Small Limit Switch D4V

Similar documents
Enclosed Switch. Ordering Information. Economical, High Utility Enclosed Switch. Model Number Legend D4MC- List of Models

Model Number Structure

Safety Limit Switch

Limit Switch D4D- N. Small, Economical Switch Featuring a Positive Opening Mechanism and Conforming to the CE Mark

Pre-wired Models D4C- (1) (2) (3) (4)

Manual Reset Limit Switch

D4B-N. uce. Safety Limit Switch. Positive Action Limit Switches with Direct Drive Contacts for Critical Switching Applications

D4D-N. Safety Limit Switch. Small, Economical Switch Featuring a Positive Opening Mechanism and CE Marking. H Contacts opened by positive opening

Miniature Enclosed Limit Switch D4MC. Ordering Information. Economical, General-Purpose, Enclosed Switch. H High precision and long life (10,000,000

Safety Limit Switch

Ordering Information. Snap Action Switch D2F. Subminiature Snap Action Switch D2F- Model Number Legend. Snap Action Switch D2F 31

HL (AZH) LIMIT SWITCHES

Model Number Structure

(3) Terminals. 00: AC connector. Comparison of New and Old Molded Terminal Models. Model Location of lead outlet

D4DS. Compact Interlock Safety Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. Refer to Precautions on page 9.

VL (AZ8) Limit Switches

VL (AZ8) Limit Switches

Ratings 1 A at 125 VAC 1 A at 30 VDC LED indicator Without indicator With indicator Without indicator With indicator Actuator

2NC (slow-action) Direct. Model. opening

Ordering Information. General-purpose Basic Switch X. Direct Current Switch with Built-in Magnetic Blowout. Model Number Legend

Safety-door Switch. Ordering Information

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

Multiple Limit Switch

(3) Terminals. 00: AC connector. Comparison of New and Old Molded Terminal Models. Model Location of lead outlet

HL (AZH) Limit Switches

Compact plastic limit switches with positive opening mechanism

Multiple Plunger Limit Switch

TKR CORPORATION

Subminiature Basic Switch

DL (AZD1) Mini Limit Switches

Compact plastic limit switches with positive opening mechanism

VL (AZ8) Mini Limit Switches

D4BL. Protective Doors Are Locked Until Machines Completely Stop Operating. Guard Lock Safety-door Switch. Model Number Structure.

HL (AZH) Limit Switches

D4B- N. Safety Interlock Switches. Safety Limit Switch. Specifications. Standards and EC Directives. Certified Standard Ratings D4BN

Limit Switches with Positive Opening Mechanism

D2SW-AQ. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend

Robust General-Purpose Limit Switch WL

2NC (slow-action) Direct. Model. opening

Hinged Safety Door Switch

D4DS. Safety-Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. H Conforms to EN (TÜV) standards.

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

Life PERFORMANCE Catalog listing Standards Structure Electrical performance Mechanical performance Ambient operating conditions Recommende tightening

Miniature Limit Switches

D2SW-P. Sealed Subminiature Basic Switch. Ordering Information D2SW-P

A22NK. Key-type Selector Switches

LJASeries. Limit Switches with Positive Opening Mechanism

HL Economical, Miniature Limit Switch Boasting Rigid Construction. General-purpose Limit Switch. Specifications. Model Number Structure

High-force: 230 g. Projected 7.3 mm General-purpose: 160 g. High-force: 230 g. Flat 4.3 mm General-purpose: 200 g.

BZSeries. Basic Switches

D2HW. Sealed Ultra Subminiature Basic Switch. Ordering Information

BZSeries. Basic Switches

Basic Switches. BZ Series APPLICATIONS SELECTION GUIDE. High-quality switches with UL certification. *C-UL approval number: E96090.

OMRON Z LIMIT SWITCH

D4GS-N CSM_D4GS-N_DS_E_7_2

WL/WLM. Wide Range of Two-circuit Switches; Select One for the Operating Environment/Application

Operation Key D4BS - K Head Mounting Direction F: Four mounting directions possible (front-side mounting at shipping)

D2VW. Sealed Miniature Basic Switch Conforms to IP67 (Excluding the terminals on terminal models) Model Number Legend. Sealed Miniature Basic Switch

D4DL. Guard Lock Safety-door Switch. Model Number Structure

SL (AZ3) Micro Limit Switches

Cable length. 3: 3 m. 4: Adjustable mounting (vertical) 4: 3NC (slow action) 5: 5 m. (Slow-action) Horizontal 1 m D4GS-N1R D4GS-N2R D4GS-N3R D4GS-N4R

WL-N/WLM-N. Two-circuit Limit Switch/Long-life Two-circuit Limit Switch

Safety-door Switch D4NS. Model Number Structure. Model Number Legend

Safety Switches & Operator Controls

Features. Emergency Stop Switch A22E. Install in 22-dia. or 25-dia. Panel Cutout. Safety Lock Mechanism to Prevent Misuse.

