DC9~ typ max 40max 80max. 71 typ max. 120max 120max. 120max. 120max. 60max. 48max. 20max

Similar documents
Basic Characteristics Data

Dual output. Fig. 2.1 Current foldback characteristics

Basic Characteristics Data

Basic Characteristics Data

Basic Characteristics Data

Basic Characteristics Data

Basic Characteristics Data

Basic Characteristics Data

Basic Characteristics Data

Basic Characteristics Data

Basic Characteristics Data

Basic Characteristics Data

Basic Characteristics Data

Basic Characteristics Data

Basic Characteristics Data

Basic Characteristics Data

1. DBS series. Applications Manual

Basic Characteristics Data

Basic Characteristics Data

Basic Characteristics Data

1 Terminal Block A-22

Basic Characteristics Data

Basic Characteristics Data

Applications Manual. Table of contents. 1. DBS series. 2. CBS series. 3. CDS series. 4. Application Circuits. 6. DPA and DPF series. 7.

MODEL LEP100F-24 LEP100F-36 LEP100F-48 DC OUTPUT +24V 4.2(Peak 7)A +36V 2.8(Peak 4.7)A +48V 2.1(Peak 3.5)A

(DC/DC) SERIES to 96.5% (typical) Product Lineup. Ordering Information. Features. General Description. Super high efficiency

<Designed to meet harmonic current regulations> Board type, ultra-small size, and low cost

PS6R 480W Switching Power Supply

Basic Characteristics Data

LS200 Series Instruction Manual

MODEL MMC8A-1 MMC8A-2 MMC8A-3 V1 +5V 1.2A +5V 1.1A +5V 1.2A DC OUTPUT V2 +12V 0.1A +15V 0.1A +12V 0.1A V3-12V 0.1A -15V 0.1A -5V 0.

Power Supplies. PS6R Series Switching Power Supplies. Expandable and space-saving switching power supplies. High efficiency reduces operation costs.

CCG Series Instruction Manual

TDK-Lambda ZWS240BP/A SPECIFICATIONS

Table 2 Models BST12M-0.7S03PDM BST12M-0.7S06PDM BST12M-0.7S10PDM Conditions Input voltage range

Ultra small size adjustable output type high voltage power supply 2W to 2.6W high voltage DC-DC converter 0V-470V 1000V 1500V 2000V MHV Series

CN100A110 SERIES Instruction Manual

Basic Characteristics Data

DC/DC converter SINGLE OUTPUT

Output Current Input Current Over Load VDC VDC ma ma(typ.) ma(typ.) VDC μf %

LANC245.1W12. DC/DC Converter VDC Input 5.1 VDC Output at 2.4A. Features:

Model Number Output Voltage Output Amps Input Range Max. Iin FL Efficiency Max Output Power

POWERBOX Industrial Line PMF20W Series 20W 4:1 Single Output DC/DC Converter Manual. DC/DC Converter Features. Introduction

CN-A110 SERIES Instruction Manual

C B. Operating up to 5000m altitude 5 year product warranty Models

Small Type High-Speed Response POL DC-DC Converter BSV-nano Series

Applications Manual of DPG serises

ZWD100PAF Series Instruction Manual

ZWD225PAF Series Instruction Manual

Power Modules (Power Supplies with Ultra-low Standby Power Consumption) DC V

DRB-1 Series Instruction Manual

MPM0527SJ Datasheet. Power Modules (Power Supplies with Ultra-low Standby Power Consumption) TAMURA CORPORATION Rev.

Output Current Input Current Reflected Ripple. VDC VDC ma ma(typ.) ma(typ.) ma(typ.) VDC μf %

PAF SERIES. Features. Model naming method PAF 500 F / Conformity to RoHS Directive. Applications. Product Line up. DC/DC Module 400W-700W PAF

Technical Information Solid State Relays. Glossary. Solid State Relays

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

Output Current Input Current Reflected Ripple. Efficiency (typ.) (Range) VDC VDC ma ma(typ.) ma(typ.) ma(typ.) VDC μf % MTQZ50-72S05

Efficiency (typ.) (Range) Output Voltage Current. Input Current Load VDC VDC ma ma ma(typ.) ma(typ.) ma(typ.

Switching Power Supply

Features. Description. Table of Contents

TDK-Lambda ZWS300BAF/A

PAF F280 SERIES Instruction Manual

BPM2417SJ Datasheet. Power Modules (Power Supplies with Ultra-low Standby Power Consumption) TAMURA CORPORATION Rev.

DC/DC Converter URF48_QB-75W(F/H)R3 Series

Output Voltage Current. Input Current Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma(typ.) μf % 2.

