DATA SHEET Frame Output Poles Frequency Rated voltage Rated current L. R. Amperes LRC No load current Rated speed Slip Rated torque Locked rotor torque Breakdown torque Insulation class Service factor Moment of inertia (J) Design : 586/7TZ : 450 HP (330 kw) : 4 : 60 Hz : 460 V : 527 A : 4216 A : 8.0x(Code J) : 212 A : 1793 rpm : 0.39 % : 1300 ft.lb : 240 % : 280 % : F : 1.15 : A Locked rotor time Temperature rise Duty cycle Ambient temperature Altitude Protection degree Cooling method Mounting Rotation¹ Noise level² Starting method Approx. weight³ : 36s (cold) 20s (hot) : 80 K : Cont.(S1) : -20 C to +40 C : 1000 m.a.s.l. : IP55 : IC411 - TEFC : F-1 : Both (CW and CCW) : 78.0 db(a) : Direct On Line : 3967 lb Output 25% 50% 75% 100% Foundation loads Efficiency (%) 94.6 95.0 95.4 95.8 Max. traction : 5612 lb Power Factor 0.41 0.65 0.77 0.82 Max. compression : 9580 lb Drive end Non drive end Bearing type : NU-324 C3 6319 C3 Sealing : Taconite Labyrinth Taconite Labyrinth Lubrication interval : 3000 h 8000 h Lubricant amount : 72 g 45 g Lubricant type : Mobil Polyrex EM Notes This revision replaces and cancel the previous one, which must be eliminated. (1) Looking the motor from the shaft end. (2) Measured at 1m and with tolerance of +3dB(A). (3) Approximate weight subject to changes after manufacturing process. (4) At 100% of full load. These are average values based on tests with sinusoidal power supply, subject to the tolerances stipulated in NEMA MG-1. Date 10/04/2018 1 / 7
DATA SHEET Thermal protection ID Application Type Quantity Sensing Temperature 1 Winding Thermostat - 2 wires 1 x Phase 155 ºC Space heater information Voltage: 200-240 V Date 10/04/2018 2 / 7
TORQUE AND CURRENT VS SPEED CURVE Performance : 460 V 60 Hz 4P Rated current : 527 A Moment of inertia (J) LRC : 8.0 Duty cycle : Cont.(S1) Rated torque : 1300 ft.lb Insulation class : F Locked rotor torque : 240 % Service factor : 1.15 Breakdown torque : 280 % Temperature rise : 80 K Rated speed : 1793 rpm Design : A Locked rotor time : 36s (cold) 20s (hot) Date 10/04/2018 3 / 7
LOAD PERFORMANCE CURVE Performance : 460 V 60 Hz 4P Rated current : 527 A Moment of inertia (J) LRC : 8.0 Duty cycle : Cont.(S1) Rated torque : 1300 ft.lb Insulation class : F Locked rotor torque : 240 % Service factor : 1.15 Breakdown torque : 280 % Temperature rise : 80 K Rated speed : 1793 rpm Design : A Date 10/04/2018 4 / 7
THERMAL LIMIT CURVE Performance : 460 V 60 Hz 4P Rated current : 527 A Moment of inertia (J) LRC : 8.0 Duty cycle : Cont.(S1) Rated torque : 1300 ft.lb Insulation class : F Locked rotor torque : 240 % Service factor : 1.15 Breakdown torque : 280 % Temperature rise : 80 K Rated speed : 1793 rpm Design : A Heating constant Cooling constant Date 10/04/2018 5 / 7
THERMAL LIMIT CURVE Date 10/04/2018 6 / 7
VFD OPERATION CURVE Performance : 460 V 60 Hz 4P Rated current : 527 A Moment of inertia (J) LRC : 8.0 Duty cycle : Cont.(S1) Rated torque : 1300 ft.lb Insulation class : F Locked rotor torque : 240 % Service factor : 1.15 Breakdown torque : 280 % Temperature rise : 80 K Rated speed : 1793 rpm Design : A Date 10/04/2018 7 / 7