Specifications 2019-V AC-DC Din Rail Mounted Power Supply IS-480 Series, 480W

Similar documents
Specifications 2019-V AC-DC Din Rail Mounted Power Supply IS-70 Series, 70W

D R C- 4 0 s e r i e s

UCS-CHR24V55W. Combined Power Supply & Battery Charger. Data Sheet

LPF-25 series. 25W Constant Voltage + Constant Current LED Driver

DIN Rail Power Supplies

Video & Power Over Coax Kit

SELV IP30 (CCC optional)

IS 15885(Part 2/Sec13) R ( for 24V only)

LS200 Series Instruction Manual

POWER-WIN TECHNOLOGY CORP.

MODEL SELECTION TABLE Open Frame Models. MODEL SELECTION TABLE U-Chassis Models. MODEL SELECTION TABLE Enclosed Models

PRODUCT SPECIFICATION OUTPUT CURRENT (A) OUTPUT CURRENT TOLERANCE ±7% ±7% ±10% ±10% ±7% 1.8. Units % % % Typ. Typ.

INDUSTRIAL POWER SUPPLIES SFL-SERIES

RUZ- _/_ Protection (3) Isolation Option (4)

Output Current Input Current Over Load VDC VDC ma ma(typ.) ma(typ.) VDC μf %

UHP-500 series. 500W Slim Type with PFC Switching Supply

Features. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter

350W Slim Type with PFC Switching Power Supply

UHP-200 series. 200W Slim Type with PFC Switching Power Supply. File Name:UHP-200-SPEC GB4943 EN EN UL IEC

Switching Power Supplies

Max. Output Power. Efficiency (1) 110Vac 220Vac. 450 ma 90 ~ 305 Vac 445 Vdc 200 W 92% EUC-200S045ST

POWER-WIN TECHNOLOGY CORP.

TRC ELECTRONICS, INC DC/DC Converter SIP Package 6W MEAN WELL SPBW06 & DPBW06 Series

UHP-350 series. 350W Slim Type with PFC Switching Power Supply

AC/DC Converter MBP250-2A13D13M

TDK-Lambda ZWS240BP/A SPECIFICATIONS

Industrial Power Supplies

60W Constant Current Mode LED Driver. HBG-60 series. File Name:HBG-60-SPEC

DC-DC CONVERTERS 2:1 INPUT RANGE, UP TO 2 WATTS MEDICAL APPLICATIONS MTWA2 SERIES

60W Single Output LED Power Supply. HBG-60 series. File Name:HBG-60-SPEC

AC-DC POWER SUPPLY SINGLE OUTPUT, DESK TOP, 130 WATTS MEDICAL APPLICATIONS MUIG130 SERIES

Note1: tested at nominal Vin, full load and at +25 C ambient. Package (3) CTRL Logic (2)

Output Current Input Current Reflected Ripple. VDC VDC ma ma(typ.) ma(typ.) ma(typ.) VDC μf %

DPX30-xxSxx DC-DC Converter Module 9.5 ~ 18 VDC and 18 ~ 36 VDC and 36~ 75 VDC input; 3.3 to 28 VDC Single Output; 30 Watts Output Power

Load (2) Single or Dual

DPX30-xxDxx DC-DC Converter Module 9.5 ~ 18 VDC and 18 ~ 36 VDC and 36~ 75 VDC input; ±12 to ±15 VDC Dual Output; 30 Watts Output Power

TDK-Lambda ZWS300BAF/A

GB60S 60W Single Output General Purpose Series

DC-DC CONVERTERS 4:1 WIDE INPUT RANGE UP TO 9 WATTS SINGLE AND DUAL OUTPUT, SIP PACKAGE SWB9 SERIES

MPP10-48 S 05 W A - P T Series Name Input Output Output Input Pin Connection Remote On/Off Trim Voltage Quantity Voltage Range Option Options Option

DPX30-xxWSxx DC-DC Converter Module 10 ~ 40VDC, 18 ~ 75VDC input; 3.3 to 28VDC Single Output 30 Watts Output Power

