(FLB-1000 & FLB-5000)

Similar documents
u Rubber Dust Cap Standard protective dust caps are supplied with all receptacles.

CNG Receptacles L SERIES. Features. Listings and Certifications

ILB-5. u Easy Installation - the in-line breakaway has SAE-10 O-ring fittings for easy installation in line between the dispenser and nozzle.

u High-Flow - the flow path has been matched to provide ample flow for all NGV-1 Type 1 and Type 2 nozzles.

MODEL 11A REGULATOR

Data sheet. D-2011/05/ Date: 02/2013. Type TK16 CNG. CNG Fuelling Nozzle. for cars at self-service fuelling stations

General information about underground storage tank (UST) fueling systems in every day language.

Cylinder and Valve: AirHawk II Air Mask

Field Service Bulletin CNG and LNG Leak Repair Tutorial

2013 IMPCO Technologies, Inc. Page 1 of 20 EPR Repair Kit Instructions (PPI-122, Rev-B)

Stay-put scuff guard helps to protect the dispensers from scratches and the breakaway during a drive-off event

Welker Adjustable Probe with Check Valve and Welker Automatic Insertion Probe with Check Valve

2018 CNG Refueling High-Performance Components for Natural Gas Vehicles and Fueling Stations

Gas Actuated Valve Supplement

Escape Cylinder and Valve

DatA sheet. D-2011/05/ Date: 02/2013. Type TK10 CNG. CNG Fuelling Nozzle. for cars FUTURE. TECHNOLOGY. TODAY.

DATA SHEET. D-2011/05/ Date: 05/11. Type TSA6 CNG. Inline breakaway coupling. for bus and truck fuelling stations FUTURE. TECHNOLOGY. TODAY.

AVK SAUDI VALVES MANUFACTURING COMPANY

Conventional Fueling 11A 11B. 1A Automatic Nozzle

TWO-STAGE HYDRAULIC PUMP. RWP55-IBT-Air

XP-300 Series Sprinklers Installation & Service Instructions

SERVICE INSTRUCTIONS Air Motor

I-VIC300MS. Vic -300 MasterSeal Butterfly Valves WARNING SERIES 761

Data sheet. D-2011/05/ Date: 07/2013. Type TK4 CNG. CNG Fuelling Nozzle. for cars. WEH - We Engineer Hightech

DATA SHEET. D-2011/05/ Date: 05/11. Type TSA1 CNG. Breakaway coupling. for car fuelling stations FUTURE. TECHNOLOGY. TODAY.

Installation, Operation & Maintenance Manual for Flo-Max Couplers Model FM

Data sheet. D-2011/05/ Date: 07/2013. Type TK1 CNG. CNG Fuelling Nozzle. for time filling of cars. WEH - We Engineer Hightech

T60 REGULATOR REPAIR KIT INSTRUCTIONS

OPW CLEANE NERGY F UELING P RODUCTS

Alphanumeric Product Index CleanEnergy Fueling Products

TABLE OF CONTENTS. 3 Outlet Stainless Steel Body. 3 Outlet Ductile Body. 2 Outlet Ductile Body 2 Outlet Bronze Body

AMERICAN AVK COMPANY AVK SERIES 24 - HIGH PRESSURE, WET BARREL HYDRANT FIELD MAINTENANCE AND INSTRUCTION MANUAL TABLE OF CONTENTS

Firehawk Second Stage Regulator Fire Service

SD Bendix PP-7 Trailer Supply Valve FUNCTION AND DESCRIPTION

Pony Tank Operation Manual

Throttling Pendulum Gate O-ring Replacement Procedure Rev. A, May 2012

OPW CLEANE NERGY F UELING P RODUCTS

CIRCLE SEAL CONTROLS

I-731-D/W731-D. Suction Diffuser. Important Installation Information. series 731-D and W731-D

Installation, Operation & Maintenance Manual for Flo-Max Couplers Model FM

155 CARTRIDGE SINGLE SEAL

ANDERSON GREENWOOD SERIES 500 PILOT OPERATED SAFETY RELIEF VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

METERING VALVE 2" STEM GUIDED

DatA sheet. D-2011/05/ Date: 02/2013. Type TSA2 CNG. Inline breakaway Coupling. for car fuelling stations FUTURE. TECHNOLOGY. TODAY.

