H1 Axial Piston Pump Size 147/165, Single. Technical Information

Similar documents
H1 Axial Piston Pump Size 115/130, Single. Technical Information

H1 Axial Piston Tandem Pumps Size 045/053

H1 Axial Piston Pump Size 147/165, Single

H1 Axial Piston Pump Size 045/053, Single. Technical Information

T1P Transit Mixer Axial Piston Pump Size 069/089

Technical Information Series 45 G Frame powersolutions.danfoss.com

H1 Axial Piston Tandem Pumps Size 045/053/060/068

H1 Axial Piston Single Pumps Size 147/165

DH Technical Information. Versions. Versions

H1T 045/053/060/068 H1 Axial Piston Tandem Pumps

Distribuíção, revenda emanutenção. CatálogosOnline. (11) (11)

H1 Axial Piston Single Pumps Size 147/165

H1 Axial Piston Single Pumps Size 147/165

Series 20 Axial Piston Pumps. Technical Information

Series 20 Axial Piston Pumps. Technical Information

H1 Axial Piston Single Pumps Size 045/053

H1B Motor Two-Position Control E1, E2

OMT Series 2. Orbital Motors. Service Manual

H1 Axial Piston Single Pumps Size 045/053

Closed Circuit Axial Piston Pumps H1 115/130 cc

Series TMM Axial Piston Motor. Technical Information

H1 Axial Piston Single Pumps Size 089/100

OMEW Standard and with Low Speed Option. Orbital Motors. Technical Information

H1B Motor Electric Two-Position Control T1, T2

MCX106A Hall Effect Level Sensor. Technical Information

H1 Pump Filter Bypass Sensor

OMR, OMR C, and OMRW N Series 5 and 6. Repair Instructions

OMH. Repair Instructions

OMP, OMP C, OMPW, and OMPW N Series 7 and 8. Repair Instructions

Series 51 Motor Electrohydraulic Two-Position Controls T1, T2

Steering Priority Valve OLS 160

Technical Information Axial Piston Motors Series 20 powersolutions.danfoss.com

Series 51-1 Motor Pressured Compensated Controls TA

OML and OMM Orbital Motors. Repair Instructions

MP1 Axial Piston Pumps Size 28/32, 38/45

Sensor Steering Angle Sensor Absolute (SASA)

Closed Circuit Axial Piston Pump DDC20

Parts Manual Closed Circuit Axial Piston Pump DDC20 powersolutions.danfoss.com

Quick Reference Parts Manual Variable Displacement Motor Series 20, series powersolutions.danfoss.com

MP1 Axial Piston Pumps Size 28/32, 38/45

Technical Information Series 45 H Frame powersolutions.danfoss.com

Orbital Motors OMEW Standard and with Low Speed Option

MAKING MODERN LIVING POSSIBLE. Technical Information. Orbital Motors TMVW. powersolutions.danfoss.com

Series 20 Axial Piston Motors. Technical Information

Proportional Valve Group PVG 120

OSPB, OSPC, OSPF, OSPD, OSPQ, OSPL Load Sensing Steering Units. OLS Priority Valves. OSQ Flow Amplifiers. Technical Information

Series 20 Axial Piston Motors. Technical Information

Directional Control Valve Model Technical Information. Phased Out OUT BASE BKT CYL ROD

Steering Unit Type OSPB and OSPC Type ON and CN

MCX104A DC Microsyn Level Sensor. Technical Information

Product Reliability Data (MTTF) for S90P

Proportional Valve Group PVG 128/256

OSPB, OSPC, OSPF, OSPD, OSPQ, OSPL Load Sensing Steering Units. OLS Priority Valves. OSQ Flow Amplifiers. Technical Information

OSPB, OSPC, OSPF, OSPD, OSPQ, OSPL Load Sensing Steering Units. OLS Priority Valves. OSQ Flow Amplifiers. Technical Information

Series 90 Axial Piston Motors. Technical Information

MAKING MODERN LIVING POSSIBLE. Service Manual. Steering OSPM. powersolutions.danfoss.com

Orbital Motors DH and DS

Technical Information Orbital Motors DH and DS powersolutions.danfoss.com

Product Reliability Data (MTTF) for H1P

S1X Generic Speed Control System

OMR Technical Information Versions

Phased Out Products. Proportional Valve Group PVG 83. Tech Note MAKING MODERN LIVING POSSIBLE

Orbital Motors Type OMP, OMR and OMH. Technical Information

Variable Displacement Pumps MP1

Series T90 Transit Mixer Drive System

Steering Valve EHPS and EHPS with OLS 320

MAKING MODERN LIVING POSSIBLE. Phased Out Products. Technical Information. Level Controller. powersolutions.danfoss.com

Service Parts Manual M25 Axial Piston Motor Series 40 powersolutions.danfoss.com

Series ASC Anti Spin Control Valve

Series 90 Axial Piston Pumps. Technical Information

Transit Mixer Axial Piston Motor Size 070/084/089

Sensors KS10201 Microsyn Level Sensor

Faster. Count on availability when you need it most H1B Bent Axis Motors Rapid Delivery Center. time to market. powersolutions.danfoss.

Orbital Motors Seal Kits

Series 90 Axial Piston Pumps. Technical Information

Parts Manual Series cc Axial Piston Motor powersolutions.danfoss.com

Parts Manual Axial Piston Motors Series 40 MMF044D and MMV044D powersolutions.danfoss.com

Series 51 - HZ, HA, HB, HE, HS, H1, H2, K1, K2, HP, HC, J1, J2, J3, J4, JA Hydraulic Proportional Controls

L and K Frame Variable Motors. Technical Information

Orbital Motors OMS, OMT and OMV Orbital Motors

H1 Bent Axis Variable Displacement Motors Frame Size 080 Frame Size 110. Technical Information

Directional Control Valve

Series 90 Axial Piston Pumps. Technical Information

Series 90 Axial Piston Pumps

Orbital X Modular Program

Series 40 M25 Axial Piston Pump. Service Parts Manual

Series 45 Axial Piston Open Circuit Pumps Technical Information

Transit Mixer Drives System Series TM

Sensors ACX104B Potentiometer Rotary Position Sensor

Loop Flushing Valve. Lenntech. Technical Information. Tel Fax

Closed Circuit Axial Piston K and L Frame Variable Motors, SAE Mount

H1 Axial Piston Pumps Single and Tandem

Series 45 Axial Piston Open Circuit Pumps Technical Information Frame F

Series 40 Axial Piston Motors

Hydrostatic Steering Unit Type OSPB, OSPC and OSPF. Service Manual

Series 40 Direct Displacement Pumps

Closed Circuit Axial Piston Pumps H1 45/53/60/68 Tandem

P90 VARIABLE DISPLACEMENT PUMP T E C H N I C A L C A T A L O G

Technical Information. Steering Unit OSPU. powersolutions.danfoss.com

Series 45 Open Circuit Axial Piston Pumps. Technical Information. Displacement Piston. Swashplate. Piston. Tapered Roller Bearing

Transcription:

