web page to obtain information for customer support in your region. Products must be returned with transportation charges prepaid and must be accompanied by a brief description of the problem encountered and proof of date and place of purchase. APC by Schneider Electric Worldwide Customer Support Customer support for this or any other APC by Schneider Electric product is available at no charge in any of the following ways: Visit the APC by Schneider Electric web site, www.apc.com to access documents in the APC Knowledge Base and to submit customer support requests. www.apc.com (Corporate Headquarters) Connect to localized APC by Schneider Electric web site for specific countries, each of which provides customer support information. www.apc.com/support/ Global support searching APC Knowledge Base and using e-support. Contact the APC by Schneider Electric Customer Support Center by telephone or e-mail. Local, country specific centers: go to www.apc.com/support/contact for contact information. For information on how to obtain local customer support, contact the APC by Schneider Electric representative or other distributor from whom you purchased your APC by Schneider Electric product. 2016 APC by Schneider Electric. APC, the APC logo are owned by Schneider Electric Industries S.A.S. or their affiliated companies. All other trademarks are property of their respective owners. 10