DRB-1 Series Instruction Manual

DH50 SERIES. DATASHEET Rev. A

PRODUCT SPECIFICATION File: EA-520H1U-01 Date: Apr., 7, 2005

DPX15-xxWDxx Dual Output: DC-DC Converter Module 9.5 ~ 36VDC, 18 ~ 75VDC input; ±5 to ±15 VDC Dual Output; 15 Watts Output Power

Features. Unregulated Converters. 2 Watt SIP7 Single and Dual Output RKZE. RKZE- _/_ Protection (4) Isolation Option (3) Single or Dual

SPECIFICATION FOR APPROVAL

DC (on) LED Signal. Multiple output connector for easy wiring

<Designed to meet harmonic current regulations> Board type, ultra-small size, and low cost

(typ.) (Range) Load

C B. Operating up to 5000m altitude 5 year product warranty Models

2W, Low Cost DIP, Dual Output DC/DC Converters

2:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 87% Low Profile, 10.2mm Height Over Current Protection

SPECIFICATION FOR APPROVAL

DPX30-xxWDxx DC-DC Converter Module 10 ~ 40VDC, 18 ~ 75VDC input; ±12 to ±15 VDC Dual Output; 30 Watts Output Power

Sixteenth brick format 4:1 input voltage range 2.25kV basic isolation Remote ON/OFF and trim pins UVLO, OTP, OVP, OCP and SCP Efficiency up to 91%

Output Current Input Current Reflected Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S033

FEATURES. Input Voltage (VDC) 3.3

(typ.) (Range) Input Specifications Parameter Model Min. Typ. Max. Unit 12V Input Models Input Surge Voltage (100ms.

PRODUCT SPECIFICATION File: EA-250U1C-10 Date: May, 25, 2005

PRODUCT SPECIFICATION File: EA-400H2U-02 Date: Feb., 16, 2005

VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S

Output Current Input Current Reflected Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S033

Efficiency (typ.) (Range) Output Voltage Current. Input Current Load VDC VDC ma ma ma(typ.) ma(typ.) ma(typ.

MJWI20 SERIES FEATURES PRODUCT OVERVIEW. DC/DC Converter 20W, Highest Power Density MINMAX MJWI20 Series

PRODUCT SPECIFICATION File: EA- 400ET1-10 Date: Jul., 28, 2006

Output Current Input Current Reflected Ripple. Efficiency (typ.) (Range) VDC VDC ma ma(typ.) ma(typ.) ma(typ.) VDC μf % MTQZ50-72S05

EMERGENCY VEHICLE BATTERY MANAGER PS2024

(typ.) (Range) ±18 330# 89 MPW MPW

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

MD60 Series 60W DINergy Power Supply

Output Voltage Current. Input Current Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma(typ.) μf % 2.

Features. Description. Table of Contents

Notes: Note1: values at nominal input voltage and full load. 8.5VDC 5V 8V. Open, Efficiency vs. Input Voltage. Efficiency [%]

PG02S Series 2W DC/DC CONVERTER, SIP-Package

PRODUCT SPECIFICATION File: EA-600ETF-C10 Date: Mar. 29, 2010

65W. * Fully. and Fixed. *Meet. *Brand

BP- A Series Switch-Mode 3 Stage Battery Charger User s Manual

Note1: Typical values at nominal input voltage and full load. 39VDC. Efficiency vs. Input Voltage. Efficiency [%]

DRL-1 Series Instruction Manual

55185 EMERGENCY PACK FOR LED PANEL TECHNICAL DATA SHEET

4:1 Input Voltage Range 2.25kVDC Isolation UL Certified Efficiency up to 87% Ultraminiature Open Frame SMD No Minimum Load Required

Note1: Typical values at nominal input voltage and full load. 39VDC. Efficiency vs. Input Voltage. Efficiency [%]

2:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 90% Six-Sided Continuous Shield Available as Power Module (RPM30-E)

