Power Modules (Power Supplies with Ultra-low Standby Power Consumption) DC V

Similar documents
BPM2417SJ Datasheet. Power Modules (Power Supplies with Ultra-low Standby Power Consumption) TAMURA CORPORATION Rev.

MPM0527SJ Datasheet. Power Modules (Power Supplies with Ultra-low Standby Power Consumption) TAMURA CORPORATION Rev.

EPM1510SJ Datasheet. Power Modules (Power Supplies with Ultra-low Standby Power Consumption) TAMURA CORPORATION Rev.

Maximum input voltage 420V or less Including peak value

No-load power 50mW or less (17mW TYP) Rated input voltage. Ripple noise 300mVp-p or less Rated output current

Efficiency More than 80% Rated input voltage Rated output current Output voltage tolerance ±5%

DM Series Gate Driver Module

Five Improvements by Power Supply Modules. Switching power supply and power modules. External Dimensions / Pin assignment, SPM Series

Absolute Maximum Ratings Item Symbol Min Max Unit Conditions Note Input voltage for DC/DC converter V IN Vdc Between Vin(+) to Vin(-)

Applications. Output Voltage (V) V21 = 2

RP Instruction Manual

EVS RP6020. Instruction Manual

THT-500-A/R INSTRUCTION MANUAL TEMPERATURE AND HUMIDITY TRANSMITTER

(DC/DC) SERIES to 96.5% (typical) Product Lineup. Ordering Information. Features. General Description. Super high efficiency

DC/DC Converter Application Information

DC/DC Converter Application Information

DATA SHEET FUSIBLE ALLOY THERMAL SENSITIVE PELLET TYPE, 2 AMPERES RATED CURRENT

<Designed to meet harmonic current regulations> Board type, ultra-small size, and low cost

MYPMA01218RCF-CAB Non-isolated type

DRB-1 Series Instruction Manual

DATA SHEET ORGANIC THERMAL SENSITIVE PELLET TYPE 10 AMPERES RATED CURRENT

ACTIVE ORING CONTROLLER MODULE

DRL-1 Series Instruction Manual

S-8209B Series Usage Guidelines Rev.1.5_02

Features. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter

Ratings 0402 inch size : Type ERBRD ERBRD R X 0R25 0R3 0R37 0R50 0R75 R00 R25 R50 2R00 2R50 3R00 Rated Current (A)

Switching Power Supply

MEMS Gauge Pressure Sensor

Metal Film Fuse Resistors

Basic Characteristics Data

3. Block Diagram Pin Number, Function Pin No. Symbol Function 4. Environmental Conditions 1 Vin1 Ch1 Voltage Input Terminal 2,3 Vin23 Ch2,3 Voltage In

Small Type High-Speed Response POL DC-DC Converter BSV-nano Series

User s Manual Power Supply. IM E 3rd Edition. Yokogawa Electric Corporation

DC/DC Converter Reference Circuit

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 2831D 4 ½ Digit True RMS Digital Multimeter

TDK-Lambda ZWS240BP/A SPECIFICATIONS

DC9~ typ max 40max 80max. 71 typ max. 120max 120max. 120max. 120max. 60max. 48max. 20max

Basic Characteristics Data

DC-DC Converter DATA Sheet

C B. Operating up to 5000m altitude 5 year product warranty Models

LS200 Series Instruction Manual

User s Manual Power Supply IM E. 5th Edition

Ordering Information. Switching Power Supply S82F. Industrial-Grade Power Supply for General or Peak Load Applications SWITCHING POWER SUPPLIES

Ordering Information. MEMS Gauge Pressure Sensor 2SMPP. MEMS Gauge Pressure Sensor Featuring Small Size and Low Power Consumption

Ordering Information. Text PCB Power Relay G5RL. Low-profile Relay with Various Models. Power Relays

User s Manual Power Supply. IM E 2nd Edition. Yokogawa Electric Corporation

Pressure Sensor/PS-A (ADP5)