DC-DC CONVERTERS 2:1 INPUT RANGE, UP TO 2 WATTS MEDICAL APPLICATIONS MTWA2 SERIES

Instruction Manual PFE500F 1000F SERIES. TDK-Lambda PFE500F 1000F Series INSTRUCTION MANUAL

Five Improvements by Power Supply Modules. Switching power supply and power modules. External Dimensions / Pin assignment, SPM Series

DC/DC Converter URF48_QB-200W(F/H)R3 Series

(typ.) (Range) ±18 330# 89 MPW MPW

SL Series Application Notes. SL Series - Application Notes. General Application Notes. Wire Gage & Distance to Load

Output Current Input Current Reflected Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S033

PFE1000FA Series. Instruction Manual

TL RELAYS. TYPICAL APPLICATIONS Head lamp, Fog lamp, Fan motor, etc. ORDERING INFORMATION TYPES. High Load Relay for Smart Junction Box ACTL.

DPX30-xxSxx DC-DC Converter Module 9.5 ~ 18 VDC and 18 ~ 36 VDC and 36~ 75 VDC input; 3.3 to 28 VDC Single Output; 30 Watts Output Power

EPM1510SJ Datasheet. Power Modules (Power Supplies with Ultra-low Standby Power Consumption) TAMURA CORPORATION Rev.

DPX30-xxDxx DC-DC Converter Module 9.5 ~ 18 VDC and 18 ~ 36 VDC and 36~ 75 VDC input; ±12 to ±15 VDC Dual Output; 30 Watts Output Power

MODEL TUNS50F05 TUNS50F12 TUNS50F24 VOLTAGE[V]

DRL-1 Series Instruction Manual

PFE700SA Series Instruction Manual

Sorensen XG 1700 Series 1700 W A Watt, 1U Programmable DC Power Supplies V. Key Features. Key Modes

DPX30-xxWSxx DC-DC Converter Module 10 ~ 40VDC, 18 ~ 75VDC input; 3.3 to 28VDC Single Output 30 Watts Output Power

Output Current Input Current Reflected Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S033

PAF500F24 SERIES Instruction Manual

ZWS-BP Series. Instruction Manual. TDK-Lambda. ZWS-BP Series. Instruction Manual A C

MJWI20 SERIES FEATURES PRODUCT OVERVIEW. DC/DC Converter 20W, Highest Power Density MINMAX MJWI20 Series

Efficiency Model dependant 86 ~ 88% Isolation. Isolation Cap. Switching Freq. Safety. Case Material Base Material Potting.

VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S

Maximum input voltage 420V or less Including peak value

ECP180 Series. Low 1 Profile. High Power Density. 2.0 by 4.0 Footprint. 120W Convection-cooled Rating. 180W Force Cooled Rating

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

(typ.) (Range) Input Specifications Parameter Model Min. Typ. Max. Unit 12V Input Models Input Surge Voltage (100ms.

RP Instruction Manual

FLAT/VERTICAL TYPE HIGH POWER BIFURCATED CONTACT

TRC ELECTRONICS, INC DC/DC Converter SIP Package 6W MEAN WELL SPBW06 & DPBW06 Series

PG02S Series 2W DC/DC CONVERTER, SIP-Package

Ordering Information. Switching Power Supply S82F. Industrial-Grade Power Supply for General or Peak Load Applications SWITCHING POWER SUPPLIES

D R C- 4 0 s e r i e s

Application Note TES 1 Series

DPX30-xxWDxx DC-DC Converter Module 10 ~ 40VDC, 18 ~ 75VDC input; ±12 to ±15 VDC Dual Output; 30 Watts Output Power

Transcription:

ZU SERIES DC/DC CONVERTER ZUS1R R Thin profile Isolated between input-output Built-in overcurrent protection circuit UL recognized, TÜV approved, CSA certified Five-year warranty ORDERING INFORMATION ZUS1R120 Output voltage Input voltage Output wattage Single output Series name SPECIFICATIONS INPUT OUTPUT PROTECTION CIRCUIT MODEL ZUS1R00 ZUS1R012 ZUS1R01 ZUS1R120 ZUS1R1212 ZUS1R121 ZUS1R240 ZUS1R2412 ZUS1R241 ZUS1R480 ZUS1R4812 ZUS1R481 VOLTAGE [V] DC4.~9 DC9~18 DC18~36 DC 36~72 CURRENT [A] 1 0.441 typ 0.49 typ 0.441 typ 0.176 typ 0.183 typ 0.176 typ 0.088 typ 0.092 typ 0.088 typ 0.043 typ 0.04 typ 0.043 typ EFFICIENCY VOLTAGE CURRENT LINE REGULATION LOAD REGULATION RIPPLE 3 [%] 1 [V] [A] [mv] [mv] [mvp-p] 68 typ 0.30 20max 40max 80max 68 typ 12 0.13 48max max 68 typ 1 0.10 60max 71 typ 0.30 20max 40max 80max 71 typ 12 0.13 48max max 71 typ 1 0.10 60max 71 typ 0.30 20max 40max 80max 71 typ 12 0.13 48max max 71 typ 1 0.10 60max 73 typ 0.30 20max 40max 80max 73 typ 12 0.13 48max max 73 typ 1 0.10 60max RIPPLE [mvp-p] NOISE 3 10max 10max 10max 10max 10max 10max 10max 10max TEMPERATURE [mv] REGULATION -20 C ~+ C 0max 10max 180max 0max 10max 180max 0max 10max 180max 0max 10max 180max DRIFT [mv] 2 20max 48max 60max 20max 48max 60max 20max 48max 60max 20max 48max 60max START-UP TIME [ms] 20max (Minimum input, lo=%) 0UTPUT VOLTAGE ADJUSTMENT RANGE [V] FIXED 0UTPUT VOLTAGE SETTING [V] 4.8~.2 11.40~12.60 14.2~1.7 4.8~.2 11.40~12.60 14.2~1.7 4.8~.2 11.40~12.60 14.2~1.7 4.8~.2 11.40~12.60 14.2~1.7 OVERCURRENT PROTECTION Works over 10% of rating and recovers automatically INPUT-OUTPUT AC00V, 1 minute. Cutoff current=10ma, DC00V, 0MΩ min(at Room Temperature) ISOLATION INPUT-CASE AC00V, 1 minute. Cutoff current=10ma, DC00V, 0MΩ min(at Room Temperature) OUTPUT-CASE AC00V, 1 minute. Cutoff current=10ma, DC00V, 0MΩ min(at Room Temperature) OPERATING TEMP., HUMID. AND ALTITUDE -20~+71ª, 20~9%RH(Non condensing)(refer to DERATING CURVE), 3,000m(10,000feet)max STORAGE TEMP., ENVIRONMENT HUMID. AND ALTITUDE -40~+8ª, 20~9%RH(Non condensing), 9,000m(30,000feet)max VIBRATION 10~Hz, 98.0m/s 2 (10G), 3 minutes period, 60 minutes along X, Y and Z axis IMPACT 490.3m/s 2 (0G), 11ms, once each X, Y and Z axis SAFETY AGENCY APPROVALS UL190, EN6090, CSA C22.2 No.90 Complies with IEC6090 1 Rated input V, 12V, 24V or 48V DC Io=%. 2 The drift is a change at 2ª of ambient temperature and 30 minutes~8 hours after the input voltage applied at rated input/output. 3 Measured by 20MHz oscilloscope. Series/Parallel operation with other model is not possible. 388

EXTERNAL VIEW MODEL MAX OUTPUT WATTAGE DC OUTPUT VOLTAGE DC OUTPUT CURRENT ZUS1R ZUS1R ZUS1R 00 120 240 480 012 1212 2412 4812 01 121 241 481 1.0W V 0.30A 1.6W 12V 0.13A DC/DC CONVERTER (SINGLE OUTPUT) 1.0W 1V 0.10A Outline (1.2) Recomended size for processing PCB (TOP VIEW) (19.46) (1.2) 2-º1.6 6.3 12.7 17.78 6.3 8.89 (1.2) 21.9 (8.03) (1.2) 4-º1. The converter is in contact with the slanted area of the P.C.B. To keep isolation, adequate wiring on the Dimensions in mm mounted side is required. Div.: 0.1inch STATIC CHARACTERISTICS (ZUS1R240) RISE TIME & FALL TIME (ZUS1R240) OVERCURRENT CHARACTERISTICS (ZUS1R240) DERATING CURVE 389

Basic characteristics data Model Circuit method Switching frequency [khz] Input current [A] Rated input fuse Inrush current protection Material PCB/Pattern Single sided Double sided Series/Parallel operation availability Series operation Parallel operation ZUS1R ZUW1R ZTS1R ZTW1R Flyback converter 310~1600 - glass fabric base, epoxy resin Yes *2 *2 ZUS3 ZUW3 ZTS3 ZTW3 ZUS6 ZUW6 ZUS10 ZUW10 ZUS1 ZUW1 ZUS2 ZUW2 Flyback converter Flyback converter Flyback converter Single ended forward converter Single ended forward converter 200~1600 10~1600 ~ 200 330~ 400 330~ 400 *1 Refer to table No.1 - - - - - glass fabric base, epoxy resin glass fabric base, epoxy resin glass fabric base, epoxy resin glass fabric base, epoxy resin glass fabric base, epoxy resin Yes Yes Yes Yes Yes *2 *2 Yes Yes Yes *2 *2 *2 *2 *2 *1 Refer to Specification. *2 Refer to Instruction Manual. Output Power 1.W 3 W 6 W 10 W 1 W 2 W 12V 12V 12V Table 1. Rated Input Fuse Input Voltage V 12V 24V 1.2A 2.0A 4.0A 6.3A 8.0A 10.0A 12V 12V 12V 0.8A 1.2A 2.0A 3.A.0A 6.3A 12V 12V 0.8A 0.8A 1.2A 2.0A 2.0A 3.1A 12V 12V 48V 0.8A 0.8A 0.8A 1.0A 2.0A 2.0A 420