H1 Axial Piston Pump Size 147/165, Single Technical Information

Revisions Revision History Table of revisions Date Page Changed Rev 30 Jul, 2009 First edition AA Jul, 2010 4-6, 10, 12-13 New EC directive BA Dec 2012 Various Pressure changed CA Jan 2013 9 147 cm 3 only deleted CB Further available literature Description SD order number Overview, H1 Axial Piston Pumps, Single and Tandem L1012919 Basic Information, H1 Axial Piston Pumps, Single and Tandem 11062168 H1 Axial Piston Pump, Size 045/053, Single 11063344 H1 Axial Piston Pump, Size 045/053, Tandem 11063345 H1 Axial Piston Pump, Size 060/068, Single 11071685 H1 Axial Piston Pump, Size 069/078, Single 11062169 H1 Axial Piston Pump, Size 089/100, Single 11069970 H1 Axial Piston Pump, Size 115/130, Single 11063346 11063347 H1 Automotive Control for Single Axial Piston Pumps 045-130 cc L1223856 Complementary Products External Remote Charge Pressure Filter 11064579 Speed and Temperature Sensor 11046759 Pressure Sensor L1007019 Hydraulic Fluids, Hydraulic Fluids and Lubricants 520L0463 Experience with Biodegradable Hydraulic Fluids 520L0465 Design Guideline for Hydraulic Fluid Cleanliness 520L0467 Application Information Applications Manual, Section 1, Selection of Driveline Components BLN-9885 Applications Manual, Section 2, Pressure and Speed Limits for Hydraulic Units BLN-9884 Applications Manual, Section 4, Transmission Circuit Recommendations BLN-9886 PLUS+1 COMPLIANT (Electrical Installation) H1 Electrical Displacement Control (EDC) 11022744 H1 3-position (FNR) Electric Control 11025001 H1 Non-Feedback Proportional Electric (NFPE) Control 11025002 Service Manuals H1 Axial Piston Pump, Size 045/053, Single 520L0958 H1 Axial Piston Pump, Size 045/053, Tandem 520L0928 H1 Axial Piston Pump, Size 069/078/089/100/115/130/147/165, Single 520L0848 T000 143E Front cover illustrations: F301 350, P005 265 2 11063347 Rev CB Jan 2013 2013 Sauer-Danfoss. All rights reserved. Sauer-Danfoss accepts no responsibility for possible errors in catalogs, brochures and other printed material. Sauer -Danfoss reserves the right to alter its products without prior notice. This also applies to products already ordered provided that such alterations can be made without affecting agreed specifications. All trademarks in this material are properties of their respective owners. Sauer-Danfoss, the Sauer-Danfoss logotype, the Sauer-Danfoss S-icon, PLUS+1, What really matters is inside and Know-How in Motion are trademarks of the Sauer-Danfoss Group.

Content Technical Specifications General Technical Specifications Dimensions Charge Pump Installation Drawings Technical Specifications... 4 Shaft Loads... 6 Mounting Flange Loads... 7 Electrical Displacement Control (EDC) Options A2 (12 V)/A3 (24 V)...10 Manual Over Ride (MOR)...12 Displacement Limiter...13 Input Shafts...14 Option G3, ISO 3019-1, outer dia 44 mm-4 (SAE D, 13 teeth)...14 Option G2, ISO 3019-1, outer dia 44 mm-4 (SAE D, 27 teeth)...14 Option F3, ISO 3019-1, Code 44-3, Diameter 44.5 taper 1:8, without key and no through-hole in the end of the shaft...15 Auxiliary Mounting Pads...16 Option H2, ISO 3019-1, flange 82-2 (SAE A, 9 teeth)...16 Option H1, ISO 3019-1, flange 82-2 (SAE A, 11 teeth)...17 Option H3, ISO 3019-1, flange 101-2 (SAE B, 13 teeth)...18 Option H5, ISO 3019-1, flange 101-2 (SAE B-B, 15 teeth)...19 Option H6, ISO 3019-1, flange 127-4 (SAE C, 14 teeth)...20 Option H5, ISO 3019-1, flange 152-4 (SAE D, 13 teeth)...21 Charge Pump...22 Port Description...24 Dimensions...26 Controls...29 Displacement limiters...31 Displacement limiters...32 11063347 Rev CB Jan 2013 3

Technical Specifications Technical Specifications For definitions of the following specifications, see Basic Information 11062168, Operating parameters. General specifications Design Direction of rotation Pipe connections Recommended installation position Auxiliary cavity pressure Axial piston pump of cradle swashplate design with variable displacement Clockwise, counterclockwise Main pressure ports: ISO split flange boss Remaining ports: SAE straight thread O-ring boss Pump installation position is discretionary, however the recommended control position is on the top or at the side, with the top position preferred. If the pump is installed with the control at the bottom, flushing flow must be provided through port M14 located on the EDC, FNR and NFPE control. Vertical input shaft installation is acceptable. If input shaft is at the top 1 bar case pressure must be maintained during operation. The housing must always be filled with hydraulic fluid. Recommended mounting for a multiple pump stack is to arrange the highest power flow towards the input source. Consult Sauer-Danfoss for nonconformance to these guidelines. Will be inlet pressure with internal charge pump. For reference see operating parameter on next page. Will be case pressure with external charge supply. Please verify mating pump shaft seal capability. T000 126E Technical data Feature Unit Size 147 Size 165 Displacement* cm 3 [in 3 ] 147.2 [8.98] 165.1 [10.08] Flow at rated (continuous) speed* l/min [US gal/min] 441 [117] 495 [131] Torque at maximum displacement (theoretical)* Mass moment of inertia of rotating components Mass [weight] dry (without charge pump or auxiliary mounting flange) N m/bar [lbf in/ 1000psi] 2.34 [1430] 2.63 [1605] kg m 2 [slug ft 2 ] 0.027 [0.0199] kg [lb] 96.0 [211.0] Oil volume liter [US gal] 3.0 [0.8] Mounting flange ISO 3019-1 flange 152-4 (SAE D) Input shaft outer diameter, splines and tapered shafts Auxiliary mounting flange with metric fasteners, shaft outer diameter and splines Suction port Main port configuration Case drain ports L2, L4 (SAE O-ring boss) Other ports Customer interface threads ISO 3019-1, outer dia 44 mm - 4 (SAE D, 13 teeth) ISO 3019-1, outer dia 44 mm - 4 (SAE D, 27 teeth) Conical keyed shaft end similar to ISO 3019-1 code 44-3, taper 1:8 ISO 3019-1, flange 82-2, outer dia 16 mm - 4 (SAE A, 9 teeth) ISO 3019-1, flange 82-2, outer dia 19 mm - 4 (SAE A, 11 teeth) ISO 3019-1, flange 101-2, outer dia 22 mm - 4 (SAE B, 13 teeth) ISO 3019-1, flange 101-2, outer dia 25 mm - 4 (SAE B-B, 15 teeth) ISO 3019-1, flange 127-4, outer dia 32 mm - 4 (SAE C, 14 teeth) ISO 3019-1, flange 152-4, outer dia 44 mm - 4 (SAE D, 13 teeth) Port ISO 11926-1 1 5 / 8-12 (SAE O-ring boss) 31.5-450 bar split flange boss per ISO 6162, M12x1.75 Port ISO 11926-1 1 5 / 16-12 (SAE O-ring boss) SAE O-ring boss. See installation drawings at the back of this manual. Metric fasteners T301 020E 4 11063347 Rev CB Jan 2013