1 Terminal Block A-22

Output Current Input Current Over Load VDC VDC ma ma(typ.) ma(typ.) VDC μf %

High Temperature Film Capacitor for Automotive

DC-DC Converter DATA Sheet

PS6R 480W Switching Power Supply

DC-DC Converter DATA Sheet

Output Current Input Current Reflected Ripple. VDC VDC ma ma(typ.) ma(typ.) ma(typ.) VDC μf %

CCG Series Instruction Manual

DC-DC CONVERTERS 4:1 WIDE INPUT RANGE UP TO 9 WATTS SINGLE AND DUAL OUTPUT, SIP PACKAGE SWB9 SERIES

Table 2 Models BST12M-0.7S03PDM BST12M-0.7S06PDM BST12M-0.7S10PDM Conditions Input voltage range

HWS 15A-150A Series. Instruction Manual

Ordering Information. MEMS Gauge Pressure Sensor 2SMPP. MEMS Gauge Pressure Sensor Featuring Small Size and Low Power Consumption

Notice for TAIYO YUDEN Products

Selection Guide SANKEN ELECTRIC CO.,LTD

Input Voltage Range V. Output Voltage 3.3 V R1+R2=71.3kΩ, R3=22kΩ 7.0 (V IN 0.65) Output Current Range A

TC RELAYS. TYPICAL APPLICATIONS Head lamp, Fog lamp, Fan motor, Defogger, Seat heater, etc. ORDERING INFORMATION. High Load Relay for Smart J/B ACTC

DC-DC CONVERTERS 2:1 INPUT RANGE, UP TO 2 WATTS MEDICAL APPLICATIONS MTWA2 SERIES

HL (AZH) Limit Switches

Load (2) Single or Dual

Contents. Introduction Inspection Notes on Safety Precautions. Chapter 1 Overview Product Overview Names of Parts 2

Basic Characteristics Data

Specifications 2019-V AC-DC Din Rail Mounted Power Supply IS-480 Series, 480W

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa

Output Current Input Current Reflected Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S033

PFE700SA Series Instruction Manual

350W Slim Type with PFC Switching Power Supply

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit

No.LV31JE To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual.

G3PE-Single-phase. Solid State Relays for Heaters

PG02S Series 2W DC/DC CONVERTER, SIP-Package

Output Current Input Current Reflected Ripple. Efficiency (typ.) (Range) VDC VDC ma ma(typ.) ma(typ.) ma(typ.) VDC μf % MTQZ50-72S05

Output Current Input Current Reflected Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S033

Packaging (1) Package

AC/DC Converter MBP250-2A13D13M

Input terminals Isolation method Zero cross function Operation indicator Alarm output Applicable load (See note.) Model

INDUSTRIAL POWER SUPPLIES SFL-SERIES

DPX30-xxSxx DC-DC Converter Module 9.5 ~ 18 VDC and 18 ~ 36 VDC and 36~ 75 VDC input; 3.3 to 28 VDC Single Output; 30 Watts Output Power

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

Efficiency(1) Max. Capacitive. Package(3) CTRL Logic(2) Single

Note1: Efficiency is tested by nominal Vin, full load and at 25 C. Package (3) CTRL Logic (2)

DPX30-xxDxx DC-DC Converter Module 9.5 ~ 18 VDC and 18 ~ 36 VDC and 36~ 75 VDC input; ±12 to ±15 VDC Dual Output; 30 Watts Output Power

Solid State Relays G3RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. SSR and Socket Combinations

VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S

Specifications 2019-V AC-DC Din Rail Mounted Power Supply IS-70 Series, 70W

MJWI20 SERIES FEATURES PRODUCT OVERVIEW. DC/DC Converter 20W, Highest Power Density MINMAX MJWI20 Series

DPX30-xxWSxx DC-DC Converter Module 10 ~ 40VDC, 18 ~ 75VDC input; 3.3 to 28VDC Single Output 30 Watts Output Power

CN100A110 SERIES Instruction Manual

PRODUCT SPECIFICATION OUTPUT CURRENT (A) OUTPUT CURRENT TOLERANCE ±7% ±7% ±10% ±10% ±7% 1.8. Units % % % Typ. Typ.