Instruction Manual ZU1R ZU3 ZU6 ZU10 1 Pin Connection............ 422 Function.................... 422 2 2.1 Input voltage........................ 422 2.2 Overcurrent protection............... 422 2.3 Isolation............................ 422 3 Wiring to Input/Output Pin.. 423 Series Operation and Parallel Operation.. 423 4 4.1 Series operation..................... 423 4.2 Parallel redundancy operation......... 424 Assembling and Installation Method.. 424.1 Installation method.................. 424.2 Derating........................... 42 6 7 8 9 10 Input Voltage/Current Range.. 42 Cleaning.....................42 Soldering....................42 Input/Output Pin........... 426 Peak Current (Pulse Load).. 426 ZU1 ZU2 1 Pin Connection............ 427 Function.................... 427 2 2.1 Input voltage........................ 427 2.2 Overcurrent protection............... 427 2.3 Overvoltage protection............... 427 2.4 Adjustable voltage range............. 428 2. Remote ON/OFF....................428 2.6 Isolation............................ 428 3 Wiring to Input/Output Pin.. 429 Series Operation and Parallel Operation.. 429 4 4.1 Series operation..................... 429 4.2 Parallel redundancy operation......... 430 Assembling and Installation Method.. 430.1 Installation method...................430.2 Derating............................430 6 7 8 9 10 Input Voltage/Current Range.. 431 Cleaning.....................431 Soldering....................431 Input/Output Pin........... 432 Peak Current (Pulse Load).. 432 ZT1R ZT3 1 Pin Connection........... 433 Function.................... 433 2 2.1 Input voltage........................ 433 2.2 Overcurrent protection................433 2.3 Isolation............................ 433 3 Wiring to Input/Output Pin.. 434 Series Operation and Parallel Operation.. 434 4 4.1 Series operation..................... 434 4.2 Parallel redundancy operation......... 43 Assembling and Installation Method.. 43.1 Installation method.................. 43.2 Derating............................43 6 7 8 9 10 Input Voltage/Current Range.. 43 Cleaning.....................436 Soldering....................436 Input/Output Pin........... 436 Peak Current (Pulse Load).. 437 421

ZU1R ZU3 ZU6 ZU10 1. Pin Connection No. q w e r t y Pin connection +DC INPUT -DC INPUT +DC OUTPUT COMMON -DC OUTPUT Case connecting pin Function +Side of input voltage -Side of input voltage +Side of output voltage GND of output voltage(only applicable for Dual output) -Side of output voltage If connected to -side of input, the case potential can be fixed and the value of radiation noise can be reduced. Single Output Dual(±)Output connecting pin Case connecting pin is available. By connecting this pin to -side of input, the radiation noise from main body can be reduced. 2. Function 2.1 Input voltage If the wrong input is applied, the unit will not operate properly and/or may be damaged. 2.2 Overcurrent protection Overcurrent protection circuit is built-in and comes into effect at over 10% of the rated current. Overcurrent protection prevents the unit from short circuit and over current condition of less than 20 sec. The unit automatically recovers when the fault condition is cleared. The power supply which has a current foldback characteristics may not start up when connected to nonlinear load such as lamp, motor or constant current load. See the characteristics below. 2.3 Isolation : Load characteristics of power supply : Characteristics of load (lamp, motor, constant current load, etc.) Note: In case of nonlinear load, the output is locked out at A point. Fig. 2.1 Current foldback characteristics For a receiving inspection, such as Hi-Pot test, gradually increase(decrease)the voltage for the start(shut down). Avoid using Hi-Pot tester with the timer because it may generate voltage a few times higher than the applied voltage, at ON/OFF of a timer. 422