Best-selling Basic Switch Boasting High Precision and Wide Variety

SL1Series. Compact Horizontal Limit Switches

D4BS CSM_D4BS_DS_E_8_4

Model Number Structure

PCB Relay. Contact form Terminals Coil terminals Rated voltage Model SPST-NO #250 tab terminals PCB terminals 5, 12, 24 VDC G4A-1A

D2SW. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend

D4DL. Guard Lock Safety-door Switch. Ordering Information. Model Number Legend Switches D4DL- -

Emergency Stop Pushbutton Switches (22-dia. or 25-dia.) A22E/A22NE-P

D2VW. Sealed Miniature Basic Switch. Ordering Information Model Number Legend D2VW- -

D2HW. Sealed Ultra Subminiature Basic Switch. Ordering Information

G7S. Ordering Information. Plug-In Safety Relay. Safety Relay for Machine Control Conforms to EN Standard. H Suitable for safety circuits in press

A4EG. Enabling Grip Switch. Enabling Grip Switch with Distinct Feel for Three Easily Discernible Positions. Ordering Information

CSM_D4N-_R_DS_E_6_1

D2AW. Long stroke seal switch with high reliability and high insulation performance. Model Number Legend. Sealed Ultra Subminiature Basic Switch

Type Contact form Enclosure ratings Model Standard SPST-NO (Class A) Flux protection G5LA-1A Sealed

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

D4NH. Model Number Structure. Safety-door Hinge Switch. Model Number Legend

Best-selling Basic Switch Boasting High Precision and Wide Variety

Emergency Stop Switch A165E. Ordering Information. Mounting Aperture of 16 mm

D2SW. Sealed Subminiature Basic Switch. Ordering Information Model Number Legend D2SW-

VERTICAL TYPE LIMIT SWITCHES (INCLUDES LAMP TYPE)

A165-E. Ordering Information. Emergency Stop Switch. For Panel Cutout of 16 mm

D2SW. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend

QL (AZ4) Limit Switches

D4NH. Safety-door Hinge Switch. Compact, Plastic-body Safety-door Hinge Switch Designed for Saving Space in Machines and Other Equipment

Miniaturized limit switches

Mechanical Key Switch

D4NS. Safety-door Switch. Multi-contact, Labor-saving, Environment-friendly, Next-generation Safety-door Switch. Model Number Structure

D4NH CSM_D4NH_DS_E_7_1

Safety Interlock Switches

QL (AZ4) Micro Limit Switches

G7S Safety Relay. Ordering Information. Safety Relay conforming to EN standard G7S. Accessories Safety Relay Sockets

Model Number Structure. Power Controllers G3PX. Single-phase Models. Model Number Legend

A165E CSM_A165E_DS_E_11_2

Transcription:

Small Limit Switch DV Compact Vertical Models Sized for Asian Standards Compact new design approximately / the size of OMRON vertical Limit Switches. Structure enables the terminal section to be fully opened for easy wiring. RoHS complaint. Degree of protection: IP6 Model Number Structure Model Number Legend DV-8@@Z. Actuator type 0: Roller lever 07: Rod lever 08: Adjustable roller lever : Push plunger 2: Roller plunger 22: Crossroller plunger 66: Coil spring 69: Wire spring Ordering Information List of Models Roller lever Actuator type Model DV-80Z Rod lever DV-807Z Adjustable roller lever DV-808Z Push plunger Roller plunger DV-8Z DV-82Z Crossroller plunger DV-822Z Coil spring DV-866Z Wire spring DV-869Z Note: Metallic roller levers and metallic variable roller levers can also be manufactured. Small Limit Switch DV