ZWD100PAF. Conformity to RoHS Directive

output Output Voltage min (ma)

2 to 25 A, 100 to 240 VAC G3PF-225B-STB Compact slotted

User's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model

Note1: tested at nominal Vin, full load and at +25 C ambient. Package (3) CTRL Logic (2)

Transcription:

Power Modules (Power Supplies with Ultra-low Standby Power Consumption) Features 1.Easy to design compact AC/DC due to small number of external components 2.Enables significant reduction in power consumption of no-load and light load 3.Corresponding world wide input and PFC output voltage (Vin:DCV~4V) 4.Unique Tamura design insures significant reduction in buzz under light-load conditions for lower noise level 5.Reinforced insulation Applications Industrial equipment Information processing equipment AV equipment Home electric appliances Other standby power supplies and compact power supplies Certified safety standards UL62368-1, CSA C22.2 No.62368-1 (E132244) UL695-1, CSA C22.2 No.695-1 (E132244) IEC62368-1(CB), IEC665(CB) Certified input voltage range DC-4V Applicable safety standards UL/CSA/IEC/EN62368-1 UL/CSA/IEC/EN695-1 UL/CSA/IEC/EN665 IEC/EN6335-1 Applicable input voltage range DC-4V Application circuit Method to select external parts for input rectification and smoothing as well as output smoothing is supported by the application note. 1 / 9

Input-output condition Item Specification Conditions Note Input voltage range DCV~4V Average voltage (DC5V~4V) (Refer to the Input voltage derating curve) Maximum input voltage 4V or less Including peak value Input ripple voltage lower limit Rated input voltage Rated output voltage Rated load current 75V or more DC1V, DC3V 5V 8A Ripple voltage of the AC input rectified Electrical specification Ta=25 Item Specification Conditions Note Efficiency 85% or more (87% TYP) Rated input voltage Rated output current Output voltage tolerance ±5% Line regulation 5mV or less Input voltage DCV~4V Load regulation mv or less Output current ~8A No-load power 5mW or less (25mW TYP) Rated input voltage Ripple 6mVp-p or less Rated input voltage Ripple noise mvp-p or less Rated output current Measurement circuit DCV~DC4V 1 Vin(+) Module Vo 13 12 L1 Vo V1 E1 W1 C2 2 Drain 11 C1 C2 C3 P1 LM1 RL1 3 Vin(-) GND 9 GND 4 Vcc RC(+) 14 5 VccW REF 7 6 NC RC(-) 8 C4 C3 E1 : DC power supply W1 : Power meter WT2 (YOKOGAWA) RL1: Electronic load V1 : Voltmeter Class.5 P1 : Differential probe DP-(KG) LM1: Ripple noize meter RM-3(KG) C2 : 45BXWM (RUBYCON) C3 : CD45-B2GA331K (TDK) C4 : CD45-B2GA331K (TDK) C1 : ZLG2M (RUBYCON) C2 : ZLG2M (RUBYCON) C3 : ZLG2M (RUBYCON) C4 : ZLG2M (RUBYCON) C5 : ZLGM (RUBYCON) L1 : PC8Z-1RN (KORIN) 2 / 9

Protection Item Specification Conditions Note Overcurrent protection 8A or more Hiccup mode Overvoltage protection 5.75~7.5V Latch off Overheat protection Latch off Insulation Item Specification Conditions Note Dielectric withstand voltage AC3.kV 1min Cutoff 2mA (Between Pri-Sec) Insulation resistance MΩ or more DC5V (Between Pri-Sec) Environmental conditions Item Specification Conditions Note Operating temperature - ~8 Refer to the Ambient temperature derating curve Operating humidity Storage temperature Storage humidity ~95%RH (No condensation) -25 ~85 5~95%RH (No condensation) Ambient temperature derating curve Reduce the load current according to the following temperature derating table. Input voltage derating curve Reduce the load current according to the following input voltage derating table. 8 8 Load factor(%) 6 Load factor(%) 6 - - 3 5 6 7 8 Ambient Temperature( ) 5 6 7 8 9 1 1 ~ Input voltage(vdc) 3 / 9