Lockout Hysteresis Voltage VDC Maximum Input Current Vin=18V, 100% Load A

Features. Regulated Converters. RP20-F 20 Watt 2 x 1 Single & Dual Output. RP20- _F/ Package 4) Control Logic (3) DC/DC Converter

DC/DC Converter URF48_QB-200W(F/H)R3 Series

PDL09-48 S 05 M Series Name Input Output Output Case Voltage Quantity Voltage Option PART NUMBER STRUCTURE

Outdoor 200 W 2 Channel SL-L2701B0N1KR

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

Series AM2D-RZ 2 Watt DC-DC Converter

PDL03-48 S 05 W H Series Name Input Output Output Input Isolation Voltage Quantity Voltage Range Option PART NUMBER STRUCTURE

4:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 88% Six-Sided Continuous Shield Available as Power Module (RPM30-EW)

RWS50B RWS100B RWS150B RWS300B RWS600B

PRODUCTS: POWER SUPPLY

HWS 15A-150A Series. Instruction Manual

Features. Non Isolated Power Module ROF-78E ROF-78E - SMD-R. DC/DC Converter

SH01S/D Series 1W DC/DC CONVERTER, SMD-Package

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

Instruction Manual PFE500F 1000F SERIES. TDK-Lambda PFE500F 1000F Series INSTRUCTION MANUAL

Transcription:

2019-V1.0-0118 Specifications AC-DC Din Rail Mounted Power Supply IS-480 Series, 480W No. 545 Museum Road Yangzhou, Jiangsu China 225009 Tel: 86 (514) 8279 1592 Fax: 86 (514) 8769 3159 2019

AC-DC Din Rail Mountable Power Supply IS-480 SERIES, SINGLE PHASE INPUT Features 3 Year Warranty Universal Input 90~264Vac 100% Full Load Burn-in Test Cooling by Free Air Convection All Round Protections: Short Circuit, Over Voltage, Over Current, Over Temperature LED Indicator for DC Power On LED Indicator for DC Low Applications (All in Pending) Electrical IS 480-24 Output Voltage(VDC) Output Power(W) Series Name Page:1/17

Electrical Part Number Nominal Input Voltage Output Voltage Output Current Ripple (Max.) Efficiency (Typ.) Certificate IS480-24 100-240VAC 24V 20A IS480-48 100-240VAC 48V 10A 1%Vo mvp-p 1%Vo mvp-p 94% CE, FCC, CB, UL, CUL 94% CE, FCC, CB, UL, CUL NOTE: 1. The ripple values are measured at 20MHz of bandwidth by using a 12'' twisted pair-wire terminated with 0.1uF & 47uF parallel capacitor under ambient temperature 25 at rated input voltage and rated load; 2. The efficiency values are measured under ambient temperature 25 at rated input voltage and rated load. Page:2/17

INPUT PARAMETER CONDITIONS MIN TYP MAX UNITS Input voltage 90 264 Vac Input frequency 47 63 Hz Input current Full load, Vin=115Vac Full load, Vin=230Vac 5 2.5 A A Cold start, Vin=115Vac Cold start, Vin=230Vac 40 80 A A Inrush current 1. This product is built in inrush limiting circuit to protect the circuit from surge current damages when the power is turned on. Malfunction can occur by repeating the input voltage on and off rapidly. Therefore, sufficient interval should be given between turning on and off the power; 2. To avoid connecting the switch or fuse to input terminal(outside of the power supply), more consideration should be given when selecting the parts that can endure the inrush current Power factor(pf) Full load, Vin=115Vac Full load, Vin=230Vac 0.99 0.97 Stand-by power consumption Vin=230Vac 5 W Surge voltage L-N 2 KV Page:3/17