Specifications Certified Standards Certification body Standard File No. CCC GB08. Consult your OMRON UL UL08, representative for CSA C22.2 No. details. TÜV IEC6097-- Note: Certification equivalent to CSA C22.2 No. has been obtained from UL. Ratings Rated voltage (V) 2 VAC 20 VAC 2 VDC 2 VDC 2 VDC 20 VDC Non-inductive load (A) Inductive load (A) Resistive load Lamp load Inductive load Motor load NC NO NC NO NC NO NC NO 0. 0. 0.2 0.2. 0.7 0. Note:. The above current ratings are for steady-state current. 2. Inductive load has a power factor of 0. min. (AC) and a time constant of 7 ms max. (DC).. Lamp load has an inrush current of 0 times the steadystate current.. Motor load has an inrush current of 6 times the steady-state current. Inrush current NC NO 2 A max. 2 A max. Ratings for Safety Standard Certification CCC (GB08.), TÜV (EN6097--) Category and rating AC-2: 20 VAC at A, resistive load DC-2: 2 VDC at 0. A, resistive load UL (UL08, CSA C22.2 No. ) A, 20 VAC 0. A, 2 VDC Ratings 2. 0.8 Characteristics Degree of protection IP6 Durability Mechanical 0,000,000 operations min. (See note.) Electrical 00,000 operations min. ( A at 20 VAC, resistive load) Operating speed mm to 0. m/s Operating Mechanical 20 operations/min frequency Electrical 0 operations/min Insulation resistance 00 MΩ min. (at 00 VDC) Contact resistance 2 mω max. (initial value) Dielectric Between,000 VAC, 0/60 Hz for min strength terminals of the same polarity Between currentcarrying metal parts and ground,00 VAC, 0/60 Hz for min Rated insulation voltage 20 V (Ui) Pollution degree (EN 6097--) (application environment) Short-circuit protection 0-A fuse, gg or gi (IEC 269) device Conditional short-circuit 00 A (EN 6097--) current Rated open thermal A (EN 6097--) current (lth) Electric shock protection Class I class Rated frequency 0/60 Hz Vibration resistance Shock resistance Ambient operating temperature range Ambient operating humidity range Weight Malfunction 0 to Hz,.-mm double amplitude (See note.) Destruction,000 m/s 2 (free position) min. Malfunction 00 m/s 2 (operation limit position) min. (See note.) 20 C to 60 C (with no icing) 90% max. Approx. 0 to 90 g Note:. The above values are initial values. 2. The above characteristics may vary depending on the model. Contact your OMRON representative for further details.. Durability values are calculated at an operating temperature of C to C, and an operating humidity of 0% to 70%.. Except for the coil spring model and wire spring model 2 Small Limit Switch DV

Nomenclature Structure Contact Form Resin roller (NO) Za (NO) Lever Head (NC) 2 (NC) Built-in Switch Cover NO NC 2 NO NC Connector Engineering Data Electrical Durability: cos φ = (Ambient temperature: C to C; ambient humidity: 0% to 70%) Durability ( 0 operations),000 00 Operating frequencies: 0 operations/min 2 VAC, cos φ = 0 2 6 Switching current (A) Small Limit Switch DV

Dimensions Note: All units are in millimeters unless otherwise indicated. Roller Lever DV-80Z (2.) 2. R0 8-dia. 6.2 Three, M, P=0. M (length: ), hexagonal hole 9.6±0.8.±0.8 Four, M, 7. min. 8. Rod Lever DV-807Z.7 max. 2. 2.8±0.8 2.6 dia. 2..6±0.8 Four, M, M (length: 0), hexagonal hole 7. min. Three, M, P=0. M6 (length: 6), 8. hexagonal hole 6±0.2 6 6±0.2 6 (0.) (.) 2±0.2 Note: Resin Roller Four,.2-dia.7 2. 7.±0.8 (.) (0.) (.) 2±0.2 Four,.2-dia.7 2. (.) Adjustable Roller Lever Push Plunger DV-808Z Adjustable up to R0 to R7 2. 8-dia. 6.2 M (length: 0), hexagonal hole Three, M, P=0. M6 (length: 6), hexagonal hole 6.±0.8.6±0.8 Four, M, 7. min. 8. DV-8Z OP (.) 6±0.2 6.6 dia. R0.2 -M*P0. 8.7 0. 6 Four, M, 7. min. 6±0.2 (0.) (.) 2±0.2 Four,.2-dia.7 2. 6 (.) (0.) (.) 2±0.2 Four,.2-dia.7 2. (.) Note: Resin Roller.7±0.8 Roller Plunger Crossroller Plunger DV-82Z OP 2.-dia..9 Three, M, P=0. 8.7 0. Four, M, 7. min. DV-822Z OP 2. dia..9 Three, M, P=0. 8.7 0. Four, M, P=0.8 7. min. (.) (.) 6±0.2 6 6±0.2 6 (0.) (.) 2±0.2 Four,.2-dia.7 2. (.) (0.) (.) 2±0.2 Four,.2-dia.7 2. (.) Small Limit Switch DV

Coil Spring Wire Spring DV-866Z DV-869Z dia..2 dia.. 00 0.8 dia. Three, M, P=0..6 Four, M, 7. min. 8. Three, M, P=0. Four, M, 7. min. (77) (76) 6±0.2 6 6±0.2 6 Four,.2-dia (.) (0.) (.) 2±0.2.7 2. Note: The range for operation is between the tip of the rod and / of the length of the actuator. (0.) (.) Four,.2-dia 2±0.2.7 2. Note: The range for operation is between the tip of the rod and / of the length of the actuator. (.) Note: Unless otherwise specified, the tolerances are ±0. mm for the above dimensions for each model. Operating Characteristics Operating characteristics Model DV-80Z DV-807Z DV-808Z DV-8Z DV-82Z DV-822Z DV-866Z DV-869Z Operating force OF max..88 N.88 N 7.8 N 9.8 N 9.8 N 9.8 N 0.88 N 0.88 N Release force RF min. 0.9 N 0.69 N 0.9 N 2.9 N 2.9 N 2.9 N Pretravel max. 20 20 20. mm. mm. mm 0 mm 0 mm Overtravel OT min. 7 7 7 mm mm mm Movement differential MD max. 0 0 0.2 mm.2 mm.2 mm Total travel TT min. 9 9 9. mm. mm. mm Operating position OP 26±0.8 mm 7±0.8 mm 7±0.8 mm Note: The operating characteristics of the DV-807 are measured with a lever length of 0 mm. The operating characteristics of the DV-808 are measured with a lever length of R0. Small Limit Switch DV