Output Voltage [V] [V] Efficiency [%] Output Voltage [V] Input Power [W] Efficiency [%] Input Power [mw] Typical characteristics Ta=25 9 Efficiency 5 Input power (at no load) 8 7 6 5 DC1V DC3V 3 3 1 2 3 4 5 6 7 8 15 25 3 35 45 Output Current [A] Input Voltage VDC [V] 5.25 5. 5.15 5. 5.5 5. Load regulation DC1V DC3V 1..9.8.7.6.5 Input power (at light load) 4.95 4.9 4.85.4.3.2 DC1V DC3V 4.8.1 4.75 1 2 3 4 5 6 7 8. 5 15 Output Current [A] Output Current [ma] Line regulation 5.25 Line regulation 25.2 5. No load (A) 25. 5.15 Rated load (8A) 24.8 5. 24.6 5.5 24.4 24.2 5. 24. 4.95 23.8 4.9 23.6 4.85 23.4 4.8 23.2 23. 4.75 22.8 15 25 3 35 45 15 25 3 35 45 Input Voltage VDC [V] Input Voltage VDC [V] 9 8 7 6 5 3 Efficiency (at light load) DC1V DC3V 5 15 Output Current [ma] 4 / 9

Outline dimensional drawing Unit:mm 5 / 9

Recommended hole diameter and land size The round pulling out figure is a pin numbering. Component side Unit:mm Terminal function and connection Primaries Pin No. Name Explanation of terminals 1 Vin(+) 2 Drain DC voltage input terminal (+) Terminal for noise adjustment 3 4 Vin(-) Vcc DC voltage input terminal (-) Terminal for start-up time adjustment 5 VccW 6 N.C. Auxiliary winding terminal Unused terminal Don't connect with other circuits. Don't connect with other circuits. Secondaries Pin No. Name Explanation of terminals 7 REF 8 RC(-) 9 GND GND 11 GND 12 Vo 13 Vo 14 RC(+) Output voltage adjustment terminal Output voltage detection terminal (-) Output terminal (-) Output terminal (-) Output terminal (-) Output1 terminal (+) Output1 terminal (+) Output voltage detection terminal (+) 6 / 9

Application circuit example AC9V~AC264V (5/6Hz) L F1 TH1 L1 D1 1 Vin(+) Module Vo 13 12 L1 L2 Vo C1 C2 2 Drain 11 C1 C2 C3 C4 C5 N 3 Vin(-) GND 9 GND 4 Vcc RC(+) 14 5 VccW REF 7 6 NC RC(-) 8 C4 C3 Symbol Description Part No. Manufacturer D1 Diode D2SB6A SHINDENGEN L1 Inductor HL-24R-ETHA KORIN L1 Inductor PC8Z-1RN KORIN L2 Inductor TC-87- KORIN C1 Capacitor LE4-MX OKAYA C2 Capacitor BXWM RUBYCON C3 Capacitor CD45-B2GA331K TDK C4 Capacitor CD45-B2GA331K TDK C1 Capacitor ZLG2M RUBYCON C2 Capacitor ZLG2M RUBYCON C3 Capacitor ZLG2M RUBYCON C4 Capacitor ZLG2M RUBYCON C5 Capacitor ZLGM RUBYCON F1 Fuse FIH 25V 2.A NIPPON-SEISEN TH1 Thermistor SCK2R55AM THINKING Mount the fuse on the input Live side to ensure safety without fail. Recommended parts:fih 25V 2.A~3.15A / NIPPON-SEISEN Depend on the applying safety standard, please add the discharge resistance in paralell with C1. 7 / 9