Technical Specifications Technical Specifications (continued) For definitions of the following specifications, see Basic Information 11062168, Operating parameters. Operating parameters Feature Unit Size 147 Size 165 Minimum for internal charge supply at minimum charge pressure. Performance (pressure and displacement) may be limited 500 due to limited control pressure Minimum for external charge supply at minimum charge pressure. Full performance Input speed (pressure and displacement) possible at minimum min -1 (rpm) 500 charge and control pressure supply Minimum for full performance (pressure and displacement) for internal charge supply at 1200 minimum charge and control pressure Rated 3000 Maximum 3100 Maximum working pressure 450 [6525] System pressure Maximum pressure 480 [6960] bar [psi] Maximum low loop 45 [650] Minimum low loop pressure 10 [145] Charge pressure Minimum 16 [232] bar [psi] Maximum 34 [493] Control pressure Minimum (at corner power for EDC) 17 [247] bar [psi] Maximum 40 [580] Rated 0.7 [9] Charge pump inlet bar (absolute) [in Hg vacuum] Minimum (cold start) 0.2 [24] pressure Maximum bar [psi] 4.0 [58] Case pressure Rated 3.0 [44] bar [psi] Maximum 5.0 [73] Lip seal external pressure Maximum bar [psi] 0.4 [5.8] T000 173E Fluid specifications Feature Unit Intermittent 1) 5 [42] Viscosity Minimum 7 [49] mm 2 /s [SUS] Recommended range 12-80 [66-370] Maximum 1600 [7500] Minimum (cold start) 3) -40 [-40] Temperature Recommended range 60-85 [140-185] C [ F] range 2) Rated 104 [220] Maximum intermittent 1) 115 [240] Cleanliness per ISO 4406 22/18/13 Filtration Efficiency (charge pressure filtration) β (recommended β-ratio 15-20 = 75 (β 10 10) Efficiency (suction and return line filtration) minimum) β 35-45 = 75 (β 10 2) Recommended inlet screen mesh size µm 100 125 1) Intermittent = Short term t < 1min per incident and not exceeding 2 % of duty cycle based load-life 2) At the hottest point, normally case drain port 3) Cold start = Short term t < 3min, p 50 bar [725 psi], n 1000 min -1 (rpm) T000 129E 11063347 Rev CB Jan 2013 5

General Technical Specifications Shaft Loads External radial shaft loads H1 pumps are designed with bearings that can accept some external radial loads. The external radial shaft load limits are a function of the load position and orientation, and the operating conditions of the unit. External radial shaft loads impact lifetime. For lifetime calculations please contact Sauer-Danfoss representative. The maximum allowable radial load (R e ) is based on the maximum external moment (M e ) and the distance (L) from the mounting flange to the load. It may be determined using the following table and formula. R e = M e / L Radial load position 0 R e L R e 270 R e 90 R e M e M e = Shaft moment L = Flange distance R e = External force to the shaft 180 R e P003 318E Thrust loads should be avoided. Contact factory in the event thrust loads are anticipated. 6 11063347 Rev CB Jan 2013

General Technical Specifications Bearing Life (continued) Maximum external shaft load based on shaft deflection Unit Size 147/165 External radial moment M e Nm [lbf in] 140 [1240] All external shaft loads affect bearing life. In applications with external shaft loads, minimize the impact by positioning the load at 0 or 180 as shown in the figure. T301 022E Sauer-Danfoss recommends clamp-type couplings for applications with radial shaft loads. Contact your Sauer-Danfoss representative for an evaluation of unit bearing life if you have continuously applied external loads exceeding 25 % of the maximum allowable radial load (R e ) or the pump swashplate is positioned on one side of center all or most of the time. Mounting Flange Loads H1 single pump front flange load The moments shown below apply for control orientation top or side (see table and figures). Mounting flange load Unit Size 147/165 Rated moment M R Nm [lbf in] 6500 [57 500] Shock load moment M S 16 300 [144 000] T301 023E M R M S P001 916 For calculation details refer to H1 Pump Basic Information Manual 11062168, section Mounting Flange Loads. 11063347 Rev CB Jan 2013 7

General Technical Specifications Model Code A B D F E G H J K M N S T V W X Y H1 P C G A B D F E G Displacement 147 147.2 cm³ [8.98 in³] 165 165.1 cm³ [10.08 in³] Rotation L Left hand (counter clockwise) R Right hand (clockwise) Product version C Revision code Control A2 Electric Displacement Control (EDC) 12V, Deutsch connector A3 Electric Displacement Control (EDC) 24V, Deutsch connector A4 Electric Displacement Control (EDC) 12V, Deutsch connector, Manual override A5 Electric Displacement Control (EDC) 24V, Deutsch connector, Manual override Orifices C1 Orifices, 0.8 mm in servo supply 1 and 2, recommended for propel applications C2 Orifices, 1.3 mm in servo supply 1 and 2 (Standard), recommended for propel applications C3 No orifice, recommended for non-propel applications Displacement limiters N None B Adjustable externally (align with option Y: Settings for adjustment, if applicable) Match with below options (K) Match with below options (T) D3 D5 D6 D7 D8 D9 H J Endcap options Auxiliary mounting pad None, ISO 3019-1, flange 82-2 (SAE A, 9 and 11 teeth) ISO 3019-1, flange 101-2 (SAE B, 13 teeth) ISO 3019-1, flange 101-2 (SAE B-B, 15 teeth) ISO 3019-1, flange 127-4 (SAE C, 14 teeth) Suction filtration X Integral full charge flow filtration Mounting G ISO 3019-1, flange 152-4 (SAE D) X Twin port, ISO 6162 Split flange ports Remote or external charge supply for full charge flow filtration X Auxiliary mounting pad ISO 3019-1, flange 152-4 (SAE D, 13 teeth) Suction filtration X Integral full charge flow filtration X Remote or external charge supply for full charge flow filtration Input shaft G3 ISO 3019-1, outer dia 44 mm - 4 (SAE D, 13 teeth splined shaft 8 /16 pitch) G2 ISO 3019-1, outer dia 44 mm - 4 (SAE D, 27 teeth splined shaft 16 /32 pitch) F3 Conical keyed shaft end similar to ISO 3019-1 code 44-3, taper 1:8 (key not supplied with pump) X 8 11063347 Rev CB Jan 2013

General Technical Specifications Model Code (continued) A B D F E G H J K M N S T V W X Y H1 P N N N N N N N N K NN H2 H1 H3 H5 H6 H4 Auxiliary mounting pad (align with option G: Endcap selection) None ISO 3019-1, flange 82-2, outer dia 16 mm - 4 (SAE A, 9 teeth 16 /32 coupling) ISO 3019-1, flange 82-2, outer dia 19 mm - 4 (SAE A, 11 teeth 16 /32 coupling) ISO 3019-1, flange 101-2, outer dia 22 mm - 4 (SAE B, 13 teeth 16 /32 coupling) ISO 3019-1, flange 101-2, outer dia 25 mm - 4 (SAE B-B, 15 teeth 16 /32 coupling) ISO 3019-1, flange 127-4, outer dia 32 mm - 4 (SAE C, 14 teeth 12 /24 coupling) ISO 3019-1, flange 152-4, outer dia 44 mm - 4 (SAE D, 13 teeth 8 /16 coupling) M Overpressure protection type and setting side A ** N Overpressure protection type and setting side B ** ** Pressure protection type must be the same for side A and B S T V W X Y L High pressure relief valve + pressure limiters with bypass K High pressure relief valve only with bypass (no pressure limiters) L20 K20 200 bar [2900 psi] L23 K23 230 bar [3336 psi] L25 K25 250 bar [3630 psi] L28 K28 280 bar [4061 psi] L30 K30 300 bar [4350 psi] L33 K33 330 bar [4786 psi] L35 K35 350 bar [5080 psi] Use the selection for ports A and B L38 K38 380 bar [5510 psi] L40 K40 400 bar [5800 psi] L42 K42 420 bar [6090 psi] L43 430 bar [6237 psi] L44 440 bar [6382 psi] L45 K45 450 bar [6960 psi] Contact factory for pressures not shown or for applied pressure above maximum working pressure (see system pressure page 5) Charge pump A 26 cm³/rev [1.57 in³/rev] L 34 cm³/rev [2.07 in³/rev] N No charge pump, external charge supply, (align with Option T: Filtration Options, option E) Filtration options (align with option G: Endcap selection) L Suction filtration (see Basic drawings) M Integral full charge flow filtration with bypass and bypass sensor, long filter, order number 11004919 P Remote full charge flow filtration (see endcap drawings) E External charge flow filtration (see endcap drawings), (align with option S: Charge pump, option N) Charge pressure relief setting (contact factory for pressure not shown) 20 20 bar [290 psi] 24 24 bar [348 psi] 30 30 bar [435 psi] Special hardware features PN None Paint and nametag NNN Black paint and Sauer-Danfoss nametag Special settings NNN None 11063347 Rev CB Jan 2013 9

