MAX 5e Shielded Modules The shielded MAX module is the cornerstone of our category 5e screened cabling systems. This product not only meets all TIA/EIA component specifications, but also exceeds ISO/IEC 80 nd edition and EN507 nd edition requirements for transfer impedance and shield effectiveness. 6 5 Simple Termination Category 5e shielded MAX modules can be terminated in less than three minutes. For the Telecommunications Room and Work Area Category 5e shielded MAX is designed for use with both TERA -MAX patch panels and 0G MAX faceplates. PREMIUM AND SYSTEM 5E F/UTP Fully Shielded Design optimizes shield effectiveness for protection from EMI Easy Identification Colored icons provided for port identification Rear Shield Protection Robust rear shield protects IDC terminations and maintains shield effectiveness 5 6 Easy Termination Press-fit termination makes installation quick and easy Universal Compatibility Compatible with both T568A/B schemes Integrated Grounding No separate grounding tabs required Quick-Ground Termination No additional steps required for termination. Cable shield is automatically terminated within the outlet without additional steps or tools. MAX 5e SHIELDED MODULES Outlets terminate all shielded and shielded cable constructions AWG (0.6 0.5mm) size conductors. MX5-FS................... Flat category 5e shielded MAX module, T568A/B MX5-S.................... Angled category 5e shielded MAX module, T568A/B MX5-KS................... Keystone category 5e screened MAX module, T568A/B Flat and angled modules include one red and one blue icon. Note: Keystone version is designed for integration with various international mounting products and is not compatible with MAX mounting hardware. Doors available separately. Add B for bulk project pack of 00 modules. Technical Tip! Shielded MAX modules are not side-stackable in standard MAX faceplates. 0G MAX faceplates are recommended. www.siemon.com.
PREMIUM AND SYSTEM 5E F/UTP TERA - MAX PATCH PANELS TM-PNLZ--0.........-port TERA-MAX panel, black, U TM-PNLZ-............-port TERA-MAX panel, metallic, U TM-PNLZA--0........-port Angled TERA-MAX panel, black, U TM-PNLZA-..........-port Angled TERA-MAX panel, metallic, U Panels include designation labels, cable ties and mounting hardware. Note: U =.5mm (.75 in.) SYSTEM 5e SHIELDED HD PATCH PANELS The System 5e shielded HD patch panel provides a high density modular solution for termination of -pair shielded cable. It provides transmission performance that meets category 5e system requirements and is fully compliant with shielding effectiveness as defined by the CENELEC and ISO/IEC standards. HD5-S-................. System 5e shielded -port HD5 panel, T568A/T568B, U HD5-RWM................. Rear cable management bracket for HD5-S- Panels include designation labels, cable ties and mounting hardware. Note: U =.5mm (.75 in.) HD PANEL ACCESSORIES HD5-ICON6................ Adhesive-backed strips in a package of 8 for colorcoding and port designation for -, 8-, or 96-port panels (icons not included) HD5-ICON6-LBL............ 0 sheets of labels for HD5-ICON6 for laser printing (6 labels per sheet)* HD5-LBL-80.............. Adhesive strips for sequentially numbering panel ports through 80 for -, 8-, or 96-port panels HD5-LBL6-............... White removable designation strips in a package of eight for -, 8-, or 96-port panels *Visit our web site or contact our Technical Support Department for labeling software. HD5-ICON6 HD5-LBL-80 HD5-LBL6-. www.siemon.com
BladePatch 5e Shielded Modular Cords Siemon s category 5e BladePatch patch cords offer a unique solution for high-density patching environments. They feature an innovative push-pull boot design to control the latch, enabling easy access and removal of the cord in tight-fitting areas. The BladePatch cords are ideal for patching blade servers, patch panels, or any equipment with high density RJ-5 outlets. Push-Pull Boot Activates Latch Universal Compatibility Fits within any standard RJ-5 outlet. Revolutionary Latch Simply push the boot forward to latch into the outlet and pull back to release. PREMIUM AND SYSTEM 5E F/UTP Revolutionary Design Patented pushpull latch design eliminates need to defeat thumb latch used in standard modular plug designs. Enables easy access and removal in high density patching environments Universal Wiring Compatible with T568A/B wiring schemes Snagless Push-pull design eliminates external thumb latch which can snag and break Low Profile Boot Design Optimizes side-stackability of patch cords and allows use in even the most dense equipment High Density The push-pull design enables easy access and removal via the boot in tight-fitting areas. Ordering Information: Category 5e shielded bladepatch, double-ended modular patch cord with push-pull latching design, color matching cord/boot, T568A/B. BP5S-(XX)M-(XX) Cord Length: 0 = 0.9m ( ft.) 05 =.5m (5 ft.) 07 =.m (7 ft.) 0 =.m (0 ft.) 5 =.6m (5 ft.) 0 = 6.m (0 ft.) Cord Color: 0 = Black 0 = White 0 = Red 0 = Gray 05 = Yellow 06 = Blue 07 = Green Add B for bulk project pack of 00 modular cords. www.siemon.com.