INSTALLATION INSTRUCTIONS FOR THE TRUCK MOUNTED VIPER ADDITIVE INJECTION SYSTEM GTP-8776C

Instructions for Installation, Operation, Care and Maintenance

FireHawk M7XT Ultra Elite XT Facepiece

OWNER S MANUAL. ROTARY SURFACE CLEANER Models 105C, 105F, 105CW, & 105FW. Revision 2.01

Fast-Flo Pump INSTRUCTIONS-PARTS LIST. Table of Contents 1:1 RATIO

Data sheet. D-2011/05/ Date: 02/2013. Type TSA6 CNG. Inline breakaway Coupling. for bus and truck fuelling stations

Ultra Elite Facepiece: AirHawk II Air Mask

Backpack Sprayer. Use and Care Manual

Instructions Parts List

Welker Jet Insert Model Control Valve

Table of contents. Introduction 2. Instrumentation 4. Servicing your vehicle 5

MODEL C-COBRA SERIES CONVERTER REPAIR KIT INSTRUCTIONS

I-VIC300MS. Series 761 Vic-300 MasterSeal Carbon Steel Butterfly Valve Series 461 Vic-300 MasterSeal Stainless Steel Butterfly Valve WARNING

DAH Left Hand Hose Inlet Kit Instruction Sheet For Use with 700 SERIES DAH Dilution at Hand Blend Centers

Type 0283, Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

SAFETY MANUAL READ FIRST!

Plastic Collar Quick Connect Fitting Service

BOSTON TOWER MERCHANDISER ILLUMINATION KIT (P/N ) INSTALLATION INSTRUCTIONS

FT150 MIXER REPAIR KIT INSTRUCTIONS

PRESSURE REGULATOR BACK PRESSURE TO ATMOSPHERE WITH OUTSIDE SUPPLY

2012 Chevrolet/GMC Express/Savana CNG Compressed Natural Gas Supplement M

BLACKMER PISTON AIR/RELIEF VALVE (w/o spring) CONVERSION KIT SAFETY DATA. For Pump Models: TXH3C, TXH3B, TXH3A, TXD2.5A, TXD1225A

Installation For Service Only

English. Fitting Instructions: Street Triple Rx, Street Triple from VIN and Street Triple R from VIN A , A and A

OPW Installation and Maintenance Instructions OPW Series Primary and Secondary Bucket Replacement Instructions

INSTALLATION/OPERATION/MAINTENANCE INSTRUCTIONS FOR ARCHON MODELS WD2010L, WD2010, WD2010H WASHDOWN STATIONS. ARCHON Industries, Inc.

SD Bendix SR-5 Trailer Spring Brake Valve DESCRIPTION PORTS. 1-1/2" or 3/4" NPT Spring Brake Reservoir Mounting (SPR BK RES)

300 Series INSTRUCTION MANUAL. Compressed Air Filters Models 302 (grade) through 317 (grade)

INSTALLATION & MAINTENANCE MODEL mm

Scope. Applicability. Caution. I & M CV3000 Series. Storage. Installation & Maintenance Instructions for Marwin CV3000 Series Three Piece Ball Valves

1" QickZone Modular Brass Manifold Installation Instructions Parts List

EP1306N 5 Gallon Can Extruder System Rev. A June EP1306N Operation Manual

KAM IAS ISOKINETIC AUTOMATIC SAMPLER. User Manual IASMANUAL-0513 KAM CONTROLS, INC Ann Arbor Drive Houston, Texas USA

Garden Hose Reel with 3/4In. x 100Ft. Hose. Owner s Manual

Service Manual Air Plus Second Stage

AIR/HYDRAULIC INJECTION GUN MODEL INSTRUCTIONS

Table of Contents General Information Safety Message Classifi cation...2 Safety Notes...3 Terminology...4 Coupler Lifting Lug...

PNEUMATIC SLIDING VALVE

English. Fitting Instructions: Tiger 800 and Tiger 800XC A of 8. Parts Supplied:

Owner s Manual WARNING

OWNER S MANUAL: Model # JGSBSEAR Searing Burner Station

Data sheet. D-2011/05/ Date: 02/2013. Type TSA5 CNG. Breakaway Coupling. for bus and truck fuelling stations FUTURE. TECHNOLOGY. TODAY.

MODELS 9917, , 9946P and 9989 High Pressure Lubrigun Series A

Welker Probe Instrument Regulator with Liquid Eliminator Cartridge

Temperature Sensor Series

FUEL KITS P/N & 526-4

Application Note Original Instructions. Gas Fuel Control Valve (GFCV) O-ring Field Replacement Procedure

WCI-20 Power-Pak Coldwork Hydraulic Power Supply Rev B

Oil Control Handle with Mechanical Meter. Introduction. General Information. Important Information 3575-A 3575-B 3575-C 3575-D

: 1250 gpm in the deck mode : 800 gpm while operating in the ground base - Dual Inlet : 1000 gpm while operating in the ground base - Single Inlet

HIGH PRESSURE CONTROL VALVE PISTON BALANCED

Model DV-5 Deluge Valve, Diaphragm Style, 1-1/2 thru 8 Inch (DN40 thru DN200), Deluge System Electric Actuation

Installation, Operation & Maintenance Manual for Flo-Max II Coupler Model FM126

LOW PRESSURE BALANCED VALVE DIAPHRAGM BALANCED

Field Service Bulletin

INSTALLATION INSTRUCTIONS

Transcription:

INSTALLATION INSTRUCTIONS FOR QUALIFIED TECHNICIANS FOR CNG FILL- LINE BREAKAWAY DEVICES (FLB-1000 & FLB-5000) 207943 JULY 2014, REV C ANSI/1AS NGV 4.4-1999 CSA 12.54-M99 FOR USE WITH ANY CERTIFIED ELECTRICALLY CONDUCTIVE HOSE INTENDED FOR FILLING COMPRESSED NATURAL GAS VEHICLES UP TO SERVICE PRESSURE OF 5000 PSI SECTION A: INTRODUCTION How to use this Manual: This manual has been prepared as a step by step users guide for the OPW FLB series of CNG Fill-Line Breakaway valves. This information is intended as a general outline to familiarize the installer/end user with the techniques and procedures used to install, reconnect and maintain the Breakaway device. General: The FLB ( Breakaways ) series of breakaways are intended to protect the dispenser, vehicle, fueling nozzle and end-user from damage if a vehicle moves away from the refueling point while the fueling nozzle is still coupled to the vehicle s fueling receptacle. The Breakaways are designed to be used with any certified hose intended for filling compressed natural gas vehicles (CNGV). The Breakaways operate at service pressure up to 5,000 psi and has an operating temperature range of -40 C to 85 C (- 40 F to 185 F). These Breakaways are designed to separate within the range of 120 ±30 lbs. (534 ±134N) as specified by the ANSI NGV4.4, Breakaway Device Safety Standard. SECTION B: INSTALLATION The Inlet & Outlet Connections and Seals for the FLB s are as follows: BREAKAWAY ITEM INLET/OULET SEAL FLB-1000 SAE J1926-6 O-Ring boss Port, 9/16-18 UNF Threads Size # 906 (P/N 001146) 70 durometer NBR Nitrile FLB-5000 SAE J1926-10 O-Ring boss port, 7/8-14 UNF Threads Size # 910 (P/N 001127) 70 durometer NBR Nitrile CAUTION: THE BREAKAWAYS MUST BE CONNECTED BETWEEN THE DISPENSER AND THE NOZZLE SO IT IS FREE TO ALIGN ITSELF IN A STRAIGHT MANNER BETWEEN ITS TWO HOSES (FIG.1). All Breakaways require special installation precautions to ensure safe and reliable operation. The proper installation will conform to the requirements of authorities having jurisdiction or in the absence of requirements with the NFPA 52 standard, Compressed Natural Gas (CNG) Vehicular Fuel Systems, or CAN/CSA-B108, NGV fueling stations installation code as applicable. INSTALLATION PROCEDURE: Step 1: Inspect the unit and ensure that both halves are fully connected. If you can easily pull the two halves apart then please refer to SECTION D - Reassemble before continuing with the installation. Step 2: Ensure that the threads on both the hose fitting, as well as the inlet and outlet ports, are clean and free of any debris, oil, grease or Teflon tape. Step 3: Ensure that the proper sealing O-rings are installed on the male hose fittings according to the fitting 1

and O-ring manufacturer s instruction. These O-rings must be 70 Durometer Nitrile (NBR). Two of these O-rings are included with each Assembly instruction sheet and must be installed. For additional O-rings contact OPW Customer Service. Order Part # 001146 for FLB-1000 and Part # 001127 for FLB-5000. Step 4: Only use the wrench flats when tightening the hose to the Breakaways - do not grasp the housing. Step 5: Ensure the flow direction arrow is pointing in the direction of the natural gas flow. (The arrow should point toward the fueling nozzle) (Fig.2) Step 6: Using a properly sized wrench, tighten the fitting to a torque 25 ft-lbs. (34 Nm) to 30 ft-lbs. (40 Nm). Warning: a. Excessive over tightening will gall the threads and weaken the connection b. Do not wrench across coupling Step 7: After installation, test the unit for leaks. Slowly pressurize and test the connection using a suitable leak detector (e.g. Snoop ). The test pressures should include both Low (100 psi /0.86 Mpa) and High (3,000-5,000 psi/20-35 Mpa). For safety reasons, always pressurize at the low pressure first. FIGURE: 1 FIGURE: 2 NOTE: IF A HOSE RETRACTOR IS USED IN THE DISPENSING APPLICATION THE BREAKAWAYS SHOULD BE INSTALLED DOWNSTREAM OF THE HOSE RETRACTOR CLAMP, I.E. BETWEEN THE RETRACTOR CLAMP AND THE NOZZLE. THIS WILL ALLOW THE BREAKAWAYS TO FUNCTION AS DESIGNED. SECTION C: SEPARATION OF FLB The Breakaways will split into two parts upon disconnection when a pull force of 120±30 lbs. (534±134N) is applied axially to the breakaway coupling. (Fig. 3) 2