General Technical Specifications Electrical Displacement Control (EDC) Options A2 (12 V)/A3 (24 V) EDC Principle The Electrical Displacement Control (EDC) consists of a pair of proportional solenoids on each side of a threeposition, four-way porting spool. The proportional solenoid applies a force input to the spool, which ports hydraulic pressure to either side of a double acting servo piston. Differential pressure across the servo piston rotates the swashplate, changing the pump s displacement from full displacement in one direction to full displacement in the opposite direction. Under some circumstances, such as contamination, the control spool could stick and cause the pump to stay at some displacement. P003 191 A serviceable 125 μm screen is located in the supply line immediately before the control porting spool. Pump displacement vs. control current EDC-Schematic diagram C1 M14 C2 100 % F00B F00A Feedback from Swash plate T P P003 478E Displacement -b -a "0" a Current ma b Control signal requirements Control current Voltage a* ma b ma Pin connections 12 V 640 1640 any order 24 V 330 820 * Factory test current, for vehicle movement or application actuation expect higher or lower value. T000133E Connector 100 % P003 479E 1 2 P003 480 Description Quantity Ordering number Mating connector 1 Deutsch DT06-2S Wedge lock 1 Deutsch W2S Socket contact (16 and 18 AWG) 2 Deutsch 0462-201-16141 Sauer-Danfoss mating connector kit 1 K29657 T000 134E 10 11063347 Rev CB Jan 2013

General Technical Specifications Electrical Displacement Control (EDC) Options A2 (12 V)/A3 (24 V) (continued) Solenoid data Voltage 12V 24V Maximum current 1800 ma 920 ma Coil resistance @ 20 C [70 F] 3.66 Ω 14.20 Ω Coil resistance @ 80 C [176 F] 4.52 Ω 17.52 Ω PWM Range 70-200 Hz PWM Frequency (preferred)* 100 Hz Inductance 33 mh 140 mh IP Rating (IEC 60 529) + DIN 40 050, part 9 IP 67 IP Rating (IEC 60 529) + DIN 40 050, part 9 with mating connector IP 69K * PWM signal required for optimum control performance. T000 135E Flow table Shaft rotation CW CCW Coil energized* C2 C1 C2 C1 Port A in out out in Port B out in in out Servo port pressurized M5 M4 M5 M4 * For coil location see installation drawings. T000 136E Control response H1 controls are available with optional control passage orifices to assist in matching the rate of swashplate response to the application requirements (e.g. in the event of electrical failure). Software ramp or rate limiting should be used to control vehicle response in normal operation. The time required for the pump output flow to change from zero to full flow (acceleration) or full flow to zero (deceleration) is a net function of spool porting, orifices, and charge pressure. A swashplate response table is available for each frame indicating available swashplate response times. Testing should be conducted to verify the proper software and orifice selection for the desired response. H1 pumps are limited in mechanical orificing combinations. Software is envisioned as the means to control the swashplate response in normal operating conditions. Mechanical servo orifices are to be used only for fail-safe return to neutral in the event of an electrical failure. Typical response times shown below at the following conditions: p = 250 bar [3626 psi] Viscosity and temperature = 30 mm 2 /s (50 C) [141 SUS (122 F)] Charge pressure = 20 bar [290 psi] Speed = 1800 min -1 (rpm) Response times Stroking direction 0.8 mm [0.03 in] Orifice 1.3 mm [0.05 in] Orifice No orifice Neutral to full flow 5.8 s 2.1 s 1.3 s Full flow to neutral 2.4 s 1.6 s 1.2 s T301 024 11063347 Rev CB Jan 2013 11

General Technical Specifications Manual Over Ride (MOR) All controls are available with a Manual Over Ride (MOR) either standard or as an option for temporary actuation of the control to aid in diagnostics. Forward-Neutral-Reverse (FNR) and Non Feedback Proportional Electric (NFPE) controls are always supplied with MOR functionality. Unintended MOR operation will cause the pump to go into stroke. The vehicle or device must always be in a safe condition (i.e. vehicle lifted off the ground) when using the MOR function. The MOR plunger has a 4 mm diameter and must be manually depressed to be engaged. Depressing the plunger mechanically moves the control spool which allows the pump to go on stroke. The MOR should be engaged anticipating a full stroke response from the pump. Warning An o-ring seal is used to seal the MOR plunger where initial actuation of the function will require a force of 45 N to engage the plunger. Additional actuations typically require less force to engage the MOR plunger. Proportional control of the pump using the MOR should not be expected. Refer to control flowtable for the relationship of solenoid to direction of flow. P003 204 MOR-Schematic diagram (EDC shown) M14 C1 C2 F00B Feedback from Swash plate F00A T P P003 205E 12 11063347 Rev CB Jan 2013

General Technical Specifications Displacement Limiter H1 pumps are designed with optional mechanical displacement (stroke) limiters factory set to max. displacement. The maximum displacement of the pump can be set independently for forward and reverse using the two adjustment screws to mechanically limit the travel of the servo piston down to 50 % displacement. Adjustment procedures are found in the H1 pumps Service Manual. Adjustments under operating conditions may cause leakage. The adjustment screw can be completely removed from the threaded bore if backed out to far. Displacement limiter P003 266 Displacement change (approximately) Size 1 Turn of displacement limiter screw 147 12.4 cm 3 [0.76 in 3 ] 165 13.9 cm 3 [0.85 in 3 ] Internal wrench size External wrench size Torque for external hex seal lock nut 6 mm 22 mm 80 Nm [708 lbf in] T301 025E For more information refer to H1 pumps Service Manual 520L0848, section Displacement Limiter Adjustment. 11063347 Rev CB Jan 2013 13