Precautions Precautions for Correct Use Wiring Wiring Procedure. Loosen the cover mounting screws and remove the cover. 2. Run the wiring through the rubber connector on the cover and then press-fit the solderless terminals. (The following solderless terminals are available.). After inserting the solderless terminal into the Switch, tighten the terminal screws securely.. Mount the cover. (Make sure that the rubber connector is securely pressed into the cover slot.). Tighten the three screws evenly. (The optimum tightening torque for each screw is 0.9 to 0.9 N m.) Applicable Terminals The following solderless terminals can be used. (Do not use fork or any other type of terminals, otherwise an accidental disconnection resulting in a ground fault may result.) max. 6. max. Terminal with insulated grip.0 to.7 dia. max. 6. max. Appropriate Tightening Torque.0 to.7 dia. Cover Cover mounting screw If screws are too loose, they can lead to an early malfunction of the Switch, so ensure that all screws are tightened using the correct torque. Applicable Lead Wires Wire name Number of conductors Applicable wire Conductor size Finished outside diameter Vinyl cabtire cord (VCTF) 2 conductors conductors conductors 0.7 mm 2 Round, 6 to 9 dia. Vinyl cabtire cable (VCT) 2 conductors 0.7 mm 2 600-V vinyl-insulated sheath cable (VVF) Terminals 2 conductors dia.,.2 dia.,.6 dia. Rubber connector Note: Do not use wires containing silicone, otherwise a contact failure may result. No. Type Appropriate tightening torque Head mounting screw 0.9 to 0.9 N m 2 Cover mounting screw 0.9 to 0.9 N m Lever mounting screw 2. to 2.9 N m Terminal screw (M) 0.9 to 0.9 N m Switch mounting screw (M Allen-head bolt) 2. to 2.9 N m Note: In particular, when changing the direction of the Head, make sure that all screws are tightened again to the correct torque. Be careful not to allow any foreign substance to enter the Switch. 2 6 Small Limit Switch DV

Mounting. Front Surface Mounting. Through-hole Panel Mounting Mounting Hole Diagram M mounting nut Four,. dia. holes 2. Rear Surface Mounting M mounting bolt Mounting Hole Diagram 6±0. Four,. dia. holes M mounting bolt 6±0. 2±0. 2. Tap Panel Mounting Spring washer 2±0. All units are in millimeters unless otherwise indicated. Spring washer All units are in millimeters unless otherwise indicated. Note: The tap screws for the body are M, with a minimum depth of 7. mm. Use bolts with a length of the panel thickness t + 7 mm or less. M mounting bolt Spring washer Mounting Hole Diagram 6±0.2 2±0.2 Four, M tapped holes (P=0.7) All units are in millimeters unless otherwise indicated. Others Do not use the Limit Switch outdoors, otherwise the Limit Switch will be damaged by rust or ozone. The Limit Switch is not suitable in places exposed to the spray of rainwater, seawater, or oily water. Contact your OMRON representative if such specifications are required. If high-sealing performance is required along with shielded wiring or conduit wiring, use the DC or WL. Using the Switch Changing the Actuator Mounting Position (DV-80Z, DV-808Z, DV-807Z) By loosening the Allen-head bolt on the actuator lever, the position of the actuator can be set anywhere within the 60. Changing the Head Direction (DV-80Z, DV-807Z, DV-808Z) By loosening one screw (black) at a time, the head can be changed at 90 increments in any of the four directions. Rotation screw (black) Loosen the Allen-head bold. Operation Operate the coil spring and wire spring models between the tip of the actuator and / the length of the actuator and parallel to the direction of operation. Handling the bottom of the actuator or excessively pushing in the tip may lead to bending damage, deformation, malfunction, and deterioration of service life. Contact bouncing, chattering, or telegraphing may occur. Take steps so that incorrect signals are not detected on the circuit side if doing so will cause problems with the application. Note: Telegraphing refers to the phenomenon of the actuator being used and bouncing back after the operating body has passed, and moving to the operation point on the opposite side, which causes the contact to operate. Small Limit Switch DV 7