ZU1R ZU3 ZU6 ZU10 3. Wiring to Input/Output Pin Input filter is built-in. A capacitor Ci, if installed near the input terminal, will lower the input conducted noise from converter due to the formation of the π type filter. When the distance from the DC line to the unit is greatly extended, it makes the input feedback noise much higher and the input voltage several times higher than the normal level when turned ON. If this happens, the output power also becomes unstable. In order to prevent the unit form failing in this way; please connect Ci to the input terminal. In addition, when the filter with "L" is used, please Ci to the input terminal. Capacity of external capacitor at input terminal: Ci[µF] Model ZUSIR ZUS3 ZUS6 ZUS10 Input voltage(v) ZUWIR ZUW3 ZUW6 ZUW10 220 470 470 12 47 220 220 24 33 47 48 10 22 47 47 Fig. 3.1 Connecting method of capacitor at input terminal To lower the output ripple voltage further, install an external capacitor Co at output terminal as shown below. ZUS ZUW Capacity of external capacitor at output terminal: Co[µF] Model ZUS1R ZUS3 ZUS6 ZUS10 Output voltage(v) ZUW1R ZUW3 ZUW6 ZUW10 3, 220 220 220 12 1 Fig. 3.2 Connecting method of external capacitor at output terminal When the distance between load and DC output is long, please install capacitor at load as shown below. Fig. 3.3 Connection method of capacitor at load 4. Series Operation and Parallel Operation 4.1 Series operation ZUS1R/ZUW1R ZUS3/ZUW3 ZUS6/ZUW6 Series operation is available by connecting the outputs of two or more power supplies, as shown below. Output currents in series connection should be lower than the lowest rated current in each unit. But at series operation with same output voltage, diode is not required to attach even if at (a). When the output voltage is less than V. When the output voltage is more than 12V. Power supply Power supply + - + - D1 D3 D2 D4 Load D1~D4: Please use Schottky Barrier Diode. D1 D2: Please use Schottky Barrier Diode. 423

ZU1R ZU3 ZU6 ZU10 ZUS10/ZUW10 Series operation is available by connecting the outputs of two or more power supplies as shown below. Output currents in series connection should be lower than the lowest rated current in each unit. (c) (d) 4.2 Parallel redundancy operation Parallel redundancy operation is available by connecting the units as shown below. I1, I2 the rated current value. Assembling and Installation Method.1 Installation method The unit can be mounted in any direction. Position them with proper intervals to allow enough air ventilation. Ambient temperature around each power supply should not exceed the temperature range shown in derating curve. Avoid placing the DC input line pattern layout underneath the unit because it will increase the line conducted noise. Make sure to leave an ample distance between the line pattern layout and the unit. Also, avoid placing the DC output line pattern underneath the unit because it may increase the output noise. Lay out the pattern away from the unit. YES NO Fig..1 Pattern wiring 424

ZU1R ZU3 ZU6 ZU10.2 Derating By derating the output current, it is possible to operate the unit from -20ª~+71ª (-20ª~+8ª at forced air cooling). When unit mounted any way other than in drawings below, it is required to consider ventilated environments by forced air cooling or temperature/load derating. For details, please consult our sales or engineering department. 6. Input Voltage/Current Range When a non-regulated source is used as a front end, make sure that the voltage fluctuation together with the ripple voltage will not exceed the input voltage range. Select the converter that is able to handle the start-up current(ip). Fig. 6.1 Input current characteristics 7. Cleaning Cleaning is possible by below listed conditions. No. 1 2 3 4 Classification Water type Solvent type Cleaning method Cleaning agents Cleaning method Liquid Temp. Pine Alpha ST S(ARAKAWA CHEMICAL CO.) Clean Through 70H(KAO Corporation) IPA Asahiklin AK 22AES(ASAHI GLASS CO.) Varnishing or Ultra sonic wave Varnishing,Ultra sonic wave, Vapor Less than 60 C Period Within minutes Within 2 minutes During cleaning to drying (the condition that cleaning liquid is soaked into the ink of name plate), do not touch on the surface of name plate. After cleaning, dry them enough. 8. Soldering Flow soldering : 260ª less than 1 seconds. Soldering iron : 40ª less than seconds. 42

ZU1R ZU3 ZU6 ZU10 9. Input/Output Pin When too much stress is applied on the input/output pins of the unit, the internal connection may be weakened. As below Fig. 9.1, avoid applying stress of more than 19.6N(2kgf) on the pins horizontally and more than 39.2N(4kgf) vertically. The input/output pins are soldered on PCB internally, therefore, do not pull or bend them with abnormal forces. When additional stress is expected to be put on the input/output pins because of vibration or impacts, fix the unit on PCB (using silicone rubber or fixing fittings) to reduce the stress onto the input/output pins. Fig. 9.1 Stress onto the pins 10. Peak Current (Pulse Load) It is possible to supply the pulse current for the pulse load by connecting the capacitor externally at the output side. The average current Iav of output is shown in below formula. Iav = Is + (Iop - Is)t T The required electrolytic capacitor C is found by below formula. C = (Iop - Iav)t Vo 426