Dimensions Input Shafts Option G3, ISO 3019-1, outer dia 44 mm-4 (SAE D, 13 teeth) 8.0 [0.316] Coupling must not protrude beyond this Point Mounting flange surface flange 127-4 per ISO 3019-1 to be paint free 67.0 [2.638] 39.5 [1.555] Spline Data Number of Teeth : 13 Pitch Fraction : 8/16 Pressure Angle : 30 Pitch- : 41.275 [1.625] Typ of Fit : Fillet Root Side Fit Per : Ansi B92.1-1996 Class 5 Shaft to be paint free 36.4 ± 0.25 [1.433 ± 0.010] 44.4 ± 0.09 [1.746 ± 0.004] Specifications P003 272E Option Spline Min active spline length 2 Torque rating 1 Rated torque Maximum torque mm [in] Nm [lbf in] Nm [lbf in] G3 13 teeth, 8/16 pitch 39.5 [1.555] 1442 [12 800] 2206 [19 500] 1) For definitions of maximum and rated torque values, refer to: Basic Information Manual 11062168, section Shaft Torque Ratings and Spline Lubrication. 2) Minimum active spline length for the specified torque ratings. T000 200E Option G2, ISO 3019-1, outer dia 44 mm-4 (SAE D, 27 teeth) 8.05 [0.317] Coupling must not protrude beyond this point Mounting flange surface flange 127-4 per ISO 3019-1 to be paint free 67.0 [2.638] 42.0 [1.654] Spline Data Number of Teeth : 27 Pitch Fraction : 16/32 Pressure Angle : 30 Pitch- : 42.863 [1.688] Typ of Fit : Fillet Root Side Fit Per : Ansi B92.1-1996 Class 5 Shaft to be paint free 39.5 ± 1.0 [1.555 ± 0.039] 44.36 ± 0.09 [1.746 ± 0.004] Specifications P003 271E Option Spline Min active spline length 2 Torque rating 1 Rated torque Maximum torque mm [in] Nm [lbf in] Nm [lbf in] G2 27 teeth, 16/32 pitch 42.0 [1.654] 1615 [14 300] 3000 [26 550] 1) For definitions of maximum and rated torque values, refer to: Basic Information Manual 11062168, section Shaft Torque Ratings and Spline Lubrication. 2) Minimum active spline length for the specified torque ratings. T000 201E 14 11063347 Rev CB Jan 2013

Dimensions Input Shafts (continued) Option F3, ISO 3019-1, Code 44-3, Diameter 44.5 taper 1:8, without key and no through-hole in the end of the shaft Mounting flange surface Flange 127-4 per ISO 3019-1 to be paint free Conical keyed shaft end similar to ISO 3019-1 code 38-3 Suitable key 7 /16 x 7 /16 x 1 3 /4 ANSI B17.1 mm [in] 125 ±0.5 : 1000 1 1 /4-12 44.45 [1.750] Shafts to be paint free Specifications 8.025 ±0.8 [0.361 ±0.31] (54.0) [2.126] 93.7 ±1.0 [3.689 ±0.039] 39.7 ±1.0 [1.563 ±0.039] Coupling must not overlap till this point P301 212 Torque rating 1) Option Tapered shaft Rated torque* Maximum torque Nm [lfb in] Nm [lfb in] F3 44-3 taper without key 2) 1766 [15 630] 2354 [20 830] 1) For definitions of maximum and rated torque values, refer to: Basic Information Manual 11062168, section Shaft Torque Ratings and Spline Lubrication. 2) Mating part must maintain a minimum gap width of 1.0 mm with the shaft shoulder after installation of the part. Transmittable torque will be reduced if the minimum gap requirement is not met. * Rated torque includes just the capability of the press-fit in accordance with an assumed fastener grade 5. T000 202E Tapered shaft customer acknowledgement The Sauer-Danfoss H1 tapered shaft has been designed using the industry standard ISO 3019-1, minus the through-hole in the end of the shaft. Sauer-Danfoss recommends a self-locking nut instead of a castle nut and pin. The nut and mating square-cut key are customer supplied. The specified torque rating of the tapered shaft documented above is based on the cross-sectional diameter of the shaft, through the keyway, and assumes the proper clamp and fit between shaft and coupling. Sauer-Danfoss guarantees the design and manufactured quality of the tapered shaft. The customer is responsible for the design and manufactured quality of the mating female coupling and key and applied torque on the nut. Sauer-Danfoss has made provisions for the key in accordance to the ISO specification with the understanding that the key is solely to assist in the installation of the mating coupling. CCaution Torque must be transmitted by the taper fit between the shaft and it s mating coupling, not the key. Torque or loading inadvertently transmitted by the customer supplied key may lead to premature shaft failure. 11063347 Rev CB Jan 2013 15

] Dimensions Auxiliary Mounting Pads Option H2, ISO 3019-1, flange 82-2 (SAE A, 9 teeth) Mounting flange surface Flange 82-2 per iso 3019-1 to be paint free 346.0 ± 2 [13.621 ± 0.079] 330.8 ± 2 [13.025 ± 0.079] 2x 106.4 ± 0.35 [4.189 ± 0.014] 4x 53.2 ± 0.175 [2.094 ± 0.007] ] 82.601 + 0 0.076 [3.252 + 0.003 0 88.621 + 0 0.13 [3.489 + 0.05 0 R 0.8 max. [0.031] 15.3 [0.602] Thread Depth 4x : M10 x 1.5-6H THD : 16 [0.63] min. O-ring seal required ref 82.22 [3.237] I.D. x 2.62 [0.103] cross section 1.96 [0.077] 8.1 ± 0.25 [0.319 ± 0.010] Spline data Number of teeth : 9 Pitch fraction : 16/32 Pressure angle : 30 Pitch-Ø : 14.288 [0.5625] Typ of fit : Fillet root side per : Ansi B92.1-1996 class 6 P003 273E Specifications Option Spline Torque rating 1 maximum torque Nm [lbf in] H2 9 teeth, 16/32 pitch 162 [1430] 1) For definitions of maximum torque values, refer to: Basic Information Manual 11062168, section Shaft Torque Ratings and Spline Lubrication. T000 150E C Caution Standard pad cover is installed only to retain coupling during shipping. Do not operate pump without an auxiliary pump or running cover installed. 16 11063347 Rev CB Jan 2013

Dimensions Auxiliary Mounting Pads (continued) Option H1, ISO 3019-1, flange 82-2 (SAE A, 11 teeth) 330.8 ± 2 [13.025 ± 0.079] 346.0 ± 2.0 [13.621 ± 0.079] 2x 106.4 ± 0.35 [4.189 ± 0.014] 4x 53.2 ± 0.175 [2.094 ± 0.007] 15.3 ± 1 [0.602 ± 0.039] 88.621 + 0 0.13 ] 82.601 + 0 0.076 [3.252 + 0.003 0 ] Mounting flange surface Flange 82-2 per iso 3019-1 to be paint free [3.489 + 0.05 0 R 0.8 max. [0.031] Thread : M10 x 1.5-6H THD Depth : 16.0 [0.63] min. 4x O-ring seal required ref 82.22 [3.237] I.D. x 2.62 [0.103] cross section 1.96 [0.077] 8.1 ± 0.25 [0.319 ± 0.010] Spline data Number of teeth : 11 Pitch fraction : 16/32 Pressure angle : 30 Pitch- : 17.463 [0.688] Typ of fit : Fillet root side per : Ansi B92.1-1996 class 6 P003 360E Specifications Option Spline Torque rating 1 maximum torque Nm [lbf in] H1 11 teeth, 16/32 pitch 296 [2620] 1) For definitions of maximum torque values, refer to: Basic Information Manual 11062168, section Shaft Torque Ratings and Spline Lubrication. T000 151E C Caution Standard pad cover is installed only to retain coupling during shipping. Do not operate pump without an auxiliary pump or running cover installed. 11063347 Rev CB Jan 2013 17