OUTPUT PARAMETER CONDITIONS MIN TYP MAX UNITS Output voltage accuracy 2 % IS240-24 IS240-48 22-27 43-52 V V Output voltage adjustment range Output voltage can be adjusted within above range by V-ADJ. variable resistance inside of the power supply. When output voltage exceeds the range, the power supply will be in failure or get into over voltage protection mode. To avoid the case that the output voltage is higher than rated voltage, output current should be used under rated current Minimum load 0 % Line regulation Vin from 100Vac to 240Vac 2 % Load regulation Vout from min. to max. 3 % Turn-on delay time Full load, Vin=115Vac 3600 ms Hold up time Full load, Vin=115Vac 20 ms Page:4/17

Protection Short circuit Hiccuo mode, it will recover automatically after fault condition is removed IS480-24: over voltage protection value 32V IS480-48: over voltage protection value 62V Over voltage (1) When output voltage exceeds above over voltage protection value or reversal voltage occurs, the protection will be started and the output voltage will be cut off in order to protect the power supply; (2) The power supply will recover after the power is turned on again IS480-24: over current protection value 30A IS480-48: over current protection value 15A Over current (1) When output voltage exceeds above over current protection value, the protection will be started and the output voltage will be cut off in order to protect the power supply; (2) The power supply will recover automatically after the fault condition is removed Over temperature protection value: 110±10 Over temperature (1) When the ambient temperature exceeds above over temperature protection value, the protection will be started and go into hiccup mode; (2) The power supply will recover automatically after the fault condition is removed Page:5/17

Environment PARAMETER CONDITIONS MIN TYP MAX UNITS Ambient operating temperature Startup at rated voltage -25 +70 Operating relative humidity Non condensing 20 95 % Storagetemperature Humidity 5 ~ 95% RH -40 +85 MTBF Fullload, 220Vac input, 25 ambient temperature 230 Khrs DC-OK led DC-Low led LED(Green) DC OK LED light will be ON when properly operated LED(Red) DC Low LED light will be ON: (1) when output voltage is below 85%(±2.5%) from the rated output voltage; (2) when get over voltage, over current, over temperature and short circuit fault Colling Free air convection Mounting method Dimension(W x H x D) Weight Packing Vertical 60.0 x 130.0 x 125.0mm (2.36 x 5.12 x 4.92inch) 1000g 11pcs/12.5kg/0.7cuft/carton Carton size 620 x 260 x 175mm(LxWxH) Page:6/17

Safety/EMC Isolation voltage Insulation resistance Safety I/P-O/P:3KVac, I/P-FG: 1.5KVac, O/P-FG: 0.5KVac 100MΩ Max./500VDC Design refer to UL60950-1, EN60950-1 EMC EN 55032:2015+AC:2011 (CISPR 22:2008) ClassA EN 61000-3-2:2014 (IEC 61000-3-2:2014) EN 61000-3-3:2013 (IEC 61000-3-3:2013) EN 55024:2010/A1:2015 (CISPR 24:2010) NOTE: Unless otherwise specified, all the above parameters are measured at ambient temperature of 25 andvin=100vac to 240Vac. Page:7/17

Mechanical 1 125±1.0 60±1.0 7.5 7.5 7.5 DIN Rail (Width: 35mm) 35 47.5 130±1.0 115±0.5 12.3 LABEL PRINTING Output Voltage Adjustment 8 7 79 LED (DC OK) LED (DC LOW) 47.5 NAME PLATE SN code 7.5 7.5 6 8 Max. 110.4 14.7 Unit: mm Tolerance: ±1.0 Page:8/17

Mechanical 1 2 3 4 Marking No. Assignment V-ADJ. DC OK DC LOW 1 2 3 4 DC(+) Output Terminal DC(-) Output Terminal L 5 AC(L) Input Terminal N 6 AC(N) Input Terminal 7 AC Grounding Terminal L N 5 6 7 V-ADJ. / DC Output voltage adjustment trimmer DC OK / DC Output OK indication LED(Green) DC LOW / DC Output Low indication LED(Red) Page:9/17