ZU1 ZU2 1. Pin Connection No. q w e r t y u Pin connection +DC INPUT -DC INPUT RC +DC OUTPUT COMMON -DC OUTPUT TRM Function +Side of input voltage -Side of input voltage Remote ON/OFF +Side of output voltage GND of output voltage(only applicable for Dual output) -Side of output voltage Adjustment voltage range Single Output Dual (±) Output 2. Function 2.1 Input voltage If the wrong input is applied, the unit will not operate properly and/or may be damaged. 2.2 Overcurrent protection Overcurrent protection circuit is built-in and comes into effect at over 10% of the rated current. Overcurrent protection prevents the unit from short circuit and over current condition of less than 20 sec. The unit automatically recovers when the fault condition is cleared. 2.3 Overvoltage protection Single Output Fig. 2.1 Overcurrent protection characteristics The overvoltage protection circuit is built-in and comes into effect at 11~140% of the rated voltage. The DC input voltage should be shut down if overvoltage protection is in operation. The minimum interval of DC recycling for recovery 2 to 3 minutes(*). * The recovery time depends on input voltage. Multiple Output By detecting overvoltage condition between +V and -V, overvoltage protection circuit comes into effect at 11~140% of the rated voltage.the DC input voltage should be shut down if overvoltage protection is in operation. The minimum interval of DC recycling for recovery 2 to 3 minutes(*). * The recovery time depends on input voltage. Remarks: Please note that unit's internal components may be damaged if excessive voltage(over rated voltage)is applied to output terminal of power supply. This could happen when the customer tests the overvoltage performance of the unit. 427

ZU1 ZU2 2.4 Adjustable voltage range The output voltage is adjustable by external potentiometer. When the output voltage adjustment is not used, open the TRM pin. The over voltage protection circuit comes into effect when the output voltage is set too high. Output voltage is increased by turning potentiometer clockwise and is decreased by turning potentiometer counterclockwise. The wiring to the potentiometer should be as short as possible and connected to the remote sensing pins (+S and -S). The temperature coefficient varies depending on the type of resistor and potentiometer. It is recommended that the following types be used. Resistor... Metal film type. coefficient of less than ±300ppm/ª Potentiometer... Cermet type, coefficient of less than ±ppm/ª Fig. 2.2 Connection devices outside the power supply Table 2.1 Devices outside the power supply (Adjustable ±%) No. 1 2 3 4 Output voltage 3.3V V 12V ±12V ±1V The constant value of devices outside the power supply(unit: Ω) VR 1K 1K K K K R1 470 270 10K 10K R2 10 270 2.7K 3.9K 2.7K 2. Remote ON/OFF The ground terminal of remote ON/OFF circuit is connected with -V input terminal. Between RC and -V input: Output voltage is ON at Low level or short circuit(0~1.2v) Between RC and -V input: Output voltage is OFF at High level or open circuit(2.4~.v) (Connection example) or or Transistor IC Relay When RC terminal is Low level, fan out current is 1mA typ. When Vcc is applied, use V Vcc 24V. When remote ON/OFF function is not used, please short between RC and -V input. 2.6 Isolation For a receiving inspection, such as Hi-Pot test, gradually increase(decrease)the voltage for the start(shut down). Avoid using Hi-Pot tester with the timer because it may generate voltage a few times higher than the applied voltage, at ON/OFF of a timer. 428

ZU1 ZU2 3. Wiring to Input/Output Pin The input filter is built-in. A capacitor(ci),if installed near the input terminal, will lower the input conducted noise from converter due to the formation of the π type filter. When the distance from the DC line to the unit is greatly extended, it makes the input feedback noise much higher and the input voltage several times higher than the normal level when turned ON. If this happens, the output power also becomes unstable. In order to prevent the unit form failing in this way; please connect Ci to the input terminal. In addition, when the filter with "L" is used, please connect Ci to the input terminal. Fig. 3.1 Connection method of capacitor at input terminal Capacity of external capacitor at input terminal: Ci[µF] Model ZUS1 ZUS2 Input voltage(v) ZUW1 ZUW2 330 470 12 10 220 24 68 48 33 47 To decrease the ripple voltage further, install an external capacitor Co at output terminal as shown below. Capacity of external capacitor at output terminal: Co[µF] ZUS ZUW Model Output voltage(v) 3, 12 1 ZUS1 ZUW1 220 ZUS2 ZUW2 220 Fig. 3.2 Connecting method of external capacitor at output terminal When the distance between load and DC output is long, please install capacitor at load as below. Fig. 3.3 Connection method of capacitor at load 4. Series Operation and Parallel Operation 4.1 Series operation Series operation is available by connecting the outputs of two or more power supplies, as shown below. Output currents in series connection should be lower than the lowest rated current in each unit. (a) (b) 429