] ] Dimensions Auxiliary Mounting Pads (continued) Option H3, ISO 3019-1, flange 101-2 (SAE B, 13 teeth) Mounting flange surface Flange 101-2 per iso 3019-1 To be paint free 346.5 ± 2 [13.642 ± 0.079] 330.8 ± 2 [13.025 ± 0.079] 2x 146.0 ± 0.35 [5.748 ± 0.014] 4x 73.0 ± 0.175 [2.874 ± 0.007] 101.651 + 0 0.076 [4.002 + 0.003 0 20.3 [0.799] 107.823 + 0 0.13 [4.245 + 0.05 0 R 0.8 max. [0.031] Thread : M12 x 1.75 Depth : 25.0 [0.984] min. 4x O-ring seal required ref 94.92 [3.737] I.D. x 2.62 [0.103] cross section 1.96 [0.077] 11.4 ± 0.25 [0.449 ± 0.010] Spline data Number of teeth : 13 Pitch fraction : 16/32 Pressure angle : 30 Pitch- : 20.638 [0.813] Typ of fit : Fillet root side per : Ansi B92.1-1996 class 6 P003 274E Specifications Option Spline Torque rating 1 maximum torque Nm [lbf in] H3 13 teeth, 16/32 pitch 395 [3500] 1) For definitions of maximum torque values, refer to: Basic Information Manual 11062168, section Shaft Torque Ratings and Spline Lubrication. T000 152E C Caution Standard pad cover is installed only to retain coupling during shipping. Do not operate pump without an auxiliary pump or running cover installed. 18 11063347 Rev CB Jan 2013

] ] Dimensions Auxiliary Mounting Pads (continued) Option H5, ISO 3019-1, flange 101-2 (SAE B-B, 15 teeth) Mounting flange surface Flange 101-2 per iso 3019-1 to be paint free 346.5 ± 2 [13.642 ± 0.079] 330.8 ± 2 [13.025 ± 0.079] 2x 146.0 ± 0.35 [5.748 ± 0.014] 4x 73.0 ± 0.175 [2.874 ± 0.007] 101.651 + 0 0.076 [4.002 + 0.003 0 21.3 [0.839] 107.823 + 0 0.13 [4.245 + 0 0.005 R 0.8 max. [0.031] Thread : M12 x 1.75 Depth : 25.0 [0.984] min. 4x O-ring seal required ref 94.92 [3.737] I.D. 1.96 x 2.62 [0.103] cross section[0.077] 11.4 ± 0.25 [0.449 ± 0.010] Spline data Number of teeth : 15 Pitch fraction : 16/32 Pressure angle : 30 Pitch- : 23.813 [0.938] Typ of fit : Fillet root side per : Ansi B92.1-1996 class 6 P003 199E Specifications Option Spline Torque rating 1 maximum torque Nm [lbf in] H5 15 teeth, 16/32 pitch 693 [6130] 1) For definitions of maximum torque values, refer to: Basic Information Manual 11062168, section Shaft Torque Ratings and Spline Lubrication. T000 153E C Caution Standard pad cover is installed only to retain coupling during shipping. Do not operate pump without an auxiliary pump or running cover installed. 11063347 Rev CB Jan 2013 19

] Dimensions Auxiliary Mounting Pads (continued) Option H6, ISO 3019-1, flange 127-4 (SAE C, 14 teeth) 349.5 ± 2 [13.762 ± 0.079] 333.8 ± 2 [13.142 ± 0.079] 181.0 ± 0.35 [7.126 ± 0.014] 2x 90.5 ± 0.175 [3.563 ± 0.007] 127.05 + 0 0.076 [5.002 + 0 0.003 ] Mounting flange surface Flange 127-4 per iso 3019-1 to be paint free 23.3 ± 1 [0.917 ± 0.039] 134.06 + 0.13 0 [5.278 + 0.005 0 R 0.8 max. [0.031] Thread : M16 x 2-6H THD Depth : 28.5 [1.122] min. 2x Thread : M12 x 1.75 Depth : 28.5 [1.122] min. 4x 4x 57.25 ± 0.175 [2.254 ± 0.007] O-ring seal required ref 120.32 [4.737] I.D. x 2.62 [0.103] cross section 1.96 [0.077] 2x 114.5 ± 0.35 [4.508 ± 0.014] 15.0 ± 0.25 [0.591 ± 0.010] Spline data Number of teeth : 14 Pitch fraction : 12/24 Pressure angle : 30 Pitch- : 29.633 [1.167] Typ of fit : Fillet root side per : Ansi B92.1-1996 class 6 P003 275E Specifications Option Spline Torque rating 1 maximum torque Nm [lbf in] H6 14 teeth, 12/24 pitch 816 [7220] 1) For definitions of maximum torque values, refer to: Basic Information Manual 11062168, section Shaft Torque Ratings and Spline Lubrication. T000 154E C Caution Standard pad cover is installed only to retain coupling during shipping. Do not operate pump without an auxiliary pump or running cover installed. 20 11063347 Rev CB Jan 2013

Dimensions Auxiliary Mounting Pads (continued) Option H5, ISO 3019-1, flange 152-4 (SAE D, 13 teeth) 4x 161.6 ± 0.35 [6.362 ± 0.014] 8x 80.8 ± 0.175 [3.181 ± 0.007] 353.9 ± 2 [13.934 ± 0.079] 333.2 ± 2 [13.119 ± 0.079] 27.48 [1.082] 159.0 + 0 0.13 [6.260 + 0.005 0 152.45 + 0 0.076 [6.002 + 0 0.003 ] ] Mounting flange surface Flange 152-4 per ISO 3019-1 to be paint free Thread : M20 x 2.5-6H THD Depth : 30.0 [1.181] min. 4x O-ring seal required ref 150.0 [5.906] I.D. x 3.0 [0.118] cross section 2.5 [0.098] 14.0 [0.551] Spline data Number of teeth : 13 Pitch fraction : 8/16 Pressure angle : 30 Pitch- : 41.275 [1.625] Typ of fit : Fillet root side per : Ansi B92.1-1996 class 6 P003 276E Specifications Option Spline Torque rating 1 maximum torque Nm [lbf in] H4 13 teeth, 8/16 pitch 2206 [19 500] 1) For definitions of maximum torque values, refer to: Basic Information Manual 11062168, section Shaft Torque Ratings and Spline Lubrication. T000 203E C Caution Standard pad cover is installed only to retain coupling during shipping. Do not operate pump without an auxiliary pump or running cover installed. 11063347 Rev CB Jan 2013 21

Charge Pump Charge Pump Charge pump sizing/selection In most applications a general guideline is that the charge pump displacement should be at least 10 % of the total displacement of all components in the system. Unusual application conditions may require a more detailed review of charge flow requirements. Please refer to BLN-9885, Selection of Drive line Components, for a detailed procedure. System features and conditions which may invalidate the 10 % guideline include (but are not limited to): Continuous operation at low input speeds (< 1500 min -1 (rpm)) High shock loading and/or long loop lines High flushing flow requirements Multiple Low Speed High Torque motors High input shaft speeds Contact your Sauer-Danfoss representative for application assistance if your application includes any of these conditions. Charge pump flow and power curves Charge pressure: 20 bar [290 psi] Viscosity and temperature: 11 mm 2 /s [63 SUS] 80 C [180 F] Charge pump flow Charge pump power requirements 27 100 24 90 14.0 13.0 10 21 80 12.0 9 US gal/min 18 15 12 9 6 3 1 l/min 70 60 50 40 30 20 10 0 34 cm 3 [2.07 in 3 /rev] 0 500 1500 1000 2000 Speed min -1 (rpm) 26 cm 3 [1.59 in 3 /rev] 2500 3500 3000 P003 335E 11.0 10.0 9.0 8.0 HP 7.0 6.0 5.0 4.0 3.0 2.0 1.0 Kw 8 7 6 5 4 3 2 1 0 34 cm 3 [2.07 in 3 /rev] 0 500 1500 1000 2000 Speed min -1 (rpm) 26 cm 3 [1.59 in 3 /rev] 2500 3500 3000 P003 337E 22 11063347 Rev CB Jan 2013