Usage cautions Always mount fuse on the Live side of input for ensuring safety because the fuse is not built-in the product. Please select the fuse considering conditions such as steady current, inrush current, and ambient temperature at your own respons Recommended parts: FIH 25V 2.A~3.15A / NIPPON-SEISEN When using a fuse having large rated current or high capacity input electrolytic condenser, by combining another converter and input line and input electrolytic condenser, fuse may not blow off in the case of abnormality. Do not combine high voltage line and fuse. Important notice The content of this document is subject to change without prior notice for the purpose of improvements, etc. Ensure that you are in possession of the most up-to-date information when using this product. The operation examples and circuit examples shown in this document are for reference purposes only, and TAMURA Corporation disclaims all responsibility for any violations of industrial property rights, intellectual property rights and any other rights owned by TAMURA Corporation or third parties that these may entail. The circuit examples and part constants listed in this document are provided as reference for the verification of characteristics. You are to perform design, verification, and judgment at your own responsibility, taking into account the various conditions. TAMURA Corporation constantly strives to improve quality and reliability, but malfunction or failures are bound to occur with some probability in power products. To ensure that failures do not cause accidents resulting in injury or death, fire accidents, social damage, and so on, you are to thoroughly verify the safety of their designs in devices and/or systems, at your own responsibility. This product is intended for use in consumer electronics (electric home appliances, business equipment, Information equipment, communication terminal equipment, measuring devices, and so on.) If considering use of this product in equipment or devices that require high reliability (medical devices, transportation equipment, traffic signal control equipment, fire and crime prevention equipment, aeronautics and space devices, nuclear power control, fuel control, in-vehicle equipment, safety devices, and so on), please consult a TAMURA sales representative in advance. Do not use this product for such applications without written permission from TAMURA Corporation. This product is intended for use in environments where consumer electronics are commonly used. It is not designed for use in special environments such as listed below, and if such use is considered, you are to perform thorough safety and reliability checks at your own responsibility. Use in liquids such as water, oil, chemical solutions, or organic solvents, and use in locations where the product will be exposed to such liquids. Use that involves exposure to direct sunlight, outdoor exposure, or dusty conditions. Use in locations where corrosive gases such as salt air, C12, H2S, NH3, SO2, or NO2, are present. Use in environments with strong static electricity or electromagnetic radiation. Use that involves placing inflammable material next to the product. Use of this product either sealed with a resin filling or coated with resin. Use of water or a water soluble detergent for flux cleaning. Use in locations where condensation is liable to occur. This product is not designed to resist radiation. This product is not designed to be connected in parallel. Do not operate this product in a parallel, or N+1 redundant configuration. 8 / 9

Do not use or otherwise make available the TAMURA products or the technology described in this document for any military purposes, including without limitation, for the design, development, use, stockpiling or manufacturing of mass destruction weapons (e.g. nuclear, chemical, or biological weapons or missile technology products). When exporting and re-exporting the products or technology described in this document, you should comply with the applicable export control laws and regulations and follow the procedures required by such laws and regulations including, without limitation, Japan -Foreign Exchange and Foreign Trade Control Law and U.S.- Export Administration Regulations. The TAMURA products and related technology should not be used for or incorporated into any products or systems whose manufacture, use, or sale is prohibited under any applicable domestic or foreign laws or regulations. Please contact your TAMURA sales office for details as to environmental matters such as the RoHS compatibility of product. Please use TAMURA products in compliance with all applicable laws and regulations that regulate the inclusion or use of controlled substances, including without limitation, the EU RoHS Directive. TAMURA assumes no liability for damages or losses occurring as a result of your noncompliance with applicable laws and regulations. TAMURA assumes no liability for damages or losses incurred by you or third parties as a result of unauthorized use of TAMURA products. This document and any information herein may not be reproduced in whole or in part without prior written permission from TAMURA. 9 / 9