ZU1 ZU2 4.2 Parallel redundancy operation Parallel redundancy operation is available by connecting the units as shown below. Values of I1 and I2 become unbalanced by a slight different of the output voltage. Make sure that the output voltage of units is of equal value and the output current from each power supply does not exceed the rated current. I1, I2 the rated current value Use external potentiometer is recommended which can adjust the output voltage.. Assembling and Installation Method.1 Installation method The unit can be mounted in any direction. Position them with proper intervals to allow enough air ventilation. Ambient temperature around each power supply should not exceed the temperature range shown in derating curve. Avoid placing the DC input line pattern layout underneath the unit because it will increase the line conducted noise. Make sure to leave an ample distance between the line pattern layout and the unit. Also, avoid placing the DC output line pattern underneath the unit because it may increase the output noise. Lay out the pattern away from the unit. YES NO Fig..1 Pattern wiring.2 Derating By derating the output current, it is possible to operate the unit from -20ª~+71ª (-20ª~+8ª at forced air cooling). When unit mounted any way other than in drawings below, it is required to consider ventilated environments by forced air cooling or temperature/load derating. For details, please consult our sales or engineering departments. Fig..2 Derating curve 430

ZU1 ZU2 The temperature increase of case surface at full load is shown by below table as referenced data. Temperature increase on surface of case (ZU series) (Unit: deg) Input Voltage V 12V 24V 48V Output Voltage 3V, V 12V ±12V ±1V V 12V ±12V ±1V V 12V ±12V ±1V 3V, V 12V ±12V ±1V 1W 30 36 39 38 28 34 36 3 31 38 34 27 21 23 24 26 2W 38 42 39 40 36 42 43 4 32 38 36 3 28 2 31 31 6. Input Voltage/Current Range When a non-regulated source is used as a front end, make sure that the voltage fluctuation together with the ripple voltage will not exceed the input voltage range. Select the converter that is able to handle the start-up current(ip). Fig. 6.1 Input current characteristics 7. Cleaning Cleaning agents : No. Classification Cleanig agents 1 2 3 4 Pine Alpha ST-S(ARAKAWA CHEMICAL CO.) Water type Clean Through 70H(KAO Corporation) IPA Solvent type Asahiklin AK-22AES(ASAHI GLASS CO.) Cleaning period : The total time of varnishing, ultrasonic wave and vaper should be within 2 minutes. In case of ultrasonic wave cleaning, the ultrasonic should be less than 1kw/m 3. During cleaning to drying (the condition that cleaning liquid is soaked into the ink of name plate), do not touch on the surface of name plate. After cleaning, dry them enough. 8. Soldering Flow soldering : 260ª less than 1 seconds. Soldering iron : 40ª less than seconds. 431

ZU1 ZU2 9. Input/Output Pin When too much stress is applied on the input/output pins of the unit, the internal connection may be weakened. As below Fig. 9.1, avoid applying stress of more than 19.6N(2kgf)on the pins horizontally and more than 39.2N(4kgf)vertically. The input/output pins are soldered on PCB internally, therefore, do not pull or bend them with abnormal forces. When additional stress is expected to be put on the input/output pins because of vibration or impacts, fix the unit on PCB (using silicone rubber or fixing fittings) to reduce the stress onto the input/output pins. Fig. 9.1 Stress onto the pins 10. Peak Current (Pulse Load) It is possible to supply the pulse current for the pulse load by connecting the capacitor externally at the output side. The average current Iav of output is shown in below formula. (Iop - Is)t Iav = Is + T The required electrolytic capacitor C is found by below formula. (Iop - Iav)t C = Vo 432

ZT1R ZT3 1. Pin Connection q w -V +V IN e S Single Output r +V t y NC -V COM OUT No. q w e r t y Pin connection -DC INPUT +DC INPUT Case Connecting Pin +DC OUTPUT Function -Side of input voltage +Side of input voltage If connected to -side of input, the case potential can be fixed and the value of radiation noise can be reduced. +Side of output voltage NC(Single output) No Connection COM(Dual output) GND of output voltage(only applicable for Dual output) -DC OUTPUT -Side of output voltage Dual(±)Output 2. Function Case Connectiong Pin Case connecting pin is available. By connecting the pin to -side of input, the radiation noise from main body can be reduced. 2.1 Input voltage If the wrong input is applied, the unit will not operate properly and/or may be damaged. 2.2 Overcurrent protection Overcurrent protection circuit is built-in and comes into effect at over 10% of the rated current. Overcurrent protection prevents the unit from short circuit and over current condition of less than 20 sec. The unit automatically recovers when the fault condition is cleared. The power supply which has a current foldback characteristics may not start up when connected to nonlinear load such as lamp, motor or constant current load. See the characteristics below. 2.3 Isolation : Load characteristics of power supply : Characteristics of load (lamp, motor, constant current load, etc.) Note: In case of nonlinear load, the output is locked out at A point. Fig. 2.1 Current foldback characteristics For a receiving inspection, such as Hi-Pot test, gradually increase(decrease)the voltage for the start(shut down). Avoid using Hi-Pot tester with the timer because it may generate voltage a few times higher than the applied voltage, at ON/OFF of a timer. 433