Notes Notes 11063347 Rev CB Jan 2013 23

Installation Drawings Port Description System port B 31.5 450 bar Split flange boss per ISO 6162 M12 x 1.75 20 min full thread depth Servo gauge port M4 Port ISO 11926-1 7 /16-20 24.5 max clearance dia for fitting Connector : Deutsch DT04-2P to be paint free Case pressure port Port ISO 11926-1 1 1 /16-12 41 max clearance dia for fitting CCW Rotation CW Rotation System port A 31.5 450 bar Split flange boss per ISO 6162 M12 x 1.75 20 min full thread depth Case drain port L4 Port ISO 11926-1 1 5 /16-12 63 max clearance dia for fitting Charge inlet port S Port ISO 11926-1 1 5 /8-12 69 max clearance dia for fitting System A gauge port MA Port ISO 11926-1 9 /16-18 28 max clearance dia for fitting P003 277E Port description Port Description Sizes A System port A 31.5 B System port B 31.5 E Charge filtration port, from filter 1 1 /16-12 F Charge filtration port, to filter 1 1 /16-12 L2 Case drain port 1 5 /16-12 L4 Case drain port 1 5 /16-12 MA System A gage port 9 /16-18 MB System B gage port 9 /16-18 M3 Charge gage port, after filtering 9 /16-18 M4 Servo gage port 7 /16-20 M5 Servo gage port 7 /16-20 M14 Case gage port 7 /16-20 S Charge inlet port 1 5 /8-12 T301 028E Please contact Sauer-Danfoss for specific installation drawings 24 11063347 Rev CB Jan 2013

Installation Drawings Port Description (continued) Case gauge port M14 Port ISO 11926-1 - 7 /16-20 21 max. clearance dia for fitting (EDC, FNR, NFPE) System B gauge port MB Port ISO 11926-1 9 /16-18 28 max clearance dia for fitting Charge pressure construction Port ISO 11926-1 - 5 /16-24 Charge filtration port F Port ISO 11926-1 1 1 /16-12 48 max clearance dia for fitting to filter Connector : Deutsch DT04-2P to bee paint free Case pressure port Port ISO 11926-1 1 1 /16-12 41 max clearance dia for fitting Servo gauge port M5 Port ISO 11926-1 7 /16-20 24.5 max clearance dia for fitting Charge filtration port E Port ISO 11926-1 1 1 /16-12 48 max clearance dia for fitting from filter Charge pressure construction Port ISO 11926-1 - 5 /16-24 Case drain port L2 Port ISO 11926-1 5 /16-12 63 max clearance dia for fitting Charge gauge port M3 Port ISO 11926-1 9 /16-18 28 max clearance dia for fitting after filtering P003 278E Please contact Sauer-Danfoss for specific installation drawings 11063347 Rev CB Jan 2013 25

Installation Drawings Dimensions Servo Gauge Port M4 Port ISO 11926-1 7 /16-20 24.5 max clearance dia for fitting System Port B 31.5 450 bar Split Flange Boss per ISO 6162 M12 x 1.75 20 min. Full Thread Depth Charge Inlet Port S Port ISO 11926-1 1 5 /8-12 69 max clearance dia for fitting 333.0 ± 0.4 [13.112 ± 0.079] 255.7 + 0.5 0.6 [10.068 + 0.024 0.02 ] 179.9 ± 1.0 [7.08 ± 0.039] Connector : Deutsch DT04-2P to be paint free 150.0 ± 1.0 [5.91 ± 0.039] B Mounting Flange surface flange 127-4 per ISO 3019-1 to be paint free 51.9 ± 1.0 [2.04 ± 0.039] Case Pressure Port Port ISO 11926-1 1 1 /16-12 41 max clearance dia for fitting 12.45 ± 0.25 [0.49 ± 0.01] 1.5 ± 0.5 x 45 ±5 [0.059 ± 0.028 x 45 ] Z 182.4 ± 1.0 [7.18 ± 0.039] 155.5 ± 1.0 [6.12 ± 0.039] 81.5 ± 1.0 [3.21 ± 0.039] 135.0 ± 1.0 [5.31 ± 0.039] 80.0 + 0.1 0.2 [3.15 + 0.008 0.004 ] 80.0 + 0.1 0.2 [3.15 + 0.008 0.004 ] (4x) 31.8 ± 0.25 [1.25 ± 0.01] C C D B R 0.8 max. [0.031] 42.0 ± 1.0 [1.65 ± 0.039] 152.4 + 0.05 0 [6.0 + 0 0.002 ] (8x) 15.9 ± 0.25 [0.63 ± 0.01] (8x) 33.3 ± 0.25 [1.31 ± 0.01] D 22.9 ± 0.2 [0.90 ± 0.008] Case Drain Port L4 Port ISO 11926-1 1 5 /16-12 63 max clearance dia for fitting 8.05 ± 0.8 [0.317 ± 0.031] 67.0 ± 1.0 [2.64 ± 0.039] System Port A Ø31.5 450 bar Split Flange Boss per ISO 6162 M12 x 1.75 20 min. Full Thread Depth (4x) 66.6 ± 0.25 [2.62 ± 0.01] 169.9 ± 1.0 [6.69 ± 0.039] B-B (2x) C-C D-D (2x) 63.5 ± 0.2 [2.5 ± 0.01] 115.4 ± 0.2 [4.54 ± 0.01] 111.0 ± 0.2 [4.37 ± 0.01] Shaft LC Shaft LC Shaft LC P003 279E Please contact Sauer-Danfoss for specific installation drawings 26 11063347 Rev CB Jan 2013

Installation Drawings Dimensions (continued) 51.9 ± 1.0 [2.04 ± 0.039] Case pressure port Port ISO 11926-1 1 1 /16-12 41 max clearance dia for fitting Y 179.9 ±1.0 [7.08 ±0.039] 150.0 ±1.0 Servo gauge port M5 [5.91 ±0.039] Port ISO 11926-1 7 /16-20 152.6 ±1.0 Connector: 24.5 max clearance dia for fitting [6.01 ±0.039] Deutsch DT04-2P Charge pressure constr. port to be paint free Port ISO 11926-1 5 /16-24 1.1 [0.043] Z 131.9 ±1.0 [5.19 ±0.039] 24.3 [0.96] 182.4 ±1.0 [7.18 ±0.039] 155.5 ±1.0 [6.12 ±0.039] 135.0 ± 1.0 [5.32 ±0.039] 208.3 ±1.0 [8.20 ±0.039] X 81.5 ± 1.0 [3.21 ± 0.039] 112.0 ±1.0 [4.41 ±0.039] 209 max [8.228] 128.4 ±2.0 [5.055 ±0.079] 64.2 ±1.0 [2.528 ±0.039] Approximate center of gravity 165.0 [6.496] 87.9 ±1.0 [3.46 ±0.039] 169.9 ± 1.0 [6.689 ± 0.039] Case gauge port M14 Port ISO 11926-1 7 /16-20 21 max clearance dia for fitting W 270.7 ±1.0 [10.66 ±0.039] 270.72 ±1.0 [10.658 ±0.039] 273.42 ±1.0 [10.765 ±0.039] E F Charge gauge port M3 Port ISO 11926-1 9 /16-18 28 max clearance dia for fitting after filtering Case drain port L2 Port ISO 11926-1 1 5 /16-12 63 max clearance dia for fitting Y Charge pressure construction port Port ISO 11926-1 5 /16-24 System B gauge port MB Port ISO 11926-1 9 /16-18 28 max clearance dia for fitting 8.0 ±1.0 [0.315 ±0.039] F 92.0 ±1.0 [3.62 ±0.039] 69.0 ±1.0 [2.717 ±0.039] E Charge filtration port F Port ISO 11926-1 1 1 /16-12 48 max clearance dia for fitting to filter Charge filtration port E Port ISO 11926-1 1 1 /16-12 48 max clearance dia for fitting from filter F-F 11 E-E 11 Approximate center of gravity Charge filtration port F Port ISO 11926-1 1 1 /16-12 48 max clearance dia for fitting to filter 113.3 ± 0.1 [4.461 ± 0.039] Charge filtration port E Port ISO 11926-1 1 1 /16-12 48 max clearance dia for fitting from filter 113.6 ± 0.1 [4.472 ± 0.039] P003 280E Please contact Sauer-Danfoss for specific installation drawings 11063347 Rev CB Jan 2013 27