FIGURE: 3 The (Fig. 3) is the portion that remains permanently attached on the dispenser side of the hose. It shuts off the flow of natural gas from the dispenser. The (Fig. 3) on the vehicle side of the hose will detach and slowly vent off the gas stored in hose and nozzle that remain coupled to the vehicle. This is to ensure that the driver is not carrying a pressurized hose away from the station, thus eliminating a dangerous situation. NOTE: UPON SEPARATION, A VERY LOUD NOISE SHOULD BE EXPECTED. CAUTION: A HOSE BREAKAWAY EVENT IS INTENDED TO PROTECT THE FUELING DEVICE, DISPENSER, VEHICLE AND END-USER. HOSE STRETCH WILL CAUSE A WHIPPING ACTION FOR THE BREAKAWAY HOUSING. AS A RESULT, PERSONAL INJURY MAY OCCUR IF SOMEONE IS IN THE WAY OF THE HOSE DURING A BREAKAWAY EPISODE. RECONNECTION PROCEDURE: SECTION D: RE-ASSEMBLY AFTER BREAKAWAY Step 1: Depressurize the dispenser system and hose before attempting reconnection. Step2: Remove (Fig. 3) from the vehicle side of the hose. FIGURE: 3 Step 3: Remove the retaining ring and cover from the. (Fig. 4) 3

Cover Body Retaining Ring FIGURE: 4 Step 4: Clean dirt or debris from both halves of the Breakaway unit before re-assembly is attempted. Step 5: Inspect the Breakaway and s for any damage. (Fig. 5) FIGURE: 5 Step 6: Make sure the O-ring seals have not been damaged (slits or rough spots). (Fig. 6) If the o-rings are damaged, please contact OPW Customer Service for replacements. For the FLB-1000 order Part # 207983 Repair Kit and for the FLB-5000 order Part # 207739 Repair Kit (See details below). If the O-rings are dry, lubricate them with the light grease, Parker Super O-Lube (Silicon Base), before re-assembly. (Note: O-Ring Pick, Loctite 270, Parker Super O-Lube (Silicon Base) are not included with repair kits). O-Rings 4

FIGURE: 6 Step 7: Inspect the and ensure that the inner canted coil spring is present and properly situated in the groove (Fig. 7). A replacement Canted Coil Spring is available from OPW customer service. For FLB-1000 & FLB-5000 spring Part # 207629. Canted Coil Spring FIGURE: 7 Step 8: Reassemble cover on using retaining ring. Step 9: Align Wrench Flats on to Anti-Rotation Tabs on (Fig.8) Anti-Rotation Tabs Wrench Flats FIGURE: 8 Step 10: Push the Breakaway Module into the Stationary Module until a definite click is felt and the wrench flats are in the groove on the. Approximately 20 ft. lbs. of force are required to reconnect breakaway. Step 11: After Reassembly, test the Breakaways for leaks. Slowly increase the system pressure in steps of 500 psi and test the connection using a suitable leak detector (e.g. Snoop ). The test pressure should start at low (100 psi/0.86mpa) first and finish at fill line pressure (3,000psi-5,000psi/20Mpa-35Mpa). For safety reasons, always apply the pressure slowly and take your time checking for leaks to ensure a good reconnection has been made. 5

KIT PART NUMBER : 207983 (FLB-1000 REPAIR KIT) SR NO PART NUMBER DESCRIPTION QUANTITY 1 001146 O-RING 2 2 207629 CANTED COIL SPRING 1 3 208182 O-RING 3 4 208179 O-RING 1 5 208183 O-RING 1 6 207231 O-RING 2 7 206906 RETAINING RING 1 8 207222 OUTLET POPPET 1 9 207223 SPRING SUPPORT 1 10 207965 INSTRUCTION SHEET 1 KIT PART NUMBER : 207739 (FLB-5000 REPAIR KIT) SR NO PART NUMBER DESCRIPTION QUANTITY 1 001127 O-RING 2 2 207629 CANTED COIL SPRING 1 3 208184 O-RING 3 4 208085 O-RING 1 5 208186 O-RING 1 6 207195 RETAINING RING 1 7 207188 OUTLET POPPET 1 8 207189 SPRING SUPPORT 1 9 207965 INSTRUCTION SHEET 1 SECTION E: ROUTINE CHECKS Routine Service: As part of the end-user s preventative maintenance program/schedule, the Breakaways should be routinely checked for damage or leaks by a qualified technician After Four Years of Service: The unit should be returned to OPW for Rebuilding. Please contact OPW Customer Service for assistance. This period should be reduced to 24 months if the potential exists for misuse, abuse, if the Breakaways are used in extreme environmental surroundings. 9393 PRINCETON-GLENDALE RD. HAMILTON, OH 45011-9707 800-422-2525 6