PREMIUM AND SYSTEM 5E F/UTP MC 5e Shielded Modular Cords Siemon s shielded MC 5e modular cords are manufactured using stranded shielded cable that meets all category 5e specifications. Modular plugs have an overall shield and meet TIA-968-A and IEC 6060-7 specifications. T568A/B wired assemblies include colored strain-relief boots and are available in a wide range of lengths. Universal Wiring Compatible with T568A/B wiring schemes Latch Guard Boots feature a latch guard to protect plug from snagging when pulling through pathways or cable managers Ordering Information: MC5S-(XX)M-(XX) Color Options Variety of color options available for circuit identification Superior Quality Quality plug components ensure long term resistance to corrosion from humidity, extreme temperatures, and airborne contaminants Category 5e screened MC, double-ended -pair stranded modular cord, color matching jacket/boot, T568A/B, LSOH Factory-Tested Cords are factory terminated and transmission tested to ensure compliance with applicable standards requirements. Compliance Plug geometry meets TIA-968-A and IEC 6060-7 specifications for modular plugs Exceeds ISO/IEC 80:00 requirements for transfer impedance, coupling attenuation and shield effectiveness Stranded Cable: IEC 656-6:00 Compliant LS0H Cordage: IEC 60-, IEC 6075, and IEC 60 compliant Excellent Bend Relief Boot ensures proper bend relief. Cord Length: 0 = 0.9m ( ft.) 05 =.5m (5 ft.) 07 =.m (7 ft.) 0 =.m (0 ft.) 5 =.6m (5 ft.) 0 = 6.m (0 ft.) Cord Color: 0 = Black 0 = White 0 = Red 0 = Gray 05 = Yellow 06 = Blue 07 = Green Add B to end of part number for bulk project pack of 00 cords. Technical Tip! Factory terminated and tested modular cords are required to achieve consistent category 5e compatibility. Field termination is not recommended and is not compliant with Siemon warranty.. www.siemon.com
System 5e COMPLIANCE ISO/IEC 80:00 (Category 5e) TIA-568-C. (Category 5e) IEC 656-5:00 (Category 5e) UL CMP and CSA FT6 UL CMR and CSA FT CABLE CONSTRUCTION F/UTP 0.5mm (0.0 in.) ( AWG) solid bare copper 7.mm (0.9 in.) max jacket diameter Shield is an aluminum foil enclosing a 0.5mm (0.0 in.) ( AWG) tinned copper drain wire ELECTRICAL SPECIFICATIONS DC Resistance <9.8 Ω/00m DC Resistance Unbalance 5% Mutual Capacitance Capacitance Unbalance 5.6 nf/00m <0 pf/00m Characteristic Impedance -00 MHz: 00 ± 5% (ohms) 00-60 MHz: 00 ± 0% 60-50 MHz: 00 ± % NVP CMP 70% CMR 68% TCL 0-0 log(f) db Delay Skew 0ns F/UTP -Pair Cable (US) 9A5P-E-(XX)-RA.......... Plenum (CMP, CSA FT6) 05m (000 ft.), Reel 9A5R-E-(XX)-RA......... Riser (CMR, CSA FT) 05m (000 ft.), Reel Use (XX) to specify jacket color: 0 = white, 0 = gray, 05 = yellow, 06 = blue PHYSICAL PROPERTIES CMP CMR Pulling Tension (max) 0N (5 lbf) 0N (5 lbf) Bend Radius (min) 5mm (.0 in.) 5mm (.0 in.) Installation Temperature 0 to 60 C (+ to 0 F) 0 to 60 C (+ to 0 F) Storage Temperature -0 to 60 C (- to 0 F) -0 to 60 C (- to 0 F) Operating Temperature -0 to 60 C (- to 0 F) -0 to 60 C (- to 0 F) PREMIUM AND SYSTEM 5E F/UTP TRANSMISSION PERFORMANCE GUARANTEED WORST CASE SIEMON TYPICAL Frequency Insertion Loss NEXT PS NEXT ACR PSACR ACR-F PS ACR-F Return Loss Propagation (MHz) (db) (db) (db) (db) (db) (db) (db) (db) Delay (ns).0.. 