Installation Drawings Dimensions (continued) System A gauge port MA Port ISO 11926-1 9 /16-18 28 max clearance dia for fitting W 255.7 [10.07] X 92.0 ± 1.0 [3.62 ± 0.039] CCW Rotation CW Rotation (4x) 80.8 ± 0.25 [3.18 ± 0.01] (4x) 40 ± 0.25 [1.575 ± 0.01] other side screw head space (4x) 80.8 ± 0.25 [3.18 ± 0.01] (4x) 20.6 + 0.25 0.13 [0.811 + 0.01 0.005 ] P003 281E Please contact Sauer-Danfoss for specific installation drawings 28 11063347 Rev CB Jan 2013

Installation Drawings Dimensions (continued) Controls Electric Displacement Control (EDC), option A2 (12 V) / A3 (24 V) Connector : Deutsch DT04-2P to be paint free Case gauge port M14 Port ISO 11926-1 7 /16-20 21 max clearance dia for fitting 209.0 max [8.228] 128.4 ± 2.0 [5.055 ± 0.079] 64.2 ± 1.0 [2.528 ± 0.039] 87.9 ± 1.0 [3.46 ± 0.039] Shaft LC Mounting flange 121.9 ± 1.0 [4.8 ± 0.039] 208.3 max [8.2] Shaft LC 2x 182.4 ± 1.0 [7.18 ± 0.04] Connector : Deutsch DT04-2P to be paint free 2x 150.0 ± 1.0 [5.91 ± 0.04] P003 340E Electric Displacement Control (EDC) with manual override, option A4 (12 V) / A5 (24 V) Connector : Deutsch DT04-2P to be paint free Case gauge port M14 Port ISO 11926-1 7 /16-20 21 max clearance dia for fitting 209.0 max [8.228] 128.4 ± 2.0 [5.055 ± 0.079] 64.2 ± 1.0 [2.528 ± 0.039] 87.9 ± 1.0 [3.46 ± 0.039] 121.9 ± 1.0 [4.8 ± 0.039] Shaft LC Mounting flange 208.3 max [8.2] 2x 182.4 ± 1.0 [7.18 ± 0.04] Shaft LC Connector : Deutsch DT04-2P to be paint free 2x 150.0 ± 1.0 [5.91 ± 0.04] Please contact Sauer-Danfoss for specific installation drawings P003 341E 11063347 Rev CB Jan 2013 29

Notes Notes 30 11063347 Rev CB Jan 2013

Installation Drawings Dimensions (continued) Displacement limiters Displacement limiter, option B 2 x Wrench size 6 (external hex) 153.7 ± 1.0 [6.051 ± 0.039] 176.5 ± 2.0 [6.949 ± 0.079] 176.5 ± 2.0 [6.949 ± 0.079] 2 x Wrench size 22 (external hex) 103.3 ± 1.0 [4.067 ± 0.039] P003 344E Please contact Sauer-Danfoss for specific installation drawings 11063347 Rev CB Jan 2013 31

Installation Drawings Dimensions (continued) Displacement limiters Suction filtration, option L 255.7 + 0.5 0.6 [10.068 + 0.024 ] 0.02 Charge pump inlet S Port ISO 11926-1 1 5 /8-12 C-C 115.8 ± 0.2 [4.56 ± 0.01] Shaft LC P003 202E Please contact Sauer-Danfoss for specific installation drawings 32 11063347 Rev CB Jan 2013

Installation Drawings Dimensions (continued) Filtration Integral full flow charge pressure filtration with filter bypass sensor, option M 203.265 ± 1.0 [8.003 ± 0.039] 226.0 ± 2.0 [8.884 ± 0.079] 140.3 ± 2.0 [5.522 ± 0.079] Connector : Deutsch DTM04-2P to be paint free Charge gauge port M6 Port ISO 11926-1 9 /16-18 before filter 41.62 ± 2.0 [1.639 ± 0.079] 77.75 ± 1.0 [3.061 ± 0.039] 314.91 ± 1.0 [12.398 ± 0.039] 323.72 ± 1.0 [12.745 ± 0.039] 32.7 ± 1.0 [1.288 ± 0.039] P003 282E Please contact Sauer-Danfoss for specific installation drawings 11063347 Rev CB Jan 2013 33

Notes Notes 34 11063347 Rev CB Jan 2013

Notes Notes 11063347 Rev CB Jan 2013 35

Products we offer: Bent Axis Motors Closed Circuit Axial Piston Pumps and Motors Displays Electrohydraulic Power Steering Electrohydraulics Hydraulic Power Steering Integrated Systems Joysticks and Control Handles Microcontrollers and Software Open Circuit Axial Piston Pumps Orbital Motors PLUS+1 GUIDE Proportional Valves Sensors Steering Transit Mixer Drives Members of the Sauer-Danfoss Group: Sauer-Danfoss is a global manufacturer and supplier of highquality hydraulic and electronic components. We specialize in providing state-of-the-art technology and solutions that excel in the harsh operating conditions of the mobile off-highway market. Building on our extensive applications expertise, we work closely with our customers to ensure exceptional performance for a broad range of off-highway vehicles. We help OEMs around the world speed up system development, reduce costs and bring vehicles to market faster. Sauer-Danfoss Your Strongest Partner in Mobile Hydraulics. Go to www.sauer-danfoss.com for further product information. Wherever off-highway vehicles are at work, so is Sauer-Danfoss. We offer expert worldwide support for our customers, ensuring the best possible solutions for outstanding performance. And with an extensive network of Global Service Partners, we also provide comprehensive global service for all of our components. Please contact the Sauer-Danfoss representative nearest you. Local address: Comatrol www.comatrol.com Schwarzmüller-Inverter www.schwarzmueller-inverter.com Turolla www.turollaocg.com Valmova www.valmova.com Sauer-Danfoss (US) Company 2800 East 13th Street Ames, IA 50010, USA Phone: +1 515 239 6000 Fax: +1 515 239 6618 Sauer-Danfoss ApS DK-6430 Nordborg, Denmark Phone: +45 7488 4444 Fax: +45 7488 4400 Hydro-Gear www.hydro-gear.com Sauer-Danfoss-Daikin www.sauer-danfoss-daikin.com 11063347 Rev CB Jan 2013 Sauer-Danfoss GmbH & Co. OHG Postfach 2460, D-24531 Neumünster Krokamp 35, D-24539 Neumünster, Germany Phone: +49 4321 871 0 Fax: +49 4321 871 122 Sauer-Danfoss-Daikin LTD. Shin-Osaka TERASAKI 3rd Bldg. 6F 1-5-28 Nishimiyahara, Yodogawa-ku Osaka 532-0004, Japan Phone: +81 6 6395 6066 Fax: +81 6 6395 8585 www.sauer-danfoss.com