ZT1R ZT3 3. Wiring to Input/Output Pin Input filter is built-in. A capacitor Ci, if installed near the input terminal, will lower the input conducted noise from converter due to the formation of the π type filter. When the distance from the DC line to the unit is greatly extended, it makes the input feedback noise much higher and the input voltage several times higher than the normal level when turned ON. If this happens, the output power also becomes unstable. In order to prevent the unit form failing in this way; please connect Ci to the input terminal. In addition, when the filter with "L" is used, please Ci to the input terminal. Capacity of external capacitor at input terminal: Ci[µF] Model Input voltage(v) 12 24 48 ZTSIR ZTWIR 47 33 10 ZTS3 ZTW3 220 47 22 Fig. 3.1 Connecting method of capacitor at input terminal To lower the output ripple voltage further, install an external capacitor Co at output terminal as shown below. ZTS ZTW Capacity of external capacitor at output terminal: Co[µF] Model ZTS1R ZTS3 Output voltage(v) ZTW1R ZTW3 220 12 1 Fig. 3.2 Connecting method of external capacitor at output terminal When the distance between load and DC output is long, please install capacitor at load as shown below. Fig. 3.3 Connection method of capacitor at load 4. Series Operation and Parallel Operation 4.1 Series operation Series operation is available by connecting the outputs of two or more power supplies, as shown below. Output currents in series connection should be lower than the lowest rated current in each unit. But at series operation with same output voltage, diode is not required to attach even if at (a). When the output voltage is less than V. When the output voltage is more than 12V. Power supply Power supply + - + - D1 D3 D2 D4 Load D1~D4: Please use Schottky Barrier Diode. D1, D2: Please use Schottky Barrier Diode. 434

ZT1R ZT3 4.2 Parallel redundancy operation Parallel redundancy operation is available by connecting the units as shown below. I1, I2 the rated current value. Assembling and Installation Method.1 Installation method The unit can be mounted in any direction. Install the device, with proper intervals to allow enough air ventilation..2 Derating Ambient temperature around each power supply should not exceed the temperature range shown in derating curve. Load factor [%] 0 1 Convection[ 1 models] 2 Convection[Other models] 3 Forced air(00r/min)[ 1 models] 4 Forced air(00r/min)[other models] 2 1 3 4 0-20 -10 0 10 20 30 40 0 60 Ambient temperature [ª] (71) (8) 70 80 90 1 ZTS3012, ZTS301 ZTW3012, ZTW301 6. Input Voltage/Current Range When a non-regulated source is used as a front end, make sure that the voltage fluctuation together with the ripple voltage will not exceed the input voltage range. Select the converter that is able to handle the start-up current(ip). Fig. 6.1 Input current characteristics 43

ZT1R ZT3 7. Cleaning Cleaning is possible by below listed conditions. Cleaning method No. 1 2 3 4 Classification Water type Solvent type Cleaning agents Cleaning method Liquid Temp. Pine Alpha ST S(ARAKAWA CHEMICAL CO.) Clean Through 70H(KAO Corporation) IPA Asahiklin AK 22AES(ASAHI GLASS CO.) Varnishing or Ultra sonic wave Varnishing,Ultra sonic wave, Vapor Less than 60 C Period Within minutes Within 2 minutes During cleaning to drying (the condition that cleaning liquid is soaked into the ink of name plate), do not touch on the surface of name plate. After cleaning, dry them enough. 8. Soldering Flow soldering : 260ª less than 1 seconds. Soldering iron : 40ª less than seconds. 9. Input/Output Pin When too much stress is applied on the input/output pins of the unit, the internal connection may be weakened. As below Fig. 9.1, avoid applying stress of more than 9.8N(1kgf) on the pins horizontally and more than 19.6N(2kgf) vertically. When additional stress is expected to be put on the input/output pins because of vibration or impacts, fix the unit on PCB (using silicone rubber or fixing fittings) to reduce the stress onto the input/output pins. A part Less than 9.8N(1kgf) Less than 9.8N(1kgf) Less than 19.6N(2kgf) A Fig. 9.1 Stress onto the pins 436

ZT1R ZT3 10. Peak Current (Pulse Load) It is possible to supply the pulse current for the pulse load by connecting the capacitor externally at the output side. The average current Iav of output is shown in below formula. (Iop - Is)t Iav = Is + T The required electrolytic capacitor C is found by below formula. (Iop - Iav)t C = Vo 437