65. 68. 6. 66. 6. 66. 60. 6. 6.8 67.8 60.8 65.8 0.0 0.0 570 550.0.. 59. 56. 5. 57. 5. 55. 9. 5. 5.8 55.7 8.8 5.7.0. 55 5 0.0 6.5 6.5 5. 50. 7. 5..8 6.9 0.8.9.8 7.8 0.8 5.8 5.0 5.5 55 55 6.0 8. 8. 50. 7.. 8. 9.0. 6.0 0. 9.7.7 6.7.7 5.0 5.5 5 5 0.0 9. 9. 8.8 5.8.8 6.8 6.5 9.6.5 7.6 7.8.7.8 9.7 5.0 5.5 5 5.5.7.5 5.9.9 9.9.9.. 8...9 7.9 0.9 5.9.6. 50 50 6.5 7.0 6.. 8. 5. 9...9 8..9 7.9.8.9 9.8.5.7 59 59 00.0.0.0 8. 5.. 6.. 7. 0. 5..8.8 0.8 5.8 0..5 58 58 60.0* 8.6 6.8 5.. 9...7 8. 0.7 6. 9.7.7 6.7.7 8.7 0. 57 57 00.0*. 0..8 0.8 7.8.8 -.6.6 -.6.6 7.8.7.8 9.7 8.0 9.8 56 57 50.0* 6.9.0. 9. 6. 0. -7.5 -.6-0.5 -.6 5.8 9.8.8 7.8 7. 9. 56 56 00.0*.0 7.. 8. 5. 9. -.8-6. -5.8-8.. 8.. 6. 6.8 8.8 56 56 50.0*.9 0.7 0. 7.. 8. -7.7-0.5-0.7 -.5.9 6.9 9.9.9 6. 8. 56 56 *Values above industry requirements are for information only. All performance based on 00 meters (8 ft.). www.siemon.com.5
PREMIUM AND SYSTEM 5E F/UTP Premium 5e F/UTP -Pair Cable (International) COMPLIANCE ISO/IEC 80:00 (Category 5e) TIA-568-C (Category 5e) IEC 656-5:00 (Category 5e) UL CM UL CMR and CSA FT LS0H: IEC 60-, IEC 6075 and IEC 60 CABLE CONSTRUCTION F/UTP 0.5mm (0.0 in.) ( AWG) solid bare copper 7.mm (0.9 in.) max jacket diameter Shield is an aluminum foil tape enclosing a 0.5mm (0.0 in.) ( AWG) tinned copper drain wire ELECTRICAL SPECIFICATIONS DC Resistance <9.8 Ω/00m DC Resistance Unbalance 5% Mutual Capacitance Capacitance Unbalance 5.6 nf/00m <0 pf/00m Characteristic Impedance -00 MHz: 00 ± 5% (ohms) 00-50 MHz: 00 ± % NVP 69% TCL Delay Skew 0-0 log(f) db 0ns 9A5M-E................. PVC (CM, IEC 60-),Gray Jacket, 05m (000 ft.) Reel-in-Box 9A5R-E................. PVC (CMR, CSA FT, Riser),Blue Jacket, 05m (000 ft.) Reel-in-Box 9A5L-E................. LS0H (IEC 60-), Violet Jacket, 05m (000 ft.), Reel-in-Box PHYSICAL PROPERTIES LS0H CM/CMR Pulling Tension (max) 0N (5 lbf) 0N (5 lbf) Bend Radius (min) 0mm (. in.) 0mm (. in.) Installation Temperature 0 to 60 C (+ to 0 F) 0 to 60 C (+ to 0 F) Storage Temperature -0 to 75 C (- to 67 F) -0 to 75 C (- to 67 F) Operating Temperature -0 to 60 C (- to 0 F) -0 to 60 C (- to 0 F) TRANSMISSION PERFORMANCE TIA & ISO/IEC SIEMON TYPICAL Frequency Insertion Loss NEXT PS NEXT ACR PSACR ACR-F PS ACR-F Return Loss Propagation (MHz) (db) (db) (db) (db) (db) (db) (db) (db) Delay (ns).0..9 65. 79. 6. 7. 6. 77. 60. 70. 6.8 8.8 60.8 78.8 0.0 7.0 570 55.0..7 56. 70. 5. 6. 5. 66.6 9. 59.6 5.8 7.8 8.8 66.8.0.0 55 57 0.0 6.5 5.8 50. 6. 7. 57..8 58.5 0.8 5.5.8 6.8 0.8 58.8 5.0.0 55 50 6.0 8. 7. 7. 6.. 5. 9.0 5.8 6.0 6.8 9.7 60.7 6.7 5.7 5.0.0 5 58 0.0 9. 8. 5.8 59.8.8 5.8 6.5 5.5.5.5 7.8 58.8.8 5.8 5.0.0 5 57.5.7 0.5.9 56.9 9.9 9.9. 6. 8. 9..9 5.9 0.9 8.9.6 0.0 50 55 6.5 7.0 5.0 8. 5. 5. 5.. 7. 8. 0. 7.9 8.9.9.9.5 0.0 59 5 00.0.0 9. 5. 9.... 0.0 0..0.8.8 0.8 8.8 0. 0.0 58 5 60.0* 8.6 5.. 6. 9. 9..7. 0.7. 9.7 0.7 6.7.7 8.7 8.0 57 5 00.0*. 8. 0.8.8 7.8 7.8 -.6 6.7 -.6 9.7 7.8 8.8.8.8 8.0 7.0 56 5 50.0* 6.9. 9.. 6. 6. -7.5.9-0.5.9 5.8 6.8.8 0.8 7. 6.0 56 5 00.0*.0.5 8.. 5. 5. -.8 7.6-5.8 0.6. 5.. 9. 6.8 5.0 56 5 50.0*.9 9. 7.... -7.7.7-0.7-5..9.9 9.9 7.9 6..0 56 5 *Values above industry requirements are for information only All performance based on 00 meters (8 ft.)..6 www.siemon.com