Electrical Curve Load(%) 100 90 80 70 60 50 40 30 230Vac Input 110Vac Input Load(%) 100 90 80 70 60 50 40 30-10 0 10 20 30 40 50 60 70 90 110 130 150 170 190 210 230 264 Temperature( ) Input voltage(vac) Block Diagram +V L N Line Filter Rectifier Circuit Inrush Current Limit PFC Circuit Switching Device Rectifier Circuit Current Detect +V -V -V FG PWM Control Circuit Error AMP OVP Detect Output Detect DC OK(Green) DC Low(Red) Page:10/17

Package Inner Box L 178 x W 164 x H 67mm Outer Carton L 620 x W 260 x H 185mm SERIES QTY/BOX QTY/CARTON NET WEIGHT GROSS WEIGHT VOLUME IS-480 1 piece 11 boxes 11kg/carton 12.5kg/carton 0.7cuft/carton Page:11/17

Application Note 1. Series Operation LOAD LOAD LOAD L N L N L N L N Series Operation A Series Operation B Note: 1. Series operation can be connected as shown in above; 2. Load current should be less than the current value of the product with the lowest output current specified at the product specification with the power supply at series connection. Page:12/17

Application Note 2. Parallel Operation LOAD LOAD L N L N L N L N Parallel Operation A (Unable to use) Parallel Operation B (Unable to use) LOAD L N L N Parallel Operation C (Backup) Note: 1. Parallel operation should be composed with the same products, while the connection should be as shown as Parallel operation C ; 2. In parallel operation C, current capacity cannot be increased, while it should be used for backup only. Moreover, diode that is to be added during parallel operation should be selected after considering it s voltage drop, output voltage and current capacity. Page:13/17

Application Note 3. Mounting Method (1) How to fix Firstly hang A part on the top of Rail as shown in below, then push the power supply into B direction to fix it. (2) How to remove Remove the power supply to D direction, pulling C part by using tools, such as a screwdriver, to downward direction. Page:14/17

Application Note 3. Mounting Method (3) Mounting Spacing Mounting method should be considered with airflow. Leave enough space between the units when several units are mounted together. Forced air cooling makes protection against heat better. AIR 25mm or more 25mm L N L N AIR 25mm Page:15/17

Application Note 4. Cautions (1) Please confirm if the capacity of the product is suitable for your intended application before putting it in use; (2) Only the rated input voltage specified on the product should be used; (3) Only the wires with rated capacity should be connected to this product, as allowable voltage and current is varied according to each type of wire; (4) Ground terminal of the power supply must be grounded before use to prevent electric shock or electromaganetic interference; (5) Be cautions to keep the product clean as foreign matter near the input & output terminal or inside if the product could cause series damages; (6) If a fuse installed in the product blows off, the product should experience damages not only to the fuse but also to other parts as well. Therefore, the product is to be required for maintenance work from customer service department as well as replacement of the fuse; (7) Due to constant leakage current flows within the product, extra caution should be made if multiple number of products are used connecting to each other as total leakage current c- ould be amounted beyond the capacity; (8) Be sure to avoid any physical contact with the product since some of the parts inside of the product are being functioned at high voltage, which could cause serious electric shock; (9) For the purpose of safety as well as reliability of the product, please avoid using the product at the following sites: - A place near water or fire - A place with high room temperature and poor ventilation - A place with a presence of foreign subject or dust - A place near volatile or flammable compounds - A place with high humidity - A place vulnerable for vibration or shock (10) Do not inspect or repair the product while the power is applied; (11) Unauthorized modification should be avoided in order to prevent series injury or physical loss due to any malfunction; (12) In case of power outage while in operation, be sure to turn off the power supply. Page:16/17

Application Note 5. Warranty (1) Repair service will be provided for free upon any mechanical, technical or functional defects during the guaranteed warranty, however, any defects or malfunction due to international infliction or negligence by customers will be repaired at the customer s expense; (2) Guaranteed warranty of the product runs for 3 years, while appearance and specification of the product is subject for change without any prior notification for the purpose of quality improvement of the product. Page:17/17

Update Record Date Version Updated Content Updated By Approved By 2019/01/18 2019-V1.0-0118 File created